12-509-049THIRD FLOOR PLAN NEW CONSTRUCTION - FIRE PROTECTION " IIIIIIIII 1111111111 0' 1' 2' IV 8' 12' GENERAL NOTES: 1. CONTRACTOR SHALL PHASE WORK AS DIRECTED BY ARCHITECTURAL DRAWINGS AND OWNER. 2. CONTRACTOR SHALL PATCH WALLS. FLOORS. AND CEILINGS Tp - MATC4... ^ ..... r "" EXISTING FINISHES FOR DEMOLITION AND INSTALLATION OF-FIRE- PROTECTION SYSTEMS. COORDINATE WITH ARCHITECTURAL t AWINGS. ^ 3. THE HOSPITAL IS OPEN 24 HOURS A DAY.7 DAYS A WEEK. THE ^~^ CONTRACTOR SHALL HAVE TO PERFORM WORK WITHIN ACTIVE PATIENT CARE AREAS. CONTRACTOR SHALL: A. COORDINATE SHUTDOWN OF EXISTING SYSTEMS WELL IN ADVANCE WITH OWNER. B. PERFORM WORK AT SUCH TIMES AND UNDER SUCH CONDITIONS AS PRESCRIBED BY OWNER. C. PERFORM WORK WITHIN THE GUIDELINES OF THE ICRA REPORT PREPARED FOR THIS PROJECT BY THE OWNER. D. SEQUENCE DEMOLITION AND NEW CONSTRUCTION TO MINIMIZE NUMBER & DURATION OF SHUTDOWNS REOUIRED. WHERE FEASIBLE INSTALL NEW MAINS PRIOR TO DEMOLITION OF EXISTING. 4. CONTRACTOR SHALL COORDINATE WORK WITH EXISTING CONDITIONS (STRUCTURE. DUCTWORK. PIPING, CONDUIT, ETC.). PROVIDE OFFSETS AS REQUIRED TO INSTALL NEW WORK. 5. PIPING SHOWN TO BE REMOVED IS NOT TO BE CAPPED AND ABANDONED. 6. CONTRACTOR SHALL COORDINATE TIMING, DURATION AND AREAS AFFECTED BY SHUTDOWNS WITH HOSPITAL IN ORDER TO FACILITATE REOUIRED FIRE WATCH. T. CONTRACTOR SHALL COORDINATE NEW SPRINKLER HEAD LOCATIONS WITH CEILING GRID, CEILING MOUNTED DEVICES (LIGHTS. DIFFUSERS. SMOKE DETECTORS. ETC.) AND OBSTRUCTIONS TO SPRINKLER THROW (SOFFITS. PRIVACY CURTAINS. ETC.) PER NFPA 13. 8. CONTRACTOR SHALL LABEL EXISTING PIPING, SHOWN ON THIS DRAWING TO REMAIN, WITHIN PROJECT SCOPE PER SPECIFICATIONS. KEYED NOTES: PROVIDE TEMPORARY SPRINKLER HEAD AND V BRANCH PIPING (SHOWN DASHED) WHERE 0 REQUIRED BY TEMPORARY CONSTRUCTION WALLS PER NFPA (SEE ARCHITECTURAL DRAWINGS). REMOVE SPRINKLER HEAD AND CAP BRANCH PIPING ONCE TEMPORARY WALLS ARE REMOVED. CONSTR UCTION LEGEND ff DESCRIPTION EXISTING TO REMAIN O NEW CONSTRUCTION �--� CONNECT TO EXIST. AT THIS POINT SPRINKLER SCHEDULE 32 SPRINKLER HEADS REMOVED. 37 SPRINKLERS HEADS ADDED. 5 SPRINKLER HEADS ADDED 211 A/S CONTROL VALVE WITH F.S. AND T.S. LOCATED AT STAIR #2- KEYPLAN N �3rd Floor Level >1101111 W ==J O U' i p W' I i.T�./ F- act — I _ i I U' Q � i f c S .a< i Smith eckman Reid, Inc. 600 West Hillsboro, Suite 300 Deerfield Beach, FL 33441 (954) 421 -1260 FAX: (954) 421-1466 www.ssr- inc.com Firm CediSedion - EB- 0000967 n®s.w.k PE-58M Sah.LM..hhr FE -68fl00 MFLWA St—d PE -65701 999 J0B # 1197099.0 O U Z J Q U H W im CO) I-- `� O r O M = J 0 ,�— LL I— W O —ov =0 W Z J _ u.l 0 W w� = Q ch H H '` C0 _ O C0 V QO °c m C� 0 (NO Comm. No: 11087.00 Date: 01/18/12 Drawn: Revised: %'spr�tri�� D = OF �'�t:lttli' FP2.1