12-1353-004LIFE SAFETY PLAN LEGEND
1 HR FIRE BARRIER
1 HR SMOKE BARRIER
TYPE /FACTOR
1 HR FIRE BARRIER /SHAFT WALL
CAPACITY
PERSONS
2 HR FIRE BARRIER
STAIR 1
2 HR FSMOKE BARRIER
44"
2 HR BARRIER /SHAFT WALL
L)
N
4 HR FIRE BARRIER
STAIR /.3
SMOKE PARTITION (NON RATED)
147
NON RATED
STAIR 4
EXIT ACCESS CORRIDOR
v_z
- e11111
EXIT PASSAGE
2 HOUR
STAIR /.3
SUITE OF ROOMS
147
PERIMETER
STAIR 7
INSTITUTIONAL
44"
OCCUPANCY
Z
0
BUSINESS
. . • • .
OCCUPANCY
147
+ +.
ASSEMBLY
�- .
OCCUPANCY
+ + + +
AREA UNDER
r.T 71
CONSTRUCTION
f
10,215
L _ _/J
SMOKE
44"
COMPARTMENT
TREATMENT
WALL
1323
EXIT
,
EXIT SIGN - HATCH
TREATMENT
INDICATES EXIT TEXT
1
AND ARROW
INDICATES DIRECTION
TREATMENT
FIRE DEPARTMENT
FDC
0
CONNECTION
2F
FEC
FIRE EXTINGUISHER CABINET
120 SF
88
FE
FIRE EXTINGUISHER
'
PULL STATION
240 SF
STROBE LIGHT / HORN
TOTAL TRAVEL DISTANCE
200' -0"
TO AN EXIT
240 SF
TRAVEL DISTANCE TO
200 -0"
a-'• — — —
ADJACENT SMOKE ZONE
SLEEPING
EXITING SUMMARY
EXIT
TYPE /FACTOR
WIDTH IN
INCHES
PROVIDED
CAPACITY
PERSONS
°
Z
0
STAIR 1
STAIR /.3
44"
147
L)
N
STAIR 3
STAIR /.3
44"
147
STAIR 4
STAIR /.3
44"
147
STAIR 5
STAIR /.3
44"
147
2A
STAIR 7
STAIR /.3
44"
147
Z
0
STAIR 8
STAIR /.3
44"
147
STAIR 9
STAIR /.3
44"
147
STAIR 10
STAIR /.3
44"
147
10,215
STAIR 11
STAIR /.3
44"
147
TREATMENT
EXIT CAPACITY AVAILABLE
1323
EXIT CAPACITY REQUIRED
509
2D
PROJECT INFORMATION
PROJECT NAME: BAPTIST HEALTH SOUTH MIAMI HOSPITAL
LIFE SAFETY SURVEY
ADDRESS: 6200 SW 73 STREET. SOUTH MIAMI, FL 33143
PROPOSED USE: LIFE SAFETY SURVEY
OWNER – CONTACT PERSON: LUIS FERNANDEZ DE CASTRO
PHONE: 786 - 6624660
APPLICABLE CODES
- BUILDING CODE: 2007 FLORIDA BUILDING CODE W/2009
SUPPLEMENTS AND AIA GUIDELINES FOR
DESIGN AND CONSTRUCTION OF HOSPITALS
AND HEALTHCARE FACILMES -2006 EDITION
-FIRE CODE: 2006 NFPA 1. UNIFORM FIRE CODE /
FLORIDA FIRE PREVENTION CODE 2007
-LIFE SAFETY CODE: NPFA 101 - LIFE SAFETY CODE 2009
- ACCESIBIUTY CODE: 2007 FLORIDA BUILDING CODE W/2009
SUPPLEMENTS - CH.11
-STATE FIRE MARSHALL'S RULE 69A3.012 FAC:
NFPA 10 -2002, STANDARD FOR PORTABLE
FIRE EXTINGUISHERS
NFPA 13 -2002, STANDARD FOR THE
INSTALLATION OF SPRINKLER SYSTEMS
NFPA 72 -2002, NATIONAL FIRE ALARM
CODE
NFPA 80 -1999, STANDARD FOR FIRE
DOORS AND FIRE WINDOWS
NFPA 99 -2005, STANDARD FOR HEALTH-
CARE FACILITIES
NFPA 105 -2003, SMOKE CONTROL DOOR
ASSEMBLIES
NFPA 221 -2006, STANDARD ON FIRE
WALLS AND FIRE BARRIER WALLS
BUILDING PLANNING
OCCUPANCY: INSTITUTIONAL GROUP 1 (FBC 2006)
MIXED OCCUPANCY? YES /(2ND
REQUIRED FIRE SEPARATION: 1 HR
TYPE OF CONSTRUCTION
CONSTRUCTION TYPE: FBC TYPE IB - NFPA 220
- TYPE II (2 -2 -2)
SMOKE COMPARTMENT SUMMARY
SMOKE
PRIMARY
AREA
OCCUPANT
OCCUPANT
- •
COMPARTMENT
USE
SF
LOAD
PER PERSON
J
r�
°
2A
SLEEPING
13,580
120 SF
113
Z
0
C
28
TREATMENT
10,215
240 SF
43
2C
TREATMENT
13,580
240 SF
53
2D
TREATMENT
10,775
240 SF
45
2E
TREATMENT
15.465
240 SF
65
2F
SLEEPING
10.510
120 SF
88
213
TREATMENT
7,625
240 SF
32
2H
TREATMENT
11,532
240 SF
48
21
SLEEPING
6,380
120 SF
22
TOTAL-SECOND LEVEL
99.662
509
STAIR 5
REQ. 17"
PROV. 44"
t1=1— ITA
17 f •• I -- —
ryl[-
u •;►: ■,
in
Ii -- ■ lid■ ♦♦ ♦♦ I II ■ -- -- -- ° 17
1
it ♦: I :♦: 1 1 /
w ♦i ♦ I • �e
II ���� 1 ♦i���l�i ♦i'�'♦�ili�i � yi
II ♦ ♦i♦ 3i ♦i♦♦♦ � l
Ili ♦ : ♦i ♦i ♦i♦�♦♦ :, .,, 1�1, ter, — —� _
�1. ..............�! Vii.- ♦�.-�WIN
►�♦��♦�♦�♦ �I
5 FIR
vi-
Ll
I► � I
I 1
I II 1 • - •
7�. IL��;,,• � I
-- I
II I r II 1 I.I r2•�
All I I /
Nil
STAIR 4
REQ. 17"
PROV. 44"
I /'/
/
� T � --ul U___L
T r:uRSes sTOrrJr
IMP
z�.icHrr.•J I unia� ,
r:u OFF
iff SMOK COMPARTMENT / 2
/ /,/ 13,580 S.F.
7C,• -OHCCM
I ✓ /�/ �PE �P FE
I
\ T
STAIR 1 ;� I
REQ. 17"
I ire I i /
PROV. 44' I � oR; cE T:, --cv
:; JiUT •1SROCM I "� STAIR 2
/ I1 REQ. 15"
I STAR 1 /Y�• I I y n %// �1 / \ I I I•
THEFT
1
LF
\ STa 3
TOILET . . . . . D. COOR
SEC. MD. EXAM ' ICIA HYSfCI CUNICI' OFFICE' ADMIN. CAROL
PBX ROOM BIGGS
h,ECHAMICAL SUPPORT OFFICE- •0 OFFICE• • • UPPO OFFICE
ROOM . . . . . . . . . .
. , . . . . ASSIST
JAN . . .
CLO EXISTING Pb
/.
/ I I LOUNGE WORKRM. / R SEARCH OFFICE i
'A TO LET TELEPHONE . . r . . . TLT + ✓
I RM. �-FDC I - —
/ LC / OFFICE
GK WI PARTME. C L PHYSICIANS
i 1 10,215 S.F. STOR.
Y //� ;may,// EXIST.
/CO R Y.�iY / / HECK R -
/ � /' �/� ECH �
F
FCChI /�
1 � 5CLEDHoLD110
b 3 �, •� I a �, I
ICY . . . . .
NNL I�H L / , /r-- X//
/
ECHO. .
ARTERIAL '
,�j,/' ECHO MA HLINE
Wool
TLT PACS/ �-=-'� / R LS -22
ECHO.REA
' / 1 RECEPT. .
',YORK/ ' "� / r ECHO
/ I G T. .4 J,C. SOIL j
ifs NIVL.
HEART CENTER �� YORKRM.
ELEC NNL• I NNL' MANAGER' " E
ROOM ARTERIAL .OFFICE I •q OLTE MO CE R OFFIC IUPE I,
�.�I I I I I I 1
PARTIAL SECOND FLOOR LIFE SAFETY PLAN
1/16" = V -0"
0 4' 8' 16' 32' 48' 64' 80'
GRAPHIC SCALE
i
Smith
Seckman
Reid, Inc.
600 West Hillsboro, Suite 300
-Deerfield Beach, FL 33441
- :(954) 421 -1260
_ FAX: (E-54) 421 -1466
- %wkv.s_r- Inc.com
Firm Certification – ES- 0000857
John E. Moulder PE – 33200
Michael A. Steward PE – 65701
SSR JOB # 1232030.0
H I<S
HKS ARCHITECTS, INC.
#AA F000119
1221 BRICKELL AVENUE
SUITE 1220
MIAMI, FL 33131
305 - 416 -6100
i
KEYPLAN
v /
W
co
J �
v
�' ~
M
�� wQ
O 0
U)
W _20
ICY)
vJ 2
co,
0
F- W
0z
U♦ W
W W
v /
W
DRAWN
CHECKED
DATE 11 -12 -12
REVISED
SHEET N0.
PARTIAL SECOND
FLOOR LIFE
SAFETY PLAN
LS -21 1
STAIR 3
II
♦/
- •
p� w
PROV. 44"
r�
I /'/
/
� T � --ul U___L
T r:uRSes sTOrrJr
IMP
z�.icHrr.•J I unia� ,
r:u OFF
iff SMOK COMPARTMENT / 2
/ /,/ 13,580 S.F.
7C,• -OHCCM
I ✓ /�/ �PE �P FE
I
\ T
STAIR 1 ;� I
REQ. 17"
I ire I i /
PROV. 44' I � oR; cE T:, --cv
:; JiUT •1SROCM I "� STAIR 2
/ I1 REQ. 15"
I STAR 1 /Y�• I I y n %// �1 / \ I I I•
THEFT
1
LF
\ STa 3
TOILET . . . . . D. COOR
SEC. MD. EXAM ' ICIA HYSfCI CUNICI' OFFICE' ADMIN. CAROL
PBX ROOM BIGGS
h,ECHAMICAL SUPPORT OFFICE- •0 OFFICE• • • UPPO OFFICE
ROOM . . . . . . . . . .
. , . . . . ASSIST
JAN . . .
CLO EXISTING Pb
/.
/ I I LOUNGE WORKRM. / R SEARCH OFFICE i
'A TO LET TELEPHONE . . r . . . TLT + ✓
I RM. �-FDC I - —
/ LC / OFFICE
GK WI PARTME. C L PHYSICIANS
i 1 10,215 S.F. STOR.
Y //� ;may,// EXIST.
/CO R Y.�iY / / HECK R -
/ � /' �/� ECH �
F
FCChI /�
1 � 5CLEDHoLD110
b 3 �, •� I a �, I
ICY . . . . .
NNL I�H L / , /r-- X//
/
ECHO. .
ARTERIAL '
,�j,/' ECHO MA HLINE
Wool
TLT PACS/ �-=-'� / R LS -22
ECHO.REA
' / 1 RECEPT. .
',YORK/ ' "� / r ECHO
/ I G T. .4 J,C. SOIL j
ifs NIVL.
HEART CENTER �� YORKRM.
ELEC NNL• I NNL' MANAGER' " E
ROOM ARTERIAL .OFFICE I •q OLTE MO CE R OFFIC IUPE I,
�.�I I I I I I 1
PARTIAL SECOND FLOOR LIFE SAFETY PLAN
1/16" = V -0"
0 4' 8' 16' 32' 48' 64' 80'
GRAPHIC SCALE
i
Smith
Seckman
Reid, Inc.
600 West Hillsboro, Suite 300
-Deerfield Beach, FL 33441
- :(954) 421 -1260
_ FAX: (E-54) 421 -1466
- %wkv.s_r- Inc.com
Firm Certification – ES- 0000857
John E. Moulder PE – 33200
Michael A. Steward PE – 65701
SSR JOB # 1232030.0
H I<S
HKS ARCHITECTS, INC.
#AA F000119
1221 BRICKELL AVENUE
SUITE 1220
MIAMI, FL 33131
305 - 416 -6100
i
KEYPLAN
v /
W
co
J �
v
�' ~
M
�� wQ
O 0
U)
W _20
ICY)
vJ 2
co,
0
F- W
0z
U♦ W
W W
v /
W
DRAWN
CHECKED
DATE 11 -12 -12
REVISED
SHEET N0.
PARTIAL SECOND
FLOOR LIFE
SAFETY PLAN
LS -21 1