12-192-003STAINLESS STEEL SCUPPER BOX AND
4" RAIN WATER LEADER BEYOND
PRIME AND SET IN ROOF CEMENT
OVER THE FIELD PLIES AND
INSTALL FLASHING AND STRIPPING
PLIES OVER NAILED FLANGES
MIN. 24 GA. PREFABRICATED SCUPPER
FLASHING TO CONFORM TO DIM. OF
OPENINGS AND SET IN ROOF CEMENT
ENERGYGUARD CANT STRIP
—SET IN BITUMEN
RUBEROID BASE FLASHING
HW PLUS FR.
PLY SHEETS
1/8" DENS DECK
ENERGYGUARD ROOF INSULATION
DECK
Bi- Scupper Thru Roof
3 Flashing Detail NTS
A -2 NOTE:
1. WALL FLASHING NOT DRAWN FOR CLARITY. SEE DETAIL
1/A -2 FOR WALL FLASHING WITH SURFACE MOUNT DETAIL.
I
i
i
SEE 1/A -2 FOR
FLASHING DETAIL DETAIL I
SEE 2/A -2 FOR
SCUPPER DETAIL
22 GAUGE 8 "D X 12"Y'
X 14 "D STAINLESS
STEEL CONDUCTOR HD
22 GAUGE STAINLESS
STEEL 4 "0 DOWNSPOU
14 GAUGE STAINLESS
STEEL DOWNSPOUT HAI
EXISTING
STRUCTUF
EXISTING
STRUCTU F
8'
MW-M
6 Downspout Detail 1 1/2"
A-2
EXISTING STUCCO
SEALANT
22 GAUGE 8 "D X 12"W
X 14 "D STAINLESS
STEEL CONDUCTOR HEAD
22 GAUGE STAINLESS
STEEL 4 "0 DOWNSPOUT
14 GAUGE STAINLESS
STEEL DOWNSPOUT
HANGER
14 GAUGE STAINLESS
STEEL DOWNSPOUT SHOE
CONCRETE SPLASH BLOCK
4 SIDED BOX SIZED —
TO SCUPPER OPENING,
SLOPED FOR DRAINAGE
FASTEN TO DECK OR NAILERS AND
TO WALL USING APPROPRIATE
FASTENERS AT 8" O.C. MAXIMUM
PRIME AND SET IN ROOF CEMENT
OVER THE FIELD PLIES AND
INSTALL FLASHING AND STRIPPING
PLIES OVER NAILED FLANGES
MIN. 24 GA. PREFABRICATED SCUPPER
FLASHING TO CONFORM TO DIM. OF
OPENINGS AND SET IN ROOF CEMENT
ENERGYGUARD CANT STRIP
—SET IN BITUMEN
RUBEROID BASE FLASHING
HW PLUS FR.
PLY SHEETS
1/8" DENS DECK
ENERGYGUARD ROOF INSULATION
DECK MIN. 4" FLANGE
SURROUNDING
0 SCUPPER OPENING
0 — ALL JOINTS
�Q SOLDERED
SOLDERED BI —LEVEL FLANGE
Bi- Scupper Flashing T
Detail NTS SEE IMAGE #1, DETAIL 5/A -2
FOR SCUPPER
NOTE:
1. BASE FLASHING ON ALL 15 AND 20 YEAR GUARANTEE SYSTEMS MUST HAVE A
BASE PLY. REFER TO FLASHING MEMBRANE APPLICATION AND FLASHING
SPECIFICATION PLATES.
2. SEALANT AT TOP OF SURFACE MOUNTED COUNTER FLASHING IS A MAINTENCE ITEM
AND MUST BE MAINTAINED THROUGHOUT THE LIFE OF THE ROOF TO ENSURE A
WATER TIGHT SEAL
3. WALL FLASHING NOT DRAWN FOR CLARITY. SEE DETAIL 1/A -2 FOR WALL FLASHING
WITH SURFACE MOUNT DETAIL.
STAINLESS STEEL
BI —LEVEL SCUPPER
MIN 4" FLANGE SURROUNDING
SCUPPER OPENING — ALL
JOINTS SOLDERED"
SOLDERED t' �►, 4. >,, ;.
BI —LEVEL FLANGE t
pip, x P 9
_
mti
5 Image #01 nts
A -2
NOTE:
1. MASONRY WALLS TO BE
PRIMED PRIOR TO FLASHING.
2. BASE FLASHINGS TURNED OVER EDGE A
MINIMUM OF 1 1/2" (38mm) OR THICKNESS OF
NAILER WHICHEVER IS GREATER.
3. BASE FLASHING ON ALL 15 AND 20 YEAR
GUARANTEE SYSTEMS MUST HAVE A BASE PLY.
REFER TO FLASHING MEMBRANE APPLICATION
AND FLASHING SPECIFICATION PLATES.
FEATHER AT EDGE
FLEX AND FABRIC PLY 2
COURSES OF SURFACE SEAL
ON TOP OF PARAPET
TAPCONS APPROX. 3" O.C.
STAGGERED
METAL SET IN MASTIC WITH
MOP APPLIED MEMBRANES
—PRIME FLANGE BEFORE
STRIPPING
JOINT COVER 4" TO 6" WIDE
—SET IN MASTIC
—DO NOT USE MASTIC WITH
TORCH APPLIED MEMBRANES
NAIL AT 9" O.C.
ENERGYGUARD CANT STRIP
— SET IN BITUMEN
RUBEROID/ GAFGLAS BASE FLASHING
RUBEROID/ GAFGLAS MEMBRANE
BASE/ PLY SHEET(S)
ENERGYGUARD ROOF INSULATION
VAPOR RETARDER AS SPECIFIED
EXISTING CONCRETE DECK
Low Wall
1 Flashing Detail NTS
A -2
SPECIFICATION: I- 0- 3- 25/HGPFR (EC)
ROOF SURFACE
CAP SHEET
PLY SHEET
BASE SHEET
TAPERED INSULATION
ROOF DECK
COAfPONENT
TYPE
REQUIRED
ATTACHMENT
RATE OFAPPLICATION
DECK
Concrete
Per Code
INSULATION
EnergyGuardTM Polylso Roof
One (1) layer
OlyBond 500TM Adhesive
'/4" to 1" ribbons spaced 12" o.c.
Insulation
Minimum 1.5"
ASTM C 1289
ROOFBOARD
''/4" Dens Deck PrimeT14 Roof
One (1) layer
OlyBond 5001`M Adhesive
'/4" to I" ribbons spaced 12" o.c.
Board
ASTM C 1177
PLYSHEET
RUBEROIDV SBS Heat-
Two (2) plies
Heat Welded
Fully Adhered
We1dTM 25
L
ASTM D6163
CAP SHEET
RUBEROID®
One (1) ply
Heat Welded
Fully Adhered
SBS Heat- WeldTM Plus FR
ASTM D6164
FLASHING
RUBEROIDV SBS Heat-
One (1) ply
Heat Welded
Fully Adhered
2N25f1
WeldTM 25
■
ASTM D6163
L
RUBEROIDID
One (1) ply
Ileat Welded
Fully Adhered
SBS Heat- WeIdTM Plus FR
ASTM D6164
GUARANTEE
WeatherStopperO Diamond
Twenty (20)
GUARANTEE FEE IS
Pledge Guarantee
years
APPLICABLE
4 Roof Specification nts
A -2 NOTE:
1. ROOF SPECIFICATIONS ARE BASED ON GAF'S
MANUFACTURER SPECIFICATIONS. GC TO
PROVIDE ROOFING AS SPECIFIED OR AN EQUAL
APPROVED BY THE OWNER AND ARCHITECT.
2. NOA: 08- 1028.02, PAGE 9 OF 36
t ?Ii�1` -t `(t.- �UU1 I-i'1y11�11
BUILDING DEPT.
STRUCTU - A SECTION
L
ORBES
ARCHITECTS
-architecture
land planning
retail design
space planning
- conitruclion management
A56� ponce de Peon blvd.
suite 100
coral gables, Florida 33146
tel: 305.446.0849
fax: 305.444.5557
florlda registration
no. AA - F000104
a O O O O O O O
O O O O O O O O ,
O O O O O O O O
O O O O O O O O
O O O O O O O O
O O O O O O O O
O O O O a O a O
O O • O • O •• •
R,
y� t'+.
CL
1 S• 1f
W40 A �ft
John Roberts Forbes
AR0009810
OWNERSHIP AND USE OF THE DOCUMENTS:
THESE DRAWINGS, SCHEDULES, SPECInCATIONS
AND EXPRESSED IDEAS AS INSTRUMENTS OF
SERVICE ARE AND SHALL REMAIN THE
PROPERTY OF FORBES ARCHITECTS WHETHER
THE PROJECT FOR WHICH THEY ARE PREPARED
IS EXECUTED OR NOT. THE OWNER AND /OR
TENANT SHALL ONLY BE PERMITTED TO RETAIN
COPIES OF THESE DRAWINGS, SCHEDULES,
SPEonCATIOTS AND EXPRESSED IDEAS FOR
INFORMATION AND REFERENCE. THE DRAWINGS,
SCHEDULES. SPECIFICATIONS AND EXPRESSED
IDEAS SHALL NOT BE USED BY THE OWNER
AND /OR TENANT ON OTHER PROJECTS, FOR
ADOIRONS TO THIS PROJECT OR FOR
COMPLETION OF THE PROJECT BY OTHERS
EXCEPT BY AGREEMENT IN WRITING AND WITH
APPROPRIATE COMPENSAT19N TO FORBES
ARCHITECTS COPYRIGHT C 2009, JOHN
FORBES. INC., dba FORBES ARCHITECTS,
ALL RIGHTS RESERVED.
4—
O
O
r
L
■
L
CL4'
7k
CL
V/
O
t0
C
—
v
■ CL
>
M
m
`-
M
M
O
=
C
n
>
c
�
E
_°
v
ti
G
U
G
t0
c
N
• -
Lu
0 O w
O
O
ti
>
>
°o
V ♦ U)
U)
U)
ti
�
U
4)
�
�
EL
0
Date
01 -12 -12
Commission
11070
Revisions
0 01 -24 -12 ADDENDUM #1
Sheet
A -2 r