Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
12-509-039
SECOND FLOOR PLAN - NEW CONSTRUCTION - PLUMBING N rl'rli I 0' 1' 2' 4' 8' 12' GENERAL NOTES: - - - - M1= I CONTRACTOR SHALL PATCH WALLS. FLOORS AND CEILINGS TO MATCH --- ^ - EXISTING FINISHES FOR DEMOLITION AND INSTALLATION OF PIPING. FIXTURES, EOUIPMENT, ETC UNLESS NOTED OTHERWISE ON ARCH, JDRAWINGS..,, r n THE HOSPITAL IS OPEN 24 HOURS A DAY, 7 DAYS A^ WEEP. THE. - CONTRACTOR SHALL HAVE TO PERFORM WORK WITHIN ACTIVE PAT[*--I!-T- CARE - AREAS. ^^ ^ CONTRACTOR SHALL: A. COORDINATE SHUTDOWN OF EXISTING SYSTEMS WELL IN ADVANCE WITH OWNER. B. PERFORM WORK AT SUCH TIMES AND UNDER SUCH CONDITIONS AS PRESCRIBED BY OWNER. C. PERFORM WORK WITHIN THE GUIDELINES OF THE ICRA REPORT PREPARED FOR THIS PROJECT BY THE OWNER. D. SEOUENCE DEMOLITION AND NEW CONSTRUCTION TO MINIMIZE NUMBER & DURATION OF SHUTDOWNS REQUIRED. 3. CONTRACTOR SHALL COORDINATE WORK WITH EXISTING CONDITIONS (STRUCTURE. DUCTWORK. PIPING, CONDUIT. ETC.). PROVIDE OFFSETS AS REOUIRED TO INSTALL NEW WORK. 4. CONTRACTOR SHALL LOCATE ALL NEW VALVES AT ACCESSIBLE LOCATIONS. PROVIDE ACCESS PANELS. AS REQUIRED, FOR VALVES LOCATED ABOVE HARD CEILINGS. 5. ALL WASTE. STORM AND CONDENSATE PIPING 2' & LESS TO BE SLOPED Q ' /4 /FT. ALL WA�TE. STORM AND CONDENSATE PIPING 2'/J& LARGER TO BE SLOPED o /8 /FT. 6. WORK MAY NOT BE LIMITED TO SCOPE OF WORK OR PHASING AREAS INDICATED. BUT ALSO MAY INCLUDE WORK OUTSIDE OF THE SCOPE OF WORK OR PHASING AREAS AS INDICATED BY CONTRACT DOCUMENTS. 7. CONTRACTOR SHALL FIELD VERIFY WITH HOSPITAL LOCATION OF EXISTING SERVICE VALVES FOR SHUTDOWN OF CW AND HW. COORDINATE TIMING. DURATION AND AREA AFFECTED BY SHUTDOWN WITH HOSPITAL. 8. CONTRACTOR SHALL LABEL EXISTING PIPING SHOWN TO REMAIN WITHIN AREA OF WORK PER SPECIFICATIONS. 9. PIPING SHOWN IS ROUTED AT SECOND FLOOR CEILING UNLESS NOTED OTHERWISE. 10. CONTRACTOR SHALL OFFSET NEW WASTE PIPING DROPS AS REOUIRED TO AVOID STRUCTURAL JOISTS. H. CONTRACTOR TO REMOVE EXISTING STACKS AND RISERS LOCATED IN EXISTING WALLS TO BE DEMOLISHED. AND PROVIDE NEW OFFSETS AT CEILING ABOVE AND SLAB BELOW TO NEW STACK OR RISER LOCATION COORDINATED WITH FLOOR PLAN LAYOUT AND EXISTING CONDITIONS. 12. CONTRACTOR SHALL PROVIDE ADD ALTERNATE TO REPLACE EXISTING INSULATION ON EXISTING DOMESTIC HW PIPING. SHOWN ON THIS DRAWING AS EXISTING TO REMAIN.IN AREAS OF WORK EXPOSED BY CONSTRUCTION. REVIEW INSULATION CONDITIONS WITH OWNER'S REPRESENTATIVE, AND REPLACE EXISTING INSULATION AS DIRECTED. KEYED NOTES: O CONNECT 3'W TO EXISTING WASTE PIPING IN THIS AREA. CONTRACTOR SHALL FIELD VERIFY EXACT TIE-IN LOCATION IN FIELD. NEW CONSTRUCTION LEGEND SYMBOL DESCRIPTION Drawn: EXISTING TO REMAIN Revised: NEW CONSTRUCTION �--� CONNECT TO EXIST. AT THIS POINT KEYPLAN N 2nd Floor Level >— W 01/18/12 Drawn: Revised: O'• CD co co v, 0. a UM 0 M J Q � u_ w 0 it W 0 g Q _ T i N I� U act NN I..L : U M W 0 U 3 � 0 z o o S _W LL u_ i U) xii� o Smith eckman Reid, Inc. 600 West Hillsboro, Suite 300 Deerfield Beach, FL 33441 (954) 421 -1260 FAX: (954) 421 -1466 www.ssr- inc.com Firm Celtir=HM - EBA1000857 D®iD.A Pe -66668 J.L.Lx..Id� FE.8= 1fid.W&SW-1d PE -66701 SM JOB * 1132069.0 0 M Q Z J Q U H W H Qo r 0_ M J 0 ILL LL w 0 1- 2) Cr) a o 0 C0 co a J = w oc W � CO =QMcr z (L O Q000 m 0) O O Comm. No: 11087.00 Date: 01/18/12 Drawn: Revised: 0 �KiBU� , No. 3320 F: O'• 0. '� '•...... ••'-a� © � •t lla7�i�n1t%- P2.1