12-1303R-006No m1w, 1310 ELECTRICAL SYMBOLS ALL SYMBOLS SHOWN MAY NOT APPEAR IN ALL DRAWINGS. SYMBOLS ARE SHOWN SCHEMATIC AND MAY NOT BE TO SCALE. LIGHTING FIRE ALARM DESCRIPTION DEVICE MM HT. SYMBOL DESCRIPTION 2'x2' / 2'x4' FLUORESCENT LIGHT FIXTURE ON NORMAL CIRCUIT. 2'x2' / 2'x4' FLUORESCENT LIGHT FIXTURE ON CRITICAL CIRCUIT. 2'x2' / 2'x4' FLUORESCENT LIGHT FIXTURE ON LIFE SAFETY CIRCUIT. 2'x4' FI UOI;EMT LIGHT FIXTURE W/INBQARD LAMPS ON LIFE SAFETY CIRCUIT AND OUTBOARD LAMPS ON NORMAL CIRCUIT. 2'x4' FLUORESCENT LIGHT FIXTURE W/INBOARD LAMPS ON NORMAL CIRCUIT AND OUTBOARD LAMPS ON CRITICAL CIRCUIT. 2'x4' FLUORESCENT LIGHT FIXTURE WANBOARD LAMPS ON CRITICAL V WALL MOUNTED FIXTURE ON NORMAL CIRCUIT. DRAWING TITLE WALL MOUNTED FIXTURE ON CRITICAL CIRCUIT. do WALL MOUNTED FIXTURE ON LIFE SAFETY CIRCUIT. 0 RECESSED /SUSPENDED DOWNLIGHT FIXTURE ON NORMAL CIRCUIT. 0 RECESSED /SUSPENDED DOWNLIGHT FIXTURE ON CRITICAL CIRCUIT. • RECESSED /SUSPENDED DOWINLIGHT FIXTURE ON LIFE SAM CIRCUIT. (� RECESSED DOWNLIGHT FIXTURE WITH WALL WASH TRIM. 8 9N T GAL ACE. ARROWS INDICATE CHEVRON DIRECTIONS. OR SWITCHES SYMBOL DESCRIPTION $ WALL SWITCH SPST, 20A. 120/277V $Z DOUBLE POLE TOGGLE SWITCH, 2OA/120/277V $3 3 -WAY WALL SWITCH, 20A. 120/277V $4 4 -WAY WALL SWITCH, 20A. 120/277V $D WALL Box DIMMER SWITCH $K KEY OPERATED WALL SWITCH $T WALL SWITCH WITH ADJUSTABLE COUNTDOWN TIMER $31) 3 -WAY WALL DIMMER SWITCH, 20A. 120/277V $3K 3-WAY, KEY OPERATED WALL SWITCH, 20A. 120/277V $me MOMENTARY WALL SWITCH, 20A. 120/277V $Ly LOW VOLTAGE WALL SWITCH $os WALL MOUNTED OCCUPANCY SENSOR SWITCH. REFER TO SPECIFICATIONS. WIRING DEVICES & POWER SYMBOL DESCRIPTION t3- SINGLE RECEPTACLE - 2OA/125V /2P/3W /G NEMA 5-20R DUPLEX RECEPTACLE - 2OA/125V/2P/3W/G NEMA 5-20R @ DUPLEX RECEPTACLE - 2OA/125V /2P/3W /G NEMA 5-20R DUPLEX RECEPTACLE GFI - 20A/125V/2P/3W/G NEMA 5-20R 7 _ DUPLEX RECEPTACLE GFI - 2DA/125V/2P/3W/G NEMA 5-20R EXISTING WIRING AS REQUIRED TO MAINTAIN CONTINUITY OF EXISTING CIRCUITRY SUCH THAT NO QUADRAPLEX RECEPTACLE TWO DUPLEX RUTS. UNDER ONE COVERPLAIE QUADRAPLEX RECEPTACLE TWO DUPLEX RCPTS. UNDER ONE COVERPLATE) •t 0 0 a 71 « 71 « 71 ,, -, 71 ,, -, `« 71 « 71 71 �« 71 « 71 V, « 2 13 1 « 71 48' AFF 4e AFF 48' AFF 4e AFF 48' AFF 48' AFF 48' AFF 48' AFF 48' AFF 48' AFF 48' AFF 48' AFF 1 « / ' 1 18' AFF U.N.O. 6' ABOVE COUNTERTOP OR CUSTOM MOUNTING HEIGHT 18' AFF U.N.O. 6' ABOVE COUNTERTOP OR CUSTOM MOUNTING HEIGHT 18' AFF U.N.O. 18' AFF U.N.O. 18' AFF U.N.O. +54' U.N.O. +54' U.N.O. AS REWIRED AS REWIRED AS REWIRED 48' AFF NOTE: DRAWING TITLE scaLE O DUPLEX RECEPTACLE - 2+ I' 7 5-20R FLOOR MOUNTED - FLUSH MOUNTED UNO 1 DUPLEX I RECEPTACLE MOUNTED « + MOUNTED 1 7 1 PARTIAL FIRST FLOOR PLAN - ELECTRICAL SPECIAL PURPOSE RECEPTACLE (NEMA NO. AS INDICATED) PRIOR TO BID AND SHALL NOTIFY THE ARCHITECT AND /OR ENGINEER IF A CONDITION EXISTS WHICH JUNCTION BOX SZE AND MOUN71NG AS REQUIRED NTS PREVENTS HIM/HER FROM ACCOMPLISHING THE WORK INDICATED AND INTENDED BY THESE DRAWINGS, DEVICE MTG. HT. NTS O O I; 31=n u + «-« :••l 21 `N « 7 -� M L r k 41RIL 7 1 F.11 0 7« l '� JIM&II 11 twfl;Ll 48•AFF MOTOR STARTER FVNR UNO; NUMBER INDICATES NEWA SRE uluu� TO THE BOTTOM OF THE LEN BELOW 6' FINISHED MANUAL MOTOR STARTER SWITCH WITH THERMAL 1 TR 1 1 1 PILO? ffl TO THE BOTTOM OF THE LEN cam z;0'!&fjjl 13 Wil): ■ •�7 r • 1 1 « «' « a7•w TO THE BOTTOM OF THE LENS REMOVE ALL DISCONNECT SWITCHES, CIRCUIT BREAKERS, MOTOR CONNECTIONS, STARTERS, ELECTRICAL - « 1 1 - 7• •� + •a 7 « 1 «•« •-1 171 171 71 mom�. '� -� �•� fill 1' - IiIiii INDICATED. ALSO, REMOVE ALL CONDUIT AND WIRE BACK TO POWER SOURCE. CIRCUIT SHALL REMAIN «/ 1 it 1`71 •t 0 0 a 71 « 71 « 71 ,, -, 71 ,, -, `« 71 « 71 71 �« 71 « 71 V, « 2 13 1 « 71 48' AFF 4e AFF 48' AFF 4e AFF 48' AFF 48' AFF 48' AFF 48' AFF 48' AFF 48' AFF 48' AFF 48' AFF 1 « / ' 1 18' AFF U.N.O. 6' ABOVE COUNTERTOP OR CUSTOM MOUNTING HEIGHT 18' AFF U.N.O. 6' ABOVE COUNTERTOP OR CUSTOM MOUNTING HEIGHT 18' AFF U.N.O. 18' AFF U.N.O. 18' AFF U.N.O. +54' U.N.O. +54' U.N.O. AS REWIRED AS REWIRED AS REWIRED 48' AFF THE SCOPE OF THE WORK SHALL INCLUDE THE FURNISHING AND INSTALLATION OF THE NECESSARY MATERIAL AND LABOR TO ACCOIN USIH THE WORK INDICATED BY THE DRAWINGS AND HEREIN SPECIFIED. ALL WORK BY CONTRACTOR SHALL CONFORM TO ALL APPLICABLE FEDERAL. STATE AND LOCAL BUILDING CODES AND STANDARDS INCLUDING BUT NOT LIMITED To- NOTE: DRAWING TITLE scaLE IT IS THE RESPONSIBILITY OF MECHANICAL, ELECTRICAL, PLUMBING AND FIRE PROTECTION GENERAL INFORMATION - ELECTRICAL NTS CONTRACTORS TO VISIT THE SITE AND EXAMINE IN DETAIL THE SCOPE OF WORK OF THIS PROJECT PARTIAL FIRST FLOOR PLAN - ELECTRICAL PRIOR TO BID AND SHALL NOTIFY THE ARCHITECT AND /OR ENGINEER IF A CONDITION EXISTS WHICH ELECTRICAL ONE -LINE, SCHEDULES NTS PREVENTS HIM/HER FROM ACCOMPLISHING THE WORK INDICATED AND INTENDED BY THESE DRAWINGS, DEVICE MTG. HT. NTS O O RD "40 HEAT DETECTOR CEILING OR WALL MOUNTED 48•AFF m II 1 104114 1:01i, SCOPE OF THE WORK. TO THE BOTTOM OF THE LEN BELOW 6' FINISHED ` 1 ; 111' « :1 1 1 « «7. \`,• «7 1 ''1 1 / TO THE BOTTOM OF THE LEN �i 6' BELOW FINISHED CEILING A. ALL EQUIPMENT SHOWN DASHED IS EXISTING TO BE REMOVED. CONTRACTOR SHALL DISCONNECT AND TO THE BOTTOM OF THE LENS REMOVE ALL DISCONNECT SWITCHES, CIRCUIT BREAKERS, MOTOR CONNECTIONS, STARTERS, ELECTRICAL 6' BELOW FINISHED CEILING mom�. '� -� �•� THE SCOPE OF THE WORK SHALL INCLUDE THE FURNISHING AND INSTALLATION OF THE NECESSARY MATERIAL AND LABOR TO ACCOIN USIH THE WORK INDICATED BY THE DRAWINGS AND HEREIN SPECIFIED. ALL WORK BY CONTRACTOR SHALL CONFORM TO ALL APPLICABLE FEDERAL. STATE AND LOCAL BUILDING CODES AND STANDARDS INCLUDING BUT NOT LIMITED To- 1. STATE OF FLORIDA 10. NATIONAL ELECTRICAI. SAFETY (RUDE 2. LIFE SAFETY CODE - NFPA 101 (2009) 11. REQUIREMENTS OF LOCAL UTILITY COMPANIES 3. UNDERWRITERS LABORATORIES. INC. PUBLICATIONS (UL) 12. NATIONAL. FIRE PROTECTION ASSMA71ON 72 (2007) 4. NATIONAL FIRE PROTECTION ASSOCIATION. (NFPA) 11 NATIONAL FIRE PROTECTION ASSOCIATION 99 (2005) 5. AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI) 14 THE STATE FIRE PREVENTION CODE, 4A60 (2010) 6. NATIONAL ELECTRICAL CODE - NFPA 70 (2008) 156 BUILDING CODE: FLORIDA BUILDING CODE (2010) 7. INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS (IEEE) 16. GUIDELINES FOR DESIGN AND CONSTRUCTION OF 8. NATIONAL ELECTRICAL MANUFACTURER'S ASSOCIATION (NEMA) HEALTHCARE FACILITIES (2010) 9. INTERNATIONAL POWER CABLE ENGINEER'S ASSOCIATION (IPCEA) 17. NFPA 110 (2005) INFEC11ON CONTROL • all .1 , q1;71 1' BID NOTE THE DRAWINGS DO NOT INDICATE EXISTING INSTALLATIONS OTHER THAN TO IDENTIFY MODIFICATIONS OR EXTENSIONS THERETO VISIT THE SITE AND ASCERTAIN THE EXISTING CONDITIONS. REVIEW CONSTRUCTION DETAILS OF THE EXISTING PORTION OF THE BUILDING DURING THE SITE INSPECTION. INCLUDE ALL WORK REQUIRED TO REMOVE OR MODIFY PORTIONS OF THE EXISTING INSTALLATION IN ORDER TO ACCOMMODATE THE NEW WORK. FAILURE TO COMPLY WITH THIS WILL NOT BE CONSIDERED GROUNDS FOR ADDITIONAL PAYMENT IN CONNECTION WITH REMOVING OR MODIFYING ANY PART OF THE EXISTING INSTALLATION OR INSTALLING ANY NEW OR TEMPORARY WORK. I. ALL CIRCUITS SHOWN ARE FOR REFERENCE PURPOSES ONLY. CONTRACTOR SHALL VERIFY ALL CIRCUITS TO BE REMOVED PRIOR TO COMMENCEMENT OF WORK. J. THE CONTRACT DOCUMENTS DO NOT PROPOSE TO SHOW ALL EXISTING SYSTEMS, MATERIAL OR EQUIPMENT. IT IS THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO OBTAIN DATA RELATED TO EXISTING CONDITIONS FROM EXISTING DOCUMENTS, NOTATIONS, PHOTOGRAPHS, SURVEYS AND OTHER OBSERVATIONS AT THE SITE K. REMOVE EXISTING WIRE, CONDUIT, EQUIPMENT, FIXTURES AND OTHER ITEMS TO PROVIDE ACCESS FOR WORK IN EXISTING FACILITIES. REINSTALL AND REFINISH ITEMS REMOVED, OR OTHERWISE DAMAGED, TO MATCH EXISTING AT NO ADDITIONAL COST TO OWNER. L WHERE EXISTING FUNCTIONS TO REMAIN IN USE ARE DISRUPTED, THEY SHALL BE FULLY RESTORED AFTER DISRUPTION, IN FULL COMPLIANCE WITH APPLICABLE CODES AND STANDARDS. M. MODIFY , REMOVE, OR RELOCATE MATERIALS AND ITEMS INDICATED ON THE DRAWINGS OR REQUIRED DUE TO THE DEMOLITION WORK. N. WORK JOINTLY WITH THE ARCHITECT, ESTABLISH AND MARK SALVAGE AND DEMOLITION ITEMS BEFORE COMMENCING WORK; REPORT ITEMS SCHEDULE FOR RELOCATION, REINSTALLATION OR REUSE, WHICH ARE FOUND TO BE IN DAMAGED CONDITION; AWAIT FURTHER INSTRUCTIONS FROM THE ARCHITECT BEFORE COMMENCING WITH WORK. 0. DEMOLITION EQUIPMENT, DEVICES AND MATERIAL SHALL BE REMOVED FROM THE SITE AND DISPOSED OF BY THE CONTRACTOR. SALVAGED EQUIPMENT AND DEVICES SHALL BE THE PROPERTY OF THE OWNER UNLESS NOTED OTHERWISE. P. MAKE RELOCATION NECESSITATED BY THE CONDITIONS AT THE SITE OR AS DIRECTED BY THE ARCHITECT, WITHOUT ADDITIONAL COST TO THE OWNER. REPAIR, REPLACE AND /OR RESTORE TO GOOD FUNCTIONAL CONDITION, EQUIPMENT, MATERIAL AND ITEMS SCHEDULE FOR RELOCATION, WHICH ARE DAMAGED DURING DISMANTLING OR REASSEMBLE OPERATIONS. PROVIDE NEW MATERIALS, FITTINGS AND APPURTENANCES REQUIRED TO COMPLETE THE RELOCATION AND TO RESTORE TO GOOD OPERATING ORDER. PERFORM THE RELOCATION WORK IN ACCORDANCE TO APPLICABLE CODES ASD STANDARDS, USING SKILLED WORKERS. Q. RELOCATING DEVICES: REMOVE AND REINSTALL IN LOCATIONS DESIGNATED BY THE ARCHITECT, TEMPERATURE CONTROL SYSTEM DEVICES. RELAYS, WIRE CONDUIT, FIXTURES, EQUIPMENT AND OTHER DEVICES REQUIRED FOR THE OPERATION OF THE VARIOUS SYSTEMS THAT ARE INSTALLED IN EXISTING TO BE REMOVED CONSTRUCTION. R. CONTRACTOR SHALL KEEP A CLEAN SET OF DRAWINGS ON THE JOB, NOTING DAILY, ALL CHANGES MADE IN THESE DRAWINGS IN CONNECTION WITH THE DEMOLITION PHASE, INCLUDING EXACT DIMENSIONED LOCATIONS OF ALL UNCOVERED EXISTING UTILITIES AND SHALL, WITH THIS, REQUEST FOR FINAL PAYMENT. TURN OVER A CLEAN, NEATLY MARKED SET OF REPRODUCIBLE MYLARS SHOWING 'EXISTING CONDITIONS' WORK TO THE ARCHITECT FOR SUBSEQUENT REVIEW AND TRANSMITTAL TO THE OWNER. CONTRACTOR SHALL NOTE ALL CONSTRUCTION CHANGES, DATE EACH AND LABEL 'AS- BUILTS' IN THE REVISION BLOCK ON THE DRAWINGS. CONTRACTOR SHALL ALSO FURNISH ONE SET OF 'AS- BUILTS' BLUEPRINTS. S. DEVICES SHOWN IN SOLID LIGHT LINES ARE EXISTING TO REMAIN. T. CONTRACTOR SHALL UPDATE ALL ELECTRICAL PANEL SCHEDULES AFFECTED BY THIS DEMOLITION. HAND WRITTEN SCHEDULES ARE NOT ACCEPTED. SCHEDULES SHALL BE TYPED OR COMPUTER GENERATED. GENERAL NOTES: FLOOR PLANS. A. CONTRACTOR SHALL PROVIDE AND INSTALL AN IDENTIFICATION NAMEPLATE FOR EACH ELECTRICAL EQUIPMENT /APPURTENANCES DEPICTING THE DESIGNATION INDICATED ON THE DRAWINGS. B. ALL EMPTY CONDUITS SYSTEMS SHALL CONTAIN A PULL WIRE FOR FUTURE PULLING OF CONDUCTORS. C. CONTRACTOR SHALL COORDINATE ALL REQUIRED ENERGY MANAGEMENT SYSTEM POINTS AND CONTACTS CONNECTIONS TO ENSURE THE COMPLETE AND PROPER OPERATION OF ALL SYSTEMS. D. THE CONTRACOTR SHALL COORDINATE WITH OTHER TRADES ALL NECESSARY WIRING AND CONNECTIONS REQUIRDE PRIOR TO PULLING CONDUCTOIRS INTO NEW CONDUITS. E. CONTRACTOR SHALL PROVIDE ALL EQUIPMENT AND MATERIAL NECESSARY FOR A COMPLETE AND OPERATIONAL INSTALLATION. F. CONTRACTOR SHALL NOT DISRUPT SERVICE TO ELECTRICAL APPURTENANCES TO REMAIN. G. CONTRACTOR SHALL CONNECT ALL NEW FIRE ALARM DEVICES, AS INDICATED ON DRAWINGS, TO EXISTING SYSTEM. CONTRACTOR SHALL PROVIDE NEW EXPANDABLE MODULES, CARDS, ETC. AS REQUIRED TO EXISTING SYSTEM, IN ORDER TO ACCOMODATE NEW DEVICES. H. IT IS THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO PROVIDE POWER AND CONNECT ALL NEW FIRE /SMOKE DAMPERS AND /OR MOTORIZE DAMPERS TO THE EXISTING FIRE ALARM SYSTEM. CONTRACTOR SHALL PROVIDE ALL EQUIPMENT AND MATERIAL NECESSARY FOR A COMPLETE AND OPERATIONAL INSTALLATION. REFER TO MECHANICAL DRAWINGS FOR EXACT LOCATION OF FIRE /SMOKE DAMPERS AND /OR MOTORIZE DAMPERS. I. ALL RECEPTACLES AND SWITCH PLATES SHALL HAVE ENGRAVED COVER PLATES TO INDICATE THE PANEL BOARD AND CIRCUIT NUMBERS POWERING THE DEVICE. J. ALL EMERGENCY RECEPTACLES AND LIGHT SWITCHES FACE PLATES SHALL BE RED. K. THE ELECTRICAL CONTRACTOR SHALL. VERIFY THAT THE AIC RATING OF ALL EXISTING CIRCUIT BREAKERS IN PANELS AFFECTED BY THIS PROJECT ARE ABOVE THE FAULT CURRENT VALUES PROVIDED IN THE SHORT CIRCUIT CALCULATIONS. IF THE AIC RATINGS ARE BELOW THE FAULT CURRENT VALUES, THE ELECTRICAL CONTRACTOR SHALL REPLACE ALL BREAKERS WITH NEW BREAKERS WITH AIC RATINGS ABOVE THE FAULT CURRENT VALUES. L CONTRACTOR SHALL UPDATE ALL ELECTRICAL PANEL SCHEDULES AFFECTED BY THIS PROJECT. HAND WRITTEN SCHEDULES ARE NOT ACCEPTED. SCHEDULES SHALL BE TYPED OR COMPUTER GENERATED. M. ALL NEW INSTALLATION SHALL COMPLY WITH NEC 210.4(8). CONTRACTOR SHALL PROVIDE A DEDICATED NEUTRAL FOR EACH CIRCUIT. N. WITHIN 30 DAYS AFTER DATE OF SYSTEM ACCEPTANCE, CONTRACTOR SHALL SUBMIT ASBUILT RECORD DRAWINGS OF THE ACTUAL INSTALLATIONS TO THE OWNER AND DESIGN TEAM INCLUDING ANY APPLICABLE MARKUPS TO THE RISER DIAGRAM. REFER TO SPECIFICATIONS FOR FURTHER REQUIREMENTS. 0. OPERATING MANUAL AND MAINTENANCE MANUAL SHALL BE PROVIDED TO THE BUILDING OWNER PRIOR TO OCCUPANCY, INCLUDING SUBMITTAL DATA STATING EQUIPMENT RATING AND SELECTED OPTIONS FOR EACH PIECE OF EQUIPMENT REQUIRING MAINTENANCE WITH CLEARLY IDENTIFIED REQUIRED ROUTINE MAINTENANCE ACTIONS, AND NAMES AND ADDRESSES OF AT LEAST ONE QUALIFIED SERVICE AGENCY. P. PROVIDE NO. 10 AWG CONDUCTORS FOR HOME RUNS ON 120 -VOLT. 20- AMPERE BRANCH CIRCUITS, WHERE THE CONDUCTOR LENGTH EXCEEDS 100 LINEAL FEET FROM PANELBOARD TO THE FIRST OUTLET. ELECTRICAL SHEET LIST NOTE: DRAWING TITLE scaLE IT IS THE RESPONSIBILITY OF MECHANICAL, ELECTRICAL, PLUMBING AND FIRE PROTECTION GENERAL INFORMATION - ELECTRICAL NTS CONTRACTORS TO VISIT THE SITE AND EXAMINE IN DETAIL THE SCOPE OF WORK OF THIS PROJECT PARTIAL FIRST FLOOR PLAN - ELECTRICAL PRIOR TO BID AND SHALL NOTIFY THE ARCHITECT AND /OR ENGINEER IF A CONDITION EXISTS WHICH ELECTRICAL ONE -LINE, SCHEDULES NTS PREVENTS HIM/HER FROM ACCOMPLISHING THE WORK INDICATED AND INTENDED BY THESE DRAWINGS, DEVICE MTG. HT. NTS SO NO ADDITIONAL COST IS INCURRED BY THE OWNER. AFTER CONTRACT IS AWARDED IT WILL BE ASSUMED THAT THE SITE WAS VISITED AND EXAMINED AND ALL PARTIES ARE IN AGREEMENT WITH THE 48•AFF SCOPE OF THE WORK. TO THE BOTTOM OF THE LEN BELOW 6' FINISHED DEMOLITION NOTES: TO THE BOTTOM OF THE LEN �i 6' BELOW FINISHED CEILING A. ALL EQUIPMENT SHOWN DASHED IS EXISTING TO BE REMOVED. CONTRACTOR SHALL DISCONNECT AND TO THE BOTTOM OF THE LENS REMOVE ALL DISCONNECT SWITCHES, CIRCUIT BREAKERS, MOTOR CONNECTIONS, STARTERS, ELECTRICAL 6' BELOW FINISHED CEILING PANELS, NURSE CALL SYSTEM EQUIPMENT, ETC. WITHIN THE AREA OF WORK, UNLESS OTHERWISE - INDICATED. ALSO, REMOVE ALL CONDUIT AND WIRE BACK TO POWER SOURCE. CIRCUIT SHALL REMAIN AS SPARE OR SPACE IN THEIR RESPECTIVE PANELS, OR BE REUSED AS INDICATED ON PANEL SCHEDULES. WHERE CONDUIT IS INACCESSIBLE, REMOVE CONDUCTORS AND CUT BACK CONDUIT FLUSH WITH SLAB OR WALL PATCH OPENING TO MATCH EXISTING FINISH. WHERE EXISTING WIRING EXTENDS - OUTSIDE OF THE AREA BY NATURE OF THE ORIGINAL INSTALLATION, CONTRACTOR SHALL MODIFY _ EXISTING WIRING AS REQUIRED TO MAINTAIN CONTINUITY OF EXISTING CIRCUITRY SUCH THAT NO EQUIPMENT TO REMAIN IS LEFT WITHOUT SERVICE. B. PRIOR TO BID, THE EXTENT AND UNDERSTANDING OF THE WORK TO BE PERFORMED SHALL BE _ CLEARLY ESTABLISHED SUCH THAT NO ADDITIONAL COSTS WILL BE INCURRED BY THE OWNER. ANY WORK, OTHER THAN AS DESCRIBED ON ANY ITEM OR SYSTEMS SHALL BE QUALIFIED WITHIN THE BID. C. CONTRACTOR SHALL EXERCISE EXTREME CAUTION DURING DEMOLITION WORK. EXISTING FEEDERS AND _ PANELS ARE SHOWN SCHEMATIC FOR REFERENCE PURPOSES ONLY. CONTRACTOR SHALL VERIFY IN _ FIELD ROUTING OF ALL EXISTING FEEDERS PRIOR TO DEMOLITION. D. CONTRACTOR SHALL PROVIDE TEMPORARY POWER, LIGHTING, COMM., ETC., WHERE REQUIRED DURING CEILING DEMOLITION AND CONSTRUCTION SCOPE OF WORK. - Ew ALL WORK SHALL BE PERFORMED BY A LICENSED ELECTRICAL CONTRACTOR AND SHALL BE - COORDINATED WITH OTHER TRADES. F. CONTRACTOR SHALL PROVIDE ALL REQUIRED INSURANCE FOR PROTECTION AGAINST PUBLIC LIABILITY FOR THE DURATION OF THE WORK. G. CONTRACTOR SHALL PAY FOR THE PERMITS, FEES do INSPECTIONS. H. CONTRACTOR SHALL NOT DISRUPT SERVICE TO ELECTRICAL APPURTENANCES TO REMAIN. 1. STATE OF FLORIDA 10. NATIONAL ELECTRICAI. SAFETY (RUDE 2. LIFE SAFETY CODE - NFPA 101 (2009) 11. REQUIREMENTS OF LOCAL UTILITY COMPANIES 3. UNDERWRITERS LABORATORIES. INC. PUBLICATIONS (UL) 12. NATIONAL. FIRE PROTECTION ASSMA71ON 72 (2007) 4. NATIONAL FIRE PROTECTION ASSOCIATION. (NFPA) 11 NATIONAL FIRE PROTECTION ASSOCIATION 99 (2005) 5. AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI) 14 THE STATE FIRE PREVENTION CODE, 4A60 (2010) 6. NATIONAL ELECTRICAL CODE - NFPA 70 (2008) 156 BUILDING CODE: FLORIDA BUILDING CODE (2010) 7. INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS (IEEE) 16. GUIDELINES FOR DESIGN AND CONSTRUCTION OF 8. NATIONAL ELECTRICAL MANUFACTURER'S ASSOCIATION (NEMA) HEALTHCARE FACILITIES (2010) 9. INTERNATIONAL POWER CABLE ENGINEER'S ASSOCIATION (IPCEA) 17. NFPA 110 (2005) INFEC11ON CONTROL • all .1 , q1;71 1' BID NOTE THE DRAWINGS DO NOT INDICATE EXISTING INSTALLATIONS OTHER THAN TO IDENTIFY MODIFICATIONS OR EXTENSIONS THERETO VISIT THE SITE AND ASCERTAIN THE EXISTING CONDITIONS. REVIEW CONSTRUCTION DETAILS OF THE EXISTING PORTION OF THE BUILDING DURING THE SITE INSPECTION. INCLUDE ALL WORK REQUIRED TO REMOVE OR MODIFY PORTIONS OF THE EXISTING INSTALLATION IN ORDER TO ACCOMMODATE THE NEW WORK. FAILURE TO COMPLY WITH THIS WILL NOT BE CONSIDERED GROUNDS FOR ADDITIONAL PAYMENT IN CONNECTION WITH REMOVING OR MODIFYING ANY PART OF THE EXISTING INSTALLATION OR INSTALLING ANY NEW OR TEMPORARY WORK. I. ALL CIRCUITS SHOWN ARE FOR REFERENCE PURPOSES ONLY. CONTRACTOR SHALL VERIFY ALL CIRCUITS TO BE REMOVED PRIOR TO COMMENCEMENT OF WORK. J. THE CONTRACT DOCUMENTS DO NOT PROPOSE TO SHOW ALL EXISTING SYSTEMS, MATERIAL OR EQUIPMENT. IT IS THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO OBTAIN DATA RELATED TO EXISTING CONDITIONS FROM EXISTING DOCUMENTS, NOTATIONS, PHOTOGRAPHS, SURVEYS AND OTHER OBSERVATIONS AT THE SITE K. REMOVE EXISTING WIRE, CONDUIT, EQUIPMENT, FIXTURES AND OTHER ITEMS TO PROVIDE ACCESS FOR WORK IN EXISTING FACILITIES. REINSTALL AND REFINISH ITEMS REMOVED, OR OTHERWISE DAMAGED, TO MATCH EXISTING AT NO ADDITIONAL COST TO OWNER. L WHERE EXISTING FUNCTIONS TO REMAIN IN USE ARE DISRUPTED, THEY SHALL BE FULLY RESTORED AFTER DISRUPTION, IN FULL COMPLIANCE WITH APPLICABLE CODES AND STANDARDS. M. MODIFY , REMOVE, OR RELOCATE MATERIALS AND ITEMS INDICATED ON THE DRAWINGS OR REQUIRED DUE TO THE DEMOLITION WORK. N. WORK JOINTLY WITH THE ARCHITECT, ESTABLISH AND MARK SALVAGE AND DEMOLITION ITEMS BEFORE COMMENCING WORK; REPORT ITEMS SCHEDULE FOR RELOCATION, REINSTALLATION OR REUSE, WHICH ARE FOUND TO BE IN DAMAGED CONDITION; AWAIT FURTHER INSTRUCTIONS FROM THE ARCHITECT BEFORE COMMENCING WITH WORK. 0. DEMOLITION EQUIPMENT, DEVICES AND MATERIAL SHALL BE REMOVED FROM THE SITE AND DISPOSED OF BY THE CONTRACTOR. SALVAGED EQUIPMENT AND DEVICES SHALL BE THE PROPERTY OF THE OWNER UNLESS NOTED OTHERWISE. P. MAKE RELOCATION NECESSITATED BY THE CONDITIONS AT THE SITE OR AS DIRECTED BY THE ARCHITECT, WITHOUT ADDITIONAL COST TO THE OWNER. REPAIR, REPLACE AND /OR RESTORE TO GOOD FUNCTIONAL CONDITION, EQUIPMENT, MATERIAL AND ITEMS SCHEDULE FOR RELOCATION, WHICH ARE DAMAGED DURING DISMANTLING OR REASSEMBLE OPERATIONS. PROVIDE NEW MATERIALS, FITTINGS AND APPURTENANCES REQUIRED TO COMPLETE THE RELOCATION AND TO RESTORE TO GOOD OPERATING ORDER. PERFORM THE RELOCATION WORK IN ACCORDANCE TO APPLICABLE CODES ASD STANDARDS, USING SKILLED WORKERS. Q. RELOCATING DEVICES: REMOVE AND REINSTALL IN LOCATIONS DESIGNATED BY THE ARCHITECT, TEMPERATURE CONTROL SYSTEM DEVICES. RELAYS, WIRE CONDUIT, FIXTURES, EQUIPMENT AND OTHER DEVICES REQUIRED FOR THE OPERATION OF THE VARIOUS SYSTEMS THAT ARE INSTALLED IN EXISTING TO BE REMOVED CONSTRUCTION. R. CONTRACTOR SHALL KEEP A CLEAN SET OF DRAWINGS ON THE JOB, NOTING DAILY, ALL CHANGES MADE IN THESE DRAWINGS IN CONNECTION WITH THE DEMOLITION PHASE, INCLUDING EXACT DIMENSIONED LOCATIONS OF ALL UNCOVERED EXISTING UTILITIES AND SHALL, WITH THIS, REQUEST FOR FINAL PAYMENT. TURN OVER A CLEAN, NEATLY MARKED SET OF REPRODUCIBLE MYLARS SHOWING 'EXISTING CONDITIONS' WORK TO THE ARCHITECT FOR SUBSEQUENT REVIEW AND TRANSMITTAL TO THE OWNER. CONTRACTOR SHALL NOTE ALL CONSTRUCTION CHANGES, DATE EACH AND LABEL 'AS- BUILTS' IN THE REVISION BLOCK ON THE DRAWINGS. CONTRACTOR SHALL ALSO FURNISH ONE SET OF 'AS- BUILTS' BLUEPRINTS. S. DEVICES SHOWN IN SOLID LIGHT LINES ARE EXISTING TO REMAIN. T. CONTRACTOR SHALL UPDATE ALL ELECTRICAL PANEL SCHEDULES AFFECTED BY THIS DEMOLITION. HAND WRITTEN SCHEDULES ARE NOT ACCEPTED. SCHEDULES SHALL BE TYPED OR COMPUTER GENERATED. GENERAL NOTES: FLOOR PLANS. A. CONTRACTOR SHALL PROVIDE AND INSTALL AN IDENTIFICATION NAMEPLATE FOR EACH ELECTRICAL EQUIPMENT /APPURTENANCES DEPICTING THE DESIGNATION INDICATED ON THE DRAWINGS. B. ALL EMPTY CONDUITS SYSTEMS SHALL CONTAIN A PULL WIRE FOR FUTURE PULLING OF CONDUCTORS. C. CONTRACTOR SHALL COORDINATE ALL REQUIRED ENERGY MANAGEMENT SYSTEM POINTS AND CONTACTS CONNECTIONS TO ENSURE THE COMPLETE AND PROPER OPERATION OF ALL SYSTEMS. D. THE CONTRACOTR SHALL COORDINATE WITH OTHER TRADES ALL NECESSARY WIRING AND CONNECTIONS REQUIRDE PRIOR TO PULLING CONDUCTOIRS INTO NEW CONDUITS. E. CONTRACTOR SHALL PROVIDE ALL EQUIPMENT AND MATERIAL NECESSARY FOR A COMPLETE AND OPERATIONAL INSTALLATION. F. CONTRACTOR SHALL NOT DISRUPT SERVICE TO ELECTRICAL APPURTENANCES TO REMAIN. G. CONTRACTOR SHALL CONNECT ALL NEW FIRE ALARM DEVICES, AS INDICATED ON DRAWINGS, TO EXISTING SYSTEM. CONTRACTOR SHALL PROVIDE NEW EXPANDABLE MODULES, CARDS, ETC. AS REQUIRED TO EXISTING SYSTEM, IN ORDER TO ACCOMODATE NEW DEVICES. H. IT IS THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO PROVIDE POWER AND CONNECT ALL NEW FIRE /SMOKE DAMPERS AND /OR MOTORIZE DAMPERS TO THE EXISTING FIRE ALARM SYSTEM. CONTRACTOR SHALL PROVIDE ALL EQUIPMENT AND MATERIAL NECESSARY FOR A COMPLETE AND OPERATIONAL INSTALLATION. REFER TO MECHANICAL DRAWINGS FOR EXACT LOCATION OF FIRE /SMOKE DAMPERS AND /OR MOTORIZE DAMPERS. I. ALL RECEPTACLES AND SWITCH PLATES SHALL HAVE ENGRAVED COVER PLATES TO INDICATE THE PANEL BOARD AND CIRCUIT NUMBERS POWERING THE DEVICE. J. ALL EMERGENCY RECEPTACLES AND LIGHT SWITCHES FACE PLATES SHALL BE RED. K. THE ELECTRICAL CONTRACTOR SHALL. VERIFY THAT THE AIC RATING OF ALL EXISTING CIRCUIT BREAKERS IN PANELS AFFECTED BY THIS PROJECT ARE ABOVE THE FAULT CURRENT VALUES PROVIDED IN THE SHORT CIRCUIT CALCULATIONS. IF THE AIC RATINGS ARE BELOW THE FAULT CURRENT VALUES, THE ELECTRICAL CONTRACTOR SHALL REPLACE ALL BREAKERS WITH NEW BREAKERS WITH AIC RATINGS ABOVE THE FAULT CURRENT VALUES. L CONTRACTOR SHALL UPDATE ALL ELECTRICAL PANEL SCHEDULES AFFECTED BY THIS PROJECT. HAND WRITTEN SCHEDULES ARE NOT ACCEPTED. SCHEDULES SHALL BE TYPED OR COMPUTER GENERATED. M. ALL NEW INSTALLATION SHALL COMPLY WITH NEC 210.4(8). CONTRACTOR SHALL PROVIDE A DEDICATED NEUTRAL FOR EACH CIRCUIT. N. WITHIN 30 DAYS AFTER DATE OF SYSTEM ACCEPTANCE, CONTRACTOR SHALL SUBMIT ASBUILT RECORD DRAWINGS OF THE ACTUAL INSTALLATIONS TO THE OWNER AND DESIGN TEAM INCLUDING ANY APPLICABLE MARKUPS TO THE RISER DIAGRAM. REFER TO SPECIFICATIONS FOR FURTHER REQUIREMENTS. 0. OPERATING MANUAL AND MAINTENANCE MANUAL SHALL BE PROVIDED TO THE BUILDING OWNER PRIOR TO OCCUPANCY, INCLUDING SUBMITTAL DATA STATING EQUIPMENT RATING AND SELECTED OPTIONS FOR EACH PIECE OF EQUIPMENT REQUIRING MAINTENANCE WITH CLEARLY IDENTIFIED REQUIRED ROUTINE MAINTENANCE ACTIONS, AND NAMES AND ADDRESSES OF AT LEAST ONE QUALIFIED SERVICE AGENCY. P. PROVIDE NO. 10 AWG CONDUCTORS FOR HOME RUNS ON 120 -VOLT. 20- AMPERE BRANCH CIRCUITS, WHERE THE CONDUCTOR LENGTH EXCEEDS 100 LINEAL FEET FROM PANELBOARD TO THE FIRST OUTLET. ELECTRICAL SHEET LIST ML DRAWING TITLE scaLE EO.00 GENERAL INFORMATION - ELECTRICAL NTS E1.00 PARTIAL FIRST FLOOR PLAN - ELECTRICAL E200 ELECTRICAL ONE -LINE, SCHEDULES NTS E3.00 ELECTRICAL SPECIFICATIONS NTS � Q � � c a� r �a O a fu t Akt0 tL c to LL o to .4uaq to in 0 co rym . � ° ro M` m E In n. M ^0 c n a� c 0 N :- �. rl 0 0 L X 4. O NNU a4°_ > xm Cl 12 ccW CD ° 0 0 a �0. N En o Utz C o Q COL a KEYPLAN Job NCI 412480.000 Dots 11 -05 -2012 t� • Shmt No- E0.00"' - �i KEYPLAN Job NCI 412480.000 Dots 11 -05 -2012 t� • Shmt No- E0.00"'