Loading...
12-1353-009I i i i i i LIFE SAFETY PLAN LEGEND 1 HR FIRE BARRIER 1 HR SMOKE BARRIER 1 HR FIRE BARRIER /SHAFT WALL 2 HR FIRE BARRIER 2 HR FSMOKE BARRIER 2 HR BARRIER /SHAFT WALL 4 HR FIRE BARRIER SMOKE PARTITION (NON RATED) NON RATED EXIT ACCESS CORRIDOR j EXIT PASSAGE SUPPLEMENTS AND AIA GUIDELINES FOR 2 HOUR ® ®�y SUITE OF ROOMS H PERIMETER 2006 NFPA 1. UNIFORM FIRE CODE / INSTITUTIONAL FDC OCCUPANCY 0 BUSINESS . . . . . OCCUPANCY - ASSEMBLY + + + OCCUPANCY + + + + AREA UNDER CONSTRUCTION � J SMOKE COMPARTMENT WALL EXIT ► EXIT SIGN — HATCH SUPPLEMENTS AND AIA GUIDELINES FOR INDICATES EXIT TEXT ® ®�y AND ARROW H INDICATES DIRECTION 2006 NFPA 1. UNIFORM FIRE CODE / FIRE DEPARTMENT FDC CONNECTION 0 — ACCESIBILITY CODE: FEC FIRE EXTINGUISHER CABINET - —STATE FIRE MARSHALL'S RULE 69A3.012 FAC: FE FIRE EXTINGUISHER PULL STATION NFPA 13 -2002, STANDARD FOR THE PROJECT INFORMATION PROJECT NAME: BAPTIST HEALTH SOUTH MIAMI HOSPITAL LIFE SAFETY SURVEY ADDRESS: 6200 SW 73 STREET. SOUTH MIAMI, FL 33143 PROPOSED USE: LIFE SAFETY SURVEY OWNER — CONTACT PERSON: LUIS FERNANDEZ DE CASTRO PHONE: 786 - 6624660 APPLICABLE CODES — BUILDING CODE: 2007 FLORIDA BUILDING CODE W/2009 SUPPLEMENTS AND AIA GUIDELINES FOR DESIGN AND CONSTRUCTION OF HOSPITALS AND HEALTHCARE FACILITIES -2006 EDITION —FIRE CODE: 2006 NFPA 1. UNIFORM FIRE CODE / FLORIDA FIRE PREVENTION CODE 2007 —LIFE SAFETY CODE: NPFA 101 — LIFE SAFETY CODE 2009 — ACCESIBILITY CODE: 2007 FLORIDA BUILDING CODE W/2009 SUPPLEMENTS — CH.11 —STATE FIRE MARSHALL'S RULE 69A3.012 FAC: NFPA 10 -2002, STANDARD FOR PORTABLE FIRE EXTINGUISHERS NFPA 13 -2002, STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS NFPA 72 -2002, NATIONAL FIRE ALARM NFPA 80 -1999, STANDARD FOR FIRE DOORS AND FIRE WINDOWS NFPA 99 -2005, STANDARD FOR HEALTH- CARE FACILITIES NFPA 105 -2003, SMOKE CONTROL DOOR ASSEMBLIES NFPA 221 -2006, STANDARD ON FIRE WALLS AND FIRE BARRIER WALLS BUILDING PLANNING OCCUPANCY: INSTITUTIONAL GROUP 1 (FBC 2006) MIXED OCCUPANCY? YES /(HO) REQUIRED FIRE SEPARATION: 1 HR TYPE OF CONSTRUCTION CONSTRUCTION TYPE: FBC TYPE IB — NFPA 220 — TYPE II (2 -2 -2) PARTIAL SIXTH FLOOR LIFE SAFETY PLAN 1/16"=l'-O" 0 4' 8' 16' 32' 48' 64' 80' � e � GRAPHIC SCALE ------ ----- SRSmith Seckman Reid, Inc. 600 West Hillsboro, Suite 300 - Deerfield Beach, FL 33441 - - (1454) 421 -1260 _FAQ:: (964) 421 -1466 --- w,"r ssr- mc.com Firm Certification — EB- 0000857 John E. Moulder PE — 33200 Michael A. Steward PE — 65701 SSR JOB # 1232030.0 HI<S HKS ARCHITECTS, INC. #AA F000119 1221 BRICKELL AVENUE SUITE 1220 MIAMI, FL 33131 305 - 416 -6100 KEYPLAN C/ W J Q v � �- c�i C/) WQ O �o _ W -a 0 _j Ce) LL Q U) � �U) Uj� N = �-- Q cD � o OZ Cn W Cn Cn W DRAWN CHECKED DATE 11 -12 -12 REVISED SHEET NO. SIXTH FLOOR LIFE SAFETY PLAN LS -61