12-1353-042Oj INSTALL NEW PANEL 1 MNHI AND RE -FEED LOADS OF EXISTING PANELS D5, D6 & D8 AS WELL AS DUCT HEATER EDH -I. REFER TO RISER ON SHEET 3.02 FOR FURTHER DETAILS. FCU -M -2 O REPLACE EXISTING LIGHTS IN ROOM WITH NEW. REFER TO SHEET EO.01 FOR LIGHT FIXTURES SPECIFICATIONS. LA -29 MAIN BUILDING FIRST FLOOR ELECTRIC ROOM PLAN - PHASE 2E N f'I'I'r'I I 0' 2' 4' 8' 16' 24' KEYED NOTES O COORDINATE EXACT PLACEMENT OF FAN COIL UNIT IN FIELD TO ENSURE ALL CLEARANCES TO EXISTING PANELBOADS AND ATS's ARE MAINTAINED. MED GAS STORAGE REMOVE EXISTING EXHAUST FAN AND BRANCH CIRCUITING BACK TO SOURCE. ATS -2 T i N 1— Q ROOM 1 o. t 1 X LD Qw e m i 4 i Uj J -BOX O NORMAL —� EXISTING I I I SWBD I– MSBH3 — JI rO w L �I I ( . ROOM 10 f j EXISTING 300kVA IF XFMR MSBL3 If MAIN BUILDING FIRST FLOOR ELECTRIC ROOM PLAN - PHASE 2B N I'I'I'I'I I 0' 1' 2' 4' 8' 12' KEYED NOTES O ONCE ALL LOADS HAVE BEEN RE -FED, REMOVE EXISTING SWITCHBOARD MSBH3 AND ALL ASSOCIATED WIRING. DEMOLISH EXISTING CONDUITS NOT BEING REUSED TO THE FURTHEST EXTENT POSSIBLE. CUT AND CAP EXISTING UNDERGROUND CONDUITS FLUSH WITH THE FLOOR SLAB. O2 REMOVE EXISTING JUNCTION BOX ASSOCIATED WITH SPLICES FOR MSBH3. REMOVE ALL WIRING BACK TO SOURCE AND ALL CONDUITS TO THE FURTHEST EXTEND POSSIBLE. TURN OFF ASSOCIATED BREAKER IN MSN2 AND PROVIDE NEW LABEL TO INDICATE 'SPARE'. SEAL ALL UNUSED OPENINGS. O3 REMOVE EXISTING PANEL D8. O4 REMOVE ABANDONED ANNUNCIATOR PANEL AND ANY ALL OTHER ABANDONED EQUIPMENT, CABINETS, CONDUITS, EQUIPMENT, ETC WITHIN ROOM. O REMOVE ABANDONED EQUIPMENT, CONDUIT AND WIRING IN ROOM. CUT BACK ALL CONDUITS TO FURTHEST EXTENT POSSIBLE. UP TO B8 /E8 WIREWAY MED A STORAGE MAIN BUILDING FIRST FLOOR ELECTRIC ROOM ;PLAN - PHASE 2C N f i'T 0' 1' 2' 4' 8' 12' KEYED NOTES O1 INSTALL NEW XFMR IMCLDI, PANEL IMCLDI AND ASSOCIATED FEEDERS FROM 300A ENCLOSED BREAKER INSTALLED DURING PHASE 1. O INSTALL NEW FEEDER TO XFMR 1MCLDi TO 300A ENCLOSED BREAKER INSTALLED DURING PHASE 1. O INSTALL NEW CONDUIT ! AND FEEDERS TO EXISTING PANELS FED BY MSBL3 TO THE FURTHEST EXTENT POSSIBLE. COORDINATE A SHUTDOWN WITH THE HOSPITAL TO REMOVE EXISTING FEEDER AT EACH OF THESE EXISTING PANELS /LOADS AND CONNECT NEW FEEDER FROM IMCLDI. REFER TO RISER ON SHEET E3.02 FOR PANELS TO BE RE -FED. i XuoJ � I O ` m �.I a00 i REMOVE EXISTING EXHAUST FAN AND BRANCH CIRCUITING BACK TO SOURCE. MAIN BUILDING FIRST FLOOR ELECTRIC ROOM PLAN - PHASE 2' D N I'I'I'I'I I 0' it 2' 4' 8' 12' KEYED NOTES 0 ONCE ALL LOADS FROM MSBL3 HAVE BEEN RE -FED TO IMCLDI, REMOVE EXISTING SWITCHBOARD MSBL3, XFMR MSBL3 & DISCONECT SWITCH AND ALL ASSOCIATED FEEDER WIRING BACK TO SOURCE AND LOADS. REMOVE ALL CONDUITS TO THE FURTHEST EXTENT POSSIBLE. O CONTRACTOR SHALL CLEAN AND PAINT ENTIRE ROOM. REFER TO ARCHITECTURAL DOCUMENTS FOR PAINTING SPECIFICATIONS. CONSTRUCTION LEGEND SYMBOL DESCRIPTION EXISTING TO REMAIN - - -- EXISTING TO BE REMOVED NEW CONSTRUCTION Rte., R R Rte,. s__ R Na ithl C • an ld,inc. 600 ablest Hillsboro, Suite 300 Deerfield Reach, FL: 33441 (954) 421 -1260 ry AX: (904,- 421 -14ao www.ssr- inc.com Firm Certification - EB- 0000857 John E. Moulder PE - 33200 Michael A Steward PE - 65701 SSR JOB # 1232030.0 .J Q W U) (L 3: T z CM U3 O W w C 0 � I= _ =W �; "a o tiL Q O —z� �Q W C6 _ °� Cr o = 1—ZCn �� O Q U) U) �,�`G�PE�• srE`yq No • F : �Z' G %� .,CORIOP`.•��j �� S/O N rrrlil DRAWN CHECKED DATE 11/12/12 REVISED SHEET NO. MAIN BLDG ENLARGED ELEC RM FLOOR PLANS - PHASE 2 E2.03