Loading...
12-354-0564100 -8201 Fire Alarm Control Panel - Node 6 - South Miami Hospital - 4TH Floor Main Tower Standby Total Alarm Total Module Oty Description Current Standby Current Alarm Panel Equipment 4100 -8201 1 CONTROL PANEL W AUDIO 0.000000 0.000000 0.000000 0.000000 4100 -7003 1 MASTER CONTROLLER 0.292000 0.292000 0.292000 0.292000 4100 -6051 1 NON -POWER LIMITED OPTION 0.000000 0.000000 0.000000 0.000000 4100 -4321 9 6 CIRCUIT CLASS B STYLE 0.025000 0.225000 0.070000 0.630000 4100 -3003 1 8 PT AUX RELAY MOD 3 AMP 0.025000 0.025000 0.280000 0.280000 4100 -0108 2 EXPANSION 120V 8AMP POWER SUPP 0.000000 0.000000 0.000000 0.000000 4100 -0110 2 MAPNET II ADDRESSABLE MODULE 0.270000 0.540000 0.290000 0.580000 4100 -0210 1 SINGLE CHANNEL AUDIO CONTROL 0.185000 0.185000 0.185000 0.185000 4100 -0203 1 100 WATT AMPLIFIER 0.068000 0.068000 8.750000 8.750000 4100 -0215 1 PHONE RISER TERMINATION BOARD 0.000000 0.000000 0.000000 0.000000 4100 -0301 1 64/64 LED SWITCH CONTROLLER 0.015000 0.015000 0.260000 0.260000 4100 -0412 1 1 CHANNEL AUDIO CONTROL SWITCH 0.000000 0.000000 0.000000 0.000000 4100 -2003 2 PKG SIZE, 6 UNIT, GLASS DR 0.000000 0.000000 0.000000 0.000000 4100 -0142 2 WIRED MEDIA MODULE 0.040000 0.080000 0.040000 0.080000 4100 -6014 1 NETWORK IF CARD, WIRED 0.046000 0.046000 0.046000 0.046000 0 Total Panel Sthy 1.476000 Total Panel Alarm 11.103000 Peripheral Devices 4099 -9001 27 IDNET SINGLE ACTION PULL STATION ' 0.000000 0.000000 0.000000 0.000000 4098 -9733 12 TRUEALERM HEAT SENSOR 0.000000 0.000000 0.000000 0.000000 4098 -9714 143 TRUEALERM PHOTO SMOKE SENSOR 0.000000 0.000000 0.000000 0.000000 4098 -9792 150 TRUEAIARM SENSOR BASE ' 0.000000 0.000000 0.000000 0.000000 4098 -9756 12 TRUEALERM DUCT SMOKE SENSOR W RELAY OUTPUT '2 0.002400 0.028800 0.015000 0.180000 2098 -9797 12 SAMPLING TUBE 49' 0.000000 0.000000 0.000000 0.000000 2098 -9806 12 REMOTE TEST STATION W LED AND KEY SWITCH 0.000000 0.000000 0.000000 0.000000 4098 -9843 12 ENCAPSULATED RELAY PAM -SD 0.002400 0.028800 0.015000 0.180000 4090 -9001 15 IDNET SUPERVISED LAM ' 0.000000 0.000000 0.000000 0.000000 2190 -9161 5 MAPNEr CLASS B SIGNAL ZAM ' 0.015000 0.075000 0.040000 0.200000 2190 -9163 0 MAPNEr UNSUPERVISED CONTROL ZAM ' 0.010000 0.000000 0.040000 0.000000 4903 -9150 69 15CD SPEAKER /VISIBLE RED HORIZONTAL MOUNT 25 OR 70VRMS 0.000000 0.000000 0.082000 5.658000 4903 -9148 4 30CD SPEAKER /VISIBLE RED HORIZONTAL MOUNT 25 OR 70VRMS 0.000000 0.000000 0.123000 0.492000 4903 -9149 1 110CD SPEAKER /VISIBLE RED HORIZONTAL MOUNT 25 OR 7GVRMS 0.000000 0.000000 0.275000 0.275000 4904 -9176 28 15CD VISIBLE ONLY F S RED VERTICAL MOUNT 0.000000 0.000000 0.082000 2.296000 4903 -9357 0 TRUEALERT 75CD SPEAKER /VISIBLE 25V 70VRMS RED 0.000000 0.000000 0.199000 0.000000 4904 -9332 0 TRUEALERT 75CD VISIBLE ONLY RED SYNC 0.000000 0.000000 0.199000 0.000000 ET7OWP- 2475W -FR 6 WHEELOCK WALL MOUNT SPEAKER STROBE 75CD WP 0.000000 0.000000 0.102000 0.612000 4905 -9938 11 TRUEALERT SYNC CONTROL MODULE 0.000000 0.000000 0.030000 0.330000 DSM -12 24-R 1 1WHEELOCK DUAL SYNC MODULE 0.000000 0.000000 0.038000 0.038000 4902 -9721 0 SPEAKER 25V/70VRMS WHITE CEILING 0.000000 0.000000 0.000000 0.000000 4904 -9174 0 30CD VISIBLE ONLY F S RED VERTICAL MOUNT 0.000000 0.000000 0.123000 0.000000 4904 -9175 0 110CD VISIBLE ONLY F S RED VERTICAL MOUNT 0.000000 0.000000 0.275000 0.000000 2084 -9001 23 REMOTE PHONE JACK 0.000000 0.000000 0.000000 0.000000 4906 -9101 7 TRUE ALERT MULTICANDELA STROBE, 75CD, WALL 0.000000 0.000000 0.186000 1.302000 4906 -9151 12 ITRUE ALERT MULTICANDELA SPEAKER STROBE, 75CD, WALL 0.000000 0.000000 0.186000 2.232000 0 Total Peri h Stbyl 0.133 Total Peri h Alarm 13.795 Total Standby Ampsj 1.609 Total Alarm Amps 24.898 ' Current Draw Included With Device Addresses Used (See additional current draws) Quantity Of Back -up Amplifiers 0 1. 2 -wire detector alarm current is included in the alarm current of the Initiating Device Circuit. 2. 50% of these devices in alarm, are used in the calculations below Standby Alarm Battery Set 1 (Cabinet/Charger 1 Qty Current Current Control Panel Power Master Power Supply 0.868 1.773 Mapnet /IDNet Card Current Draw 2 0.540 0.580 Current Draw For 90 Watt Or 100 Watt Amplifiers 1 0.058 8.750 Current Draw For Dual 25 Watt Amplifiers 0 0.000 0.000 Power For External Peripheral Devices 0.13260 13.72300 1.609 < -- Sub Totals - -> 24.826 Additional Current Draws MAPNET /IDNet Device Addresses ordered / used 209 209.0 0.172 0.213 Spare addressable point capacity included for battery cole 20% 42 0.034 0.043 1.815 <- -Grand Totals - -> 25.081 Additional Battery Capacity Required 20% 0.363 5.016 Standby Time = 4 Hrs 8.710 Standby Ah Alarm Time = 15 Mins. _ 7.524 Alarm Ah Battery Supplied 2081 -9296 50AH 37.343 Total Ah 4100 -8201 Fire Alarm Control Panel - Node 6 - South Miami Hospital - 4TH Floor Main Tower SPEAKER CIRCUIT LOAD CALCULATION MAXIMUM -3 dB DROP PER CIRCUIT PHONE /SPEAKER CIRCUIT DESCRIPTION PANEL CIRCUIT NUMBER WIRE GAUGE (18, 16, 14 12 ) CIRCUIT VOLTAGE (25 OR 70 VRMS ) APPLIANCES 4902 -9721 4903 -9150 4903 -9148 TAPPED AT TAPPED AT TAPPED AT 0.25 Watts 0.5 Watts 0.5 Watts QUANTITIES TAP VALUES 4903 -9149 ET70WP- 2475W -FR 4906 -9151 2084 -9001 TAPPED AT TAPPED AT TAPPED AT PHONE JACK 0.5 Watts 1 Watts 0.5 Watts 0 Watts TOTAL CIRCUIT LOAD WATTS ESTIMATED CIRCUIT LENGTH FE ACTUAL WIREAOSS dB MAXIMUM ALLOWABLE CKT. LENGTH FE TOTAL CIRCUIT RESISTANCE OHMS Amplifier Power supply 4TH FLOOR BRIDGE TO EAST TOWER SPEAKERS 6:Si -15 18 owg 25 vrms 0 7 0 0 0 0 0 3.50 Watts 200 ft. -0.12 dB 5,782 ft. 2.6 Ohms AMPOI 4TH FLOOR MAIN BUILDING SPEAKERS 6:Si -16 18 awo 25 vrms 0 8 0 0 0 0 0 4.00 Watts 200 ft. -0.14 dB 5,059 ft. 2.6 Ohms AMPOt 4TH FLOOR MAIN BUILDING SPEAKERS 6:Si -17 18 awg 25 vrms 1 0 10 0 0 0 0 0 5.00 Watts 200 ft. -0.18 dB 4,047 ft. 2.6 Ohms AMPOI 5TH FLOOR MAIN BULDING SPEAKERS 6:Si -18 18 awg 25 vrms 0 6 2 0 0 0 0 4.00 Watts 225 ft. -0.16 dB 5,059 ft. 2.9 Ohms AMPOI 5TH FLOOR MAIN BUILDING SPEAKERS 6:Si -19 18 awg 25 vrms 0 8 0 0 0 0 0 4.00 Watts 225 ft. -0.16 dB 5,059 ft. 2.9 Ohms AMP01 6TH FLOOR MAIN BULDING SPEAKERS 6:Si -20 18 awg 25 vrms 0 0 0 0 0 11 0 5.50 Watts 250 ft. -0.24 dB 3,679 ft. 3.2 Ohms AMP01 SPARE 6:Si -21 18 awg 25 vrms 0 0 0 0 0 0 0 0.00 Watts 250 ft. 0.00 dB 0 ft. 3.2 Ohms AMPOt 7TH FLOOR MAIN BULDING SPEAKERS 6:Si -22 18 awg 25 vrms 0 5 2 0 0 1 0 4.00 Watts 275 ft -0.19 dB 5,059 ft. 3.5 Ohms AMP01 7TH FLOOR MAIN BOLDING SPEAKERS 6:Si -23 18 owg 25 vrms 0 7 0 0 0 0 0 3.50 Watts 275 ft. -0.17 dB 5,782 ft. 3.5 Ohms AMP01 7TH FLOOR MAIN BULDING SPEAKERS 6:Si -24 18 awg 25 vrms 0 5 0 1 0 0 0 3.00 Watts 275 ft. -0.15 dB 6,745 ft. 3.5 Ohms AMP01 8TH FLOOR MAIN BUILDING SPEAKERS 6:Si -25 18 Owg 25 vans 0 1 0 0 0 0 0 0.50 Watts 300 ft. -0.03 dB 40,471 ft. 3.8 Ohms AMPOI 9TH FLOOR MAIN BULDING SPEAKERS 6:Si -26 18 Owg 25 vrms 0 0 0 0 0 0 0 0.00 Watts 0 ft. 0.00 dB 0 ft. 0.0 Ohms AMPOI ELEVETOR CAB J9 SPEAKERS 6:Si -27 18 awg 25 vrms 1 0 0 0 6 0 0 6.25 Watts 300 ft. -0.33 dB 3,238 ft. 3.8 Ohms AMPOI ELEVETOR CAB 110 SPEAKERS 6:Si -28 18 awQ 1 25 vrms 1 0 0 0 0 0 0 0.25 Watts 300 ft. -0.01 dB 80,943 ft. 3.8 Ohms AMPOI SPARE 6:Si -29 18 awg 25 vrms 0 0 0 0 0 0 0 0.00 Watts 200 ft. 0.00 dB 0 ft. 2.6 Ohms AMPOI SPARE 6:Si -30 18 awg 25 vrms 0 0 0 0 0 0 0 0.00 Watts 200 ft. 0.00 dB 0 ft. 2.6 Ohms AMP01 SPARE 6:Si -31 18 awg 25 vrms 0 0 0 0 0 0 0 0.00 Watts 200 ft. 0.00 dB 0 ft. 2.6 Ohms AMP01 SPARE 6:Si -32 18 awg 25 vrms 0 0 0 0 0 0 0 0.00 Watts 200 ft. 0.00 dB 0 ft. 2.6 Ohms AMP01 4TH FLOOR MAIN BULDING PHONES 6:Si -33 18 awg N A vrms 0 0 0 0 0 0 1 0.00 Watts 200 ft. 0.00 dB 0 ft. 2.6 Ohms N A 5th FLOOR MAIN BULDING PHONES 6:Si -34 18 awg N A vrms 0 0 0 0 0 0 3 0.00 Watts 225 ft. 0.00 dB 0 ft 2.9 Ohms N A 6th FLOOR MAIN BULDING PHONES 6:Si -35 18 Owg N A vans 0 0 0 0 0 0 3 0.00 Watts 250 ft. 0.00 dB 0 ft. 3.2 Ohms N A 7th FLOOR MAIN BULDING PHONES 6:Si -36 18 awg N A vrms 0 0 0 0 0 0 3 0.00 Watts 0 ft. 0.00 dB 0 ft. 0.0 Ohms N/A 8th FLOOR MAIN BULDING PHONES ROOF 6:Si -37 18 awg N A vrms 0 0 0 0 0 0 2 0.00 Watts 0 ft. 0.00 dB 0 ft. 0.0 Ohms N A 9th FLOOR MAIN BULDING PHONES ELEV MACH ROOM 6:Si -38 18 aw N/A vrms 0 0 0 0 0 0 1 0.00 Watts 0 ft. 0.00 dB 0 ft. 0.0 Ohms N/A ELEVETOR CAB J9 PHONES 6:Si -39 18 Owg N A vrms 0 0 0 0 0 0 1 0.00 Watts 300 ft. 0.00 dB 0 ft. 3.8 Ohms N/A ELEVETOR CAB 110 PHONES 6:Si -40 18 cwg N A vrms 0 0 0 0 0 0 1 0.00 Watts 300 ft. 0.00 dB 0 ft. 3.8 Ohms N/A 4TH FLOR STAIR 17 6:Si -41 18 aw N/A vans 0 0 0 0 0 0 1 0.00 Watts 100 ft. 0.00 dB 0 ft. 1.3 Ohms N/A 4th FLOR STAIR f6 6:Si -42 18 aw N/A vans 0 0 0 0 0 0 1 0.00 Watts 100 ft. 0.00 dB 0 ft. 1.3 Ohms N/A 5TH FLOR STAIR #6 6:Si -43 18 Owg NA vrms 0 0 0 0 0 0 1 0.00 Watts 125 ft. 0.00 dB 0 ft. 1.6 Ohms N/A 5th FLOR STAIR 7 6:Si -44 18 aw N/A vrms 0 0 0 0 0 0 1 0.00 Watts 125 ft. 0.00 dB 0 ft. 1.6 Ohms N A 6TH FLOR STAIR 6 &Si -45 18 aw N A vans 0 0 0 0 0 0 1 0.00 Watts 150 ft. 0.00 dB 0 ft 1.9 Ohms N A 6th FLOR STAIR 7 6:Si -46 18 aw _N/A vrms 0 0 0 0 0 0 1 0.00 Watts 150 ft 0.00 dB 0 ft 1.9 Ohms N A 7TH FLOR STAIR 6 6:Si -47 18 aw N A vrms 0 0 0 0 0 0 1 0.00 Watts 175 ft. 0.00 dB 0 ft 2.2 Ohms N A 7th FLOR STAIR 7 6:Si -48 18 awg N A vrms 0 0 1 0 0 0 1 0 1 0.00 Watts 175 ft 0.00 dB 0 ft 2.2 Ohms N/A 8th FLOR STAIR 17 6:Si -49 18 aw N/A vrms 0 0 1 0 0 0 1 0 0 0.00 Watts 0 ft 0.00 dB 0 ft 0.0 Ohms N A SPARE 6:Si -50 18 aw A _N TA 0 0 0 0 0 0 0 0.00 Watts 0 ft. 0.00 dB 0 ft 0.0 Ohms N A Appliance Summary Total Load (Watts) Max Load (Watts) Per Amp 2 1 57 1 4 1 1 1 6 1 12 1 23 1 43.50 100.00 Max Load Watts Per Circuit 45.00 NOTE: LUMP SUM METHOD WAS USED TO CALCULATE MAXIMUM ALLOWABLE CIRCUIT LENGTH. THIS METHOD ALLOWS FOR A SMALL MARGIN OF SAFETY, TAKING INTO CONSIDERATION THE ACTUAL INSTALLED CIRCUIT ROUTING MAY DIFFER FROM WHAT IS SHOWN ON THE SHOP DRAWINGS. IF THE ACTUAL CIRCUIT LENGTH IS GOING TO EXCEED THE MAXIMUM ALLOWABLE CIRCUIT LENGTH, CONTACT YOU LOCAL SIMPLEX BRANCH. 4100 -8201 Fire Alarm Control Panel - Node 6 - South Miami Hospital - 4TH Floor Main Tower NAC SCHEDULE VOLTAGE DROP CALCULATION VOLTAGE DROP TOTALS 17 % MAXIMUM VOLTAGE DROP ESTIMATED 4903 -9150 4903 -9148 4903 -9149 4904 -9176 ET7OWP- 2475W -FR 1 4905 -9938 1 DSM- 12/24 -R 1 4906 -9151 1 TOTAL WIRE ACTUAL ACTUAL CIRCUIT OUTPUT VOLTAGE - 20.4 FOR CALCULATIONS CIRCUIT CIRCUIT 15cd Spkr /Strb 30cd Spkr /Strb 110ed Spkr /Strb 15ed Strobe 75cd WP Sync Module SYNC MODULE S/S 75CD CKT. LOAD GAUGE VOLTAGE VOLTAGE CIRCUIT I DESCRIPTION TYPE LENGTH 0.082000 0.123000 0.275000 0.082000 0.102 0.030000 0.038 0.186 (AMPS) (18. 16. 14. 12) DROP X DROP (VOL Rvisual 1 250 ft. 6:SIG -11 7 FL MAIN BUILDING I Rvisual 275 ft. 6:SIG -12 7 FL MAIN BUILDING Rvisual 275 ft. 6:SIG -13 7 FL MAIN BUILDING Rvisual 275 ft. 6:SIG -14 8 FL MAIN BUILDING ROOF Rvisual 300 ft. 6:SIG -51 9 FL MAIN BUILDING ELEV MACH ROOM Rvisual 300 ft. 6:SIG -52 4 FL MAIN BUILDING Rvisual 200 ft. 6:SIG -53 SPARE STROBE Rvisual 0 ft. &SIG -54 SPARE STROBE Rvisual 0 ft. 6:SIG -55 STROBE SYNC Rvisual 20 ft. 6:SIG -56 STROBE SYNC Rvisual 20 ft. METHOD USED TO CALCULATE PERCENT OF VOLTAGE DROP: 0 0 [(CIRCUIT LENGTH IN FEET X 2) (AMPS X OHMS /FOOT)] X 100 0 0 20.4 VOLTS 0 0.000 Wire Resistance At 0 0 75 Degrees Celsius 0 0 Ohm /1000 ft 0 0 12GA = 1.93 Appliance Summary 14GA = 3.07 57 4 1 23 1 6 9 1 1 16GA = 4.89 Z 18GA = 7.77 U) WIRE RESISTANCE BASED ON TABLE 8 FROM NATIONAL ELECTRICAL CODE (UNCOATED SOLID COPPER WIRE) NOTE, a J LUMP SUM METHOD WAS USED TO CALCULATE ALLOWABLE VOLTAGE DROP. THIS METHOD ALLOWS FOR A SMALL MARGIN OF SAFETY, TAKING INTO CONSIDERATION THE ACTUAL INSTALLED CIRCUIT ROUTING MAY DIFFER FROM WHAT IS SHOWN ON THE SHOP DRAWINGS. IF THE ACTUAL CIRCUIT LENGTH IS GOING TO EXCEED THE MAXIMUM ALLOWABLE CIRCUIT LENGTH, CONTACT YOUR LOCAL SIMPLEX BRANCH. 1 0 0 0 0 0 0 0 0.082 0.9 Ohms 0 0 0 11 0 0 0 0 0.902 0 ft. 0 0 0 0 0 0 0 0 0.000 PSOt -B 0 0 0 0 0 0 0 0 0.000 W04 0 0 0 0 0 0 0 0 0.000 0 0 0 0 0 0 0 0 0.000 Appliance Summary Total Load 8.395 57 4 1 23 1 6 9 1 1 1 \SCYAAII \DRAFfING\00- 20a3\SOUIH M6M HOSPIUL (4ASTER SRQ \SAM ELEVATOR ROMATION 057046316 REVa2 \SMH ELEVATOR REIMATEN 95MM13DffiATED: Farmy 22. 2012 DATE PID=: March 22, 2012 DATE SAVED: March 22, 2012 1 0.00% Max Load Q 24.000 0.846 0.709 0.095 0.696 0.000 0.000 SUPPLY I CKT. LIENGTH 0.8 Ohms 1,501 ft PSM -B 0.8 Ohms 1,181 ft PSM -B 0.8 Ohms 1,067 ft PSM -B 0.9 Ohms 1,181 ft. PSM -8 0.9 Ohms 1,322 ft. PS01 -A 0.9 Ohms 1,181 ft PSOI -A 0.0 Ohms 0 ft. PS01 -A 0.0 Ohms 0 ft. PS01 -A 1.1 Ohms 950 ft PSOt -B 1.1 Ohms 1,501 ft PSOt -B 1.1 Ohms 1.138 ft. PSOi -B Max Load (AMPS) Per Circuit Note: Each Power Supply is 8 Am s divided into two 4 Amp tops. PSM -A System Power Amps PSM -B 2.990 Amps PS01 -A 1.454 Am PS01 -B 2.967 Am PS02 -A 0.984 Am Hs 0.000 Am MAIN BUILDING BATTERY CALCULATIONS INSTALLED INM CoRDANCEBWMi NFPA 72; 7a;101- MIAlyi[ -DADE COUNTY FIRE DEPARTMENT BLDG. PERMIT FIRE ALARM FIRE SUPPRESSION WATER 1"N EXT. DATE: A >/Z- BY 1- W L Q 0 z z W w CO� UA CO li CO a �C) Q "' W04 W z n- Co Q of M M (D W,.; to co U) 0) LLchM 0��� z W U) O O i.r Z CO U) 9 a J J w z � Z_w �w 1` (L 3: o< t7 z Y x a x z N o a~ zo z w U) 0 L:) z O p C0 O Q U w_ w o w w o 0: w x m x V U U U U w N O L0 G) c) � z N U 2 Cd S 0W Ld aW Z o G a 6 ea K 2 o o � � ►-i J < W A oa< W o F_ JU O ILWK � 0 0 o W _j FN= U .n� w ►--� ry ui E� 1 (� CO Z z °a w rM3 < z a _ ILL Y o w WWu W LL p N J J ch Z .. O g z z It W y J o z o i - 102 CO J a z E o U E- z z U w U �j m LL W 0: Iii (X = < z g F- LLI OLL Z U ao a� o ca J OU)a =) < M 07 ox a ILL! 0 U Z FF- o O 0 F_ g Z F_ S E.. o 0 z >� 0 a w_ Z - J °W OZ z� Z W U Z_ Z ? w 0 J LL �o z �Q ¢V) Of O Z 0' 0 E-+ C\2 ".2 w z o <4 W U) _j a. CO M = C') rn O E[�. UI-r1O z Z�o za o Qoa 20 z CY) P-0 o¢d o 30 DRAWN BY: DATE: CCRJR 5/26/11 DESIGNED BY: DATE: CCRJR 5/26/11 APPROVED BY: DATE: PROJECT NUMBER: 263 - 409382 / 957182917 - 957048316 SHEET TITLE/ PATH: \ \Sgmiamil \D RAFTI NG \00- 2003 \SOUTH MIAMI HOSPITAL (MASTER SITE) \SMH Elevator Renovation 957048316 REVO1 SHEET NUMBER: BATTERY-4 SIZE D (24738')