12-509-033PLUMBING FIXTURE SCHEDULE rt (CONTRACTOR SHALL COORDINATE ALL PLUMBING REQUIREMENTS WITH FINAL OWNER FURNISHED EQUIPMENT BROCHURE) FIXTURE FITTING FLOOR OISCRPTIN C.IL ILI. DL p BASTE REMARKS OFCI EOUIPMENT BOOM MOUNTED P.W C.W H.W. WASTE REMARKS MANUFACTURER MODEL TYPE SIZE MANUFACTURER TYPE SUPPLY TRAP FAUCET SYMBOL CARRIER - SHUTOFF VALVE MODEL •FRM1812S. COORDINATE MOUNTING HEIGHT WITH EOUIPMENT. LINE PRESSURE ALARM PANEL 1 (1)02. (1)N20. (DA, (I)V. (i)CA. (3)SPARE P_3 (PUBLIC) WELLWORTH K -4406 FLUSH VALVE FLOOR MOUNTED ELONGATED SLOAN ROYAL ' Ill- 1.28 -TD YBYC NA INTEGRAL NA NA __ I• __ 4• K-4670G WHITE SEAT, SO-2 BACKFLOW PREVENTER BETWEEN SHUTOFF VALVE AND EOUIPMENT WATER WATER CLOSET W 1.28 GALLON VITREOUS CHINA BOWL HUB DRAIN FLUSH VALVE MECH. ROOMS CONNECTOR. AIR DRYERS 120V. MOUNT IS' A.F.F. AFF FLUSH VALVE Y' FIRE RATED AL WHITE WALL X NI H 72 OB NOISE SHUTOFF VALVE MODEL •FRM1812S. COORDINATE MOUNTING HEIGHT WITH EOUPMENT. 0088 P -3A KOHLER (PUBLIC) HIGHLINE FLOOR MOUNTED ELONGATED ' SLOAN ROYAL ' 111 - 1.28 -TD YBYC NA INTEGRAL NA NA -- 1• -- 4• K -4670C WHITE SEAT, WATER CLOSET -HC K -4405 VITREOUS CHINA BOWL FLUSH VALVE CONNECTOR. MOUNT (HC) 18' A.F.F. 1.28 GALLON PROVIDE SHUTOFF VALVE (ACCESSIBLE PER EO.MANUF.GUIDELINES) AND UNION AT P -6A URINAL (HC) URINAL BARDON •K- 4960 -ET WALL HUNG NA SLOAN ROYAL '186 -0.5 NA INTEGRAL NA ZURN 21221 -- 3 /; __ 2• MOUNT 17' A.F.F. 0.5 GALLON VITREOUS CHINA PROVIDE DEARBORN BRASS •814 BRANCH TAIL PIECE WITH SIDE INLET. INSTALL IN SINK ADJACENT TO STERILIZER.& ROUTE WASTE FROM STERILIZER TO TO RIM 5' BACKSPLASH CONNECTION OF TAILPIECE. PROVIDE WITH AR GAP FITTING. ROUTE WASTE FROM CHICAGO FAUCET P -13A KOHLER (HC) KINGSTON WALL HUNG CONCEALED ARM 21' X 18' McGUIRE 8155WC GRID DRAIN WITH PROWRAP H -2165 88902 I'/Z INLET 70 1'/J- P -TRAP 3895- 31TE2805 "5CP WRSTBLAOE HANDLE. ZURN , /i , /f , t/f MOUNT 34' A.F.F. TO RIM. LAVATORY K-2005 VITREOUS CHINA 4• FAUCET CTR 'PW2125 -WC O SET FOR WHEEL COORDINATE OS GPM NON AERATOR FLOW CONTROL Z -1231 CHAIR USE DEVICE WITH MFGR. CHICAGO FAUCET COORDINATE HOLE CORIAN COUNTERTOP WITH 9155WC GRID DRAIN 08902 1'/Z INLET TO 0895- 3ITE2805 -5CP PUNCHES FOR FAUCET P -14 INTEGRAL SINK SPECIFIED McGUIRE WITH PROWRAP H -2165 11/ OUTLET P -TRAP OFFSET FOR WHEEL WRISTBLADE HANDLE. COORDINATE OS GPM NON NA __ , /f 1 /f ti /i WITH COUNTERTOP BY ARCHITECT 'PW2125 -WC CHAIR USE AERATOR FLOW CONTROL BY ARCHITECT PRIOR DEVICE WITH MFGR. TO FAUCET PURCHASE JUST - (STAFF) 'SL-ADA- SINGLE COMP. PROWRAP PROWRAP •PW2150 CHICAGO FAUCET P -20A S.S. SINK 2019-A -GR (S.S.) 18 GAUGE 14' X 16' X 61/2 McGUIRE EPW1151WC H -2165 It /2 P -TRAP OFFSET 8786- GN2FCCP NA -- yf '/f tyf ADA SELF- RIMMING OFFSET STRAINER FOR WHEEL CHAIR USE (1.5 GPM) JUST - (STAFF) 'SL -ADA- SINGLE COMP. PROWRAP PROWRAP OPW2150 CHICAGO FAUCET ZURN 'Z -1236 P -20B S.S. SINK 2019 -A -GR (S.S.) 18 GAUGE 14• X 16' X 61/2 McGUIRE ■PWI152WC H-2165 11/2 P -TRAP OFFSET 0786- GN2FCCP WITH 11' LONG -- '/f '/i I' /i ADA SELF - RIMMING OFFSET STRAINER FOR WHEEL CHAIR USE (1.5 GPM) ARM P -34 STERN - WILLIAM SB- 900 -BP WITH STAINLESS STEEL CAP & 3' 24' X 24' X 12' GUARDIAN EYE WASH/ DRENCH HOSE NA NA CHICAGO FAUCET NA __ I/2 I/f 3. STAINLESS STEEL FLOOR BASIN CHROME DRAIN. G50468P '897 -CP BACK PANEL DOUBLE COMPARTMENT SCRUB SINK WITH KNEE CONTROLS. COORDINATE FLOOR P -26B OWNER FURNISHED CONTRACTOR INSTALLED. H -2165 12)'8912 NA ZURN 21236 -WS __ (2) yf (2) '/1 (2)11& MOUNTED CARRIER WITH HJCT ED. 8018 McGUIRE NA 11/2 P -TRAPS FINAL OWNER SELECTION. P -42 SHOWER TILE ZURN NA NA WITH INTREGRAL NA SYMMONS •l- 1170VT- H401 -V -X -830 NA -- '/i '/f A A. PROVIDE ALSONS 0476PK FOR VOLUME SPEC BY ARCH. ZN415 -B NA NA STOPS SET TO 1.5 GPM WITH 2' CONTROL OF HAND 30' SLOE BAR SHOWER. SIZE AS REQUIRED TO P -58 P.P.P. PRIME -RITE PR -500 NA NA NA NA NA NA NA NA "" , /z -- -" SERVE NUMBER OF TRAP PRIMER DRAIN P -62B CHICAGO FAUCET MODEL 9952 -CP HOSE BIBB NA NA NA NA NA NA NA y2 __ -- NA NOTES: I. INSTALLATION OF FIXTURES SHALL BE FULLY COORDINATED WITH GRAB BARS. PROVIDE FLUSH VALVES WITH OFFSETS AS REQUIRED. 2. PROVIDE SYMMONS THERMOSTATIC MIXING VALVE 85-210-CK 1/2 GPM MIN. 2 GPM MAX ON P -13A. P -14. P -20A &', P -20B FAUCETS. SET AT 110'F. SEE DETAILS. INSTALL PER MANUFACTURERS WRITTEN INSTRUCTIONS. 3. CONTRACTOR SHALL PROVIDE ALL REOUIRED MATERIAL FOR A COMPLETE INSTALLATION OF THE PLUMBING FIXTURES INCLUDING ANY GROUT AS REOUIRED AT WALL HUNG FIXTURES. COORDINATE WITH ARCHITECT FOR SPECIFIC GROUT REQUIREMENTS. OWNER FURNISHED EQUIPMENT (CONTRACTOR SHALL COORDINATE ALL PLUMBING REQUIREMENTS WITH FINAL OWNER FURNISHED EQUIPMENT BROCHURE) HJCT EOUWENT NO. EOLO MENT VENDOR NO. LOCATION OISCRPTIN C.IL ILI. DL CA BASTE REMARKS OFCI EOUIPMENT BOOM ZN- 415 -6B -P (002. (DA. (3)V. (3)SL GENERAL DELIVERY ROOM. CA OPERATES ZURN TRAP PRIMER NON THE BRAKING SYSTEM. PROVIDE •GUY GREY• FIRE RATED METAL WHITE PONDER COATED WALL BOX WITH 006 FD-2 SEE PLANS COFFEE MAKER O - - - - SHUTOFF VALVE MODEL •FRM1812S. COORDINATE MOUNTING HEIGHT WITH EOUIPMENT. LINE PRESSURE ALARM PANEL 1 (1)02. (1)N20. (DA, (I)V. (i)CA. (3)SPARE NURSE'S STATION ZURN R DRAM 'Z550 -G -P GALVANIZED CAST IRON AS SHOWN 9• DOA. MEDIUM DUTY COORDINATE INSTALLATION OF EOUIPMENT WGR. RECOMMENDED FILTER AND WATTS INSTRUMENT DRAIN WITH TRAP PRIMER RECEIVER. PROVIDE CAST IRON SO-2 BACKFLOW PREVENTER BETWEEN SHUTOFF VALVE AND EOUIPMENT MIN V AF.F HD-1 -- - --- ----------- HUB DRAIN 3' MECH. ROOMS CONNECTOR. AIR DRYERS 120V. Y' FIRE RATED AL WHITE WALL X NI H 72 OB NOISE SHUTOFF VALVE MODEL •FRM1812S. COORDINATE MOUNTING HEIGHT WITH EOUPMENT. 0088 SEE �/{ - - COORDINATE INSTALLATION OF EOLIPMENT MIFGR.RECOMMENDED FILTER AND WATTS SO -2 BACKFLOW PREVENTER BETWEEN SHUTOFF VALVE AND EOUPMENT CONNECTOR. PROVIDE SHUTOFF VALVE (ACCESSIBLE PER EO.MANUF.GUIDELINES) AND UNION AT EACH UTILITY SUPPLY CON)ECTKOL PROVIDE WATTS 009 RPBP AND SHUTOFF 034 SEE PLANS FLASH STERILIZER - '/f 'W PROVIDE DEARBORN BRASS •814 BRANCH TAIL PIECE WITH SIDE INLET. INSTALL IN SINK ADJACENT TO STERILIZER.& ROUTE WASTE FROM STERILIZER TO CONNECTION OF TAILPIECE. PROVIDE WITH AR GAP FITTING. ROUTE WASTE FROM RPBP TO SPILL OVER MOP SINK IN ADJACENT ROOM WITH CHROME PLATED ESCUTCHEON AT CEILING PENETRATION. GENERAL NOTES. I. PPE SIZES SHOWN ARE CONNECTION SIZES AT EOUIPMENT. BRANCH LINES TO EOUIPMENT SHALL BE ONE PPE SIZE LARGER THAN EOUIPMENT CONNECTION SIZE UNLESS OTHERWISE NOTED ON PLANS. 2. ALL STERLIZNG EQUIPMENT AND ASSOCIATED COMPONENTS TO BE INSTALLED BY THE EOUIPMENT SUPPLIER. 3. SEE MEDICAL GAS SCHEDULE FOR MEDICAL GAS OWNER FURNISHED EOUPMENT. 4. PROVIDE BACKFLOW PREVENTER AT EACH CONNECTION OF POTABLE WATER TO EOUIPMENT N ACCORDANCE WITH FBC 2007. SECTION 608. S. PROVIDE SHOCK ABSORBERS AT ALL CW & HW EOUIPMENT CONNECTIONS. L SEE EOUIPMENT DRAWINGS FOR LOCATIONS OF EOUIPMENT. T. COORDINATE INSTALLATION OF FILTERS WITH CASEWORK AND EOUPMENT.PROVIDE CLEARANCES TO ALLOW FILTER SERVICE PER FILTER MFGR. L PROVIDE PRESSURE REGULATOR AT EACH EOUIPMENT CONNECTION AS REOUIRED TO REDUCE INLET PRESSURES TO MANUFACTURER GUIDELINES. 9. NOT WATER TEMPERATURE IS 120• F. UNLESS OTHERWISE NOTED. 10. COORDINATE ALL EOUPMENT SERVICE CONNECTIONS AND THEIR ROUGH -N LOCATIONS WITH FINAL VENDOR EOUIPMENT DRAWINGS. REPORT ANY DISCREPANCIES WITH ARCH/ENGR. 11. PROVIDE SHUT OFF VALVE AT ALL SERVICE CONNECTORS TO EACH PIECE OF EOUIPMENT. MEDICAL GAS SCHEDULE SYMBOL DESCRIPTION HJCT EQUIP, N0. EQUIPPED WITH REMARKS O ZONE VALVE BOX I 1 /ZCA. /202.1 /¢N20.3 / ;A.1' / ;V GENERAL DELIVERY ROOM 0 OFCI EOUIPMENT BOOM ZN- 415 -6B -P (002. (DA. (3)V. (3)SL GENERAL DELIVERY ROOM. CA OPERATES ZURN TRAP PRIMER NON THE BRAKING SYSTEM. OC OFCI ANESTHESIA BOOM FD-2 12)02. (I)N20. (DA, (3)V. (I)WAGD. (3)SL GENERAL DELIVERY ROOM. FRICTION BRAKES. O WALL OUTLETS 9"M HEAVY DUTY (3)02. (3)A. (3)V. (3)SL GENERAL DELIVERY ROOM (BASSINET) O LINE PRESSURE ALARM PANEL 1 (1)02. (1)N20. (DA, (I)V. (i)CA. (3)SPARE NURSE'S STATION NOTES: 1• CONTRACTOR SHALL PROVIDE PERMANENTLY ENGRAVED LABELS AT ALL ZONE VALVE BOXES AND ALARM PANELS IDENTIFIED ABOVE IN SCHEDULE, TO INDICATE SPECIFIC ROOMS SERVED. COORDINATE LABELING WITH FINAL ROOM NAMES AND NUMBERS, AND AREA SERVED WITH HOSPITAL. NOTE ALARM PANEL ALSO SERVES EXISTING C- SECTION ROOMS. 2. PROVIDE PERMANENT ENGRAVED LABELS AT ALL ALARM PANELS, IDENTIFIED ABOVE IN SCHEDULE, INDICATING ELECTRICAL LIFE SAFETY CIRCUIT FEE ING ALARM PANEL. 3. CONTRACTOR SHALL COORDINATE INSTALLATION OF BOOM MANUFACTURER FURNISHED CAS /VACUUM RISERS AND RISER BRACKET PER BOOM MANUFACTURER GUIDELINES. COORDINATE PIPE ROUTING WITH CEILING ACCESS PANELS TO ALLOW ACCESSIBILTY. EOUIPMENT BOOM HAS PNEUMATIC BKAKES; COORDINATE PRESSURE REGULATING VALVE (VFCOINSTALLATION AND PRESSURE SETTING WITH BOOM MANUFACTURER. .. PLUMBING DRAIN SCHEDULE SYMBOL ITEM WASTE REMARKS MANUFACTURER MODEL TYPE H.P. DESCRp• EACH FD -1 ZURN FLOOR DRAIN ZN- 415 -6B -P POLISHED NICKEL BRONZE TOP AS SHOWN IN PLAN ZURN TRAP PRIMER NON P- OPTION FD-2 ZURN R DRAIN 'Z520 -G -P I GALVANIZED CAST ANTS SHOWN PLAN 9"M HEAVY DUTY HIGH PRESSURE DRAIN WITH TRAP PRIMER FD -3 ZURN R DRAM 'Z550 -G -P GALVANIZED CAST IRON AS SHOWN 9• DOA. MEDIUM DUTY DUPLEX PUMP PKG W/ 80 GAL INSTRUMENT DRAIN WITH TRAP PRIMER RECEIVER. PROVIDE CAST IRON MIN V AF.F HD-1 -- - --- ----------- HUB DRAIN 3' MECH. ROOMS OMPRESSED AIR EQUIPMENT SCHEDULE ITEM MANUFACTURER S.C.F.M.O 145 Psig VOLTAGE H.P. DESCRp• EACH TOTAL EACH TOTAL & MODEL NO. NON MEDICAL AIR POWEREX HIGH PRESSURE COMPRESSOR NICU O.R. MSD- MT- 0503HP SCROLL TYPE 12.5 12.5 460 5 10 DUPLEX PUMP PKG W/ 80 GAL INSTRUMENT RECEIVER. PROVIDE AIR W/ (2) DESICCANT AIR DRYERS 120V. 72 OB NOISE LEVEL NOTE: 1. TOTAL COMPRESSED AIR SCFM IS BASED ON I OF 2 COMPRESSORS RUNNING. 2. AIR COMPRESSOR CONTROL PANEL SHALL HAVE CAPABILITY TO MONITOR LOCAL ALARM POINTS AS REOUIRED BY NFPA 99. 3. PROVIDE WITH AUTOMATIC RESET UPON LOSS OF POWER. 4. PROVIDE WITH DRY CONTACTS FOR CO. DEW POINT, GENERAL FAULT HAT AND LOG IN USE ALARM. IMAI 11 1