12-509-041THIRD FLOOR PLAN - NEW CONSTRUCTION - PLUMBING N 0' 1' 2' 4' 8' 12' GENERAL NOTES: 1. CONTRACTOR SHALL PATCH WALLS, FLOORS AND CEILINGS TO MATCH EXISTING FINISHES FOR DEMOLITION AND INSTALLATION OF PIPING, FIXTURES. EQUIPMENT, ETC UNLESS NOTED OTHERWISE ON ARCH, DRAWINGS., 2. THE HOSPITAL IS OPEN 24 HOURS A DAY, 7 DAYS A -WEEr. THE CONTRACTOR r SHALL HAVE TO PERFORM WORK WITHIN ACTIVE PATIENT -ARE- - _ AREAS. n CONTRACTOR SHALL: A. COORDINATE SHUTDOWN OF EXISTING SYSTEMS WELL IN ADVANCE WITH OWNER. B. PERFORM WORK AT SUCH TIMES AND UNDER SUCH CONDITIONS AS PRESCRIBED BY OWNER. C. PERFORM WORK WITHIN THE GUIDELINES OF THE ICRA REPORT PREPARED FOR THIS PROJECT BY THE OWNER. D. SEQUENCE DEMOLITION AND NEW CONSTRUCTION TO MINIMIZE NUMBER & DURATION OF SHUTDOWNS REQUIRED. 3. CONTRACTOR SHALL COORDINATE WORK WITH EXISTING CONDITIONS (STRUCTURE. DUCTWORK. PIPING, CONDUIT. ETC.). PROVIDE OFFSETS AS REQUIRED TO INSTALL NEW WORK. 4. CONTRACTOR SHALL LOCATE ALL NEW VALVES AT ACCESSIBLE LOCATIONS. PROVIDE ACCESS PANELS, AS REQUIRED, FOR VALVES LOCATED ABOVE HARD CEILINGS. 5. ALL WASTE. N T&I SLOPED LL WAS ES STORM CONDENSAE PIPNG 21/ & LA LARGER TO BE SLOPED Q /8 /FT. 6. WORK MAY NOT BE LIMITED TO SCOPE OF WORK OR PHASING AREAS INDICATED. BUT ALSO MAY INCLUDE WORK OUTSIDE OF THE SCOPE OF WORK OR PHASING AREAS AS INDICATED BY CONTRACT DOCUMENTS. 7. CONTRACTOR SHALL FIELD VERIFY WITH HOSPITAL LOCATION OF EXISTING SERVICE VALVES FOR SHUTDOWN OF CW AND HW. COORDINATE TIMING, DURATION AND AREA AFFECTED BY SHUTDOWN WITH HOSPITAL. 8. CONTRACTOR SHALL LABEL EXISTING PIPING SHOWN TO REMAIN WITHIN AREA OF WORK PER SPECIFICATIONS. 9. PIPING SHOWN IS ROUTED AT THIRD FLOOR CEILING UNLESS NOTED OTHERWISE. 10. CONTRACTOR SHALL OFFSET NEW WASTE PIPING DROPS AS REQUIRED TO AVOID STRUCTURAL JOISTS. 11. CONTRACTOR TO REMOVE EXISTING STACKS AND RISERS LOCATED IN EXISTING WALLS TO BE DEMOLISHED. AND PROVIDE NEW OFFSETS AT CEILING ABOVE AND SLAB BELOW TO NEW STACK OR RISER LOCATION COORDINATED WITH FLOOR PLAN LAYOUT AND EXISTING CONDITIONS. 12. CONTRACTOR SHALL PROVIDE ADD ALTERNATE TO REPLACE EXISTING INSULATION ON EXISTING DOMESTIC HW PIPING. SHOWN ON THIS DRAWING AS EXISTING TO REMAIN.IN AREAS OF WORK EXPOSED BY CONSTRUCTION. REVIEW INSULATION CONDITIONS WITH OWNER'S REPRESENTATIVE, AND REPLACE EXISTING INSULATION AS DIRECTED. KEYED NOTES: O CONNECT 3 /4CW TO EXISTING CW PIPING IN THIS AREA. CONTRACTOR SHALL FIELD VERIFY EXACT TIE -IN LOCATION IN FIELD. O CONNECT 2'V TO EXISTING VENT PIPING IN THIS AREA. CONTRACTOR SHALL FIELD VERIFY EXACT TIE -IN LOCATION IN FIELD. NEW CONSTRUCTION LE:GE D SYMBOL DESCRIPTION 01/18/12 EXISTING TO REMAIN Revised: NEW CONSTRUCTION �---� CONNECT TO EXIST. AT OINT KEYPLAN ■ N 3rd Floor Level W co A Co v, os a Q 0 U� M u_ LL Ww 0 w 0 g L Ui W co U� d W W S EllF i Smith xSeckman Reid, Inc. 600 West Hillsboro, Suite 300 Deerfield Beach, FL 33441 (954) 421 -1260 FAX: (954) 421 -1466 www.ssr - inc.com Firm Cetir>mson - EB-0000857 DecnkMds FE-UM ZA.xxY w r PE -anw MYhsd&St and PE -65701 SsR JOB * 118M.o im O U z J Q U H W co I- O MTM �_ C0 LL � a CO w � V O � o W Ito I=— = w Z J W O W Q Cl) z � v_� z o QOo0 0 m C) (0 o Comm. No: 11087,00 Date: 01/18/12 Drawn: Revised: ill {111 No 3 ap E OF FjlJiFll111 P2.3