Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
12-242-001
i 1" HOOD A -1 8" X 9" :1:1WIDUCT NOZZLE E3611 FUSIBLE LINK NEW HOOD A -1 f� I E� FUSIBLE LINK 0 00 0 ❑- 0 0 0 0 0 0 - e 0 II 1 ❑ 000000 CONY. OVEN KETTLE 8" X 9" 8" X 9" IW DUCT NOZZLE HOOD A -2 1 1W DUCT NOZZLE 36E� 36® 36® 360' FUSIBLE LINK FUSIBLE LINK FUSIBLE LINK FUSIBLE LINK IN PLENUM NOZZLE NEW HOOD A -2 #3N I #3N I #3N I #3N , 3 m1 E 8" X 9" 8" X 9" 1W DUCT NOZZLE HOOD A -3 1N! DUCT NOZZLE ® 36® FUSIBLE UNK FUSIBLE LINK PLENUM NOZZLE NEW HOOD A -3 0 0 eo uo C_ _.__ -j2[] 0 0 0 0 0 0 0 0 r 00 e O D �.II ❑ 9= d:= 0 --T L u u KETTLE TILT SKILLET CONV. OVEN CONV. OVEN 36" X 32" -1, ., APPLIANCE LAYOUT SCALE: AS SHOWN // // 0 0 0 0 0 0 0 0 oe O ❑ 0 0 oe ❑ 0 000aaaa // II all❑ 0 0 00 O D 0000000 a 0 D II ❑ 0000000 8" X 9" 8" X 9" 1W DUCT NOZZLE HOOD A -3 1N! DUCT NOZZLE ® 36® FUSIBLE UNK FUSIBLE LINK PLENUM NOZZLE NEW HOOD A -3 0 0 eo uo C_ _.__ -j2[] 0 0 0 0 0 0 0 0 r 00 e O D �.II ❑ 9= d:= 0 --T L u u KETTLE TILT SKILLET CONV. OVEN CONV. OVEN 36" X 32" -1, ., APPLIANCE LAYOUT SCALE: AS SHOWN I r CONY. OVEN 8" X 9" 8" X 9" g• X g" FTw]DUCT NOZZLE HOOD A -4 IW DUCT NOZZLE F1WDUCT NOZZLE 360, 38® 360, 36® FUSIBLE LINK FUSIBLE LINK FUSIBLE LINK FUSIBLE LINK IN IN PLENUM PLENUM NOZZLE NOZZLE 260 1 260 000 0C) C=D 0 0 0 L - L 4 BURNER RNGE 18 "X11.75 " &1Fx14.25" FRONT RAR NEW HOOD A -4 IN 11N 11N IN ■I I■ ■I I■ 1 11 // // 0 0 0 0 0 0 0 0 oe O ❑ ❑ 0 // II all❑ 0 0 00 O D 0000000 I r CONY. OVEN 8" X 9" 8" X 9" g• X g" FTw]DUCT NOZZLE HOOD A -4 IW DUCT NOZZLE F1WDUCT NOZZLE 360, 38® 360, 36® FUSIBLE LINK FUSIBLE LINK FUSIBLE LINK FUSIBLE LINK IN IN PLENUM PLENUM NOZZLE NOZZLE 260 1 260 000 0C) C=D 0 0 0 L - L 4 BURNER RNGE 18 "X11.75 " &1Fx14.25" FRONT RAR NEW HOOD A -4 IN 11N 11N IN ■I I■ ■I I■ 1 11 GAS RADIANT CHAR - BROILER 5211 X 2411 HOOD LAYOUT EXISTING SCALE: AS SHOWN WALL OD NEW HOOD NEW HOOD NEW HOOD NEW HOOD HOOD A -2 HOOD A-3 HOOD A-4 HOOD A -1 CHEMICAL INLET TANK 1 -6N -8F C CHEMICAL INLET XF TANK 2- 4N -12F -� - SE LINK O O � INLET © CHEMICAL INLET TANK 3- 12N -12F —91 361 z •09 Sol, FLOOR LAYOUT SCALE: 3/16" = 1' IVCVV nVVU HOOD A -2 FIRE SYSTEM PULL STATION r TO NC GRIDDLE HOOD SIDE VIEW /2r EMT TO 3/g' PIPE ANSUL PULL STATION TO NOZZLE 7 EMT T❑ FUSIBLE LINK DETECTORS PIPE I NOZZLE' EMT TO OFF GAS TVALVE NOZZLE PLACEMENT REQUIREMENTS M N1101 FLOW No���' NMI AREA -384 sq. in. ---- - _ „_ _ _ DUCT - LENGTH - UNLIMITED 8 419336 1W 8 - - - - - -- PERIMETER- 100in GAS RADIANT CHAR - BROILER 5211 X 2411 HOOD LAYOUT EXISTING SCALE: AS SHOWN WALL OD NEW HOOD NEW HOOD NEW HOOD NEW HOOD HOOD A -2 HOOD A-3 HOOD A-4 HOOD A -1 CHEMICAL INLET TANK 1 -6N -8F C CHEMICAL INLET XF TANK 2- 4N -12F -� - SE LINK O O � INLET © CHEMICAL INLET TANK 3- 12N -12F —91 361 z •09 Sol, FLOOR LAYOUT SCALE: 3/16" = 1' IVCVV nVVU HOOD A -2 FIRE SYSTEM PULL STATION r TO NC GRIDDLE HOOD SIDE VIEW /2r EMT TO 3/g' PIPE ANSUL PULL STATION TO NOZZLE 7 EMT T❑ FUSIBLE LINK DETECTORS PIPE I NOZZLE' EMT TO OFF GAS TVALVE NOZZLE PLACEMENT REQUIREMENTS HAZARD MAXIMUM HAZARD NOZZLE NOZZLE NOZZLE TIP # OF NOZLLE DIMENSIONS QTY. PART No. STAMPING- FLOWS HEIGHT FLOW No���' PLENUM LONGEST SIDE -32in. 4 419335 1N = = -4 - - - - =- AREA -384 sq. in. ---- - _ „_ _ _ DUCT - LENGTH - UNLIMITED 8 419336 1W 8 - - - - - -- PERIMETER- 100in DIAMETER -31iin RANGE LONGEST SIDE 32in. 2 419341 260 4 30 -40in. AREA 768sq in. 4 ° TILT SKILLET 27 3 /4in. X 324in. 4 419338 3N 12 25 -35in. GRIDDLE LONGEST SIDE 36in. 1 419335 1 N 1 35: 40in. AREA 1080sq in. r GRIDDLE SIDE 36in. 3 419335 1N 3 15 -40in. AREA 864sq in. DISTRIBUTION PIPING REQUIREMENTS DISTRIBUTION PIPING REQUIREMENTS - 3.OGAL. AGENT TANK (EA.) I REQUIREMENTS SUPPLY /LINE DUCT PLENUM APPLIANCE BRANCH LINE BRANCH LINE BRANCH LINE PIPING -SIZE in. in. in. 1)I in.; MAXIMUM LENGTH 40 ft. 8 ft. 4 ft. 12 ft. MAXIMUM RISE. 6 ft. 4 ft. 2 ft. 2 ft, MAXIMUM 90' 9 4 4 6 ELBOWS MAXIMUM TEES 1 2 2 4 1� MAXIM M BLOW 11 4 2 4 NUMBERS ” IM, x GENERAL NOTES: 1.- SYSTEM SHALL BE PROVIDED WITH A LOCAL INDICATOR /ALARM AND WITH A RELAY TO SHUT DOWN THE SUPPLY FAN (IF APPLICABLE) WHEN THE SYSTEM IS ACTIVATED, TURN ON EXHAUST FAN AND •SHUT OFF ALL ELECTRIC UNDER THE HOOD. (BY OTHERS) 2.- KITCH =N FIRE SUPPRESSION SYSTEM WILL SHUT OFF THE GAS VALVE TO BE INSTALLED IN AN ACCESSIBLE PLACE BELOW THE CEILING. 3.- PIPE SHALL BE $' SCHEDULE 40 BLACK IRON. 4.- ONE 'K" CLASS FIRE EXTINGUISHER WILL BE LOCATED WITHIN 30 FEET OF THE COOKING HOOD AS PER THE FLORIDA FIRE PREVENTION CODE. 5.- A BALLOON TEST TO BE PERFORMED TO ENSURE THAT THE SYSTEM FUNCTIONS PROPERLY. NITROGEN WILL BE BLOWN THROUGH THE LINES TO VERIFY PIPING IS UNOBSTRUCTED. 6.- THE NSTALLATION COMPLIES WITH NFPA 17A AND NFPA 96. 7.- ONLY MANUFACTURES LISTED COMPONENTS ARE USED FOR AND WITH THIS SYSTEM. 8.- IN AREA OF PENETRATION, CONDUIT AND PIPING WILL HAVE GREASE TIGHT FITTINGS. 9.- THE SYSTEM IS TO BE REVIEWED AND TESTED BY THE LOCAL (AHJ). I.E. FIRE MARSHALL. THIS HOOD IS PROTECTED BY THE ANSUL R -102 FIRE' SUPPRESSION SYSTEM WITH THREE 3.OGAL. AGENT TANKS. THE TOTAL NUMBER OF FLOW POINTS OCCUPIED BY THE SYSTEM IS 32 FLOW POINTS OF THE 33 AVAILABLE FLOWS. ?- - - T � !e • �' l� �v �'.':. 127 . SEQUENCE OF EVENTS: �M DAY MODE: THE FOLLOWING WILL OCCUR UPON SYSTEM ACTUATION. A) THE MAKEUP AIR FAN (IF ANY) WILL TURN OFF. B) THE EXHAUST FAN WILL CONTINUE TO OPERATE TO EVACUATE SMOKE. C) ALL ;ELECTRICAL UNDER THE HOOD WILL SHUT OFF. D) THE BUILDING FIRE ALARM SYSTEM (IF ANY) WILL BE SIGNALLED. �. E) THE GAS VALVE WILL CLOSE. NIGHT MODE: I THE FOLLOWING WILL OCCUR UPON SYSTEM ACTUATION. I A) THE MAKEUP AIR FAN (IF ANY) WILL STAY OFF. B) THE-EXHAUST FAN WILL TURN ON TO EVACUATE SMOKE. j C) ALL ELECTRICAL UNDER THE HOOD WILL SHUT OFF. D) THE BUILDING FIRE ALARM SYSTEM (IF ANY) WILL BE SIGNALLED. E) THE' ',GAS .VALVE WILL CLOSE. NOTE: ALL ELECTRICAL RV —Aft T BE ERFORMED BY OTHERS. e iV YF,E L9 FILE NAME: SOUTH MIAMI HOSPITAL ANSUL R -102 ANSUL R -102 REGULATED AUT ❑MAN 2 -3,0 GAL, CYLINDER RELEASE ASSEMBLY Triangle Fire, Inc. ENCLOSURE (MECHANICAL) 7720 N.W. 53rd Street, Miami, FL 33166 TYPICAL INSTALLATION (305) 592 -3011, Fax: (305) 592 -5254 ]SUL R -102 (UL300) THREE 3,0 GAL, AGENT SOUTH MIAMI HOSPITAL TANKS SYSTEM 6200 SW 73 STREET SOUTH MIAMI, FL 33143 ENGINEERS NAME: MICHAEL C. GUERRERO DISCIPLINE: MECHANICAL ENGINEER SCALE AS SHOWN DRAWN Todd Johnson TELEPHONE: (305) 262 -3944 LIC. FL. # 135 r� `F DATE 1/11/2012 REVISED ADDRESS: 780 TAMIAMI CANAL RD. :�iai' A .' S�� �`Efij�1SUL R -102 FIRE SUPPRESSION SYSTEM SHEET MIAMI, FL. 33144. '~`w= I_� THREE 3.0 GALLON AGENT TANKS. OF 1 SHEETS I I i I jI r ' i i i I` a I i i