12-1353-010LIFE SAFETY PLAN LEGEND 1 HR FIRE BARRIER _j 1 HR SMOKE BARRIER TYPE /FACTOR 1 HR FIRE BARRIER /SHAFT WALL CAPACITY IN LU 2 HR FIRE BARRIER COMPARTMENT 2 HR FSMOKE BARRIER PERSONS 2 HR BARRIER /SHAFT WALL LOAD 4 HR FIRE BARRIER SMOKE PARTITION (NON RATED) Z NON RATED STAIR /.3 EXIT ACCESS CORRIDOR 147 EXIT PASSAGE 10,835 2 HOUR 90 SUITE OF ROOMS 2 PERIMETER STAIR /.3 INSTITUTIONAL 147 OCCUPANCY 7B BUSINESS 13,085 OCCUPANCY 131 MB –STAIR 1 STAIR /.3 ASSEMBLY + + + 240 SF OCCUPANCY + + + + 44" AREA UNDER f" CONSTRUCTION 588 SMOKE T 265 COMPARTMENT WALL EXIT , EXIT SIGN – HATCH INDICATES EXIT TEXT ® ®�y AND ARROW INDICATES DIRECTION FIRE DEPARTMENT FDC CONNECTION 0 FEC FIRE EXTINGUISHER CABINET FE FIRE EXTINGUISHER PULL STATION STROBE LIGHT / HORN TOTAL TRAVEL DISTANCE 200' -0" TO AN EXIT TRAVEL DISTANCE TO 200 -0" — — — ADJACENT SMOKE ZONE EXITING SUMMARY _j EXIT TYPE /FACTOR WIDTH IN INCHES CAPACITY IN LU W COMPARTMENT PROVIDED PERSONS LOAD FACTOR LOAD Z P –STAIR 1 STAIR /.3 44" 147 w 10,835 120 SF 90 2 P –STAIR 3 STAIR /.3 44" 147 7B BUSINESS 13,085 100 SF 131 MB –STAIR 1 STAIR /.3 44" 147 240 SF MB –STAIR 2 STAIR /.3 44" 147 265 EXIT CAPACITY AVAILABLE 588 EXIT CAPACITY REQUIRED T 265 14TAIR 1 R q_ 20* PROJECT INFORMATION PROJECT NAME: BAPTIST HEALTH SOUTH MIAMI HOSPITAL LIFE SAFETY SURVEY ADDRESS: 6200 SW 73 STREET. SOUTH MIAMI, FL 33143 PROPOSED USE: LIFE SAFETY SURVEY OWNER – CONTACT PERSON: LUIS FERNANDEZ DE CASTRO PHONE: 786 - 6624660 APPLICABLE CODES – BUILDING CODE: 2007 FLORIDA BUILDING CODE W/2009 SUPPLEMENTS AND AIA GUIDELINES FOR DESIGN AND CONSTRUCTION OF HOSPITALS AND HEALTHCARE FACILITIES -2006 EDITION –FIRE CODE: 2006 NFPA 1. UNIFORM FIRE CODE / FLORIDA FIRE PREVENTION CODE 2007 –LIFE SAFETY CODE: NPFA 101 – LIFE SAFETY CODE 2009 – ACCESIBILITY CODE: 2007 FLORIDA BUILDING CODE W/2009 SUPPLEMENTS – CH.11 –STATE FIRE MARSHALL'S RULE 69A3.012 FAC: NFPA 10 -2002, STANDARD FOR PORTABLE FIRE EXTINGUISHERS NFPA 13 -2002, STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS NFPA 72 -2002, NATIONAL FIRE ALARM CODE NFPA 80 -1999, STANDARD FOR FIRE DOORS AND FIRE WINDOWS NFPA 99 -2005. STANDARD FOR HEALTH- CARE FACILITIES NFPA 105 -2003, SMOKE CONTROL DOOR ASSEMBLIES NFPA 221 -2006, STANDARD ON FIRE WALLS AND FIRE BARRIER WALLS BUILDING PLANNING OCCUPANCY: INSTITUTIONAL GROUP 1 (FBC 2006) MIXED OCCUPANCY? YES /(:2g) REQUIRED FIRE SEPARATION: 1 HR TYPE OF CONSTRUCTION CONSTRUCTION TYPE: FBC TYPE IB – NFPA 220 – TYPE II (2 -2 -2) SMOKE COMPARTMENT SUMMARY SMOKE PRIMARY AREA OCCUPANT W COMPARTMENT USE SF LOAD FACTOR LOAD PER PERSON = 7A SLEEPING 10,835 120 SF 90 7B BUSINESS 13,085 100 SF 131 7C TREATMENT 10.480 240 SF 44 TOTAL - SEVENTH LEVEL 34,400 265 T GUEST RELATIONS OFFICE WARNG CRS ILi1V \VI MOM COM THE f, txz/ 13,08 S.F. �— lI 1 , su PRIVATE ROOM PRIVATE ROOM PRIVATE ROOM PRIVATE ROOM PRIVATE ROOM PRIV ATE ROOM PRIVATE ROOM PRIVATE ROOM PRIVATE ROOM PRIVATE ROOM PRIVATE ROOM PRIVATE ROOM STCR NA7 I, rbs-'01 I I ITFAM71 7h 'd "' Mem pip l_►��._�Ir I M-11 11 ( 1� MOM Not I/ WE, mm � lmWu ISOL ROOM T\ T X10 TEL i CLO EIEG CLO NU LOUNGE u PRN ATE ROOM II PRIVATE ROOM 11 PRIVATE ROOM II PRP. ATF ROORI 11 PRIVATE ROOM 11 PRIVATE ROOM II PRIVATE ROCM 11 PF J�lATE ROOM STAIR 3 REQ. 20" PROV. 44" \�N STAR) IIM \II T II SLEEPING II SLEEPHO T Ix STOR _I_ ?ter. k1 ® ❑ STAFF ACCIS SM KE COM 4SART 10 I—q ❑ CLO V V OR T NURS OF ki EIC CS .GNO YN TLSERVICES EES EMU RESP. V STORAGE ROOM ROOM I �� : �� �nu� Alm STAIR 6 cm am II %m �� ■�, SUITE ••�• mg—m- N�T o. �...� !�!�!�!�!�! -lam-! 7C Fwm � /_. �I ©i • �II'III'Ill ". PARTIAL SEVENTH FLOOR LIFE SAFETY PLAN 1/16"= 1' -0" 0 4' 8' 16' 32' 48' 64' 80' GRAPHIC SCALE am N. FEMPT UL lam LWITE 04 A W STAIR 7 REQ. 20" Smith Seckman -_- —_- - Reid, Inc. 600 West Hillsboro, Suite 300 Deerfield Beach, FL 33441 (G54) A21 -1260 FAX* (95 -1) 421 -1466 - - -- ­vv ,v-,, Firm Certification – ES- 0000857 John E. Moulder PE – 33200 Michael A. Steward PE – 65701 SSR JOB # 1232030.0 H I<S HKS ARCHITECTS, INC. #AA F000119 1221 BRICKELL AVENUE SUITE 1220 MIAMI, FL 33131 305 - 416 -6100 KEYPLAN C W 0 J Q v � 0- M �� WQ O �o _ W -I- J Ce) LL G �C/) U� _ -j N = Q(0 oz Cn LWA' _ I Cn W DRAWN CHECKED DATE 11 -12 -12 REVISED SHEET N0. SEVENTH FLOOR LIFE SAFETY PLAN LS -71