Loading...
12-271-020NOTE. THE DETAIL5 ON TH15 SHEET AfRE GONSIDEfRED T*rF[C,,4L AND AFE NOT NECE55AfRILT' CALLED OUT ON PLAN& NOTE. ALL RATED PENETRATION DETAILS ON THIS SHT. ARE TO COMPLY WITH UNITED STATES GYPSUM COMPANY DETAILS FOR HOSPITAL AND INSTITUTIONAL CONSTRUCTION. HANDBOOK DATED FEBRUARY 1991, REVISED AUGUST Mel. EQUIVALENT DETAIL NUMBERS ARE SHOWN WHERE APPLICABLE woo < z� � v� 2" 0 �x W 0 Zo 10 • P=4 .11 0 P=4 PENN" cd 0 PE" P.= C6 as E 0 (a 1 410 Ulf, Q 4-0 Ild —11 1-4 c 0 W Z < Z a 00 Z Cie I. < LLI a Z LLI 914 PERMIT SET t 0 01 Sheet -1,4yJAd A-14 CW 15 JOB 201i3a TRACK OR BLOCKING BAR JOISTS CLIP $CREW METAL STUD 4'Ol 7 CD LABELLED ACCESS PANEL 5/6' TYPE 'X' FIRE RETARDANT CINDER OVER 6' UNDER T L -1/2, CRC FIRE RATED CEILING TREATED WOOD SEALANT STUDS iro, O.C. STUDS 161 O.C. 2 1/2' C ON FRTW BLOCK (2x4) PARALLEL TO STRUCTURE RATED PARTITION SECTION AT CEILING LNER PANEL A V_ J-RUNNER FASTEN TO E-STUDS STUDS 24' O.Ca STUDS 24' O.C. CHANNEL L :C: Ar 'LIFS TRACK OR BLOCKING –LABELLED ACCESS PANEL CD FLAN VIEW PLAN VIEW IMPALING C L I (2) PER STUD STUD BAR JOISTS J-F4MER SPACE FASTEN TO E 5CREUr NOTES: NOTES: CLIP AT EACH STUD OVER (I UNDER V 1. GYPSUM BOARD APPLIED VERTICALLY. L GYPSUM BOARD APPLIED VERTICALLY. 5/8' TYPE 'X' 2. JOINTS TO RECEIVE SHEETROCK TAPE AND JOINT COMPOUND. 2. JOINTS IN FINISH LAYER TO RECEIVE TAPE AND JOINT COMPOUND. SEALANT 2 1/2, 1C ON FRTW BLOCK (2x4) PLAN DETAIL AT SHAFT WALL SECTION RATFD PARTITION PENETRATION OF I-HR RA= CEILING ASSEMBLY RATED PARTITION REF. UL SYSTEM No. 409f REF. UL SYSTEM No. 418 NOTE: BLOCKING IN WALL IS REQUIRED TYPICAL JOINT REQUIREMENTS FOP, I HOUR WALL iLTz• �2) TYPICAL JOINT REQUIREMENTS FOP, 2 HOUR WALL RATED PARTITION PENETRATION DETAIL MEMBRANE EDGE SUPPORT DETAIL N.T.S. ACCESS PANEL INSTALLATION DETAIL PERPENDICULAR TO STRUCTURE - I OR 2 HOUR FIRE OR SECURE FIRE= RESISTIVE MATERIAL SMOKE WALL BRACE METAL STUDS ANGLE I'MR OVERLAP FIRE DAMPER SLEEVE 1, /: ACOUSTICAL SEALANT 2' -0' (PER UL) R UL) BACK AND SIDES OF BOX A$ NECESSARY FOR SOUND RATING OPTIONAL BREAKAWAY CONNECTION ONE OR TWO LAYERS OF DRYWALL 5/8' TYPE 'X' GYP. ED. OPENING TO BE _!5 LINED WITH FIRE I MATERIAL OF RATING WOOD STUD A AS REQUIRED FOR WALL CONST. II EQUAL TO THAT ON RESISTIVE THE WALL (REQUIRED ONE OR TWO LAYER OF DRYWALL ACOUSTICAL SEALANT TAPE AND FINISH BEHIND CABINET BY AHCA) AROUND BOX PENETRATION ALTERNATE 1: BLOW-CUT ONE ADJACENT ELECTRICAL BOXES MAXIMUM 16 SQ. N. STUDS SIZED AS REQUIRED FOR PIPI N*_\ STRAPS WRAPPED AROUND METAL STUDS MAY BE 51DE OF WALL TAPE 4 JOINT COMP. DRYWALL OR SEALANT MAXIMUM OPENING iw sa wob ST. -FIRE RATED ACOUSTIC CEILING ASSEMBLY CHANGE OF CEILING HEIGHT AT RATED CEILING USED ON 5001T U.I_ APPROVED E6FIRE DAMPER A55EMBLI IN PLACE OF FIRE DAMPER ANGLE IRON FRAMES. SLEEVE I'MIN. OVERLAP BREAKAWAY !11 METAL RUNNERS ALTERNATE 2. h XXXX I FACE TO BE SEALED WITH DRYWALL, SEALANT, OR TAPE TELEPHONE OR ELECTRICAL BOXES LAMINATE BACK PIECE TO WALLBOARD r – – – – – – – – – – – – – – CONNECTION OPTIONAL LINING OF AND JOINT COMPOUND NOTE: it OPENING: LOCAL 1�! OVER I' GAP REQUIRES A SECURE METAL STUD AUTHORITIES MAY REQUIRE WITH FIRE RESISTIVE OPENING TO BLOW -OUT PATCH BRACE MATERIAL OF RATING BE LINED SHALLOW FIVE SIDE BOX DETAIL ...... -7 EQUAL TO THAT ON THE REQUIRED WHERE BOX EXCEEDS Iro SQ. INCHES -METAL STUDS DAMPER REQUIRED (FIRE ONLY) WALL FOR SOME FIRE DAMPER INSTALLATIOK (NOT REQ'I BY AHCA) I' MIN. OVERLAP PACK WITH TH ERMAFIVER DENSITY WIT14 0 VOIDS OR GAPS OR AGGREGATE OF BOXES EXCEEDS 100 SQ. N./ ELECTRICAL JUNCTION BOXES r F VARIES T DUCT FIRE DAMPER SLEEVE BREAKAWAY I.T SECTION A-A WHEN A METALLIC JUNCTION BOX FOR ELECTRICAL RECEPTACLES OR SWITCHES 15 CONTAINED WITHIN A RATED WALL OF GYPSUM DRYWALL CONSTRUCTION AND AN OPENING 15 PROVIDED FOR THE BOX IN THE SURFACE 0 SQUARE INCHES, UNLESS OF THAT HCE AREA OF THE OPENING MAY NOT EXCEED 16 ELECT. PANEL, F.H.C. OR OTHER WALL MOUNTED CABINET ZFUR 5/8' THPE 'X' GYP. BD. CONNECTION ALTERNATE I OR 2 MAY BE USED ON EITHER SIDE OF WALL THE JUNCTION S A'5-SIDED APPROVED I I ONE SIDE OF PENETRATION MAY REMAIN OPEN. OX E) BY 5OX'(SEE ENCLOSED DETAILS). CONCRETE OR MASONRY THE AGGREGATE AREA OF ALL SUCH JUNCTION BOXES IN A RATED WALL NOT ENCLOSED BY WALL ABOVE AND BELOW I I I I I 111 InT FIRE RATED '5-SIDED BOXES' DESCRIBED ABOVE SHALL NOT EXCEED 100 SQUARE INCHES IN 100 SQUARE FEET OF WALL AREA AS MEASURED FROM FLOOR TO STRUCTURAL DECK OR RATED MEMBRANE. CEILING ASSEMBLY NOTE: JUNCTION BOXES WITH OPENINGS ON OPPOSITE FACES OF RATED WALLS SHALL HAVE A HORIZONTAL ASSEMBLY TRANS1`T1 SEPARATION OF 24 INCHES AS A MNIMUM, REGARDLESS OF BOX SIZE, UNLESS ENCLOSED BY NON RATED SPECIFIC FRAMING REQUIREMENTS OF OPENINGS '5-SIDED BOXES! CEILING ASSEMBLY SHOULD BE PROVIDED IN THE ARCHITECTURAL LOCATIONS OF STUDS DO NOT HAVE ANY BEARING ON THE ABOVE REQUIREMENTS, NOR DOES THE USE AND STRUCTURAL DRAWINGS THAT ARE SUBMITTED OF MINERAL WOOL FIRE SAFING ALTER THESE REQUIREMENTS. NOTE: 2 LAYERS 5/8' TYPE 'X' DRYWALL FOR BUILDING PEWITS. AT 2 HOUR RATED CEILING ASSEMBLY REF: UL SYSTEM No. U_ 1065 EQUIV: TO SKETCH 0 206, Ul HANDBOOK EQUIV.- TO SKETCH 101, USG, HANDBOOK BULKHEAD AT ONE-HOUR CEILING ASSEMBLY DAMPER SLEEVE INSTALLATION DETAIL MULTIPLE PIPE PENETRATION DETAIL TYPICAL FIVE SIDE BOX DETAIL N.T.S. RECESSED WALL CABINET DETAIL rtTS UO RATED ON RATED PARTITION Guide XHEZ Guide XHEZ October 03, 2001 Gulde XHEZ February 11, 112111 Through- Penetration Firestop Systems Through - Penetration Firestop Systems C-4.1-1000-A Card Through- Penetration Firestop Systems W-L-1088 A Card EXTEND WALL INTO OVER- HAWGAND PARAPET ABOVE AND/ORSILL BELOW system No. C-AJ-MO system No. W-L-1088 February 11, I9135 System No. W-L-5014 W-L-5014 A Card (Formerly System No. 636) SEAL ANY PENETRATIONS THRUWALL WITH ACOUSTICAL F-Rating - 3 Hr T-Rating 0 Hr F-Rating - I and 2 Hr (See Item 1) T-Rating - 0 Hr F-Ratio es - I and 2 Hr (See Item 1) By SEALANT - APPROVED T-Rating - I Hr 1/2' GYPSUM SHEATHING L Rating At Ambient Less Than I CFM/sq ft L Rating At 400 F Less Than I CFM/eq ft • COM Fi* L Ratio At Ambient Less Than I CFM/scl ft L Rating At 400 F Less Than I CFM/eq ft EXTERIOR WALL MATERIAL Bij)G. A ------- VVATEV A I #,IN EXTENSION DATE� 8 y 2 -7 A ........... ..... . ............ . ... 2 P ACOUST. SEALANT ..... ..... ........ 4 2 METAL STUDS AS REQV. FOR WIND LOAD A. TAPE 4 JOINT COMPOUND EXT. STUD WALL RUNNER 2 TRACK CONTINUOUS 3 L OF *,- 3 CITY SOU FLAN VIEW A BUILDING Section A-A A ... 1V Section A-4 STRUC U Al- EQUIV: TO SKETCH 601, USG, HANDBOOK (Cont. on C-AJ-1000-B Card) (Cont'd on W-L-1088 - B Card) 2 3 JV_ ...... 6er-tion A-A 9 1 FIRE N.TZ. AND/OR SMOKE WALL DETAIL AT EXTERIOR WALL 1. Floor or Wall Min 4-1/2 In. thick reinforced lightweight or normal weight 1. Wall Assembly - The I or 2 hr. fire-rated gypsum wallboard/stud wall assembly "it be 000-IE50 pc0=1'111te` Wall may also be constructed of any UL Classified Concrete Max diam constructed or the materials and In the manner described In the individual U300 or U400 Series Wall (Cont'd on W-L-5014 - 5 Card) Blocks•. or opening is 32 ln. or Partition Design In the UL Fire Resistance Directory and shall Include the following construction See concrete Block (CAZT) category in the Fire Resistance Directory for names or manufacturers. featurea-. A Studs - Wall framing may consist of either wood studs or steel channel studs. Wood studs to 1. Wall Assembly The I or 2 hr fire -rated gypsum wallboard /stud wall assembly shall be constructed of the materials and In the manner 2. Through Penetrants - One metallic pipe, conduit or tubing to be centered within consist of mom 2 by 4 11n, lumber spaced Iro In. O.C. with nom 2 by 4 In. lumber end plates and cross described In the Individual U300 or U400 Series Wall or Partition Design in the UL Fire Resistance Directory and shall include the following construction features: the firestop system. The annular space shall range from min 0 In. (point contact) to max 2 In. Pipe, conduit or tubing to be rIgIcI19 supported on both sides or floor or braces. Steel studs to be min. 3-5/8 in, wide and spaced max 24 in. O.C. B. Gypsum Board- - 5/8 In. thick, 4 Ft wide with square or tapered edges. The gypsum wallboard A. Studs - Wall framing may consist or either wood studs or steel channel studs. Wood studs to consist or nom 2 by 4 in. lumber spaced wall assembly. The following types and sizes of metallic pipes, conduits or tubing may type, thickness, number or layers, fastener type and sheet orientation shall be as specified in the 16 In. OC. Steel studs to be min 3-5/8 In. wide and spaced max 24 In. OC. be used: individual U300 or U400 Series Design in the UL Fire ReststanI Directory. Max diam of opening is B. Gypsum Board- - 5/8 In. thick, 4 ft. wide with square or tapered edges. The gypsum wallboard type, thickness, number of layers, A. Steel Pipe - Nom 30 In. diam (or smaller) Schedule 5 (or heavier) steel pipe, 6 -314 Im fastener type and sheet orientation shall be as specified in the individual U300 or U400 Series Design in the UL Fire Resistance B. Iron Pipe - Nom 30 In. diam (or smaller) cast or ductile Iron pipe. The F Ratting or the Firestop system Is equal to the hourly fire rating of the wall assembly In Directory. Max diam of opening is 18 in, C. Conduit - Nom 4 In. diam (or smaller) electrical metallic tubing or nom & In. clam which Installed. The hourly F Rating or the firestop system is equal to the hourly fire rating of the wall assembly In which It Is Installed. (or smaller) rigid galv steel conduit. 2. Through Penetrant - One metallic pipe, tubing or conduit to be installed eithe• concentrically 2. Through Penetrants - One metallic pipe or tubing to be installed either concentrically or eccentrically within the firestop system. Pipe or D. Copper Tubing - Nom & IrL diam (or smaller) Type M (or heavier) copper tubing. or eccentrically within the firestop system. The annular space between pipes, tubing or conduits and tubing to be rigidly supported on both sides of wall assembly. The following types and sizes of metallic pipes or tubing may be used. E. Copper Pipe - Nom ro In. diam (or smaller) Regular (or heavier) copper pipe. periphery of opening shall be min 0 In. (point contact) to max 5/8 In. Pipe, tubing or conduit to be A Steel Pipe - Nom 12 in. diam (or smaller) Schedule 10 (or heavier) steel pipe. 3. Firestop System - The firestop system "If consist of the following. rigidly supported on both &Ides or wall assembly. The Following types and sizes of metallic pipes, B. Iron Pipe - Nom 12 In. ciiafn (or smaller) cast or ductile Iron pipe. A Parking Material - (Optional, Not Show) - Mineral wool bats Insulation, backor rod or fiber bats insulation friction fitted into annular tubing or cordulte, may be used: A. eel Pipe - Nom & IrL diam (or smaller) Schedule 10 (or heavier) C. Copper Tubing - Nom 4 In. (or smaller) Type M (or heavier) copper tube. polyethylene glass steel pipe. D. Copper Pipe - Nom 4 Im (or smaller) Regular (or heavier) copper pipe. apace. Parking material to be recessed from top surface of floor or both surfaces B. Iron Pipe - Nom & In. diam (or smaller) cast or ductile from pipe. 3. Pipe Covel - One of the following types of pipe coverings shall be used. of wall as required to accommodate the required thIckriess or fill material. B. Fill, Void or Cavity Material- - Caulk - Min 1/2 in. thickness or fill material applied C. Copper TLA-.Xing - Nom 6 In. diam (or smaller) Type M (or heavier) copper tubing. D. Copper Pipe - Nom & In. diam (or smaller) Regular (or heavier) copper pipe. A Pipe and Equipment Covering Materials• - Max 2 IrL thick hollow cylindrical heavy density (min 3_5 per) glass fiber units Jacketed on within the annulus, flush with top surface of floor or with both surfaces of wall. At E. Condult - Nom 4 in. diam (or smaller) steel electrical metallic tubing, nom 4 In. diam (or smatter) the outside with an all service Jack—et. Longitudinal joints scaled with metal Fasteners or factory - applied self - sealing lap tape. Transverse joints secured with metal fasteners or with butt tape supplied with the product. The annular space between Insulated point contact location, apply min 1/4 in. diam bead or sealant at the pipe/concrete Interface on the top surface or the floor or both surfaces of wall. gaiv steel conduit or mom I in. (or smaller) flexible steel conduit. 3. Fill, Void or Cavity Materials - Sealant - Min 5/5 in. thickness of fill material within annulus, flush penetrating Item and the edge of the through opening "it be min 0 in. (continuous point contact) to max 1-1/4 in. SPECIFIED TECHNOLOGIES INC - 515'pecSeal 100, 101, 102,105,120 or 1129 Sealant with both surfaces of wall. Additional fill material installed such that a min 1/4 In. thick crown 16 formed See Pipe and Equipment Covering - Materials* - (BRSU) category In the Building Materials Directory for names of manufacturers. -Bearing the UL Classification Mark around the penetrating Item lapping 1/2 IrL beyond the perlpherg of the opening. Any pipe covering material meeting the above specifications and bearing the UL Classification Marking with a Flame Spread Index SPECIFIED TECHNOLOGIES INC: - LC 150,151152 and 155 Sealant or 25 or less and a Smoke Developed Index of 50 or less may be used. •Bearing the UL Classification Marking B. Pipe Covering Materials* - Max 2 in. thick unfaced mineral fiber pipe insulation having a nom density of 3_5 pcf (or heavier) and sized to the outside diam of pipe or tube. Pipe insulation secured with min 8 All steel wire spaced max 12 in. OC. The annular space between Insulated penetrating Item and the edge or the through opening "If be min 0 In. (continuous point contact) to max 1-114 In. OWENS CORNING HT INC, DIV OF OWENS CORNING - Paroc 1200, Paroc BWT or Paroc Thermaloc 1200 C. Sheathing Materiall, - Used in conjunction with Item 315. Foil -or-rim -kra ft or all service jacket material "if be wrapped around the outer clrcumlrerence or the pipe Insulation (Item 35) with the krart side exposed. Longitudinal joints and transverse joints sealed with metal fasteners or butt tape. See Sheathing Materials (BVDV) category In the Building Materials Directory for names or manufacturers. Any sheathing material meeting the above specifications and bearing the UL Classification Marking with a Flame Spread Index of 25 or less and a Smoke Developed Index of 50 or less may be used, 4. Fill, Vold or Cavity Material• - Sealant - Min 5/8 in. thickness of fill material applied within annulus, flush with both surfaces of wall. At point contact location between insulated through penetrant and gypsum wallboard, a min 316 IrL bead of fill material shall be applied to the Insulated through penetrant /gypsum wallboard Interface on both sides of the wall. SPECIFIED TECHNOLOGIES INC - Sper-Seal 100, 101, 102 and 105 Sealant •Bearing the I Classification Marking PENETRATION FIRESTOP DETAIL NTS. 18 PENETRATION FIRESTOP DETAIL PENETRATION FIRESTOP DETAIL N.T.S. woo < z� � v� 2" 0 �x W 0 Zo 10 • P=4 .11 0 P=4 PENN" cd 0 PE" P.= C6 as E 0 (a 1 410 Ulf, Q 4-0 Ild —11 1-4 c 0 W Z < Z a 00 Z Cie I. < LLI a Z LLI 914 PERMIT SET t 0 01 Sheet -1,4yJAd A-14 CW 15 JOB 201i3a