12-509-043PARTIAL FIRST FLOOR PLAN - NEW CONSTRUCTION - MEDICAL GAS " 0' 2' 4' 8' 16' 24' GENERAL NOTES: 1. CONTRACTOR SHALL PATCH WALLS AND CEILINGS TO MATCH EXISTING FINISHES FOR INSTALLATION OF CONDUIT TO ALARM PANELS UNLESS NOTED OTHERWISE ON ARCH. DRAWINGS. 2. THE HOSPITAL IS OPEN 24 HOURS A DAY. 7 DAYS A WEEK. THE CONTRACTOR SHALL HAVE TO PERFORM WORK WITHIN ACTIVE PATIENT CARE AREAS. CONTRACTOR SHALL: A. COORDINATE SHUTDOWN OF EXISTING SYSTEMS WELL IN ADVANCE WITH OWNER. B. PERFORM WORK AT SUCH TIMES AND UNDER SUCH CONDITIONS AS PRESCRIBED BY OWNER. C. PERFORM WORK WITHIN THE GUIDELINES OF THE ICRA REPORT PREPARED FOR THIS PROJECT BY THE OWNER. D. SEOUENCE DEMOLITION AND NEW CONSTRUCTION TO MINIMIZE NUMBER & DURATION OF SHUTDOWNS REOUIRED. 3. CONTRACTOR SHALL COORDINATE WORK WITH EXISTING CONDITIONS (STRUCTURE. DUCTWORK. PIPING. CONDUIT, ETC.). PROVIDE OFFSETS AS REQUIRED TO INSTALL NEW WORK. 4. WORK MAY NOT BE LIMITED TO SCOPE OF WORK OR PHASING AREAS INDICATED. BUT ALSO MAY INCLUDE WORK OUTSIDE OF THE SCOPE OF WORK OR PHASING AREAS AS INDICATED BY CONTRACT DOCUMENTS. PARTIAL SECOND FLOOR PLAN NEW CONSTRUCTION - MEDICAL GAS " 'titlrii- 0' 2' 4' 8' 16' 24' KEYED NOTES: N SEE DETAILS FOR ALARM POINTS REQUIRED FROM NON MEDICAL AIR COMPRESSOR INSTALLED AT THIRD FLOOR MECHANICAL ROOM. CONTRACTOR SHALL COORDINATE INSTALLATION OF CONDUIT AND SIGNAL WIRING WITH OWNER. CONSTR UCTION LEGEND ffNEW r: 3 != PARTIAL FIRST FLOOR PLAN - NEW CONSTRUCTION - MEDICAL GAS " 0' 2' 4' 8' 16' 24' GENERAL NOTES: 1. CONTRACTOR SHALL PATCH WALLS AND CEILINGS TO MATCH EXISTING FINISHES FOR INSTALLATION OF CONDUIT TO ALARM PANELS UNLESS NOTED OTHERWISE ON ARCH. DRAWINGS. 2. THE HOSPITAL IS OPEN 24 HOURS A DAY. 7 DAYS A WEEK. THE CONTRACTOR SHALL HAVE TO PERFORM WORK WITHIN ACTIVE PATIENT CARE AREAS. CONTRACTOR SHALL: A. COORDINATE SHUTDOWN OF EXISTING SYSTEMS WELL IN ADVANCE WITH OWNER. B. PERFORM WORK AT SUCH TIMES AND UNDER SUCH CONDITIONS AS PRESCRIBED BY OWNER. C. PERFORM WORK WITHIN THE GUIDELINES OF THE ICRA REPORT PREPARED FOR THIS PROJECT BY THE OWNER. D. SEOUENCE DEMOLITION AND NEW CONSTRUCTION TO MINIMIZE NUMBER & DURATION OF SHUTDOWNS REOUIRED. 3. CONTRACTOR SHALL COORDINATE WORK WITH EXISTING CONDITIONS (STRUCTURE. DUCTWORK. PIPING. CONDUIT, ETC.). PROVIDE OFFSETS AS REQUIRED TO INSTALL NEW WORK. 4. WORK MAY NOT BE LIMITED TO SCOPE OF WORK OR PHASING AREAS INDICATED. BUT ALSO MAY INCLUDE WORK OUTSIDE OF THE SCOPE OF WORK OR PHASING AREAS AS INDICATED BY CONTRACT DOCUMENTS. PARTIAL SECOND FLOOR PLAN NEW CONSTRUCTION - MEDICAL GAS " 'titlrii- 0' 2' 4' 8' 16' 24' KEYED NOTES: N SEE DETAILS FOR ALARM POINTS REQUIRED FROM NON MEDICAL AIR COMPRESSOR INSTALLED AT THIRD FLOOR MECHANICAL ROOM. CONTRACTOR SHALL COORDINATE INSTALLATION OF CONDUIT AND SIGNAL WIRING WITH OWNER. CONSTR UCTION LEGEND ffNEW DESCRIPTION EXISTING TO REMAIN NEW CONSTRUCTION CONNECT TO EXIST. AT THIS POINT W o aD v rn 1 IL o; 0 U� u- LL WW Q D F— Q' W g M%ii W UN 0 J m Q W Q W S 8 C A f C OJ6 0WI Smith `Seckman �I Reid, Inc. 600 West Hillsboro, Suite 300 Deerfield Beach, FL 33441 (954) 421 -1260 FAX: (954) 421 -1466 www.ssr- inc.com Firm CerFifimthm - E 34KHM 57 D.m.n..t. PE -58M Idm MIL.". PE -88800 lrwhagA9t —rd PE -88701 8911 JOF7 S 11920&9.0 O U Z J a U W V! O r a_ M J 0 F— LL LL F— H -J W co a. O 0 (1) Ito c I- = W Z J 0 WW W Q P � _ Ipc 0 �... co U Q0 0 0 (0 O Comm. No: 110$7,00 Date: 01/18/12 Drawn: Revised: AHCA COMMENTS/ COORDINATION 2/6/12 X111111// A-V i i E OF I