12-1353-007LIFE SAFETY PLAN LEGEND 1 HR FIRE BARRIER 1 HR SMOKE BARRIER 1 HR FIRE BARRIER /SHAFT WALL 2 HR FIRE BARRIER 2 HR FSMOKE BARRIER 2 HR BARRIER /SHAFT WALL 4 HR FIRE BARRIER SMOKE PARTITION (NON RATED) NON RATED EXIT ACCESS CORRIDOR j EXIT PASSAGE TYPE /FACTOR 2 HOUR ® ® 44. SUITE OF ROOMS BUILDING PLANNING PERIMETER 44" INSTITUTIONAL LLJ OCCUPANCY STAIR /.3 BUSINESS OCCUPANCY: INSTITUTIONAL GROUP 1 (FBC 2006) OCCUPANCY FD ASSEMBLY + + + OCCUPANCY + + + + AREA UNDER CONSTRUCTION SMOKE COMPARTMENT WALL EXIT , PROJECT INFORMATION PROJECT NAME: BAPTIST HEALTH SOUTH MIAMI HOSPITAL LIFE SAFETY SURVEY ADDRESS: 6200 SW 73 STREET. SOUTH MIAMI, FL 33143 PROPOSED USE: LIFE SAFETY SURVEY OWNER — CONTACT PERSON: LUIS FERNANDEZ DE CASTRO PHONE: 786 - 6624660 APPLICABLE CODES — BUILDING CODE: 2007 FLORIDA BUILDING CODE W/2009 SUPPLEMENTS AND AIA GUIDELINES FOR DESIGN AND CONSTRUCTION OF HOSPITALS AND HEALTHCARE FACILITIES -2006 EDITION —FIRE CODE: 2006 NFPA 1. UNIFORM FIRE CODE / FLORIDA FIRE PREVENTION CODE 2007 —LIFE SAFETY CODE: NPFA 101 — LIFE SAFETY CODE 2009 — ACCESIBILITY CODE: 2007 FLORIDA BUILDING CODE W/2009 SUPPLEMENTS — CH.11 —STATE FIRE MARSHALL'S RULE 69A3.012 FAC: NFPA 10 -2002, STANDARD FOR PORTABLE FIRE EXTINGUISHERS NFPA 13 -2002, STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS NFPA 72 -2002, NATIONAL FIRE ALARM CODE NFPA 80 -1999, STANDARD FOR FIRE DOORS AND FIRE WINDOWS NFPA 99 -2005, STANDARD FOR HEALTH- CARE FACILITIES NFPA 105 -2003, SMOKE CONTROL DOOR ASSEMBLIES NFPA 221 -2006, STANDARD ON FIRE WALLS AND FIRE BARRIER WALLS EXIT SIGN — HATCH EXIT TYPE /FACTOR INDICATES EXIT TEXT ® ® 44. = BUILDING PLANNING AND ARROW 44" 147 LLJ INDICATES DIRECTION STAIR /.3 44" OCCUPANCY: INSTITUTIONAL GROUP 1 (FBC 2006) FIRE DEPARTMENT FD STAIR /.3 MIXED OCCUPANCY? YES / NO CONNECTION REQUIRED FIRE SEPARATION: 1 HR FEC EXIT CAPACITY AVAILABLE FIRE EXTINGUISHER CABINET EXIT CAPACITY REQUIRED I" FE TYPE OF CONSTRUCTION FIRE EXTINGUISHER CONSTRUCTION TYPE: FBC TYPE IB — NFPA 220 PULL STATION — TYPE II (2 -2 -2) STROBE LIGHT / HORN TOTAL TRAVEL DISTANCE TO AN EXIT TRAVEL DISTANCE TO 200' -0" — ADJACENT SMOKE ZONE EXITING SUMMARY EXIT TYPE /FACTOR WIDTH IN INCHES PROVIDED CAPACITY N PERSONS = STAIR 1 STAIR /.3 44" 147 LLJ STAIR 3 STAIR /.3 44" 147 STAIR 7 STAIR /.3 44" 147 EXIT CAPACITY AVAILABLE 441 EXIT CAPACITY REQUIRED I" SMOKE COMPARTMENT SUMMARY PARTIAL FOURTH FLOOR LIFE SAFETY PLAN 1/16"= 1' -0" 0 4' 8' 16' 32' 48' 64' 80' GRAPHIC SCALE Smith Seckman :8 Reid, Inc. 600 West Hillsboro, Suite 300 Deerfield Beach, FL 33441 - (4� 421 -1260 - FAX: (9.iA) 421 -1466 -- - www,ssr- Inc.com Firm Certification — EB- 0000857 John E. Moulder PE — 33200 Michael A. Steward PE — 65701 SSR JOB # 1232030.0 HI<S HKS ARCHITECTS, INC. #AA F000119 1221 BRICKELL AVENUE SUITE 1220 MIAMI, FL 33131 305 -416 -6100 KEYPLAN F, — U) W 0 co v � wQ cj�o �. _ W -� J Cy) LL U) G �U) 0� C:) D O Oz U) W rU) �/ W OF F 111� •.0900. C •� O.Qi hQ�•�v\0 I O 7 > �( > ' 92399 LLJ � F4EC�•P�G�\ DRAWN CHECKED DATE 11 -12 -12 REVISED SHEET N0. FOURTH FLOOR LIFE SAFETY PLAN LS -41