12-271-016WALL TYPE GENERAL NOTES: 1. GENERAL CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR THE APPROPRIATE CONSTRUCTION OF ALL WALL TYPES AND COORDINATION OF ALL MECHANICAL, ELECTRICAL, PLUMBING AND EXISTING CONDITIONS ADJACENT TO SUCH WALLS. SINCE THE WORK INVOLVES EXISTING BUILDING SYSTEMS AND FACILITIES, THE CONTRACTOR SHALL GIVE SPECIAL CONSIDERATION TO EXAMINATION OF ANY EXISTING CONDITIONS THAT WILL PREVENT THE CONSTRUCTION OF SUCH RATED WALLS AS PER PLANS. VARIATION OF TYPICAL RATED WALL TYPES DETAILS SHALL BE ANTICIPATED AND SHALL BE EXPRESSLY INCLUDED AS PART OF THE WORK WHENEVER REQUIRED, AT NO ADDITIONAL C05T TO THE OWNER A/E WILL SUPPLY THE DIFFERENT DETAILS FOR SUCH WALLS IF NEEDED. IGNORANCE ON THE PART OF THE CONTRACTOR WILL IN NO WAY RELIEVE HIM OF THE OBLIGATIONS AND RESPONSIBILITIES ASSUMED UNDER THIS CONTRACT. 2. GENERAL CONTRACTOR SHOULD MARK ALL SMOKE WALLS / FIRE WALLS ABOVE THE CEILING WITH PAINT TO READ ACCORDING TO THE WALL RATING AS SUCH: LETTERS MUST BE 1 1/2' FOR ONE HOUR WALLS AND 3' FOR TWO HOUR AND SMOKE WALLS AS FOLLOWS: ,J SMOKE / FIRE WALL (PROTECT ALL PENETRATIONS) 1 1/2' (TYPICAL) 3` TWO HOUR FIRE WALL (PROTECT ALL PENETRATIONS) II ONE HOUR CORRIDOR WALL (PROTECT ALL PENETRATIONS) ONE HOUR SMOKE PARTITION (PROTECT ALL PENETRATIONS) 3. PROVIDE 2' WIDE PAINTED RED LINE AT ALL STORAGE ROOMS, LOCATED IV BELOW BOTTOM OF SPRINKLER HEAD /CEILINGS, WITH 2' HIGH RED LETTERS TO READ 'NO STORAGE ABOVE RED LINE'. 4. PROVIDE PRESSURE TREATED FIRE - RETARDANT PAINTED WOOD SILL NAILER AT PERIMETER OF ALL ROOMS WITH WOOD BASE (SEE FINISH SCHEDULES) 5. ALL PARTITIONS SHALL BE 4' NOMINAL DIMENSION UNLESS OTHERWISE NOTED ON PLANS. 6. INTERIOR WALLS, PERMANENT PARTITIONS (RATED OR NOT) AND TEMPORARY PARTITIONS SHOULD SUPPORT A MINIMUM OF (5) POUNDS PER SQUARE FOOT APPLIED PERPENDICULAR TO THE WALL. 1. PROVIDE BACKING SUPPORT AT ALL PARTITIONS WHERE EQUIPMENT 15 INDICATED TO BE MOUNTED. 8. INSTALL METAL STUDS AT 16' O.G. WITH GYPSUM WALLBOARD HUNG VERTICALLY. S. GENERAL CONTRACTOR TO VERIFY ANY EXISTING PARTITIONS WITH NEW WALL TYPE DESIGNATIONS AND UP -GRADE AS REQUIRED TO REFLECT NOTED WALL TYPES. 10. SUPPORT OF SOFFITS FROM RATED PARTITION 16 APPROVED, ONLY IF THEY ARE ATTACHED DIRECTLY TO METAL STUDS AND /OR STRUCTURAL BACKING ONLY. ATTACHMENT TO GYP. WALLBOARD IS NOT ALLOWED. H. ALL EXISTING/NEW EXTERIOR MASONRY WALLS TO HAVE SCHEDULED FINISH ON 5/8' TYPE 'X' GYPSUM WALLBOARD ON 1 -5/8' METAL STUDS AT 16' O.C. OVER RIGID INSULATION BOARD (TYPICAL AT ROOM SIDE OF ALL FINISHED ROOMS ONLY). 12. ALL EXTERIOR MASONRY WALLS TO HAVE ONLY RIGID INSULATION AT ALL UNFINISHED ROOM SIDES. 13. PROVIDE CONTINUOUS (UNINTERRUPTED BY FURRING) R -45 (MIN.) RIGID INSULATION BOARD AT ALL EXTERIOR BLOCK/CONCRETE WALLS FACING AIR CONDITIONED SPACES. INSTALL FROM FINISH SLAB TO UNDERSIDE OF STRUCTURAL DECK. GYPSUM WALLBOARD TO CONCEAL INSULATION TO UNDERSIDE OF FINISHED STRUCTURAL DECK. 14. ALL DIMENSIONS SHOWN ON FLOOR PLANS ARE EITHER ROUGH (STUD TO STUD) OR MASONRY TO MASONRY OR MASONRY TO STUD) TYPICAL U.ON 15. IT IS THE INTENT FOR THE RATED BARRIER TO BE BUILT FIRST IN COMPLIANCE WITH THE UL. NO. AS QUOTEI ALL OTHER PARTITIONS ABUTTING RATED PARTITION SHALL NOT BE CONSTRUCTED UNTIL AFTER THE RATED PARTITION IS 100% COMPLETED. 16. IT IS REQUIRED THAT AFTER THE METAL STUD FRAMING IS COMPLETED ON A RATED PARTITION THAT THE COMPANY PROVIDING THE SYSTEM INSPECTS AND CERTIFIES IN WRITING THAT THE FRAMING HAS BEEN PERFORMED IN COMPLIANCE WITH THEIR REQUIREMENTS AND U.L. LABEL. SAME CERTIFICATION SHALL BE PROVIDED FOR GYPSUM WALLBOARD INSTALLATION, SCREWING AND TAPING. CONTRACTOR IS RESPONSIBLE FOR PLACING ELECTRICAL, MEDICAL GAS AND OTHER OUTLETS AND BOXES IN SUCH A FASHION AS TO NOT VIOLATE INTEGRITY OR STC RATING OF PARTITION. 11. ALL EXISTING MASONRY WALLS OR CONCRETE COLUMNS IN AREAS AFFECTED BY NEW RENOVATIONS SHALL RECEIVE SCHEDULED FINISH ON 5/6' TYPE 'X' GYPSUM WALLBOARD ON 118' METAL FURRING STRIPS AT 16' O.G. (TYPICAL UNLESS OTHERWISE NOTED ON PLANS) 18. BLOCK UP ALL PENETRATIONS THROUGH EXISTING EXTERIOR WALLS DUE TO THE REMOVAL OF EXISTING EQUIPMENT WITH RINKER TYPE T -18 OR T -IIA, RE- STUCCO EXTERIOR FACE AND PAINT TO MATCH EXISTING ADJACENT. (SEE MECHANICAL DRAWINGS) 51"f0KE P,RT I T I ON QU I1INTS: A SMOKE PARTITIONS SHALL BE CONTINUOUS FROM EXTERIOR WALL TO EXTERIOR WALL. AT POINTS OF INTERSECTION WITH OTHER PARTITIONS, THE INTEGRITY OF THE SMOKE WALL MUST BE MAINTAINED AND THE INTERSECTING PARTITIONS BUTTED TO IT. THE SMOKE PARTITION IS ALSO TO BE CONTINUOUS FROM FLOOR SLAB TO UNDERSIDE OF STRUCTURE (SLAB) ABOVE. B. IN SMOKE AND CORRIDOR PARTITIONS, ALL PENETRATIONS, INCLUDING CONDUITS, A/C DUCTS ETC., MUST BE SEALED TO MAINTAIN THE FIRE RATING INTEGRITY AS REQUIRED BY A.H.C.A. AND ALL GOVERNING AUTHORITIES. C. ALL DUCT PENETRATIONS OF SMOKE PARTITIONS AND FIRE RATED PARTITIONS MUST BE DAMPERED ACCORDING TO THE SPECIFIC FIRE RATING REQUIRED: SMOKE PARTITIONS - COMBINATION SDJF.D. FIRE PARTITIONS -FIRE DAMPER HORIZONTAL EXIT - COMBINATION SD1FD. CORRIDOR WALL -SMOKE DAMPER FLOOR ASSEMBLY OR VERTICAL SHAFT - COMBINATION 5.D_/F.D. HAZARDOUS ROOMS - COMBINATION SDJFD. D. ACCESS DOORS SHALL BE PROVIDED (FIRE RATED WHERE REQUIRED) AND LOCATED IN THE INACCESSIBLE AREAS ADJACENT TO SMOKE AND FIRE PARTITIONS TO ALLOW ALL PARTS OF PARTITIONS TO BE V15UALLY INSPECTED, MAXIMUM SPACING OF PANELS SHALL BE 30'. E. ALL PIPES, CONDUITS AND DUCTS AT ALL SMOKE/FIRE WALL PENETRATIONS SHALL BE DONE AT 90 DEGREES ON BOTH SIDES. F. ANY RECESSED ITEM IN THE SMOKE PARTITION OVER 4'x4' MUST BE ENCASED IN A FIVE SIDED 5/8' TYPE 'X' GYPSUM WALLBOARD BOX. CONTRACTOR IS RESPONSIBLE FOR PROVIDING ADEQUATE BACK BOXING FOR ITEMS (EXCEEDING 16 SQ. IhL) RECESSED IN A FIRE PARTITION. BACK BOXING SHALL BE OF SUCH CONSTRUCTION AS TO COMPLY WITH FIRE RATING REQUIREMENTS FOR THE PARTITION. THESE ITEMS INCLUDE, BUT ARE NOT LIMITED TO: ELECTRICAL JUNCTION BOXES MED. GAS OUTLETS, VALVE BOXES AND ALARM BOXES FIRE EXTINGUISHER CABINETS WATER COOLERS FIRE HOSE CABINETS TELEPHONES FILM ILLUMINATORS ACCESSORIES PARTITION t Y P E S ONE- OUR WA L CONSTRUCTION C=A P I L- E= N C). Wf= 12 0) sa UL DE5 U465 BOTTOM OF FINISH STRUCTURAL DECK SEALANT(BOTH SIDES) CEILING BACK -UP STUD SCHEDULED _ — CEILING * SCHEDULED FINISH ON ONE LAYER 5/8' TYPE 'X' GYPSUM WALLBOARD EACH SIDE OF METAL STUDS <S>3 5/8', 6' OR 8' METAL STUDS AT 16' O.C. PROVIDE METAL STUDS AT WALLBOARD HORIZONTAL JOINTS ACTUAL RIM. 4 1/8' FOR 3 5/6' STUD ACTUAL DIM. 1 1/4' FOR 6' STUD ACTUAL DIM. S 1/4' FOR 8' STUD SOUND ATTENUATION BLANKET TO UNDERSIDE OF STRUCTURE SEALANT (BOTH SIDES) FINISH SLAB 5ECTION / \ TYPICAL ONE -HOUR FIRE -RATED PARTITION WITH SOUND ATTENUATION BLANKET DENSSHIELD WALLBOARD INSTEAD OF TYPE 'X' 0 WET LOCATIONS ONE HOUR CONSTRUCTION NOTE ONE LAYER 5/8' TYPE 'X' GYPSUM WALLBOARD APPLIED AT RIGHT ANCsLES OR PARALLEL TO EACH SIDE OF 3 5/8' MIN. METAL STUDS o 16' O.C. W/ I' TYPE S DRYWALL SCREUJS 8' O.C. TO VERTICAL EDGES AND 12' O.C. TO TOP AND BOTTOM RUNNERS AND INTERMEDIATE STUDS. STAGGER ALL VERTICAL AND HORIZONTAL JOINTS 16' OD. EACH SIDE AND OPPOSITE SIDES. (NL.BJ (U.L. PILE: NO_ FM L14ro5.) NOTE: CONTRACTOR SHALL SUPERVISE AND INSPECT CONSTRUCTION OF ALL WALLS TO VERIFY THAT CONSTRUCTION IS PERFORMED IN ACCORDANCE TO SPECIFICATIONS ABOVE. ANY VARIATIONS SHALL IBE BROUGHT TO THE .4RGI- 11TEGT9 .4TTENTION. CHASE FAfi�T I T I ON — PARTITION TYPE 4A BOTTOM OF FINISH STRUCTURAL DECK ONE SIDE OF ASSEMBLY ONLY —SEAL TIGHT (TOP 4 BOTTOM) CEILING BACK -UP STUD I ;' AT SMOKE TIGHT PARTITION SCHEDULED CEILING SCHEDULED FINISH ON ONE LAYER OF 5/S' TYPE 'X' GYPSUM WALLBOARD OVER ONE LAYER OF METAL STUDS I ' 5/8' DENSHIELD 3 5/8' METAL STUDS AT 16' O.G. W ACTUAL DIM. 4 -118' FOR 3 -5/8' METAL STUDS ' ? VAR) S (SEEI PL ) SOUND ATTENUATION BLANKET TWO HOUR FIRE WALL m ' TO UNDERSIDE OF STRUCTURE 'r TWO HOUR SHAFT WALL WALLBOARD TO DECK CERAMIC TILE 0 SEALANT (BOTH SIDES) I_ NON RATED WALL = cn -- 311/2' SOUND BATT. ATTENUATION TO w ACTUAL HEIGHT) 4 NON -RATED PARTITION SECTION WITH SOUND ATTENUATION BLANKET Qtil 1= GWB STOPS • 6' ABOVE CEILING. BLANKETS IN PLACE WITH 4' WIDE STRIPS OF 5/8' GYPSUM BOARD SCHEDULE FINISH ON INSTALLED HORIZONTALLY ® 24' O.C. (OR AS D NON -RATED PARTITION WITH SOUND ATTENUATION BLANKET ALLOWED BETWEEN PLUMBING CARRIERS OR OTHER CONSTRUCTION OBSTACLES). X WALLBOARD ON METAL STUDS ® f6' ON CENTER 4 ONE LAYER 2A 5ECTION / \ TYPICAL ONE -HOUR FIRE -RATED PARTITION WITH SOUND ATTENUATION BLANKET DENSSHIELD WALLBOARD INSTEAD OF TYPE 'X' 0 WET LOCATIONS ONE HOUR CONSTRUCTION NOTE ONE LAYER 5/8' TYPE 'X' GYPSUM WALLBOARD APPLIED AT RIGHT ANCsLES OR PARALLEL TO EACH SIDE OF 3 5/8' MIN. METAL STUDS o 16' O.C. W/ I' TYPE S DRYWALL SCREUJS 8' O.C. TO VERTICAL EDGES AND 12' O.C. TO TOP AND BOTTOM RUNNERS AND INTERMEDIATE STUDS. STAGGER ALL VERTICAL AND HORIZONTAL JOINTS 16' OD. EACH SIDE AND OPPOSITE SIDES. (NL.BJ (U.L. PILE: NO_ FM L14ro5.) NOTE: CONTRACTOR SHALL SUPERVISE AND INSPECT CONSTRUCTION OF ALL WALLS TO VERIFY THAT CONSTRUCTION IS PERFORMED IN ACCORDANCE TO SPECIFICATIONS ABOVE. ANY VARIATIONS SHALL IBE BROUGHT TO THE .4RGI- 11TEGT9 .4TTENTION. CHASE FAfi�T I T I ON — PARTITION TYPE 4A BOTTOM OF FINISH STRUCTURAL DECK ONE SIDE OF ASSEMBLY ONLY —SEAL TIGHT (TOP 4 BOTTOM) CEILING BACK -UP STUD I ;' AT SMOKE TIGHT PARTITION SCHEDULED CEILING SCHEDULED FINISH ON ONE LAYER OF 5/S' TYPE 'X' GYPSUM WALLBOARD OVER ONE LAYER OF METAL STUDS I ' 5/8' DENSHIELD 3 5/8' METAL STUDS AT 16' O.G. W ACTUAL DIM. 4 -118' FOR 3 -5/8' METAL STUDS ' ? VAR) S (SEEI PL ) WALL PRIORITY LEGEND LOWEST PRIORITY TWO HOUR FIRE AND SMOKE WALL SOUND ATTENUATION BLANKET TWO HOUR FIRE WALL SEAL TIGHT (TOP 4 BOTTOM) ' TO UNDERSIDE OF STRUCTURE PRORIT7 2 TWO HOUR SHAFT WALL WALLBOARD TO DECK CERAMIC TILE PRIORITY 3 SEALANT (BOTH SIDES) (SEE ROOM FINISH NON RATED WALL ' SCHEDULE FOR -- 311/2' SOUND BATT. ATTENUATION TO FINISH SLAB ACTUAL HEIGHT) 4 NON -RATED PARTITION SECTION WITH SOUND ATTENUATION BLANKET NOTE: HOLD ATTENUATION GWB STOPS • 6' ABOVE CEILING. BLANKETS IN PLACE WITH 4' WIDE STRIPS OF 5/8' GYPSUM BOARD SCHEDULE FINISH ON INSTALLED HORIZONTALLY ® 24' O.C. (OR AS 4A NON -RATED PARTITION WITH SOUND ATTENUATION BLANKET ALLOWED BETWEEN PLUMBING CARRIERS OR OTHER CONSTRUCTION OBSTACLES). 2 1/2' STUDS W/ DENSHIELD ON ONE SIDE WALLBOARD ON METAL STUDS ® f6' ON CENTER WALL PRIORITY LEGEND LOWEST PRIORITY TWO HOUR FIRE AND SMOKE WALL PRIORITY I HWEST TWO HOUR FIRE WALL SEAL TIGHT (TOP 4 BOTTOM) PRORIT7 2 TWO HOUR SHAFT WALL WALLBOARD TO DECK ONE HOUR FIRE AND SMOKE WALL PRIORITY 3 ONE HOUR FIRE WALL FRIORJTY 4 NON RATED WALL PRIORITY 5 LOWEST NOTE -- 311/2' SOUND BATT. ATTENUATION TO l SCHEDULE CCNSTFWTION OF WALLS ACCORDWi TO PRIORITY. 2. ALL PRIORITY I THRJ 4 WALLS SHOULD BE FRAMED WITH ONE SIDE DRYWALLED AT THE 40% CONSTRUCTION SURVEY. 3. BOTH SIDES OF PRIORITY I THRU 4 WALLS SHALL BE SEALED AND STENCILED AT THE W. CONSTRICTION SURVEY. OF PARTITION. 2B NON—RATED FA ?T I T I ON DRYWALL BOTH SIDES AND FRAME TO UNDERSIDE OF STRUCTURE FOR SECURITY REASONS - NOT RATED CEILING= BACK -UP STUD . SEAL TIGHT (TOP 4 BOTTOM) WALLBOARD TO DECK e AT SMOKE TIGHT PARTITION __ SCHEDULED ___— - - -_ - - -- - -- -- 311/2' SOUND BATT. ATTENUATION TO CEILING EXTEND 24' ABO ON BOTH SIDES OF PARTITION. 2B SCHEDULE FINISH ON SCHEDULED 5/8' TYPE 'X' CEILING WALLBOARD ON METAL STUDS ® f6' ON CENTER ONE LAYER 2A w 5/8' DUROCK PROVIDE METAL STUDS w AT WALLBOARD HORIZONTAL JOINTS a w LL ACTUAL DIM. 4 1/8' FOR 3 5/8' STUD ACTUAL DIM. 1 1/4' FOR 6' STUD ACTUAL DIM. S 1/4' FOR 6' STUD u� SOUND ATTENUATION BLANKET TO UNDERSIDE OF STRUCTURE 20 GAGE STEEL TRACK CERAMIC TILE (TOP 4 BOTTOM TYPICAL) (PER FINISH SCHEDULE) FINISH CONCRETE SLAB SEALANT (BOTH SIDES) —14 3116' TAPCONS s 16' O.C. (r' MIN. EMBEDMENT) TYPICAL SECTION 2A DENSHIELD WALLBOARD INSTEAD OF TYPE 'X' 9 WET LOCATIONS 2B TYPICAL NON -RATED PARTITION WITH SOUND ATTENUATION BLANKET PARTITION TYPES NOTES; 1.- ALL METAL STUD PARTITIONS TO BEAR CABINETS AND /OR SUPPORT WALL HUNG PLUMBING FIXTURES SHALL BE 20 GAGE (MIN.) PER FBC 2510.5.1.1 - INTERIOR MASON FINISH BOTTOM OF FINISH STRUCTURAL DECK SCHEDULED CEILING SCHEDULE FINISH ON ONE LAYER 5/8' DENSAMOR PLUS GYPSUM WALLBOARD 1/8' METAL FURRING * 16' ON CENTER SCHEDULED BASE --1 FINISH SLAB SECTION 5A DENSHIELD WALLBOARD INSTEAD OF TYPE 'X' s WET LOCATIONS 5B USE 6' STUDS INSTEAD OF FURRING CHANNELS. BOTTOM OF FINISH STRUCTURAL DECK SEALANT 3 5/8' METAL TRACK FACE OF NEW OR EXISTING CONCRETE BLOCK WALL OR CONCRETE 2 1/2' METAL PROVIDE STUDS 0 16' O.G. ASSEMBLY AT BOTH SIDES NEW I' GYPSUM WALLBOARD SEALANT EXISTING FURRING �_ EXISTING CEILING STRIPS EXISTING GYPSUM WALLBOARD EXISTING 4' CONCRETE MASONRY UNIT • .- .•- . ilE�i31i -•• .� DETAIL IS TYPICAL AT CORRIDOR WALLS REQUIRED TO BE UPGRADED TO 'SMOKE TIGHT' AND AT CLEAN AND SOILED UTILITY WALLS REQUIRED TO BE UPGRADED TO I HOUR FIRE, PROVIDE FIRE DAMPERS AT WALLS REQUIRED TO BE I HOUR FIRE RATED FAN WALL UPGRADE DETAIL N.T.S. EXTERIOR MASONRY WAL BOTTOM OF FINISH STRUCTURAL DECK EXISTING OR NEW 8' CONCRETE MASONRY UNIT OR CONCRETE STUCCO FINISH (SEE BUILDING ELEVATION'S) 3/4' INSULATION 31' METAL STUDS 16' O.C. SEE NOTE BELOW 5/8' TYPE X GYPSUM WALLBOARD BASE (SEE FINISH SCHEDULED) SEALANT FINISH SCHEDULED SECTION AT ALL EXTERIOR WALLS PROVIDE 3/4' THERMAX INSULATION FROM THE FLOOR TO THE SLAB ABOVE ANCHORED TO THE MASONRY AS PER MANUFACTURER'SRECOMMENDATION THIS PARTITION TYPE IS TYPICAL AT ALL EXTERIOR WALLS. ON` - HOUR SHAFT PA" I T I ON CAULK TOP OF SLAB — FINISHED SIDE \_/ HORIZONTAL SECTION FLOOR 4 CEILING 'J' SHAPED GALV. STEEL RUNNERS 2 LAYERS OF 1 /2 ' GYPSUM WALLBOARD 02 'C -H' SHAPED GALV. STEEL STUD m 12' O.C. BATTS AND BLANKETS (OPTIONAL) ( 3� V GYPSUM WALLBOARD - INTERIOR SHAFT LINER i�77 e Z wo A. o! w V) 0 < < (� x 1� ISM M x� t �S w z u► g • pm" V o a `o *~ d r E x c� G 0 �4mO If I i.n o� W < a zA o_z 'Q. O� W a p z PERMIT SET DRAW% G.C. C HECRM L.EM DATFj 02 -15 -12 �G1EEt4:" °AS SHOWN Sheet No. A -10 15 jo>a �' 201138 . 'O f!/ Sheet No. A -10 15 jo>a �' 201138