12-1353-028NORTH TOWER FIRST FLOOR PLAN DEMOLITION - FIRE PRO TEC T l ON N NEW CONSTRUCTION - FIRE PRO TEC T l ON N 0' 1' 2' 4' 8' 12' 0' 1' 2' 4' 8' 12' GENERAL NOTES: 1. CONTRACTOR SHALL PHASE WORK AS DIRECTED BY OWNER. 2. CONTRACTOR SHALL PATCH WALLS, FLOORS, AND CEILINGS TO MATCH EXISTING FINISHES FOR DEMOLITION AND INSTALLATION OF FIRE PROTECTION SYSTEMS. COORDINATE WITH ARCHITECTURAL DRAWINGS. 3. THE HOSPITAL IS OPEN 24 HOURS A DAY, 7 DAYS A WEEK. THE CONTRACTOR SHALL HAVE TO PERFORM WORK WITHIN ACTIVE PATIENT CARE AREAS. CONTRACTOR SHALL: A. COORDINATE SHUTDOWN OF EXISTING SYSTEMS WELL IN ADVANCE WITH OWNER. B. PERFORM WORK AT SUCH TIMES AND UNDER SUCH CONDITIONS AS PRESCRIBED BY OWNER. C. PERFORM WORK WITHIN THE GUIDELINES OF THE ICRA REPORT PREPARED FOR THIS PROJECT BY THE OWNER. D. SEQUENCE DEMOLITION AND NEW CONSTRUCTION TO MINIMIZE NUMBER & DURATION OF SHUTDOWNS REQUIRED. WHERE FEASIBLE INSTALL NEW MAINS PRIOR TO DEMOLITION OF EXISTING. 4. CONTRACTOR SHALL COORDINATE WORK WITH EXISTING CONDITIONS (STRUCTURE, DUCTWORK, PIPING, CONDUIT, ETC.). PROVIDE OFFSETS AS REQUIRED TO INSTALL NEW WORK. 5. PIPING SHOWN TO BE REMOVED IS NOT TO BE CAPPED AND ABANDONED. 6. CONTRACTOR SHALL COORDINATE TIMING, DURATION AND AREAS AFFECTED BY SHUTDOWNS WITH HOSPITAL IN ORDER TO FACILITATE REQUIRED FIRE WATCH. 7. CONTRACTOR SHALL COORDINATE NEW SPRINKLER HEAD LOCATIONS WITH CEILING MOUNTED DEVICES (LIGHTS, DIFFUSERS, SMOKE DETECTORS, ETC.) AND OBSTRUCTIONS TO SPRINKLER THROW (SOFFITS, PRIVACY CURTAINS, ETC.) PER NFPA 13. 8. CONTRACTOR SHALL LABEL EXISTING PIPING, SHOWN ON THIS DRAWING TO REMAIN, WITHIN PROJECT SCOPE PER SPECIFICATIONS. KEYED NOTES: Oi REMOVE EXISTING SPRINKLER HEAD AND EXTEND EXISTING P BRANCH PIPING TO NEW SPRINKLER HEAD. SEE NEW CONSTRUCTION PLAN. COORDINATE ALL WORK INCLUDING PHASING AND SEQUENCING WITH DIV 26. SPRINKLER SCHEDULE 3 SPRINKLER HEADS REMOVED. 5 SPRINKLERS HEADS ADDED. 2 SPRINKLER HEAD ADDED DEMOLITION LEGEND SYMBOL DESCRIPTION r EXISTING TO REMAIN EXISTING TO BE REMOVED —� REMOVE EXISTING TO THIS POINT CONSTRUCTION LEGEND DESCRIPTION. r EXISTING TO REMAIN NEW CONSTRUCTION CONNECT TO EXIST. AT THIJPOINT KEY PLA SCALE N.T.S. AREA OF WORK :)F WORK N -T h mi h ev an elInc. 600 West Hillsboro, Suite 300 Daerfir ld Beach, FL 33441 (954) 421 -1260 FAX: X954) 421 -1466 www.ssr - inc.com Firm Certification - EB- 0000857 John E. Moulder PE-332W Michael A. Steward PE - 65701 SSR JOB # 1232030.0 J � Q W 3: �— T z �M Cn O W W M o�-� Iro _ =w CD Fr 70 o CV) U- Q O .� —Z� W � �a � � _°6OC o= F— Z U) co D — O � Q Q Cl) o� U `XXI11:> »i>>i �•` ��.•' G E N �. N 3 - C3 OF ''W= -' •�,#aiissss ��'' ``� 0 AL DRAWN CHECKED DATE 11/12/12 REVISED SHEET N0. NORTH TOWER - FIRST FLOOR PLAN - DEMO. & NEW CONSTRUCTION FIRE PROTECTION 0240 i�