12-509-028REMOVABLE FAN HOUSING SEE NOTE 2- � SPUN ALUMINUM CAP / BIRDSCREENJ 1`_ 0 SECURE FAN TO CURB WITH STAINLESS STEEL SCREWS AT 12' ON CENTERS, ALL SIDES — N 0 T E S: NON -FUSED DISCONNECT SWITCH -_ i MOTOR 'OUT OF AIR STREAM' ROUTE POWER LEADS TO FAN INSIDE CORNER OF CURB 1. BELT DRIVEN CENTRIFUGAL EXHAUSTER SHOWN , DETAIL IS SIMILAR FOR DIRECT DRIVE CENTRIFUGAL EXHAUSTER. DETAIL ALSO APPLIES TO UPBLAST ROOF EXHAUSTER. (PROVIDE VENTED CURB PER NFPA 96) 2. REFER TO ARCHITECTURAL DRAWINGS FOR ADDITIONAL BRACING AND TIE -DOWN REQUIREMENTS. POWER ROOF EXHAUSTER (P.R.E.) S SLIP OR U CLIP OPTIONAL ALL SUCH CONNECTIONS TO \\ \ w = 4' MIN. BE SEALED ii I! VOLUME DAMPER II �� II II � li VOLUME--' SQUARE THROAT \ ELBOW OPTIONAL 11 VOLUME DAMPER D i D2= 4' MIN. D3= 4' MIN. NOTE: VOLUME CONTROL SHOULD BE BY BRANCH DAMPERS. IF A SPLITTER IS SHOWN IN THE DESIGN ITS LENGTH SHOULD BE 1.5 W OR 1.5 D3. PARALLEL FLOW BRANCHES PROVIDE MANUAL AIR VENT AT HIGH POINT OF RISERS. ! t CIS CHR 'TAP -OUT' EITHER SIDE OR BOTTOM OF DUCT. TOP 'TAP- OUT'IS NOT ACCEPTABLE THERMAFLEX 8M OR FLEXMASTER M -KE & INSULATED FLEX DUCT, U.L. LISTED 6' MIN. . t NOTE 0 G SUPPLY DUCT — BELLMOUTH OR 45' THROAT TAP W/ SQUARE TO ROUND TRANSITION SECURING STRAP PANDUIT (OR EQUAL) SHEET METAL SCREW (TYPICAL) SUPPLY DIFFUSER WITH INSULATED BACK PANEL FOLLOW MFR'S INSTRUCTIONS FOR INSTALLATION OF SUPPLY DIFFUSER IN CEILING DUCTWORK CONNECTION TO SUPPLY DIFFUSER (FLEX DUCT) VOL DAM AIR FLOW l NOTE: 1. TRANSITION TO MAKE EQUAL ELL'S. LOW PRESSURE DUCT TEE DETAIL WATER SHALL — ENTER COIL ON AIR LEAVING SIDE. MAKE SUPPLY DUCT INSULATION CONTINUOUS OVER REHEAT COIL DUCTWORK _- — - La' rREHEAT SEE HOT WATER PIPING DETAIL COIL 18x18 SIDE ACCESS DOOR OR AS LARGE AS DUCT WILL ALLOW. INSTALL ACCESS DOOR IN BOTTOM OF DUCT IF SIDE ACCESS IS NOT AVAILABLE. \-PETCOCK LINE SIZE (TYP) DIRT LEG CONNECTION SIZE - 1/¢ MIN. DRAIN N 0 T E U VALVE. PIPE TO FLOOR DRAIN. USE LARGER OF SIZE SHOWN ON DRAWING TRANSITIONS FROM COIL SIZE TO DUCT SIZE V SHALL NOT EXCEED 30. ON ENTERING SIDE HOSE END OR COIL CONN. SIZE (TYPICAL) AND 45. ON LEAVING SIDE. TE VALVE CHILLED WATER PIPING DUCT MOUNTED HOT WATER AT SINGLE COOLING COIL REHEAT COIL 'TAP -OUT' EITHER SIDE OR BOTTOM OF DUCT. TOP 'TAP -OUT' IS NOT ACCEPTABLE THERMAFLEX 8M OR FLEXMASTER M -KE & INSULATED FLEX DUCT, U.L. LISTED 24 GA. INSULATED '• GALVANIZED C RETURN SHEET METAL BOX L UCT BELLMOUTH OR 45' THROAT TAP W/ _T SQUARE TO ROUND TRANSITION SECURING STRAP 6' MIN. PANDUIT (OR EQUAL) VOLUME DAMPER REQUIRED WHERE DAMPER AT DUCT BRANCH IS INACCESSIBLE. CEILING RETURN REGISTER NOTE: INSULATE RETURN DUCTWORK PER SPECS. DUCTWORK CONNECTION TO RETURN GRILLE (FLEX DUCT) INSULATION NOTE: CUT INLET AND EXHAUST TUBES TO LENGTH SPECIFIED AIR FLOW BY MANUFACTURER DIRECTION 12x12 MINIMUM SIZE DUCT ACCESS DOOR NOTES: RUBBER PLUG TUBE SHALL PENETRATE DUCTS MORE THAN 36' WIDE DUCT INLET TUBE HOLES FACE UPSTREAM OF AIR FLOW C HAUST TUBE 24 GA. METAL INSULATION STANDOFF NOTE 2 SMOKE DETECTOR HOUSING MOUNTED TO SIDE OF DUCT 1. DETAIL SHOWS GENERAL INSTALLATION METHODS. REFER TO INDIVIDUAL MANUFACTURER FOR THEIR SPECIFIC INSTALLATION AND LOCATION INSTRUCTIONS. 2. STANDOFF BRACKET NOT REQUIRED ON NON- INSULATED DUCT. DUCT MOUNTED SMOKE DETECTOR PETE'S PLUG 3/1 BALL VALVE • vruT WAY CONTROL VALVE -WAY CONTROL VALVE ..,.,,w.. ,,...,. 1NW. ..r .... �m w . nv • �.• v��r..• . . . wvnu.v NOTE: PIPING SAME FOR HEATING COIL IN HOT WATER REHEAT TERMINAL BOXES AND FOR DUCT MOUNTED HOT WATER HEATING COILS. PIPING AT REHEAT COIL EFER TO BOX CHEDULE FOR UNOUT PIPE IZES. �.ywR **'S 'TAP -OUT' EITHER SIDE OR BOTTOM OF DUCT. TOP 'TAP- OUT' IS NOT ACCEPTABLE SHEET METAL RIGID ELBOW (NO FLEXIBLE DUCT ALLOWED) MAIN SUPPLY RETURN OR TYPICAL MANUAL EXHAUST DUCT EXHAUST VOLUME DAMPE PRE MANUFACTURED DUCT 45' TAKEOFF WITH 24 GA. GALVANIZED GASKET FLANGE & SHEET METAL BOX VOLUME DAMPER SIMILAR TO CROWN A5' _j m MODEL 3300 -DS EL SHOE TAP WITH Ni BALANCE DAMPER 6' MIN. W i _ I USE THIS WITH RECTANGULAR DUCT TAKEOFF - SMACNA 45° USE THIS WITH ENTRY FITTING: ROUND DUCT L =1/4 W, (4' MIN.) TAKEOFF'S (MAY ALSO BE PARALLEL FLOW FITTING) CEILING EXHAUST GRILLE = BRANCH TO INDIVIDUAL DIFFUSER OR GRILLE = SUBMAIN, BRANCHMAIN . OR BRANCH. NOTE: FLEXIBLE DUCT IS NOT ALLOWED FOR EXHAUST DUCTWORK. DUCTWORK CONNECTION TO LOW PRESSURE DUCT VOLUME DAMPER EXHAUST GRILLE (RIGID DUCT) REQUIREMENTS DAMPER OPERATOR 4MS ' TED WITH END SWITCHK SIDE OR BOTTOM MOUNTED, NOT ORATED WALL OR PARTITION TOP OPENING IN STUD WALL FOR DUCT OPENING IN STUD WALL FOR DUCT PENETRATION SHALL HAVE A STUD PENETRATION SHALL HAVE A STUD FRAME ON ALL SIDES. RETAINING FRAME ON ALL SIDES. RETAINING ANGLE SHALL BEAR ON STUD FRAME. ANGLE SHALL BEAR ON STUD FRAME RATED WALL OR PARTITION DUCT TRANSITION TRANSITION CONNECT SLEEVE TO DUCT DAMPER BLADE ASSEMBLY WITH SLIP JOINT CONNECT SLEEVE TO SLE VE SHALL EXTEND A MAX. y WITH U.L. LISTED 165 °F WITH SLIP -JOINT 6' BIfYOND WALL. EACH SIDE FUSABLE LINK TRANSITION AR ACCESS DOOR ON SAME DUCT DUCT FLOW SIDE AS OPERATOR. REFER TO SPEC'S FOR SEE NOTE 4 DOOR TYPE AND SIZE 11/¢ x 11/1 x I/d DUCT RETAINING ANGLE VOIDS BETWEEN WALL AND SEE NOTE DAMPER SLEEVE SHALL BE TRANSITION LEFT OPEN SO AS NOT TO INTERFERE WITH EXPANSION. DAMPERS SHALL BE 11/2 HOUR RATED UNDER IIR x 11/¢ x 1/9 114 TO /¢ EXPANSION! U.L. STANDARD 555 AND QUALIFIED UNDER RETAINING ANGLE ACCESS DOOR IN DUCT. CLEARANCE. SEE NOTE U.L. 555 S AS A TYPE 2 LEAKAGE RATED SEE NOTE REFER TO SPECIFICATIONS SMOKE DAMPER. SEE SPECIFICATIONS SECTION FOR DOOR TYPE AND SIZE i FOR MODEL NUMBERS. NOTES: NOTES: 1. PROVIDE U.L. LISTED DAMPER, SLEEVE & OPERATOR ASSEMBLY IN ACCORDANCE WITH U.L. 555 AS A SINGLE ENTITY. I. PROVIDE U.L. LISTED DAMPER AND SLEEVE IN ACCORDANCE WITH U.L. 555 AS A 2. INSTALL DAMPER AND SLEEVE IN ACCORDANCE WITH MANUFACTURER'S SINGLE ENTITY. INSTRUCTIONS NOT TO VOID U.L. LISTING. 2. INSTALL DAMPER AND SLEEVE IN ACCORDANCE WITH MANUFACTURER'S 3. EXTEND SLEEVE BEYOND WALL A MAX. 6 INCHES AND MOUNT OPERATOR ON INSTRUCTIONS NOT TO VOID U.L. LISTING. SLEEVE. 3. EXTEND SLEEVE BEYOND WALL MAX. 6 INCHES. 4. PROVIDE EXPANSION SPACE PER MANUFACTURER'S INSTRUCTION, BUT NOT LESS 4. PROVIDE EXPANSION SPACE PER MANUFACTURER'S INSTRUCTION, BUT NOT LESS THAN 1/d PER LINEAR FOOT. THAN I/d PER LINEAR FOOT, BOTH DIRECTIONS. 5. PROVIDE MINIMUM 1f¢ x III 1/¢ RETAINING ANGLE ON TOP. BOTTOM &SIDES. 5. PROVIDE MINIMUM 11/¢ x 11/¢ x I/d RETAINING ANGLE ON TOP, BOTTOM, AND SIDES. ATTACH ANGLES To SLEEVE IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. ATTACH ANGLE TO SLEEVE IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. DAMPER SHALL BE SELF SUPPORTING, INDEPENDENT OF DUCTWORK, ANGLES SHALL DAMPER SHALL BE SELF SUPPORTING, INDEPENDENT OF DUCTWORK. ANGLES SHALL OVERLAP WALL A MINIMUM OF ONE INCH. OVERLAP WALL A MINIMUM OF ONE INCH. 6. INSTALL A MINIMUM OF 5 FEET OF SHEETMETAL DUCTWORK ON BOTH SIDES 6. INSTALL A MINIMUM OF 5 FEET OF SHEETMETAL DUCTWORK ON BOTH SIDES OF THE RATED WALL PRIOR TO ANY DUCTWORK TRANSITIONS. OF THE RATED WALL PRIOR TO ANY DUCTWORK TRANSITIONS. COMBINATION FIRE /SMOKE FIRE DAMPER AT RATED WALL DAMPER AT RATED WALL EXISTING HVAC WATER PIPING - CONNECT TO EXISTING SYMBOL LINE SIZE SHUTOFF VALVES EW MAINS TO TEMPORARY FLUSHING LOOP, CONNECTION ONE SIZE EW EQUIPMENT SMALLER THAN LINE SIZE. REMOVE AND CAP WHEN SYSTEM IS PROVEN CLEAN FROM FLUSHING. HOSE END DRAIN VALVE SCHEDULE BUTTERFLY VALVE (TYPICAL). DRAIN VALVE SIZE BALANCING BALL VALVES ON SMALLER 21/¢ TO 4' VALVE (TYP) SIZES. (SEE SPECS.) 2' B &G CIRCUIT -1G SETTER, OR PETE'S TEST PLUG (TYPICAL) EQUAL THERMOMETER (TYPICAL) OFFSET PIPING AS SHOWN TO ALLOW COIL PULL WITHOUT DUCTWORK CONTROL VALVE (2 -WAY) DISMANTLING VERTICAL RISERS. SEE 1/¢ BALL CONTROL VALVE AIR DRAWINGS VENT Y STRAINER AIR WITH BLOWDOWN� C O O L IN G FLOW VALVE C 0 IL ~ I i AIR FLOW WATER SHALL — ENTER COIL ON AIR LEAVING SIDE. MAKE SUPPLY DUCT INSULATION CONTINUOUS OVER REHEAT COIL DUCTWORK _- — - La' rREHEAT SEE HOT WATER PIPING DETAIL COIL 18x18 SIDE ACCESS DOOR OR AS LARGE AS DUCT WILL ALLOW. INSTALL ACCESS DOOR IN BOTTOM OF DUCT IF SIDE ACCESS IS NOT AVAILABLE. \-PETCOCK LINE SIZE (TYP) DIRT LEG CONNECTION SIZE - 1/¢ MIN. DRAIN N 0 T E U VALVE. PIPE TO FLOOR DRAIN. USE LARGER OF SIZE SHOWN ON DRAWING TRANSITIONS FROM COIL SIZE TO DUCT SIZE V SHALL NOT EXCEED 30. ON ENTERING SIDE HOSE END OR COIL CONN. SIZE (TYPICAL) AND 45. ON LEAVING SIDE. TE VALVE CHILLED WATER PIPING DUCT MOUNTED HOT WATER AT SINGLE COOLING COIL REHEAT COIL 'TAP -OUT' EITHER SIDE OR BOTTOM OF DUCT. TOP 'TAP -OUT' IS NOT ACCEPTABLE THERMAFLEX 8M OR FLEXMASTER M -KE & INSULATED FLEX DUCT, U.L. LISTED 24 GA. INSULATED '• GALVANIZED C RETURN SHEET METAL BOX L UCT BELLMOUTH OR 45' THROAT TAP W/ _T SQUARE TO ROUND TRANSITION SECURING STRAP 6' MIN. PANDUIT (OR EQUAL) VOLUME DAMPER REQUIRED WHERE DAMPER AT DUCT BRANCH IS INACCESSIBLE. CEILING RETURN REGISTER NOTE: INSULATE RETURN DUCTWORK PER SPECS. DUCTWORK CONNECTION TO RETURN GRILLE (FLEX DUCT) INSULATION NOTE: CUT INLET AND EXHAUST TUBES TO LENGTH SPECIFIED AIR FLOW BY MANUFACTURER DIRECTION 12x12 MINIMUM SIZE DUCT ACCESS DOOR NOTES: RUBBER PLUG TUBE SHALL PENETRATE DUCTS MORE THAN 36' WIDE DUCT INLET TUBE HOLES FACE UPSTREAM OF AIR FLOW C HAUST TUBE 24 GA. METAL INSULATION STANDOFF NOTE 2 SMOKE DETECTOR HOUSING MOUNTED TO SIDE OF DUCT 1. DETAIL SHOWS GENERAL INSTALLATION METHODS. REFER TO INDIVIDUAL MANUFACTURER FOR THEIR SPECIFIC INSTALLATION AND LOCATION INSTRUCTIONS. 2. STANDOFF BRACKET NOT REQUIRED ON NON- INSULATED DUCT. DUCT MOUNTED SMOKE DETECTOR PETE'S PLUG 3/1 BALL VALVE • vruT WAY CONTROL VALVE -WAY CONTROL VALVE ..,.,,w.. ,,...,. 1NW. ..r .... �m w . nv • �.• v��r..• . . . wvnu.v NOTE: PIPING SAME FOR HEATING COIL IN HOT WATER REHEAT TERMINAL BOXES AND FOR DUCT MOUNTED HOT WATER HEATING COILS. PIPING AT REHEAT COIL EFER TO BOX CHEDULE FOR UNOUT PIPE IZES. �.ywR **'S 'TAP -OUT' EITHER SIDE OR BOTTOM OF DUCT. TOP 'TAP- OUT' IS NOT ACCEPTABLE SHEET METAL RIGID ELBOW (NO FLEXIBLE DUCT ALLOWED) MAIN SUPPLY RETURN OR TYPICAL MANUAL EXHAUST DUCT EXHAUST VOLUME DAMPE PRE MANUFACTURED DUCT 45' TAKEOFF WITH 24 GA. GALVANIZED GASKET FLANGE & SHEET METAL BOX VOLUME DAMPER SIMILAR TO CROWN A5' _j m MODEL 3300 -DS EL SHOE TAP WITH Ni BALANCE DAMPER 6' MIN. W i _ I USE THIS WITH RECTANGULAR DUCT TAKEOFF - SMACNA 45° USE THIS WITH ENTRY FITTING: ROUND DUCT L =1/4 W, (4' MIN.) TAKEOFF'S (MAY ALSO BE PARALLEL FLOW FITTING) CEILING EXHAUST GRILLE = BRANCH TO INDIVIDUAL DIFFUSER OR GRILLE = SUBMAIN, BRANCHMAIN . OR BRANCH. NOTE: FLEXIBLE DUCT IS NOT ALLOWED FOR EXHAUST DUCTWORK. DUCTWORK CONNECTION TO LOW PRESSURE DUCT VOLUME DAMPER EXHAUST GRILLE (RIGID DUCT) REQUIREMENTS DAMPER OPERATOR 4MS ' TED WITH END SWITCHK SIDE OR BOTTOM MOUNTED, NOT ORATED WALL OR PARTITION TOP OPENING IN STUD WALL FOR DUCT OPENING IN STUD WALL FOR DUCT PENETRATION SHALL HAVE A STUD PENETRATION SHALL HAVE A STUD FRAME ON ALL SIDES. RETAINING FRAME ON ALL SIDES. RETAINING ANGLE SHALL BEAR ON STUD FRAME. ANGLE SHALL BEAR ON STUD FRAME RATED WALL OR PARTITION DUCT TRANSITION TRANSITION CONNECT SLEEVE TO DUCT DAMPER BLADE ASSEMBLY WITH SLIP JOINT CONNECT SLEEVE TO SLE VE SHALL EXTEND A MAX. y WITH U.L. LISTED 165 °F WITH SLIP -JOINT 6' BIfYOND WALL. EACH SIDE FUSABLE LINK TRANSITION AR ACCESS DOOR ON SAME DUCT DUCT FLOW SIDE AS OPERATOR. REFER TO SPEC'S FOR SEE NOTE 4 DOOR TYPE AND SIZE 11/¢ x 11/1 x I/d DUCT RETAINING ANGLE VOIDS BETWEEN WALL AND SEE NOTE DAMPER SLEEVE SHALL BE TRANSITION LEFT OPEN SO AS NOT TO INTERFERE WITH EXPANSION. DAMPERS SHALL BE 11/2 HOUR RATED UNDER IIR x 11/¢ x 1/9 114 TO /¢ EXPANSION! U.L. STANDARD 555 AND QUALIFIED UNDER RETAINING ANGLE ACCESS DOOR IN DUCT. CLEARANCE. SEE NOTE U.L. 555 S AS A TYPE 2 LEAKAGE RATED SEE NOTE REFER TO SPECIFICATIONS SMOKE DAMPER. SEE SPECIFICATIONS SECTION FOR DOOR TYPE AND SIZE i FOR MODEL NUMBERS. NOTES: NOTES: 1. PROVIDE U.L. LISTED DAMPER, SLEEVE & OPERATOR ASSEMBLY IN ACCORDANCE WITH U.L. 555 AS A SINGLE ENTITY. I. PROVIDE U.L. LISTED DAMPER AND SLEEVE IN ACCORDANCE WITH U.L. 555 AS A 2. INSTALL DAMPER AND SLEEVE IN ACCORDANCE WITH MANUFACTURER'S SINGLE ENTITY. INSTRUCTIONS NOT TO VOID U.L. LISTING. 2. INSTALL DAMPER AND SLEEVE IN ACCORDANCE WITH MANUFACTURER'S 3. EXTEND SLEEVE BEYOND WALL A MAX. 6 INCHES AND MOUNT OPERATOR ON INSTRUCTIONS NOT TO VOID U.L. LISTING. SLEEVE. 3. EXTEND SLEEVE BEYOND WALL MAX. 6 INCHES. 4. PROVIDE EXPANSION SPACE PER MANUFACTURER'S INSTRUCTION, BUT NOT LESS 4. PROVIDE EXPANSION SPACE PER MANUFACTURER'S INSTRUCTION, BUT NOT LESS THAN 1/d PER LINEAR FOOT. THAN I/d PER LINEAR FOOT, BOTH DIRECTIONS. 5. PROVIDE MINIMUM 1f¢ x III 1/¢ RETAINING ANGLE ON TOP. BOTTOM &SIDES. 5. PROVIDE MINIMUM 11/¢ x 11/¢ x I/d RETAINING ANGLE ON TOP, BOTTOM, AND SIDES. ATTACH ANGLES To SLEEVE IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. ATTACH ANGLE TO SLEEVE IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. DAMPER SHALL BE SELF SUPPORTING, INDEPENDENT OF DUCTWORK, ANGLES SHALL DAMPER SHALL BE SELF SUPPORTING, INDEPENDENT OF DUCTWORK. ANGLES SHALL OVERLAP WALL A MINIMUM OF ONE INCH. OVERLAP WALL A MINIMUM OF ONE INCH. 6. INSTALL A MINIMUM OF 5 FEET OF SHEETMETAL DUCTWORK ON BOTH SIDES 6. INSTALL A MINIMUM OF 5 FEET OF SHEETMETAL DUCTWORK ON BOTH SIDES OF THE RATED WALL PRIOR TO ANY DUCTWORK TRANSITIONS. OF THE RATED WALL PRIOR TO ANY DUCTWORK TRANSITIONS. COMBINATION FIRE /SMOKE FIRE DAMPER AT RATED WALL DAMPER AT RATED WALL EXISTING HVAC WATER PIPING - CONNECT TO EXISTING SYMBOL LINE SIZE SHUTOFF VALVES EW MAINS TO TEMPORARY FLUSHING LOOP, CONNECTION ONE SIZE EW EQUIPMENT SMALLER THAN LINE SIZE. REMOVE AND CAP WHEN SYSTEM IS PROVEN CLEAN FROM FLUSHING. HOSE END DRAIN VALVE SCHEDULE PIPE SIZE DRAIN VALVE SIZE UP TO 2' 314 21/¢ TO 4' 11/4 5' TO 8' 2' OVER 8' 21/¢ NEW HVAC WATER PIPE CONNECTIONS TO EXISTING PIPING SPLIT RING TYPE CLEVIS TYPE HANGER PIPE HANGER (SEE SPECS) SEE SPEC'S 1NGER SULA1 PIPE .,HEFT METAL SADDLE PIPE HANGER SUPPORTS SUCKLE QUIRED) PRINTED 24 "X36" NOT TO SCALE �^ o) .-A CO �1 m 0 U" M . M U_ LL 0 to a 0 � w 0 _ U5 Uco o J Q m a U 2 W 2 0 U 3 0 C14 Z .� o Q o g o z o w Smith SSIAL Beckman Reid, Inc. 600 West Hillsboro, Suite 300 Deerfield Beach, FL 33441 (954) 421 -1260 FAX; (954) 421 -1466 www.ssr- inc.com Firm CerUr=uon - EB-0000857 J.h.LM.ld. PE•55P06 Micb.dA Sbu—d PE •65701 SSR JOB # 1132063.0 cc 0 U Z J Q U W C M 00 q M 0 J LL LL C,0 w 1 Q ~ J W 0 F- H 5 � O V CO (n Q H = w Z J W o W��0 3:5 M H z 0 0 CL M O Q0 0 0 m o Comm. No: 11087.00 Date: 01/18/12 Drawn: Revised: No. 332 F �I ., •,,O R � �.P: rte`. ARbJNC. M3.1