Loading...
12-1353-008I I I I LIFE SAFETY PLAN LEGEND 1 HR FIRE BARRIER 2007 FLORIDA BUILDING CODE W/2009 1 HR SMOKE BARRIER r + + + 1 HR FIRE BARRIER /SHAFT WALL + + + + 2 HR FIRE BARRIER AND HEALTHCARE FACILITIES -2006 EDITION 2 HR FSMOKE BARRIER . . . . . 2 HR BARRIER /SHAFT WALL FLORIDA FIRE PREVENTION CODE 2007 4 HR FIRE BARRIER NPFA 101 — LIFE SAFETY CODE 2009 SMOKE PARTITION (NON RATED) 2007 FLORIDA BUILDING CODE W/2009 NON RATED , EXIT ACCESS CORRIDOR EXIT PASSAGE ® ® 44, 2 HOUR F> SUITE OF ROOMS 2007 FLORIDA BUILDING CODE W/2009 PERIMETER r + + + INSTITUTIONAL + + + + OCCUPANCY AND HEALTHCARE FACILITIES -2006 EDITION BUSINESS . . . . . OCCUPANCY FLORIDA FIRE PREVENTION CODE 2007 PROJECT INFORMATION PROJECT NAME: BAPTIST HEALTH SOUTH MIAMI HOSPITAL LIFE SAFETY SURVEY ADDRESS: 6200 SW 73 STREET. SOUTH MIAMI, FL 33143 PROPOSED USE: LIFE SAFETY SURVEY OWNER — CONTACT PERSON: LUIS FERNANDEZ DE CASTRO PHONE: 786 - 6624660 APPLICABLE CODES — BUILDING CODE: 2007 FLORIDA BUILDING CODE W/2009 ASSEMBLY r + + + OCCUPANCY + + + + AREA UNDER AND HEALTHCARE FACILITIES -2006 EDITION CONSTRUCTION f f SMOKE FLORIDA FIRE PREVENTION CODE 2007 COMPARTMENT NPFA 101 — LIFE SAFETY CODE 2009 WALL 2007 FLORIDA BUILDING CODE W/2009 EXIT , EXIT SIGN — HATCH INDICATES EXIT TEXT ® ® 44, AND ARROW F> INDICATES DIRECTION FIRE DEPARTMENT FDC CONNECTION `♦ CODE FEC FIRE EXTINGUISHER CABINET DOORS AND FIRE WINDOWS FE FIRE EXTINGUISHER PULL STATION NFPA 105 -2003. SMOKE CONTROL DOOR PROJECT INFORMATION PROJECT NAME: BAPTIST HEALTH SOUTH MIAMI HOSPITAL LIFE SAFETY SURVEY ADDRESS: 6200 SW 73 STREET. SOUTH MIAMI, FL 33143 PROPOSED USE: LIFE SAFETY SURVEY OWNER — CONTACT PERSON: LUIS FERNANDEZ DE CASTRO PHONE: 786 - 6624660 APPLICABLE CODES — BUILDING CODE: 2007 FLORIDA BUILDING CODE W/2009 SUPPLEMENTS AND AIA GUIDELINES FOR DESIGN AND CONSTRUCTION OF HOSPITALS AND HEALTHCARE FACILITIES -2006 EDITION —FIRE CODE: 2006 NFPA 1. UNIFORM FIRE CODE / FLORIDA FIRE PREVENTION CODE 2007 —LIFE SAFETY CODE: NPFA 101 — LIFE SAFETY CODE 2009 — ACCESIBILITY CODE: 2007 FLORIDA BUILDING CODE W/2009 SUPPLEMENTS — CH.11 —STATE FIRE MARSHALL'S RULE 69A3.012 FAC: NFPA 10 -2002, STANDARD FOR PORTABLE FIRE EXTINGUISHERS NFPA 13 -2002, STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS NFPA 72 -2002, NATIONAL FIRE ALARM CODE NFPA 80 -1999, STANDARD FOR FIRE DOORS AND FIRE WINDOWS NFPA 99 -2005. STANDARD FOR HEALTH- CARE FACILITIES NFPA 105 -2003. SMOKE CONTROL DOOR ASSEMBLIES NFPA 221 -2006, STANDARD ON FIRE WALLS AND FIRE BARRIER WALLS BUILDING PLANNING OCCUPANCY: INSTITUTIONAL GROUP 1 (FBC 2006) MIXED OCCUPANCY? YES /(2D REQUIRED FIRE SEPARATION: 1 HR TYPE OF CONSTRUCTION CONSTRUCTION TYPE: FBC TYPE IB — NFPA 220 — TYPE II (2 -2 -2) 4% PARTIAL FIFTH FLOOR LIFE SAFETY PLAN Kl.,U 1/16"=l'-O" 0 4' 8' 16' 32' 48' 64' 80' GRAPHIC SCALE i- - - - -- - -- Smith Seckman Reid, Inc. 600 West Hillsboro, Suite 300 _Deerfield Beach, FL 33441 - - - (464) 421 -1260 _FAX-: (9,")4211-11466 - - - wvw.- ssr- inc.com Firm Certification — ES- 0000857 John E. Moulder PE — 33200 Michael A. Steward PE — 65701 SSR JOB # 1232030.0 HI<S HKS ARCHITECTS, INC. #AA F000119 1221 BRICKELL AVENUE SUITE 1220 MIAMI, FL 33131 305 -416 -6100 KEYPLAN ( W J Q v � a' 0- M wQ O ro U� _w -0o QU) � �U) U� N= D o Oz U) w W U) W DRAWN CHECKED DATE 11 -12 -12 REVISED SHEET NO'. FIFTH FLOOR LIFE SAFETY PLAN LS -51