Loading...
12-1353-006LIFE SAFETY PLAN LEGEND 1 HR FIRE BARRIER 1 HR SMOKE BARRIER TYPE /FACTOR 1 HR FIRE BARRIER /SHAFT WALL CAPACITY IN PERSONS 2 HR FIRE BARRIER STAIR 1 2 HR FSMOKE BARRIER 44" 2 HR BARRIER /SHAFT WALL 120 SF 4 HR FIRE BARRIER STAIR /.3 SMOKE PARTITION (NON RATED) 147 NON RATED STAIR 4 EXIT ACCESS CORRIDOR rXE///Ex EXIT PASSAGE 2 HOUR SUITE OF ROOMS PERIMETER INSTITUTIONAL OCCUPANCY BUSINESS OCCUPANCY ASSEMBLY OCCUPANCY AREA UNDER CONSTRUCTION SMOKE COMPARTMENT WALL EXIT EXIT SIGN — HATCH INDICATES EXIT TEXT AND ARROW INDICATES DIRECTION FIRE DEPARTMENT CONNECTION FIRE EXTINGUISHER CABINET FIRE EXTINGUISHER PULL STATION STROBE LIGHT / HORN TOTAL TRAVEL DISTANCE TO AN EXIT TRAVEL DISTANCE TO ADJACENT SMOKE ZONE fl FDC 0 FEC FE 200' -0" 200' -0" EXITING SUMMARY EXIT TYPE /FACTOR WIDTH IN INCHES PROVIDED CAPACITY IN PERSONS M a- STAIR 1 STAIR /.3 44" 147 120 SF STAIR 3 STAIR /.3 44" 147 13,375 STAIR 4 STAIR /.3 44" 147 TREATMENT STAIR 5 STAIR /.3 44" 147 3D STAIR 7 STAIR /.3 44" 147 3E SLEEPING 12,440 120 SF 104 EXIT CAPACITY AVAILABLE 733 EXIT CAPACITY REQUIRED 500 120 SF PROJECT INFORMATION PROJECT NAME: BAPTIST HEALTH SOUTH MIAMI HOSPITAL LIFE SAFETY SURVEY ADDRESS: 6200 SW 73 STREET. SOUTH MIAMI, FL 33143 PROPOSED USE: LIFE SAFETY SURVEY OWNER — CONTACT PERSON: LUIS FERNANDEZ DE CASTRO PHONE: 786 - 6624660 APPLICABLE CODES — BUILDING CODE: 2007 FLORIDA BUILDING CODE W/2009 SUPPLEMENTS AND AIA GUIDELINES FOR DESIGN AND CONSTRUCTION OF HOSPITALS AND HEALTHCARE FACILITIES -2006 EDITION —FIRE CODE: 2006 NFPA 1. UNIFORM FIRE CODE / FLORIDA FIRE PREVENTION CODE 2007 —LIFE SAFETY CODE: NPFA 101 — LIFE SAFETY CODE 2009 — ACCESIBILITY CODE: 2007 FLORIDA BUILDING CODE W/2009 SUPPLEMENTS — CH.11 —STATE FIRE MARSHALL'S RULE 69A3.012 FAC: NFPA 10 -2002, STANDARD FOR PORTABLE FIRE EXTINGUISHERS NFPA 13 -2002, STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS NFPA 72 -2002, NATIONAL FIRE ALARM CODE NFPA 80 -1999, STANDARD FOR FIRE DOORS AND FIRE WINDOWS NFPA 99 -2005, STANDARD FOR HEALTH- CARE FACILITIES NFPA 105 -2003, SMOKE CONTROL DOOR ASSEMBLIES NFPA 221 -2006, STANDARD ON FIRE WALLS AND FIRE BARRIER WALLS BUILDING PLANNING OCCUPANCY: _ INSTITUTIONAL GROUP 1 (FBC 2006) MIXED OCCUPANCY? YES /(NO REQUIRED FIRE SEPARATION: 1 HR TYPE OF CONSTRUCTION CONSTRUCTION TYPE: FBC TYPE IB — NFPA 220 — TYPE II (2 -2 -2) SMOKE COMPARTMENT SUMMARY SMOKE COMPARTMENT PRIMARY USE AREA SF OCCUPANT LOAD FACTOR ERSON OCCUPANT LOAD 0 a- 3A SLEEPING 10,720 120 SF 90 3B SLEEPING 13,375 120 SF 112 3C TREATMENT 10,125 240 SF 42 3D SLEEPING 14,410 120 SF 120 3E SLEEPING 12,440 120 SF 104 3F SLEEPING 9,060 120 SF 76 TOTAL - THIRD LEVEL 70,130 544 THIRD FLOOR LIFE SAFETY PLAN 1/16"= 1' -0" 0 4' 8' 16' 32' 48' 64' 80' GRAPHIC SCALE MATCHLNE REF. LS -31 _ Smith Seckman Reid, Inc. 600 West Hillsboro, Suite 300 _ Deerfield Beach, FL 33441 (964+ 421 -1260 FAX: (964) 421 -1466 - - - - mvw.ssr- Inc.com Firm Certification — EB- 0000857 John E. Moulder PE — 33200 Michael A. Steward PE — 65701 SSR JOB # 1232030.0 HI<S HKS ARCHITECTS, INC. #AA F000119 1221 BRICKELL AVENUE SUITE 1220 MIAMI, FL 33131 305 -416 -6100 KEYPLAN U) W J Q v � �- M �� wQ O �o U) 0 _ W '0 _j ce) LL G _ >- 3: Q Cn (6 2 N = �Q CD :D O oz C/) W W OF F co N J2399: V LLJ RED PR DRAWN CHECKED DATE 11 -12 -12 REVISED SHEET N0. THIRD FLOOR LIFE SAFETY PLAN LS -32