12-1353-007LIFE SAFETY PLAN LEGEND
1 HR FIRE BARRIER
1 HR SMOKE BARRIER
1 HR FIRE BARRIER /SHAFT WALL
2 HR FIRE BARRIER
2 HR FSMOKE BARRIER
2 HR BARRIER /SHAFT WALL
4 HR FIRE BARRIER
SMOKE PARTITION (NON RATED)
NON RATED
EXIT ACCESS CORRIDOR
j
EXIT PASSAGE
TYPE /FACTOR
2 HOUR
® ® 44.
SUITE OF ROOMS
BUILDING PLANNING
PERIMETER
44"
INSTITUTIONAL
LLJ
OCCUPANCY
STAIR /.3
BUSINESS
OCCUPANCY: INSTITUTIONAL GROUP 1 (FBC 2006)
OCCUPANCY
FD
ASSEMBLY + + +
OCCUPANCY + + + +
AREA UNDER
CONSTRUCTION
SMOKE
COMPARTMENT
WALL
EXIT ,
PROJECT INFORMATION
PROJECT NAME: BAPTIST HEALTH SOUTH MIAMI HOSPITAL
LIFE SAFETY SURVEY
ADDRESS: 6200 SW 73 STREET. SOUTH MIAMI, FL 33143
PROPOSED USE: LIFE SAFETY SURVEY
OWNER — CONTACT PERSON: LUIS FERNANDEZ DE CASTRO
PHONE: 786 - 6624660
APPLICABLE CODES
— BUILDING CODE: 2007 FLORIDA BUILDING CODE W/2009
SUPPLEMENTS AND AIA GUIDELINES FOR
DESIGN AND CONSTRUCTION OF HOSPITALS
AND HEALTHCARE FACILITIES -2006 EDITION
—FIRE CODE: 2006 NFPA 1. UNIFORM FIRE CODE /
FLORIDA FIRE PREVENTION CODE 2007
—LIFE SAFETY CODE: NPFA 101 — LIFE SAFETY CODE 2009
— ACCESIBILITY CODE: 2007 FLORIDA BUILDING CODE W/2009
SUPPLEMENTS — CH.11
—STATE FIRE MARSHALL'S RULE 69A3.012 FAC:
NFPA 10 -2002, STANDARD FOR PORTABLE
FIRE EXTINGUISHERS
NFPA 13 -2002, STANDARD FOR THE
INSTALLATION OF SPRINKLER SYSTEMS
NFPA 72 -2002, NATIONAL FIRE ALARM
CODE
NFPA 80 -1999, STANDARD FOR FIRE
DOORS AND FIRE WINDOWS
NFPA 99 -2005, STANDARD FOR HEALTH-
CARE FACILITIES
NFPA 105 -2003, SMOKE CONTROL DOOR
ASSEMBLIES
NFPA 221 -2006, STANDARD ON FIRE
WALLS AND FIRE BARRIER WALLS
EXIT SIGN — HATCH
EXIT
TYPE /FACTOR
INDICATES EXIT TEXT
® ® 44.
=
BUILDING PLANNING
AND ARROW
44"
147
LLJ
INDICATES DIRECTION
STAIR /.3
44"
OCCUPANCY: INSTITUTIONAL GROUP 1 (FBC 2006)
FIRE DEPARTMENT
FD
STAIR /.3
MIXED OCCUPANCY? YES / NO
CONNECTION
REQUIRED FIRE SEPARATION: 1 HR
FEC
EXIT CAPACITY AVAILABLE
FIRE EXTINGUISHER CABINET
EXIT CAPACITY REQUIRED
I"
FE
TYPE OF CONSTRUCTION
FIRE EXTINGUISHER
CONSTRUCTION TYPE: FBC TYPE IB — NFPA 220
PULL STATION
— TYPE II (2 -2 -2)
STROBE LIGHT / HORN
TOTAL TRAVEL DISTANCE
TO AN EXIT
TRAVEL DISTANCE TO
200' -0"
—
ADJACENT SMOKE ZONE
EXITING SUMMARY
EXIT
TYPE /FACTOR
WIDTH IN
INCHES
PROVIDED
CAPACITY
N
PERSONS
=
STAIR 1
STAIR /.3
44"
147
LLJ
STAIR 3
STAIR /.3
44"
147
STAIR 7
STAIR /.3
44"
147
EXIT CAPACITY AVAILABLE
441
EXIT CAPACITY REQUIRED
I"
SMOKE COMPARTMENT SUMMARY
PARTIAL FOURTH FLOOR LIFE SAFETY PLAN
1/16"= 1' -0"
0 4' 8' 16' 32' 48' 64' 80'
GRAPHIC SCALE
Smith
Seckman
:8 Reid, Inc.
600 West Hillsboro, Suite 300
Deerfield Beach, FL 33441
- (4� 421 -1260
- FAX: (9.iA) 421 -1466
-- - www,ssr- Inc.com
Firm Certification — EB- 0000857
John E. Moulder PE — 33200
Michael A. Steward PE — 65701
SSR JOB # 1232030.0
HI<S
HKS ARCHITECTS, INC.
#AA F000119
1221 BRICKELL AVENUE
SUITE 1220
MIAMI, FL 33131
305 -416 -6100
KEYPLAN
F, —
U)
W
0
co
v �
wQ
cj�o
�.
_ W -� J
Cy) LL
U)
G
�U) 0� C:)
D O
Oz
U) W
rU)
�/
W
OF F
111� •.0900.
C •�
O.Qi
hQ�•�v\0
I O
7
> �( >
' 92399
LLJ
� F4EC�•P�G�\
DRAWN
CHECKED
DATE 11 -12 -12
REVISED
SHEET N0.
FOURTH
FLOOR LIFE
SAFETY PLAN
LS -41