12-354-012
MAIN BUILDING'S SYMBOL LEGEND SYMBOL SIMPLEX MODEL # DESCRIPTION SYMBOL SIMPLEX MODEL # DESCRIPTION NODE 6 4100 -8201 NETWORK FIRE ALARM PANEL WITH VOICE & PHONES EXISTING IN 4TH FLOOR ELECTRIC ROOM TC74 FIRE WATCH XVI FIRE ALARM TERMINAL CABINET FURNISHED BY ELECTRICAL CONTRACTOR Z1 4090 -9001 INDIVIDUAL ADDRESS MODULE CONNECT TO N/O CONTACTS ONLY El 4099 -9001 2099 -9813 PULL STATION ADDRESSABLE PULL STATION FLUSH TRIM O 4098 -9792 4098 -9733 SSD SENSOR BASE SSD HEAT SENSOR SD 4098 -9792 4098 -9714 SSD SENSOR BASE SSD PHOTO SENSOR SD 4098 -9756 2098 -9797 SSD DUCTSENSOR HOUSING SAMPLING TUBE 49" 0 2098 -9806 REMOTE TEST STATION RED LED KEY SWITCH FS 10565 FLOW DETECTOR SWITCH FURNISHED BY DIVISION 15 TS 10560 TAMPER (GATE VALVE) SWITCH FURNISHED BY DIVISION 15 �Mr 9187 END OF LINE RESISTOR [� 4905 -9938 SMARTSYNC CONTROL MODULE 75cd �MC 4906 -9151 SPEAKER/STROBE MC, RED, WALL 75cd �L MC 4906 -9101 STROBE MC, RED, WALL. 150d I s K 4903 -9150 SPEAKER/STROBE 15CD, RED, WALL. 30cd I ° j 4903 -9148 SPEAKER/STROBE 30CD, RED, WALL. 110cd 4903 -9149 SPEAKER/STROBE 11OCD, RED, WALL. 15cd �L 4904 -9176 STROBE 15CD, RED, WALL. FJ 2084 -9001 FIREMAN'S PHONE JACK ❑R 4098 -98.43 RELAY, SPDT AT 10 AMP, PAM-SD 1 2084 -9001 CONNECTION TO AN APPROVED, DEDICATED EWS EL -1-SS EARTHGROUND, NFPA 70. COMPLY WITH NEC. L 2088 -9608 CONNECTION TO AN APPROVED, DEDICATED EARTHGROUND, NFPA 70. COMPLY WITH NEC. _Vot 3014B 120VAC SOURCE DEDICATED BREAKER COMPLY WITH NFPA 70. E EXISTING N NEW R RELOCATED W 4906 -9151 WATTS SOUTH PARKING'S SYMBOL LEGEND DEVICES SYMBOL SIMPLEX MODEL # DESCRIPTION FACP 4100 -9111 NETWORK FIRE ALARM PANEL WITH VOICE & PHONES EXISTING 4009 -9201 NAC EXTENDER, 120VAC. IDNET. FACP FIRE WATCH XVI EXISTING FARADAY FIRE ALARM CONTROL PANEL FARADAY 4099 -9001 2099 -9813 PULL STATION ADDRESSABLE PULL STATION FLUSH TRIM 120VAC 4098 -9792 4098 -9714 SSD SENSOR BASE SSD PHOTO SENSOR � THIS ,SYSTEM SHALL BE A CERTIFICATED OF I C PS SERIES EXISTING WHEELOCK NAC POWER SUPPLY C D 7700 SERIES EXISTING FARADAY REMOTE ANNUNCIATOR 1 VP 10560 EXISTING FARADAY PULL STATION O_ 10565 EXISTING FARADAY WEATHERPROOF PULL STATION BACK BOX Q 10560 EXISTING FARADAY PULL STATION SD 9187 EXISTING FARADAY SENSOR DETECTOR [� 9447 EXISTING FARADAY HEAT DETECTOR OO CF 135 -2 MP HIGH HUMIDITY 2 N/O 135 DEG FIX HEAT DETECTOR wp ADD ONE PULL STATION & ONE STROBE TO ELEVATOR OPERATION IN 75CD 4904 -9169 NEW SIMPLEX STROBE 0.095 AMPS 75CD 6235 EXISTING FARADAY HORN /STROBE 0.095 AMPS 75CD 6235 EXISTING FARADAY HORN /STROBE 0.095 AMPS VP 3014B EXISTING FARADAY WEATHERPROOF BACK BOX -m 4902 -9703 END OF LINE RESISTOR 75CD © PAM -SD RELAY 7.0 AMPS FORM "C" CONTACTS 1 2084 -9001 CONNECTION TO AN APPROVED, DEDICATED EWS EL -1-SS EARTHGROUND, NFPA 70. COMPLY WITH NEC. 1mr� 2088 -9608 120VAC SOURCE DEDICATED BREAKER = 3014B COMPLY WITH NFPA 70. J -1 120VAC SOURCE DEDICATED BREAKER COMPLY WITH NFPA 70. EXISTING MOTOR CONTROL CENTER BY OTHERS ELEVATOR ELEVATOR CONTROLLER CONTROLLER 4906 -9151 FURNISHED BY OTHERS 120VAC 4906-9101 V/O MULTI - CANDELA 75CD„ NON- ADDRESSABL, RED, WALL. 9 ' E EXISTING R RELOCATED \ \SG"l \DP I*&N00- 2003\WM MM HOSPITAL 00SU SrM \SMH ElMMR WMATM 957046716 RMI \SMH WATOR RENO TM 057DRIMM ATM Sep w6w 15, 2011 DATE PLOMD Sptanbw 2z, 2011 DATE 800. Se$urkw 2Z 2011 PAVILION BUILDING'S SYMBOL LEGEND DEVICES SYMBOL SIMPLEX MODEL # DESCRIPTION FACP 4100 -9111 NETWORK FIRE ALARM PANEL WITH VOICE & PHONES ® 4009 -9201 NAC EXTENDER, 120VAC. IDNET. FATC FIRE WATCH XVI FIRE ALARM TERMINAL CABINET FURNISHED BY ELECTRICAL CONTRACTOR SIGNALING LINE CIRCUIT WIRING SHALL BE 4099 -9001 2099 -9813 PULL STATION ADDRESSABLE PULL STATION FLUSH TRIM SD 4098 -9792 4098 -9714 SSD SENSOR BASE SSD PHOTO SENSOR 4, THIS ,SYSTEM SHALL BE A CERTIFICATED OF PLACARDED CENTRAL STATION SERVICE PER Z1 4090 -9001 INDIVIDUAL ADDRESS MODULE CONNECT TO N/O CONTACTS ONLY E VP 2190 -9161 NOTIFICATION APPLIANCE ZAM OH CC-623 ........................................... ELEVATOR SHUNT TRIP OPERATION O_ 4098 -9792 4098 -9733 SSD SENSOR BASE SSD HEAT SENSOR SD 4098 -9756 2098 -9797 SSD DUCTSENSOR HOUSING SAMPLING TUBE 49" OR 2098 -9806 REMOTE TEST STATION RED LED KEY SWITCH ® 4098 -9843 RELAY FORM C SPDT PAM -SD ® 2088 -9032 RELAY SPDT WILED MR -801 /T FS ADD ONE PULL STATION & ONE STROBE TO FLOW DETECTOR SWITCH FURNISHED BY DIVISION 15 TS 10, TAMPER (GATE VALVE) SWITCH FURNISHED BY DIVISION 15 ONE TAMPER SWITCH IN ;TAIR 6. .. END OF LINE RESISTOR ©M 4905 -9938 SMARTSYNC CONTROL MODULE 75CD L� IV 4903 -9357 SPEAKER/STROBE756D SYNC WALL MOUNT �S 4902 -9703 SPEAKER WALL MOUNT 75CD © 4904 -9333 STROBE 75CD SYNC WALL MOUNT F F 2084 -9001 FIREMAN'S PHONE JACK EWS EL -1-SS ELEVATOR WARNING SIGN ® 2088 -9608 DOOR HOLDER = 3014B CONNECTION TO AN APPROVED, DEDICATED EARTHGROUND, NFPA 70. COMPLY WITH NEC. J -1 120VAC SOURCE DEDICATED BREAKER COMPLY WITH NFPA 70. ® MOTOR CONTROL CENTER BY OTHERS Piv PIV (GATE VALVE) SWITCH FURNISHED BY DIVISION 15 75CD MC 4906 -9151 SN MULTI- CANDELA 25170V NON- ADDRE, RED, TALL. 75CD © MC 4906-9101 V/O MULTI - CANDELA 75CD„ NON- ADDRESSABL, RED, WALL. N NEW E EXISTING R RELOCATED W WATTS PAVILION & MAIN BUILDING'S SEQUENCE OF OPERATION: (FLOOR OF INCIDENT. FLOOR ABOVE & FLOOR BELOW) UPON ACTIVATION OF ANY MANUAL STATION THE FOLLOWING SHALL OCCUR: 1. ALL AUDIBLES WILL SOUND UNTIL SYSTEM IS SILENCED. 2. ALL STROBES WILL FLASH UNTIL SYSTEM IS RESET. 3. AN ALARM SIGNAL SHALL BE SENT TO THE FACP & NPU'S. 4. A SIGNAL SHALL BE SENT TO THE OWNERS MONITORING STATION STATION VIA DACT UPON ACTIVATION OF ANY SMOKE DETECTOR THE FOLLOWING SHALL OCCUR: 1. ALL AUDIBLES WILL SOUND UNTIL SYSTEM IS SILENCED. 2. ALL STROBES WILL FLASH UNTIL SYSTEM IS RESET. 3. ALL AIR HANDLERS SHALL SHUT DOWN.PER THE DESIGNATED SEQUENCE. 4. AN ALARM SIGNAL SHALL BE SENT TO THE FACP & NPU'S. 5. A SIGNAL SHALL BE SENT TO THE OWNERS CENTRAL STATION VIA DACT. 6. MAGNETIC DOOR HOLDERS SHALL RELEASE ON THE FLOOR OF INCIDENT ONLY. 7. ALL FIRE SMOKE DAMPER SHALL ACTIVATE. UPON ACTIVATION OF THE ELEVATOR LOBBY SMOKE DETECTORS (WITH THE EXCEPTION OF THE ELEVATOR LOBBY DETECTOR AT THE PRIMARY LEVEL OF EGRESS), THE FOLLOWING SHALL OCCUR: 1. ALL AUDIBLES WILL SOUND UNTIL SYSTEM IS SILENCED. 2. ALL STROBES WILLFLASH UNTIL SYSTEM IS RESET. 3. ALL AIR HANDLERS SHALL SHUT DOWN PER THE DESIGNATED SEQUENCE. 4. AN ALARM SIGNAL SHALL BE SENT TO THE FACP & NPU'S. 5. A SIGNAL SHALL BE SENT TO THE OWNERS CENTRAL STATION VIA DACT. 6. MAGNETIC DOOR HOLDERS SHALL RELEASE ON THE FLOOR OF INCIDENT ONLY. 7. ELEVATORS SHALL RECALL TO THE PRIMARY LEVEL OF EGRESS. 8. FIREHAT IN ELEVATOR CAB SHALL ILLUMINATE. 9. ALL FIRE SMOKE DAMPER SHALL ACTIVATE. UPON ACTIVATION OF THE ELEVATOR LOBBY SMOKE DETECTOR AT THE PRIMARY LEVEL OF EGRESS, THE FOLLOWING SHALL OCCUR: 1. ALL AUDIBLES WILL SOUND UNTIL SYSTEM IS SILENCED. 2. ALL STROBES WILL FLASH UNTIL SYSTEM IS RESET. 3. ALL AIR HANDLERS SHALL SHUT DOWN PER THE DESIGNATED SEQUENCE. 4. AN ALARM SIGNAL SHALL BE SENT TO THE FACP & NPU'S. 5. A SIGNAL SHALL BE SENT TO THE OWNERS CENTRAL STATION VIA DACT. 6. MAGNETIC DOOR HOLDERS SHALL RELEASE ON THE FLOOR OF INCIDENT ONLY. 7. ELEVATORS SHALL RECALL TO THE ALTERNATE LEVEL OF EGRESS. 8. FIREHAT IN ELEVATOR CAB SHALL ILLUMINATE. 9. ALL FIRE SMOKE DAMPER SHALL ACTIVATE. UPON ACTIVATION OF THE ELEVATOR MACHINE ROOM SMOKE DETECTOR, THE FOLLOWING SHALL OCCUR: 1. ALL AUDIBLES WILL SOUND UNTIL SYSTEM IS SILENCED. 2. ALL STROBES WILL FLASH UNTIL SYSTEM IS RESET. 3. ALL AIR HANDLERS SHALL SHUT DOWN PER THE DESIGNATED SEQUENCE. 4. AN ALARM SIGNAL SHALL BE SENT TO THE FACP & NPU'S. 5. A SIGNAL SHALL BE SENT TO THE OWNERS CENTRAL STATION VIA DACT. 6. MAGNETIC DOOR HOLDERS SHALL RELEASE ON THE FLOOR OF INCIDENT ONLY. 7. ELEVATORS SHALL RECALL TO THE PRIMARY LEVEL OF EGRESS. 8. FIREHAT IN ELEVATOR CAB SHALL ILLUMINATE. 9. ALL FIRE SMOKE DAMPER SHALL ACTIVATE. UPON ACTIVATION OF THE ELEVATOR TOP OF SHAFT SMOKE DETECTOR, THE FOLLOWING SHALL OCCUR: 1. ALL AUDIBLES WILL SOUND UNTIL SYSTEM IS SILENCED. 2. ALL STROBES WILL FLASH UNTIL SYSTEM IS RESET. 3. ALL AIR HANDLERS SHALL SHUT DOWN PER THE DESIGNATED SEQUENCE. 4. AN ALARM SIGNAL SHALL BE SENT TO THE FACP & NPU'S. 5. A SIGNAL SHALL BE SENT TO THE OWNERS CENTRAL STATION VIA DACT. 6. MAGNETIC DOOR HOLDERS SHALL RELEASE ON THE FLOOR OF INCIDENT ONLY. 7. ELEVATORS SHALL RECALL TO THE PRIMARY LEVEL OF EGRESS. 8. FIREHAT IN ELEVATOR CAB SHALL BLINK. 9. ALL FIRE SMOKE DAMPER SHALL ACTIVATE. UPON ACTIVATION OF A WATERFLOW SWITCH, THE FOLLOWING SHALL OCCUR. 1. ALL AUDIBLES WILL SOUND UNTIL SYSTEM IS SILENCED. 2. ALL STROBES WILL FLASH UNTIL SYSTEM IS RESET. 3. ALL AIR HANDLERS SHALL SHUT DOWN.PER THE DESIGNATED SEQUENCE. 4. AN ALARM SIGNAL SHALL BE SENT TO THE FACP & NPU'S. 5. A SIGNAL SHALL BE SENT TO THE OWNERS CENTRAL STATION VIA DACT. 6. MAGNETIC DOOR HOLDERS SHALL RELEASE ON THE FLOOR OF INCIDENT ONLY. 7. ALL FIRE SMOKE DAMPER SHALL ACTIVATE. 8. THE WATER FLOW BELL SHALL ACTIVATE UPON WATER FLOWING ONLY. 9. THE WATER FLOW BELL SHALL CONTINUE TO SOUND AS LONG AS WATER IS FLOWING. 10. THE WATER FLOW BELL SHALL•NOT BE SILENCEABLE FROM THE FACP. 11. THE EXISTING WATER FLOW BELL IS NOT CONNECTED TO THE FIRE ALARM PANEL (LOCAL 120VAC) UPON ACTIVATION OF ANY DUCT SMOKE DETECTOR THE FOLLOWING SHALL OCCUR: 1. A SUPERVISORY SIGNAL SHALL BE SENT TO THE FACP & NPU'S. 2. ALL AIR HANDLERS SHALL SHUT DOWN PER THE DESIGNATED SEQUENCE. 3. A SIGNAL SHALL BE SENT TO THE OWNERS CENTRAL STATION VIA DACT. 4. MAGNETIC DOOR HOLDERS SHALL RELEASE ON THE FLOOR OF INCIDENT ONLY. 5. ALL FIRE SMOKE DAMPER SHALL ACTIVATE. UPON ACTIVATION OF ANY TAMPER SWITCH THE FOLLOWING SHALL OCCUR: 1. A SUPERVISORY SIGNAL SHALL BE SENT TO THE FACP & NPU'S. 2. A SIGNAL SHALL BE SENT TO THE OWNERS CENTRAL STATION VIA DACT. UPON ACTIVATION OF A ELEVATOR HEAT DETECTOR LOCATED IN THE SHAFT OR MACHINE ROOM THE FOLLOWING SHALL OCCUR. 1. A SUPERVISORY SIGNAL SHALL BE SENT TO THE FACP & REMOTE ANNUNCIATOR. 2. A SUPERVISORY SIGNAL SHALL BE SENT TO THE OWNERS REMOTE STATION VIA DACT. 3. THE SIGNAL WILL BE SENT TO THE SHUNT SWITCH FOR POWER SHUTDOWN. UPON ACTIVATION OF A DUCT SMOKE DETECTOR, THE FOLLOWING SHALL OCCUR. 1. A SUPERVISORY SIGNAL SHALL BE SENT TO THE FACP & REMOTE ANNUNCIATOR. 2. A SUPERVISORY SIGNAL SHALL BE SENT TO THE OWNERS REMOTE STATION VIA DACT. 3. THE AIR HANDLER UNIT ASSOCIATED WITH THAT DUCT DETECTOR SHALL SHUT DOWN. SCOPE Q1 SYMBOL SIMPLEX MODEL # DESCRIPTION OF WORK EXISTING 1. PR ❑VIDE & INSTALL FIRE ALARM SYSTEM AS SHOWN ON DRAWINGS, FIRE WATCH XVI 2, SIGNALING LINE CIRCUIT WIRING SHALL BE STYLE 4. 3. NOTIFICATION APPLIANCE CIRCUIT WIRING SHALL BE STYLE Y. 4, THIS ,SYSTEM SHALL BE A CERTIFICATED OF PLACARDED CENTRAL STATION SERVICE PER C D NFPA- 72.8.2 EXISTING FARADAY REMOTE ANNUNCIATOR E VP 5, ADD ONE PULL STATION, ONE STROBE & 13 WEATHERPROOF HEAT DEECTORS TO ELEVATOR 1 & 2 LOBBY, 6. ADD ONE PULL STATION, ONE STROBE & 7 WEATHERPROOF HEAT DETETORS FOR ELEVATOR SHUNT TRIP SD AND CAPTURE OPERATION TO ELEVATOR 3. EXISTING FARADAY PHOTO DETECTOR ID 7, ADD ONE HEAT DETECTOR TO ELEVATOR 8 LOBBY. 9447 8. ADD ONE PULL STATION, ONE PHONE JACK & ONE HEAT DETECTOR TCELEVATOR 11 LOBBY, 9. ADD ONE PULL STATION & ONE STROBE TO DAY CARE CENTER ELEATOR LOBBY. I@= 10, ADD TWO IAMS TO MONIT ❑R ONE FLOW AND ONE TAMPER SWITCH IN ;TAIR 6. .. SOUTH PARKING'S SEQUENCE OF OPERATION: UPON ACTIVATION OF ANY MANUAL STATION THE FOLLOWING SHALL OCCUR: 1. ALL HORNS WILL SOUND UNTIL SYSTEM IS SILENCED. 2. ALL STROBES WILL FLASH UNTIL SYSTEM IS SILENCED. 3. AN ALARM SIGNAL SHALL BE SENT TO THE FACP & REMOTE ANNUNCIATOR. 4. A SIGNAL SHALL BE SENT TO THE OWNERS LISTED CENTRAL STATION VIA DACT. UPON ACTIVATION OF ANY AUTOMATIC DEVICE THE FOLLOWING SHALL OCCUR: 1. ALL HORNS WILL SOUND UNTIL SYSTEM IS SILENCED. 2. ALL STROBES WILL FLASH UNTIL SYSTEM IS SILENCED. 3. AN ALARM SIGNAL SHALL BE SENT TO THE FACP & REMOTE ANNUNCIATOR. 4. A SIGNAL SHALL BE SENT TO THE OWNERS LISTED CENTRAL STATION VIA DACT. UPON ACTIVATION OF THE ELEVATOR LOBBY HEAT DETECTORS (WITH THE EXCEPTIN OF THE ELEVATOR LOBBY DETECTOR AT THE PRIMARY LEVEL OF EGRESS), THE FOLLOWING SHALL OCCUR: 1. ALL HORNS WILL SOUND UNTIL SYSTEM IS SILENCED. 2. ALL STROBES WILL FLASH UNTIL SYSTEM IS SILENCED. 3. AN ALARM SIGNAL SHALL BE SENT TO THE FACP & REMOTE ANNUNCIATOR. 4. A SIGNAL SHALL BE SENT TO THE OWNERS LISTED CENTRAL STATION VIA DACT. 5. ELEVATORS SHALL RECALL TO THE PRIMARY LEVEL OF EGRESS. UPON ACTIVATION OF THE ELEVATOR LOBBY HEAT DETECTOR AT THE PRIMARY LEVEL OF EGRESS, THE FOLLOWING SHALL OCCUR: 1. ALL HORNS WILL SOUND UNTIL SYSTEM IS SILENCED. 2. ALL STROBES WILL FLASH UNTIL SYSTEM IS SILENCED. 3. AN ALARM SIGNAL SHALL BE SENT TO THE FACP & REMOTE ANNUNCIATOR. 4. A SIGNAL SHALL BE SENT TO THE OWNERS LISTED CENTRAL STATION VIA DACT 5. ELEVATORS SHALL RECALL TO THE ALTERNATE LEVEL OF EGRESS. UPON ACTIVATION OF THE ELEVATOR MACHINE ROOM SMOKE DETECTOR, THE FOLOWING SHALL OCCUR: 1. ALL HORNS WILL SOUND UNTIL SYSTEM IS SILENCED. 2. ALL STROBES WILL FLASH UNTIL SYSTEM IS SILENCED. 3. AN ALARM SIGNAL SHALL BE SENT TO THE FACP & REMOTE ANNUNCIATOR. 4. A SIGNAL SHALL BE SENT TO THE OWNERS LISTED CENTRAL STATION VIA DACT. 5. ELEVATORS SHALL RECALL TO THE PRIMARY LEVEL OF EGRESS. UPON ANY SYSTEM TROBLES, THE FOLLOWING SHALL OCCUR. 1. A TROUBLE SIGNAL SHALL BE SENT TO THE FACP & REMOTE ANNUNCIATOR. 2. A TROUBLE SIGNAL SHALL BE SENT TO THE OWNERS LISTED CENTRAL STATION VIA DACT. NOTES- MAIN BUILDING'S WIRE LEGEND A = INITIATING DEVICE CIRCUIT - IDC 2 #14 AWG THHN B = NOTIFICATION APPLIANCE CIRCUIT- NACNISUAL 2 #12 AWG THHN C= AUXILIARY CONTROL CIRCUIT -ACC 2 #14 AWG THHN ' D = VOICE COMMUNICATION CIRCUIT - VCC 18/2 TWISTED SHIELDED PAIR - NPLF F = FIRE FIGHTERS TELEPHONE CIRCUIT - FTC 18/2 TWISTED SHIELDED PAIR - NPLF MN = MULTI - ADDRESSABLE PERIPHERAL NETWORK - MAPNET 18/2 TWISTED /SHIELDED PAIR - NPLF MP= MAPNET POWER CIRCUIT - APC 2 #14 AWO THHN PAVILION BUILDING'S WIRE LEGEND A = INITIATING DEVICE CIRCUIT- IDC 14/2 FPL B = NOTIFICATION APPLIANCE CIRCUIT - NAC /AUDIBLE 14/2 FPL ' C = AUXILIARY CONTROL CIRCUIT - ACC 14/2 FPL ' D= VOICE COMMUNICATION CIRCUIT - VCC 18/2 TWISTED SHIELDED PAIR FPL F = FIRE FIGHTERS TELEPHONE CIRCUIT - FTC 18/2 TWISTED SHIELDED PAIR FPL MN = MULTI - ADDRESSABLE PERIPHERAL NETWORK - MAPNET 18/2 TWISTED /SHIELDED PAIR FPL MP= MAPNET POWER CIRCUIT - APC 14/2 FPL' S = SYNC WIRE 12/2 FPL DN = DATA COMMUNICATIONS NETWORK - COMNET 18/2 TWISTED /SHIELDED PAIR FPL I DAY CARE CENTER'S SYMBOL LEGEND DEVICES ^ " SYMBOL SIMPLEX MODEL # DESCRIPTION EXISTING w FACP FIRE WATCH XVI EXISTING FARADAY FIRE ALARM CONTROL PANEL FARADAY W 120VAC C :j PS SERIES EXISTING WHEELOCK NAC POWER SUPPLY C D 7700 SERIES EXISTING FARADAY REMOTE ANNUNCIATOR E VP 10560 EXISTING FARADAY PULL STATION 10565 EXISTING FARADAY WEATHERPROOF PULL STATION BACK BOX ❑F 10560 EXISTING FARADAY PULL STATION SD 9187 EXISTING FARADAY PHOTO DETECTOR ID 9188 EXISTING FARADAY ION DETECTOR O 9447 EXISTING FARADAY HEAT DETECTOR R 302 -AW WEATHERPROOF HEAT DETECTOR (1 v„P C) ELEVATOR OPERATION I@= 8424 EXISTING FARADAY ION DUCT DETECTOR FS a EXISTING FLOW DETECTOR SWITCH w_j11 tr FURNISHED BY DIVISION 15 TS �LLMM �W `t EXISTING TAMPER (GATE VALVE) SWITCH q. FURNISHED BY DIVISION 15 Scd L 5508 EXISTING FARADAY STROBE 0.080 AMPS ® 75CD 4904 -9169 NEW SIMPLEX STROBE 0.095 AMPS 75CD 6235 EXISTING FARADAY HORN /STROBE 0.095 AMPS 75CD 6235 EXISTING FARADAY HORN /STROBE 0.095 AMPS VP 3014B EXISTING FARADAY WEATHERPROOF BACK BOX J -1 END OF LINE RESISTOR END OF LINE RELAY L CONNECTION TO AN APPROVED, DEDICATED m EARTHGROUND, NFPA 70. COMPLY WITH NEC. 120vAC 120VAC SOURCE DEDICATED BREAKER N%% - COMPLY WITH NFPA 70. zw �w EXISTING ELEVATOR ELEVATOR CONTROLLER Q FURNISHED BY OTHERS ojo CONTROLLER y 120VAC � J oQ 91 30CD 6235 EXISTING FARADAY HORN /STROBE 0.095 AMPS O z DAY CARE CENTER'S SEQUENCE OF OPERATION: UPON ACTIVATION OF ANY MANUAL STATION THE FOLLOWING SHALL OCCUR: 1. ALL HORNS WILL SOUND UNTIL SYSTEM IS SILENCED. 2. ALL STROBES WILL FLASH UNTIL SYSTEM IS SILENCED. 3. AN ALARM SIGNAL SHALL BE SENT TO THE FACP & REMOTE ANNUNCIATOR. 4. A SIGNAL SHALL BE SENT TO THE OWNERS LISTED CENTRAL STATION VIA DACT. UPON ACTIVATION OF ANY AUTOMATIC DEVICE THE FOLLOWING SHALL OCCUR: 1. ALL HORNS WILL SOUND UNTIL SYSTEM IS SILENCED. 2. ALL STROBES WILL FLASH UNTIL SYSTEM IS SILENCED, 3. AN ALARM SIGNAL SHALL BE SENT TO THE FACP & REMOTE ANNUNCIATOR. 4. A SIGNAL SHALL BE SENT TO THE OWNERS LISTED CENTRAL STATION VIA DACT. UPON ACTIVATION OF THE ELEVATOR LOBBY HEAT DETECTORS (WITH THE EXCEPTION OF THE ELEVATOR LOBBY DETECTOR AT THE PRIMARY LEVEL OF EGRESS), THE FOLLOWING SHALL OCCUR: 1. ALL HORNS WILL SOUND UNTIL SYSTEM IS SILENCED. 2. ALL STROBES WILL FLASH UNTIL SYSTEM IS SILENCED. 3. AN ALARM SIGNAL SHALL BE SENT TO THE FACP & REMOTE ANNUNCIATOR. 4. A SIGNAL SHALL BE SENT TO THE OWNERS LISTED CENTRAL STATION VIA DACT. 5. ELEVATORS SHALL RECALL TO THE PRIMARY LEVEL OF EGRESS. UPON ACTIVATION OF THE ELEVATOR LOBBY HEAT DETECTOR AT THE PRIMARY LEVEL OF EGRESS, THE FOLLOWING SHALL OCCUR: 1. ALL HORNS WILL SOUND UNTIL SYSTEM IS SILENCED. 2. ALL STROBES WILL FLASH UNTIL SYSTEM IS SILENCED. 3. AN ALARM SIGNAL SHALL BE SENT TO THE FACP & REMOTE ANNUNCIATOR. 4. A SIGNAL SHALL BE SENT TO THE OWNERS LISTED CENTRAL STATION VIA DACT. 5. ELEVATORS SHALL RECALL TO THE ALTERNATE LEVEL OF EGRESS. UPON ACTIVATION OF THE ELEVATOR MACHINE ROOM SMOKE DETECTOR, THE FOLLOWING SHALL OCCUR: 1. ALL HORNS WILL SOUND UNTIL SYSTEM IS SILENCED. 2. ALL STROBES WILL FLASH UNTIL SYSTEM IS SILENCED. 3. AN ALARM SIGNAL SHALL BE SENT TO THE FACP & REMOTE ANNUNCIATOR. 4. A SIGNAL SHALL BE SENT TO THE OWNERS LISTED CENTRAL STATION VIA DACT. 5. ELEVATORS SHALL RECALL TO THE PRIMARY LEVEL OF EGRESS. UPON ANY SYSTEM TROBLES, THE FOLLOWING SHALL OCCUR. 1. A TROUBLE SIGNAL SHALL BE SENT TO THE FACP & REMOTE ANNUNCIATOR. 2. A TROUBLE SIGNAL SHALL BE SENT TO THE OWNERS LISTED CENTRAL STATION VIA DACT. UPON ACTIVATION OF A TAMPER SWITCH, THE FOLLOWING SHALL OCCUR. 1. A SUPERVISORY SIGNAL SHALL BE SENT TO THE FACP & REMOTE ANNUNCIATOR. 2. A SUPERVISORY SIGNAL SHALL BE SENT TO THE OWNERS LISTED CENTRAL STATION VIA DACT. UPON ACTIVATION OF A DUCT SMOKE DETECTOR, THE FOLLOWING SHALL OCCUR. 1. A SUPERVISORY SIGNAL SHALL BE SENT TO THE FACP & REMOTE ANNUNCIATOR. 2. A SUPERVISORY SIGNAL SHALL BE SENT TO THE OWNERS LISTED CENTRAL STATION VIA DACT. 3. THE AIR HANDLER UNIT ASSOCIATED WITH THAT DUCT DETECTOR SHALL SHUT DOWN. UPON ACTIVATION OF THE ELEVATOR TOP OF SHAFT, OR ELEVATOR MACHINE ROOM HEAT DETECTOR, THE FOLLOWING SHALL OCCUR: 1. A SUPERVISORY SIGNAL SHALL BE SENT TO THE FACP & REMOTE ANNUNCIATOR. 2. A SUPERVISORY SIGNAL SHALL BE SENT TO THE OWNERS LISTED CENTRAL STATION VIA DACT. 3. ELEVATOR SHALL LOSS POWER (SHUNT TRIP). UPON ACTIVATION OF A WATERFLOW SWITCH, THE FOLLOWING SHALL OCCUR. 1. ALL HORNS WILL SOUND UNTIL SYSTEM IS SILENCED. 2. ALL STROBES WILL FLASH UNTIL SYSTEM IS SILENCED. 3. AN ALARM SIGNAL SHALL BE SENT TO THE FACP & REMOTE ANNUNCIATOR. 4. A SIGNAL SHALL BE SENT TO THE OWNERS LISTED CENTRAL STATION VIA DACT. 5. ALL AIR HANDLER UNITS SHALL SHUT DOWN. 6. THE WATER FLOW BELL SHALL ACTIVATE UPON WATER FLOWING ONLY. 7. THE WATER FLOW BELL SHALL CONTINUE TO SOUND AS LONG AS WATER IS FLOWING. 8. THE WATER FLOW BELL SHALL NOT BE SILENCEABLE FROM THE FACP. 9. THE EXISTING WATER FLOW BELL IS NOT CONNECTED TO THE FIRE ALARM PANEL (LOCAL 120VAC). DAY CARE CENTER & SOUTH PARKING'S WIRE LEGEND A = INITIATING DEVICE CIRCUIT - IDC 2 # 14 FPL OR THHN CONDUCTORS MINIMUM C = AUXILIARY CONTROL CIRCUIT - ACC 2 # 14 FPL OR THHN CONDUCTORS MINIMUM L = NOTIFICATION APPLIANCE CIRCUIT - NAC 2 # 14 FPL OR THHN CONDUCTORS MINIMUM P'= POWER SUPERVISORY CIRCUIT - PSC 2 # 14 FPL OR THHN CONDUCTORS MINIMUM w W W zQ Q w j LL W Mi LL V Q C) Q a "' H 04 Z rz WONOO �0M70°o a ct) 4 w_j11 tr �LLMM �W `t �. q. I� q. V C) 0) 0) ( O U.) ;k 1n 6- W EL 'T- 6- � U J -1 z W m Q) J O w W zw �w 2 0 Q U) Of y � J oQ O z 52 X z O m O a zo z w L) U F U N w O D °d O z U L7 U >Q m O J E w � w 0 W � L 0 o: m U � U U U w r- a 0 Ln m O z •- _2 U aw _2 0 z a �0 o5 c; m j < Lu C b W $ O �IU 'a0 U) v J� �0 3e LL LL Uwi T � w } zU pp; F4 z m W w w N W U O 0 N J o o z CO g J a XU J E 0 U U w L) z z U) w U z7 `� m LL � (L w w L) _U Z O w w It 0 F- D- 5 W 0 a J a O v) Q i m o m Q yy 1� 1 F- U O 1--1 E--4 z o OZ U ZZWz W J z� z EL J O F- FF�� F-1 W U Z Z W ? w U N iE J J O z �Q gU p Z D J ITV' co .-i L7 w Q.' fn J n- M SSw S to CL M U)oz O " Zo za O �o I0>w zZ a C'7 g -i(L ao DRAWN BY: DATE: CCRJR 5/26/11 DESIGNED BY: DATE: CCRJR 5/26/11 APPROVED BY: DATE: PROJECT NUMBER: 263- 409382 /957182917 - 957048316 SHEET TITLE/ PATH: \\Sgmiami 1\DRAFTI NG\00- 2003\SOUTH MIAMI HOSPITAL (MASTER SITE)\SMH Elevator Renovation 957048316 REV01 SHEET NUMBER: NOTES -2 SM D QPXJC)