12-310-002Wire Leger Letter Typical Use LV-1 Card Reader 1 - 1118 LV -2 Door Contact / REX 1 -11118 LV -3 Lock 1-1118 r-- - -- I i TO EXI: ETHER I NETWC L---- CR #01 8E 02 CR #03 CR #04 CR #05 CR #06 o-a o-1 a o->I o->I 3RD FL — — — — Ceiling /irrirrrrnrii J -Box 4 D. Contact 3RD FL ELECTRIFIED LOCK FAIL SECURE W/ACCESS READER FRONTMEW SIDE VIEW To Access Control Panel 1/2' Flex J -Box _ _ J -Bax — — — — Ceiling /irrirrrrnrii J -Box 4 D. Contact I T -RD( I I I 3 I I 2 I Card Reader if I I � lJ­ Electronics la QElectronic Electnfled hinge lncicset Q '0 Loi 00 Provided by h rs Secured Side Non Secured Side �geA Door is always locked from outside, access to secured area is only possible by presenting authorized card to card reader or by using bypass key. OPERATION This door is always unlocked in the direction of egress. Activation of inside lock lever will allow free egress at all times. Activation of the building automatic sprinkler or fire detection system, if provided, shall automatically unlock the doors in the direction of egress and the doors shall remain unlocked until the fire protective signaling system has been manually reset. In the event of a fire alarm or power failure will result in immediate release of the door lock allowing free travel in both directions. (As required by NFPA 101: 7.2.1.6.2) INSTALLATION EQUIPMENT O1 Provide single gang junction box flushed mounted 48- A F.F. (1) Card Reader for card reader on the non secured side. (1) Electrified mortisse cossete FAIL SECURE ODrill hole for door power cord (1) Recessed Door Contact ODrill hole in top of door for door contact. (As required by NFPA 101: 7.2.1 6.2) 0 Stub flex conduit from junction box into door contact. EQUIPMENT (1) Card Reader NFPA COMPLIANCE O Single gang box concealed in wall for RTE motion sensor (1) Set of Delayed Maglocks NFPA 101: 7.2 1.5 Stub 112" or 3/8" flex conduit down door frame on the lock NFPA 101: 7.2.1.6.2 O6 side of the door to junction box located above accessible ceiling ELECTRIFIED LOCK OPERATION This door is always unlocked in the direction of egress. FAIL SECURE Activation of the building automatic sprinkler or fire detection system, if provided, shall Push door until alarm sounds. WITH ACCESS READER (D ---- - - - - -- v Push door until alarm sounds. Door will unlock in 15 seconds.) I L------- - - - - -J Through Penetration Firestop System : SYSTEM N0. W -L -1001 (FORMERLY SYSTEM NO. 147) F Ratings -1, 2, 3 and 4 Hr (See Items 2 and 3) T Ratings -0, 1, 2, 3, and 4 Hr (See Item 3) L Rating At Ambient -less than 1 CFM /sq ft L Rating At 400 F -less than 1 CFM /sq ft 1. Wall Assembly -The 1, 2, 3 or 4 hr fire -rated gypsum wallboard /stud wall assembly shall be constructed of the materials and in the manner described in the individual U300 or U400 Series Wall or Partition Designs in the UL Fire Resistance Directory and shall include the following construction features: A. Studs - Wall framing may consist of either wood studs (max 2 h fire rated assemblies) or steel channel studs. Wood studs to consist of nom 2 by 4 in. lumber spaced 16 in. OC with nom 2 by 4 in. lumber end plates and cross braces. Steel studs to be min 3 -5/8 in. wide by 1 -3/8 in. deep channels spaced max 24 in. OC. B. Gypsum Board* -Nom 1/2 or 5/8 in. thick, 4 ft. wide with square or tapered edges. The gypsum wallboard type, thickness, number of layers, fastener type and sheet orientation shall be as specified in the individual U300 or U400 Series Design in the UL Fire Resistance Directory. Max diam of opening is 13 -1/2 in. 2. Pipe or Conduit -Nom 12 in. diam (or smaller) Schedule 10 (or heavier) steel pipe, nom 12 in. diam (or smaller) service weight (or heavier) cast iron soil pipe, nom 12 in. diam (or smaller) Class 50 (or heavier) ductile iron pressure pipe, nom 6 in. diam (or smaller) steel conduit, nom 4 in. diam (or smaller) steel electrical metallic tubing, nom 6 in. diam (or smaller) Type L or (or heavier) copper tubing or nom 1 in. diam (or smaller) flexible steel conduit. When copper pipe is used, max F Rating of firestop system (Item 3) is 2 h. Steel pipes or conduits larger than nom 4 in. diam may only be used in walls constructed using steel channel studs. A max of one pipe or conduit is permitted in the firestop system. Pipe or conduit to be installed near center of stud cavity width and to be rigidly supported on both sides of wall assembly. 3. Fill, Void or Cavity Material* - Caulk -Caulk fill material installed to completely fill annular space between pipe or conduit and gypsum wallboard and with a min 1/4 in. diam bead of caulk applied to perimeter of pipe or conduit at its egress from the wall. Caulk installed symmetrically on both sides of wall assembly. The hourly F Rating of the firestop system is dependent upon the hourly fire rating of the wall assembly in which it is installed, as shown in the following table. The hourly T Rating of the firestop system is dependent upon the type or size of the pipe or conduit and the hourly fire rating of the wall assembly in which it is installed, as tabulated below: Max Pipe Annular F T or Conduit Space, Rating, Rating, Diam, In In Hr Hr 1 O to 3/16 1 or 2 0 +,1 or 2 1 1/4 to 1/2 3or4 3or4 4 0 to 1 -112 1 or 2 0 6 1/4 to 112 3or4 0 12 3116 to 3/8 1 or 2 0 +When copper pipe is used, T Rating is 0 h. 3M COMPANY -CP 25WB +. *Bearing the UL Classification Markin g MAGNETIC LOCK FOR DOUBLE DOOR WITH CARD READER (A.D.O.) FRONT VIEW SIDE VIEW To Acce» Control Panel and fire Alarm Connection J -Bon Ceiling line J -Bax tic — — Door - enl L � tic Dix r DE DE �otnerl DELAYED MAG -- 7, 1777 I — — Door Contact I DE DE I I I �J I tL Q i>D Secured Side Non Seared Side Door is always locked from outside, access to secured area is only possible by OPERATION presenting authorized card to card reader or by using bypass key. This door is always unlocked in the direction of egress. Activation of the building automatic sprinkler or fire detection system, if provided, shall automatically unlock the doors in the direction of egress and the doors shall remain unlocked until the fire protective signaling system has been manually reset. In the event of a fire alarm or power failure the doors will remain unlocked in the direction of egress. (As required by NFPA 101: 7.2.1 6.2) EQUIPMENT (1) Card Reader Non Secured Side (1) Automatic Door Operator (1) Set of Delayed Maglocks — — — — — — — — — NFPA COMPLIANCE NFPA 101: 7.2.1.6.2 OPERATION This door is always unlocked in the direction of egress. MAGNETIC LOCK Activation of the building automatic sprinkler or fire detection system, if provided, shall Push door until alarm sounds. FOR DOUBLE DOOR D-2 unlocked until the fire protective signaling system has been manually reset. WITHOUT CARD READER In the event of a fire alarm or power failure the doors will remain unlocked in the Secluence of Operation5 for Access Controlled Doors Access controlled Door with Electric Lock5et IN ACCORDANCE WITH NFPA 10 1 -2000 7.2.1.5 I .- Door i5 in the secure position when closed, the door status contact is lined up and the locking mechanism has engaged. - 2.- To enter the door the person must present a valid card at the card reader, after verification -the system will -- - - -- grant access thru the door by releasing the lock for a set period of time. 3.- When someone approaches the door from the secure side to exit the' area, the Request To Exit (REX) motion - detector shall detect the presence of a person and set the system in REX mode ma5king the door status 2854 CORPORATE WAY ' contact. The lock built into the frame stays secure while the knob /handle can be released by the person turning . FL 33025 the knob /handle, allowing free egress. MIRAMAR 954 - 391 -4501 *FAX 954 - 391 -4573 ' 4.- In the event of a system failure, the person can exit the area byning the knob /handle, allowing free egress. 5.- In the event of a Fire Alarm detected by the Fire Alarm 5y5te , a person can exit the area by turning the (c) Copyright 2011 KRATOS I HBE knob /handle, allowing free egre55. All Rights Reserved. Access controlled Door with Delayed Egress Electra- Magnetic Locks IN ACCORDANCE WITH NFPA 10 1 -2000 7.2.1 G. I ( 1 -5) I .- Door 15 in the secure position when closed, the door status contact 15 lined up and the locking mechanism has engaged. 2.- To enter or exit thru the door the person must present a valid card at the card reader, after verification the system will grant access thru the door by releasing the lock for a set period of time. 3.- In the event of a system failure, the person can exit by push against the door, activating the delayed egress feature. This will immediately alert the security personnel and automatically release the lock after 15 seconds. 4.- In the event of a Fire Alarm detected by the Fire Alarm System, the system will release the lock, allowing free egress. THE ACCESS CONTROL SYSTEM PROVIDED ON THIS PROJECT COMPLIES WITH THE FOLLOWING CODE: NFPA 101 Life Safety Code® 2006 Edition 7.2. 1 .5 Locks, Latches, and Alarm Devices. 7.2.1 .5. 1 Doors shall be arranged to be opened readily from the egress side whenever the building 15 occupied. 7.2.1 G. I Delayed- Egress Locks: Approved, listed, delayed- egress locks shall be permitted to be installed on doors serving low and ordinary hazard contents in buildings protected throughout by an approved, supervised automatic fire detection system in accordance with Section 9.G or an approved, supervised automatic sprinkler system in accordance with 5ection 9.7, and where permitted in Chapter 12 through Chapter 42, provided that the following criteria are met: ( I ) T he provisions of 7.2. 1 .G.2 for access- controlled egress doors shall not apply to doors with delayed- egress locks. (2) T he doors shall unlock upon actuation of one of the following: (a) Approved, supervised automatic Sprinkler system in accordance with Section 9.7 (b) Not more than one heat detector of an approved, supervised automatic fire detection system in accordance with Section 9.G (c) Not more than two smoke detectors of an approved, supervised automatic fire detection system in accordance with Section 9.G (3) T he doors shall unlock upon 1055 of power controlling the lock or locking mechanism. (4)* A n irreversible process shall release the lock within 15 seconds, or 30 seconds where approved by the authority having jurisdiction, upon application of a force to the release device required in 7.2. 1.5.9 under the following conditions: (a) The force shall not be required to exceed 15 IV (G7 N). (b) The force shall not be required to be continuously applied for more than 3 seconds. (c) The Initiation of the release process shall activate an audible Signal in the vicinity of the door. (d) Once the door lock has been released by the application of force to the releasing device, relocking shall be by manual means only. (5)* A readily visible, durable sign in letters not Ie55 than I in. (25 mm) high and not less than In. (3.2 mm) in stroke width on a contrasting background that reads as follows shall be located on the door adjacent to the release device: PU5H UNTIL ALARM 50UND5 DOOR CAN BE OPENED IN 15 SECONDS DOUBLE DOOR WITH IN /OUT ACCESS READER FRONT VIEW I SIDE VIEW INSTALLATION I EQUIPMENT (2) Cord Reader (1) Automatic Door Operator (1) Set of Delayed Maglocks NFPA COMPLIANCE NFPA 101: 7.2.1 6 2 DOUBLE DOOR WITH IN /OUT ACCESS D-3 READER MUST BE SIGNED BY KRATOS I HBE TO AUTHENTICATE CONTENT(S). ALL DETAILS CHECKED FOR ACCURACY. SIGNATURE DATE KRATOS I HBE JOB # 1 -1 LQXEW CONFIDENTIAL THE INFORMATION CONTAINED HERIN MAY NOT BE USED OR REPRODUCED IN ANY MANNER WITHOUT WRITTEN PERMISSION OF KRATOS I HBE. y t c s L • I . - Y — ..t tz tr y. t� ,r HIIIIIIIIIIII1 REV I DESCRIPTION CUSTOMER: South Miami Hospital PROJECT: MH 3rd floor NICU Level II DRAWING TITLE: Sercuity Notes and Details N DRN BY DATE DRN CHK BY DATE CJJK J.P. 01/11/12 M.O.S. 01/11/12 SCALE: NTS DWG NO. SEC -500 To Access Control Panel r - -- J -Bax / T// T/ 77TlTTl/// T1/ ��17T1771 //71/�//T//7777771777// C•ellln line I I Door Contact I DE DE I I I Single Gang Box 1 48' aff on unsecured side Wan (Typical) �0 I a a a a Secured 51d� Non Secured Side — — — — — — — — — Door is always locked from outside, access to secured area is only possible by presenting authorized card to card reader or by using bypass key. OPERATION This door is always unlocked in the direction of egress. I Activation of the building automatic sprinkler or fire detection system, if provided, shall Push door until alarm sounds. automatically unlock the doors in the direction of egress and the doors shall remain Door will unlock In 15 seconds.) unlocked until the fire protective signaling system has been manually reset. In the event of a fire alarm or power failure the doors will remain unlocked in the L— — — — — — — — — — — — J direction of egress. (As required by NFPA 101: 7.2.1.6.2) INSTALLATION I EQUIPMENT (2) Cord Reader (1) Automatic Door Operator (1) Set of Delayed Maglocks NFPA COMPLIANCE NFPA 101: 7.2.1 6 2 DOUBLE DOOR WITH IN /OUT ACCESS D-3 READER MUST BE SIGNED BY KRATOS I HBE TO AUTHENTICATE CONTENT(S). ALL DETAILS CHECKED FOR ACCURACY. SIGNATURE DATE KRATOS I HBE JOB # 1 -1 LQXEW CONFIDENTIAL THE INFORMATION CONTAINED HERIN MAY NOT BE USED OR REPRODUCED IN ANY MANNER WITHOUT WRITTEN PERMISSION OF KRATOS I HBE. y t c s L • I . - Y — ..t tz tr y. t� ,r HIIIIIIIIIIII1 REV I DESCRIPTION CUSTOMER: South Miami Hospital PROJECT: MH 3rd floor NICU Level II DRAWING TITLE: Sercuity Notes and Details N DRN BY DATE DRN CHK BY DATE CJJK J.P. 01/11/12 M.O.S. 01/11/12 SCALE: NTS DWG NO. SEC -500