Loading...
12-192-003STAINLESS STEEL SCUPPER BOX AND 4" RAIN WATER LEADER BEYOND PRIME AND SET IN ROOF CEMENT OVER THE FIELD PLIES AND INSTALL FLASHING AND STRIPPING PLIES OVER NAILED FLANGES MIN. 24 GA. PREFABRICATED SCUPPER FLASHING TO CONFORM TO DIM. OF OPENINGS AND SET IN ROOF CEMENT ENERGYGUARD CANT STRIP —SET IN BITUMEN RUBEROID BASE FLASHING HW PLUS FR. PLY SHEETS 1/8" DENS DECK ENERGYGUARD ROOF INSULATION DECK Bi- Scupper Thru Roof 3 Flashing Detail NTS A -2 NOTE: 1. WALL FLASHING NOT DRAWN FOR CLARITY. SEE DETAIL 1/A -2 FOR WALL FLASHING WITH SURFACE MOUNT DETAIL. I i i SEE 1/A -2 FOR FLASHING DETAIL DETAIL I SEE 2/A -2 FOR SCUPPER DETAIL 22 GAUGE 8 "D X 12"Y' X 14 "D STAINLESS STEEL CONDUCTOR HD 22 GAUGE STAINLESS STEEL 4 "0 DOWNSPOU 14 GAUGE STAINLESS STEEL DOWNSPOUT HAI EXISTING STRUCTUF EXISTING STRUCTU F 8' MW-M 6 Downspout Detail 1 1/2" A-2 EXISTING STUCCO SEALANT 22 GAUGE 8 "D X 12"W X 14 "D STAINLESS STEEL CONDUCTOR HEAD 22 GAUGE STAINLESS STEEL 4 "0 DOWNSPOUT 14 GAUGE STAINLESS STEEL DOWNSPOUT HANGER 14 GAUGE STAINLESS STEEL DOWNSPOUT SHOE CONCRETE SPLASH BLOCK 4 SIDED BOX SIZED — TO SCUPPER OPENING, SLOPED FOR DRAINAGE FASTEN TO DECK OR NAILERS AND TO WALL USING APPROPRIATE FASTENERS AT 8" O.C. MAXIMUM PRIME AND SET IN ROOF CEMENT OVER THE FIELD PLIES AND INSTALL FLASHING AND STRIPPING PLIES OVER NAILED FLANGES MIN. 24 GA. PREFABRICATED SCUPPER FLASHING TO CONFORM TO DIM. OF OPENINGS AND SET IN ROOF CEMENT ENERGYGUARD CANT STRIP —SET IN BITUMEN RUBEROID BASE FLASHING HW PLUS FR. PLY SHEETS 1/8" DENS DECK ENERGYGUARD ROOF INSULATION DECK MIN. 4" FLANGE SURROUNDING 0 SCUPPER OPENING 0 — ALL JOINTS �Q SOLDERED SOLDERED BI —LEVEL FLANGE Bi- Scupper Flashing T Detail NTS SEE IMAGE #1, DETAIL 5/A -2 FOR SCUPPER NOTE: 1. BASE FLASHING ON ALL 15 AND 20 YEAR GUARANTEE SYSTEMS MUST HAVE A BASE PLY. REFER TO FLASHING MEMBRANE APPLICATION AND FLASHING SPECIFICATION PLATES. 2. SEALANT AT TOP OF SURFACE MOUNTED COUNTER FLASHING IS A MAINTENCE ITEM AND MUST BE MAINTAINED THROUGHOUT THE LIFE OF THE ROOF TO ENSURE A WATER TIGHT SEAL 3. WALL FLASHING NOT DRAWN FOR CLARITY. SEE DETAIL 1/A -2 FOR WALL FLASHING WITH SURFACE MOUNT DETAIL. STAINLESS STEEL BI —LEVEL SCUPPER MIN 4" FLANGE SURROUNDING SCUPPER OPENING — ALL JOINTS SOLDERED" SOLDERED t' �►, 4. >,, ;. BI —LEVEL FLANGE t pip, x P 9 _ mti 5 Image #01 nts A -2 NOTE: 1. MASONRY WALLS TO BE PRIMED PRIOR TO FLASHING. 2. BASE FLASHINGS TURNED OVER EDGE A MINIMUM OF 1 1/2" (38mm) OR THICKNESS OF NAILER WHICHEVER IS GREATER. 3. BASE FLASHING ON ALL 15 AND 20 YEAR GUARANTEE SYSTEMS MUST HAVE A BASE PLY. REFER TO FLASHING MEMBRANE APPLICATION AND FLASHING SPECIFICATION PLATES. FEATHER AT EDGE FLEX AND FABRIC PLY 2 COURSES OF SURFACE SEAL ON TOP OF PARAPET TAPCONS APPROX. 3" O.C. STAGGERED METAL SET IN MASTIC WITH MOP APPLIED MEMBRANES —PRIME FLANGE BEFORE STRIPPING JOINT COVER 4" TO 6" WIDE —SET IN MASTIC —DO NOT USE MASTIC WITH TORCH APPLIED MEMBRANES NAIL AT 9" O.C. ENERGYGUARD CANT STRIP — SET IN BITUMEN RUBEROID/ GAFGLAS BASE FLASHING RUBEROID/ GAFGLAS MEMBRANE BASE/ PLY SHEET(S) ENERGYGUARD ROOF INSULATION VAPOR RETARDER AS SPECIFIED EXISTING CONCRETE DECK Low Wall 1 Flashing Detail NTS A -2 SPECIFICATION: I- 0- 3- 25/HGPFR (EC) ROOF SURFACE CAP SHEET PLY SHEET BASE SHEET TAPERED INSULATION ROOF DECK COAfPONENT TYPE REQUIRED ATTACHMENT RATE OFAPPLICATION DECK Concrete Per Code INSULATION EnergyGuardTM Polylso Roof One (1) layer OlyBond 500TM Adhesive '/4" to 1" ribbons spaced 12" o.c. Insulation Minimum 1.5" ASTM C 1289 ROOFBOARD ''/4" Dens Deck PrimeT14 Roof One (1) layer OlyBond 5001`M Adhesive '/4" to I" ribbons spaced 12" o.c. Board ASTM C 1177 PLYSHEET RUBEROIDV SBS Heat- Two (2) plies Heat Welded Fully Adhered We1dTM 25 L ASTM D6163 CAP SHEET RUBEROID® One (1) ply Heat Welded Fully Adhered SBS Heat- WeldTM Plus FR ASTM D6164 FLASHING RUBEROIDV SBS Heat- One (1) ply Heat Welded Fully Adhered 2N25f1 WeldTM 25 ■ ASTM D6163 L RUBEROIDID One (1) ply Ileat Welded Fully Adhered SBS Heat- WeIdTM Plus FR ASTM D6164 GUARANTEE WeatherStopperO Diamond Twenty (20) GUARANTEE FEE IS Pledge Guarantee years APPLICABLE 4 Roof Specification nts A -2 NOTE: 1. ROOF SPECIFICATIONS ARE BASED ON GAF'S MANUFACTURER SPECIFICATIONS. GC TO PROVIDE ROOFING AS SPECIFIED OR AN EQUAL APPROVED BY THE OWNER AND ARCHITECT. 2. NOA: 08- 1028.02, PAGE 9 OF 36 t ?Ii�1` -t `(t.- �UU1 I-i'1y11�11 BUILDING DEPT. STRUCTU - A SECTION L ORBES ARCHITECTS -architecture land planning retail design space planning - conitruclion management A56� ponce de Peon blvd. suite 100 coral gables, Florida 33146 tel: 305.446.0849 fax: 305.444.5557 florlda registration no. AA - F000104 a O O O O O O O O O O O O O O O , O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O a O a O O O • O • O •• • R, y� t'+. CL 1 S• 1f W40 A �ft John Roberts Forbes AR0009810 OWNERSHIP AND USE OF THE DOCUMENTS: THESE DRAWINGS, SCHEDULES, SPECInCATIONS AND EXPRESSED IDEAS AS INSTRUMENTS OF SERVICE ARE AND SHALL REMAIN THE PROPERTY OF FORBES ARCHITECTS WHETHER THE PROJECT FOR WHICH THEY ARE PREPARED IS EXECUTED OR NOT. THE OWNER AND /OR TENANT SHALL ONLY BE PERMITTED TO RETAIN COPIES OF THESE DRAWINGS, SCHEDULES, SPEonCATIOTS AND EXPRESSED IDEAS FOR INFORMATION AND REFERENCE. THE DRAWINGS, SCHEDULES. SPECIFICATIONS AND EXPRESSED IDEAS SHALL NOT BE USED BY THE OWNER AND /OR TENANT ON OTHER PROJECTS, FOR ADOIRONS TO THIS PROJECT OR FOR COMPLETION OF THE PROJECT BY OTHERS EXCEPT BY AGREEMENT IN WRITING AND WITH APPROPRIATE COMPENSAT19N TO FORBES ARCHITECTS COPYRIGHT C 2009, JOHN FORBES. INC., dba FORBES ARCHITECTS, ALL RIGHTS RESERVED. 4— O O r L ■ L CL4' 7k CL V/ O t0 C — v ■ CL > M m `- M M O = C n > c � E _° v ti G U G t0 c N • - Lu 0 O w O O ti > > °o V ♦ U) U) U) ti � U 4) � � EL 0 Date 01 -12 -12 Commission 11070 Revisions 0 01 -24 -12 ADDENDUM #1 Sheet A -2 r 2 Of 2