12-1303-006ELECTRICAL SYMBOLS ALL SYMBOLS SHOWN MAY NOT APPEAR IN ALL DRAWINGS SYMBOLS ARE SHOWN SCHEMATIC AND MAY NOT BE TO SCALE. LIGHTING 11 FIRE ALARM SYMBOL DESCRIPTION DEVICE MTG. HT. SYMBOL DESCRIPTION DEVICE MTG. HT. O 2'x2' / 2'x4' FLUORESCENT LIGHT FIXTURE ON NORMAL CIRCUIT. SEE SCHEDULE FIXTURE ❑F FIRE ALARM PULL STATION 48 AFF 18' AFF U.N.O. 2'x2' / 2'x4' FLUORESCENT LIGHT FIXTURE ON CRITICAL CIRCUIT. SEE FIXTURE SCHEDULE F 04 FIRE ALARM AUDIBLE /VISUAL SIGNAL BO' TO THE BOTTOM OF THE OR 6' BELOW FINISHED CEI • • 2'x2' / 2'x4' FLUORESCENT LIGHT FIXTURE ON LIFE SAFETY CIRCUIT. SEE FIXTURE SCHEDULE 04 FIRE ALARM AUDIBLE SIGNAL 80' TO THE BOTTOM OF THE OR 6' BELOW FINISHED q] Loc:.,GFI =lWp p • 2'x4' FLUORESCENT LIGHT FIXTURE W/INBOARD LAMPS ON LIFE SAFETY CIRCUIT AND OUTBOARD LAMPS ON NORMAL CIRCUIT. SEE FIXTURE SCHEDULE 04 FIRE ALARM VISUAL SIGNAL 80' TO THE BOTTOM OF THE OR 6' BELOW FINISHED CEII p 2'x4' FLUORESCENT LIGHT FIXTURE W/INBOARD LAMPS ON NORMAL CIRCUIT AND OUTBOARD LAMPS ON CRITICAL CIRCUIT SEE FIXTURE SCHEDULE ® FIRE ALARM SPRINKLER FLOW SWITCH - Q FQ 2'x4' FLUORESCENT LIGHT FIXTURE W/INBOARD LAMPS ON CRITICAL CIRCUIT AND OUTBOARD LAMPS ON CRITICAL CIRCUIT. SEE FIXTURE SCHEDULE ® FIRE ALARM SPRINKLER TAMPER SWITCH - C� V WALL MOUNTED FIXTURE ON NORMAL CIRCUIT. SCHEDULE ® FIRE ALARM SPRINKLER PRESSURE SWITCH - _ WALL MOUNTED FIXTURE ON CRITICAL. CIRCUIT. SCI FIXTUE 0 I- DD SMOKE DETECTOR CEILING OR WALL MOUNTED - C i FETY WALL MOUNTED FIXTURE ON LIFE SA CIRCUIT. SCHEDULEE OH Fe HEAT DETECTOR CEILING OR WALL MOUNTED - 0 RECESSED/SUSPENDED DOWNLIGHT FIXTURE ON NORMAL. CIRCUIT. SCHEDULE AS REWIRED DUCT SMOKE DETECTOR - ® RE /SUSPENDED DOWNLIGHT FIXTURE ON CRITICAL CIRCUIT. SEE SCIi�LE OS � FIRE ALARM SPEAKER CEILING OR WALL MOUNTED - BID NOTE RECESSED /SUSPENDED DOWNLIGHT FIXTURE ON LIFE SAFETY CIRCUIT. SEE FIXTURE SCHEDULE - SMOKE DOOR MECHANICAL HOLD OPEN, CONNECT TO FIRE ALARM SYSTEM - STUB 31e C. ABOVE ACCESSIBLE CEILING FROM OUTLET _ X/X/X RECESSED DOWNLIGHT FIXTURE WITH WALL WASH TRIM. SEE FIXTURE SCHEDULE FACP FIRE ALARM CONTROL PANEL - e Fe T CEILING OR WALL MOUNTED EXIT SIGN. SHADING INDICATES DOUBLE OR SINGAL FACE ARROWS INDICATE CHEVRON DIRECTIONS. SEE FIXTURE SCHEDULE FAAP FIRE ALARM ANNUNCIATOR PANEL - SWITCHES o FIRE ALARM SPEAKER CEILING ® FIRE ALARM RELAY - SYMBOL DESCRIPTION DEVICE MTG. HT. FR—TS-1 REMOTE TEST STATION - $ WALL SWITCH SPST, 20A, 120 /277V 48' AFF FATC FIRE ALARM TERMINAL CABINET - $Z DOUBLE POLE TOGGLE SWITCH, 2OA/120/277V 48' AFF $3 3 -WAY WALL SWITCH, 20A, 120/277V 48' AFF $4 4 -WAY WALL SWITCH, 20A, 120/277V 48' AFF $D WALL BOX DIMMER SWITCH 48' AFF $K KEY OPERATED WALL SWITCH 48' AFF $T WALL SWITCH WITH ADJUSTABLE COUNTDOWN TIMER 48' AFF $3D 3 -WAY WALL DIMMER SWITCH, 20A, 120/277V 48' AFF $3K 3 -WAY, KEY OPERATED WALL SWITCH, 20A, 120/277V 48' AFF $me MOMENTARY WALL SWITCH, 20A, 120/277V 48' AFF $w LOW VOLTAGE WALL SWITCH 48' AFF $os WALL MOUNTED OCCUPANCY SENSOR SWITCH. REFER TO SPECIFICATIONS. 48' AFF WIRING DEVICES & POWER SYMBOL I DESCRIPTION I DEVICE MTG. HT. U.N.O. 0 7_00e NOTE: IT IS THE RESPONSIBILITY OF MECHANICAL, ELECTRICAL, PLUMBING AND FIRE PROTECTION CONTRACTORS TO VISIT THE SITE AND EXAMINE IN DETAIL THE SCOPE OF WORK OF THIS PROJECT PRIOR TO BID AND SHALL NOTIFY THE ARCHITECT AND /OR ENGINEER IF A CONDITION EXISTS WHICH PREVENTS HIM/HER FROM ACCOMPLISHING THE WORK INDICATED AND INTENDED BY THESE DRAWINGS, SO NO ADDITIONAL COST IS INCURRED BY THE OWNER. AFTER CONTRACT IS AWARDED IT WILL BE ASSUMED THAT THE SITE WAS VISITED AND EXAMINED AND ALL PARTIES ARE IN AGREEMENT WITH THE SCOPE OF THE WORK. DEMOLITION NOTES: A. ALL EQUIPMENT SHOWN DASHED IS EXISTING TO BE REMOVED. CONTRACTOR SHALL DISCONNECT AND REMOVE ALL DISCONNECT SWITCHES, CIRCUIT BREAKERS, MOTOR CONNECTIONS, STARTERS, ELECTRICAL PANELS, NURSE CALL SYSTEM EQUIPMENT, ETC. WITHIN THE AREA OF WORK, UNLESS OTHERWISE INDICATED. ALSO, REMOVE ALL CONDUIT AND WIRE BACK TO POWER SOURCE. CIRCUIT SHALL REMAIN AS SPARE OR SPACE IN THEIR RESPECTIVE PANELS, OR BE REUSED AS INDICATED ON PANEL SCHEDULES. WHERE CONDUIT IS INACCESSIBLE, REMOVE CONDUCTORS AND CUT BACK CONDUIT FLUSH WITH SLAB OR WALL PATCH OPENING TO MATCH EXISTING FINISH. WHERE EXISTING WIRING EXTENDS OUTSIDE OF THE AREA BY NATURE OF THE ORIGINAL INSTALLATION, CONTRACTOR SHALL MODIFY EXISTING WIRING AS REQUIRED TO MAINTAIN CONTINUITY OF EXISTING CIRCUITRY SUCH THAT NO EQUIPMENT TO REMAIN IS LEFT WITHOUT SERVICE. B. PRIOR TO BID, THE EXTENT AND UNDERSTANDING OF THE WORK TO BE PERFORMED SHALL BE CLEARLY ESTABLISHED SUCH THAT NO ADDITIONAL COSTS WILL BE INCURRED BY THE OWNER. ANY WORK, OTHER THAN AS DESCRIBED ON ANY ITEM OR SYSTEMS SHALL BE QUALIFIED WITHIN THE BID. C. CONTRACTOR SHALL EXERCISE EXTREME CAUTION DURING DEMOLITION WORK. EXISTING FEEDERS AND PANELS ARE SHOWN SCHEMATIC FOR REFERENCE PURPOSES ONLY. CONTRACTOR SHALL VERIFY IN FIELD ROUTING OF ALL EXISTING FEEDERS PRIOR TO DEMOLITION. D. CONTRACTOR SHALL PROVIDE TEMPORARY POWER, LIGHTING, COMM., ETC., WHERE REQUIRED DURING DEMOLITION AND CONSTRUCTION SCOPE OF WORK. E. ALL WORK SHALL BE PERFORMED BY A LICENSED ELECTRICAL CONTRACTOR AND SHALL BE COORDINATED WITH OTHER TRADES. F CONTRACTOR SHALL PROVIDE ALL REQUIRED INSURANCE FOR PROTECTION AGAINST PUBLIC LIABILITY FOR THE DURATION OF THE WORK. G. CONTRACTOR SHALL PAY FOR THE PERMITS, FEES & INSPECTIONS. H. CONTRACTOR SHALL NOT DISRUPT SERVICE TO ELECTRICAL APPURTENANCES TO REMAIN. I. ALL CIRCUITS SHOWN ARE FOR REFERENCE PURPOSES ONLY. CONTRACTOR SHALL VERIFY ALL CIRCUITS TO BE REMOVED PRIOR TO COMMENCEMENT OF WORK. J. THE CONTRACT DOCUMENTS DO NOT PROPOSE TO SHOW ALL EXISTING SYSTEMS, MATERIAL OR EQUIPMENT. IT IS THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO OBTAIN DATA RELATED TO EXISTING CONDITIONS FROM EXISTING DOCUMENTS, NOTATIONS, PHOTOGRAPHS, SURVEYS AND OTHER OBSERVATIONS AT THE SITE. K. REMOVE EXISTING WIRE, CONDUIT, EQUIPMENT, FIXTURES AND OTHER ITEMS TO PROVIDE ACCESS FOR WORK IN EXISTING FACILITIES. REINSTALL AND REFINISH ITEMS REMOVED, OR OTHERWISE DAMAGED, TO MATCH EXISTING AT NO ADDITIONAL COST TO OWNER. L WHERE EXISTING FUNCTIONS TO REMAIN IN USE ARE DISRUPTED, THEY SHALL BE FULLY RESTORED AFTER DISRUPTION, IN FULL COMPLIANCE WITH APPLICABLE CODES AND STANDARDS. M. MODIFY , REMOVE, OR RELOCATE MATERIALS AND ITEMS INDICATED ON THE DRAWINGS OR REQUIRED DUE TO THE DEMOLITION WORK. N. WORK JOINTLY WITH THE ARCHITECT, ESTABLISH AND MARK SALVAGE AND DEMOLITION ITEMS BEFORE COMMENCING WORK; REPORT ITEMS SCHEDULE FOR RELOCATION, REINSTALLATION OR REUSE, WHICH ARE FOUND TO BE IN DAMAGED CONDITION; AWAIT FURTHER INSTRUCTIONS FROM THE ARCHITECT BEFORE COMMENCING WITH WORK. 0. DEMOU11ON EQUIPMENT, DEVICES AND MATERIAL SHALL BE REMOVED FROM THE SITE AND DISPOSED OF BY THE CONTRACTOR. SALVAGED EQUIPMENT AND DEVICES SHALL BE THE PROPERTY OF THE OWNER UNLESS NOTED OTHERWISE. P. MAKE RELOCATION NECESSITATED BY THE CONDITIONS AT THE SITE OR AS DIRECTED BY THE ARCHITECT, WITHOUT ADDITIONAL COST TO THE OWNER. REPAIR, REPLACE AND /OR RESTORE TO GOOD FUNCTIONAL CONDITION, EQUIPMENT, MATERIAL AND ITEMS SCHEDULE FOR RELOCATION, WHICH ARE DAMAGED DURING DISMANTLING OR REASSEMBLE OPERATIONS. PROVIDE NEW MATERIALS, FITTINGS AND APPURTENANCES REQUIRED TO COMPLETE THE RELOCATION AND TO RESTORE TO GOOD OPERATING ORDER. PERFORM THE RELOCATION WORK IN ACCORDANCE TO APPLICABLE CODES ASD STANDARDS, USING SKILLED WORKERS. Q. RELOCATING DEVICES: REMOVE AND REINSTALL IN LOCATIONS DESIGNATED BY THE ARCHITECT, TEMPERATURE CONTROL SYSTEM DEVICES, RELAYS, WIRE CONDUIT, FIXTURES, EQUIPMENT AND OTHER DEVICES REQUIRED FOR THE OPERATION OF THE VARIOUS SYSTEMS THAT ARE INSTALLED IN EXISTING TO BE REMOVED CONSTRUCTION. R. CONTRACTOR SHALL KEEP A CLEAN SET OF DRAWINGS ON THE JOB, NOTING DAILY, ALL CHANGES MADE IN THESE DRAWINGS IN CONNECTION WITH THE DEMOLITION PHASE, INCLUDING EXACT DIMENSIONED LOCATIONS OF ALL UNCOVERED EXISTING UTILITIES AND SHALL, WITH THIS, REQUEST FOR FINAL PAYMENT. TURN OVER A CLEAN, NEATLY MARKED SET OF REPRODUCIBLE MYLARS SHOWING 'EXISTING CONDITIONS' WORK TO THE ARCHITECT FOR SUBSEQUENT REVIEW AND TRANSMITTAL TO THE OWNER. CONTRACTOR SHALL NOTE ALL CONSTRUCTION CHANGES, DATE EACH AND LABEL 'AS- BUILTS' IN THE REVISION BLOCK ON THE DRAWINGS. CONTRACTOR SHALL ALSO FURNISH ONE SET OF 'AS- BUILTS' BLUEPRINTS. S. DEVICES SHOWN IN SOLID LIGHT LINES ARE EXISTING TO REMAIN. T. CONTRACTOR SHALL UPDATE ALL ELECTRICAL PANEL SCHEDULES AFFECTED BY THIS DEMOLITION. HAND WRITTEN SCHEDULES ARE NOT ACCEPTED. SCHEDULES SHALL BE TYPED OR COMPUTER GENERATED. NOTES: FLOOR A. CONTRACTOR SHALL PROVIDE AND INSTALL AN IDENTIFICATION NAMEPLATE FOR EACH ELECTRICAL EQUIPMENT /APPURTENANCES DEPICTING THE DESIGNATION INDICATED ON THE DRAWINGS. B. ALL EMPTY CONDUITS SYSTEMS SHALL CONTAIN A PULL WIRE FOR FUTURE PULLING OF CONDUCTORS. C. CONTRACTOR SHALL COORDINATE ALL REQUIRED ENERGY MANAGEMENT SYSTEM POINTS AND CONTACTS CONNECTIONS TO ENSURE THE COMPLETE AND PROPER OPERATION OF ALL SYSTEMS. D. THE CONTRACOTR SHALL COORDINATE WITH OTHER TRADES ALL NECESSARY WIRING AND CONNECTIONS REQUIRDE PRIOR TO PULLING CONDUCTOIRS INTO NEW CONDUITS. E. CONTRACTOR SHALL PROVIDE ALL EQUIPMENT AND MATERIAL NECESSARY FOR A COMPLETE AND OPERATIONAL INSTALLATION. F. CONTRACTOR SHALL NOT DISRUPT SERVICE TO ELECTRICAL APPURTENANCES TO REMAIN. G. CONTRACTOR SHALL CONNECT ALL NEW FIRE ALARM DEVICES, AS INDICATED ON DRAWINGS, TO EXISTING SYSTEM. CONTRACTOR SHALL PROVIDE NEW EXPANDABLE MODULES, CARDS, ETC. AS REQUIRED TO EXISTING SYSTEM, IN ORDER TO ACCOMODATE NEW DEVICES. H. IT IS THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO PROVIDE POWER AND CONNECT ALL NEW FIRE /SMOKE DAMPERS AND /OR MOTORIZE DAMPERS TO THE EXISTING FIRE ALARM SYSTEM. CONTRACTOR SHALL PROVIDE ALL EQUIPMENT AND MATERIAL NECESSARY FOR A COMPLETE AND OPERATIONAL INSTALLATION. REFER TO MECHANICAL DRAWINGS FOR EXACT LOCATION OF FIRE /SMOKE DAMPERS AND /OR MOTORIZE DAMPERS. I. ALL RECEPTACLES AND SWITCH PLATES SHALL HAVE ENGRAVED COVER PLATES TO INDICATE THE PANEL BOARD AND CIRCUIT NUMBERS POWERING THE DEVICE. J. ALL EMERGENCY RECEPTACLES AND LIGHT SWITCHES FACE PLATES SHALL BE RED. K. THE ELECTRICAL CONTRACTOR SHALL VERIFY THAT THE AIC RATING OF ALL EXISTING CIRCUIT BREAKERS IN PANELS AFFECTED BY THIS PROJECT ARE ABOVE THE FAULT CURRENT VALUES PROVIDED IN THE SHORT CIRCUIT CALCULATIONS. IF THE AIC RATINGS ARE BELOW THE FAULT CURRENT VALUES, THE ELECTRICAL CONTRACTOR SHALL REPLACE ALL BREAKERS WITH NEW BREAKERS WITH AIC RATINGS ABOVE THE FAULT CURRENT VALUES. L CONTRACTOR SHALL UPDATE ALL ELECTRICAL PANEL SCHEDULES AFFECTED BY THIS PROJECT. HAND WRITTEN SCHEDULES ARE NOT ACCEPTED. SCHEDULES SHALL BE TYPED OR COMPUTER GENERATED. M. ALL NEW INSTALLATION SHALL COMPLY WITH NEC 210.4(B). CONTRACTOR SHALL PROVIDE A DEDICATED NEUTRAL FOR EACH CIRCUIT. N. WITHIN 30 DAYS AFTER DATE OF SYSTEM ACCEPTANCE, CONTRACTOR SHALL SUBMIT ASBUILT RECORD DRAWINGS OF THE ACTUAL INSTALLATIONS TO THE OWNER AND DESIGN TEAM INCLUDING ANY APPLICABLE MARKUPS TO THE RISER DIAGRAM. REFER TO SPECIFICATIONS FOR FURTHER REQUIREMENTS. 0. OPERATING MANUAL AND MAINTENANCE MANUAL SHALL BE PROVIDED TO THE BUILDING OWNER PRIOR TO OCCUPANCY, INCLUDING SUBMITTAL DATA STATING EQUIPMENT RATING AND SELECTED OPTIONS FOR EACH PIECE OF EQUIPMENT REQUIRING MAINTENANCE WITH CLEARLY IDENTIFIED REQUIRED ROUTINE MAINTENANCE ACTIONS, AND NAMES AND ADDRESSES OF AT LEAST ONE QUALIFIED SERVICE AGENCY. P. PROVIDE NO. 10 AWG CONDUCTORS FOR HOME RUNS ON 120 -VOLT, 20- AMPERE BRANCH CIRCUITS, WHERE THE CONDUCTOR LENGTH EXCEEDS 100 LINEAL FEET FROM PANELBOARD TO THE FIRST OUTLET. ELECTRICAL SHEET LIST SINGLE RECEPTACLE - 20A/125V/2P/3W/G NEMA 5-20R 18' AFF U.N.O. ALE EO.00 DUPLEX RECEPTACLE - 2OA/125V/2P/3W/G NEMA 5-20R 18' AFF U.N.O. @ DUPLEX RECEPTACLE - 2OA/125V/2P/3W/G NEMA 5-20R 6' ABOVE COUNTERTOP OR CUSTOM MOUNTING HEIGHT E200 DUPLEX RECEPTACLE GFI - 2OA/125V/2P/3W/G NEMA 5-20R 18' AFF U.N.O. E3.00 DUPLEX RECEPTACLE GFI - 2OA/125V/2P/3W/G NEMA 5-20R 6' ABOVE COUNTERTOP OR CUSTOM MOUNTING HEIGHT 0 QUADRAPLEX RECEPTACLE TWO DUPLEX RCPTS. UNDER ONE COVERPLATE 18' AFF U.N.O. QUADRAPLEX RECEPTACLE TWO DUPLEX RCPTS. UNDER ONE COVERPLATE 6' ABOVE COUNTERTOP OR CUSTOM MOUNTING HEIGHT ,c,,GFI % "-W- pP DUPLEX RECEPTACLE GFI - 2OA/125V/2P/3W/G NEMA 5-20R WITH WEATHERPROOF ENCLOSURE 18' AFF U.N.O. Loc:.,GFI =lWp DUPLEX RECEPTACLE GFI - 2OA/125V/2P/3W/G NEMA 5-20R WITH WEATHERPROOF ENCLOSURE - ROOF MOUNTED 18' AFF U.N.O. O DUPLEX RECEPTACLE - 2OA/125V/2P/3W/G NEMA 5-20R FLOOR MOUNTED - FLUSH MOUNTED UNO _ DUPLEX RECEPTACLE - 2OA /125V /2P/3W /G NEMA 5-20R CEILING MOUNTED - FLUSH MOUNTED UNO _ ® SPECIAL PURPOSE RECEPTACLE (NEMA N0. AS INDICATED) ,B' AFF U.N.O. CODES AND STANDARDS Q FQ JUNCTION BOX - SIZE AND MOUNTING AS REQUIRED I DISTRIBUTION PANELBOARD _ THE SCOPE OF THE WORK SHALL INCLUDE THE FURNISHING AND INSTALLATION OF THE NECESSARY MATERIAL AND LABOR TO ACCOMPLISH THE WORK INDICATED BY THE DRAWINGS AND HEREIN SPECIFIED. ALL WORK BY CONTRACTOR SHALL CONFORM TO ALL APPLICABLE FEDERAL, STATE AND LOCAL BUILDING CODES AND STANDARDS INCLUDING BUT NOT LIMITED TO: 1. STATE OF FLORIDA 10. NATIONAL. ELECTRICAL SAFETY CODE 2 FETY LIFE SA CODE - NFPA 101 (2009) 11. REQUIREMENTS OF LOCAL UTILITY COMPANIES 3. UNDERWRITERS LABORATORIES, INC. PUBLICATIONS (UL) 12 NATIONAL FIRE PROTECTION ASSOCIATION 72 (2007) 4. NATIONAL FIRE PROTECTION ASSOCIATION. (NFPA) 13. NATIONAL FIRE PROTECTION ASSOCIATION 99 (2005) 5. AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI) 14. THE STATE FIRE PREVENTION CODE, 4A60 (2010) 6. NATIONAL ELECTRICAL CODE - NFPA 70 (2008) 15. BUILDING CODE: FLORIDA BUILDING CODE (2010) 7. INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS (IEEE) 16. GUIDELINES FOR DESIGN AND CONSTRUCTION OF 8. NATIONAL ELECTRICAL MANUFACTURER'S ASSOCIATION (NEMA) HEALTHCARE FACILITIES (2010) 9. INTERNATIONAL POWER CABLE ENGINEER'S ASSOCIATION (IPCEA) 17. WPA 110 (2005) !r7 208/120V PANELBOARD _ 480/277V PANELBOARD _ p 30/3 CIRCUIT BREAKER DISCONNECT SWITCH - THERMAL MAGNETIC IN NEMA 1 U.N.O.: AM INDICATED +54'' U.N.O. [EP 0J 1 DISCONNECT SWITCH - 30/3/*/1. INDICATES 30A, 3 -POLE, +54' U.N.O. ®2 MOTOR STARTER FVNR LINO; NUMBER INDICATES NEMA SIZE AS REQUIRED CB OJ MJ COMBINATION MOTOR CONTROLLER/bISCONNECT SWITCH AS REWIRED $w MANUAL MOTOR STARTER SWITCH WITH THERMAL OVERLOAD AND PILOT LIGHT AS REWIRED MOTOR _ �-D FM EMERGENCY POWER OFF BUTTON. FROM WALL MOUNTED - STUB 3/4! C. BOX ABOVE 48' AFF INFEC11ON CONTROL NOTE BID NOTE X,X,X THREE SINGLE POLE DEVICE CIRCUIT NUMBERS - CONTRACTOR SHALL OBTAIN A COPY OF THE INFECTION CONTROL RISK ASSESrIENT FOR THIS PROJECT. ALL WORK SHALL BE IN (X> LIANCE WITH THE REPORT. ALL WORK OUTSIDE THE SCOPE OF WORK AREA REWIRED FOR THIS PROJECT SHALL BE COORDINATED WITH OWNER AND BE IN COMPLIANCE WITH THE ICRA REPORT AND BE SUPERVISED BY THE OWNER'S REPRESENTATIVE. THE DRAWINGS DO NOT INDICATE EXISTING INSTALLATIONS OTHER THAN TO IDENTIFY MODIFICATIONS OR EXTENSIONS THERETO. VISIT THE SITE AND ASCERTAIN THE EXISTING CONDITIONS REVIEW CONSTRUCTION DETAILS OF THE EXISTING PORTION OF THE BUILDING DURING THE SITE INSPECTION. INCLUDE ALL WORK REWIRED TO REMOVE OR MODIFY PORTIONS OF THE EXISTING INSTALLATION IN ORDER TO ACCOMMODATE THE NEW WORK. FAILURE TO COMPLY WITH THIS WILL NOT BE CONSIDERED GROUNDS FOR ADDITIONAL PAYMENT IN CONNECTION WITH REMOVING OR MODIFYING ANY PART OF THE E)aSTING INSTALLATION OR INSTALLING ANY NEW OR TEMPORARY WORK X/X/X MULTI -POLE DEVICE CIRCUIT NUMBERS _ HOMERUN CONDUIT MINIMUM X' U.N.O. (NUMBER OF ARROWHEADS INDICATE QUANTITY OF /12 PHASE CONDUCTORS). REFER TO SPECIFICATIONS FOR FURTHER REQUIREMENTS. EACH 120V CIRCUIT SHALL BE PROVIDED WITH A DEDICATED NEUTRAL - CONDUIT CONCEALED IN WALLS OR ABOVE CEILING _ CONDUIT BELOW GRADE OR UNDER FLOOR _ CONDUIT EXPOSED - 0 7_00e NOTE: IT IS THE RESPONSIBILITY OF MECHANICAL, ELECTRICAL, PLUMBING AND FIRE PROTECTION CONTRACTORS TO VISIT THE SITE AND EXAMINE IN DETAIL THE SCOPE OF WORK OF THIS PROJECT PRIOR TO BID AND SHALL NOTIFY THE ARCHITECT AND /OR ENGINEER IF A CONDITION EXISTS WHICH PREVENTS HIM/HER FROM ACCOMPLISHING THE WORK INDICATED AND INTENDED BY THESE DRAWINGS, SO NO ADDITIONAL COST IS INCURRED BY THE OWNER. AFTER CONTRACT IS AWARDED IT WILL BE ASSUMED THAT THE SITE WAS VISITED AND EXAMINED AND ALL PARTIES ARE IN AGREEMENT WITH THE SCOPE OF THE WORK. DEMOLITION NOTES: A. ALL EQUIPMENT SHOWN DASHED IS EXISTING TO BE REMOVED. CONTRACTOR SHALL DISCONNECT AND REMOVE ALL DISCONNECT SWITCHES, CIRCUIT BREAKERS, MOTOR CONNECTIONS, STARTERS, ELECTRICAL PANELS, NURSE CALL SYSTEM EQUIPMENT, ETC. WITHIN THE AREA OF WORK, UNLESS OTHERWISE INDICATED. ALSO, REMOVE ALL CONDUIT AND WIRE BACK TO POWER SOURCE. CIRCUIT SHALL REMAIN AS SPARE OR SPACE IN THEIR RESPECTIVE PANELS, OR BE REUSED AS INDICATED ON PANEL SCHEDULES. WHERE CONDUIT IS INACCESSIBLE, REMOVE CONDUCTORS AND CUT BACK CONDUIT FLUSH WITH SLAB OR WALL PATCH OPENING TO MATCH EXISTING FINISH. WHERE EXISTING WIRING EXTENDS OUTSIDE OF THE AREA BY NATURE OF THE ORIGINAL INSTALLATION, CONTRACTOR SHALL MODIFY EXISTING WIRING AS REQUIRED TO MAINTAIN CONTINUITY OF EXISTING CIRCUITRY SUCH THAT NO EQUIPMENT TO REMAIN IS LEFT WITHOUT SERVICE. B. PRIOR TO BID, THE EXTENT AND UNDERSTANDING OF THE WORK TO BE PERFORMED SHALL BE CLEARLY ESTABLISHED SUCH THAT NO ADDITIONAL COSTS WILL BE INCURRED BY THE OWNER. ANY WORK, OTHER THAN AS DESCRIBED ON ANY ITEM OR SYSTEMS SHALL BE QUALIFIED WITHIN THE BID. C. CONTRACTOR SHALL EXERCISE EXTREME CAUTION DURING DEMOLITION WORK. EXISTING FEEDERS AND PANELS ARE SHOWN SCHEMATIC FOR REFERENCE PURPOSES ONLY. CONTRACTOR SHALL VERIFY IN FIELD ROUTING OF ALL EXISTING FEEDERS PRIOR TO DEMOLITION. D. CONTRACTOR SHALL PROVIDE TEMPORARY POWER, LIGHTING, COMM., ETC., WHERE REQUIRED DURING DEMOLITION AND CONSTRUCTION SCOPE OF WORK. E. ALL WORK SHALL BE PERFORMED BY A LICENSED ELECTRICAL CONTRACTOR AND SHALL BE COORDINATED WITH OTHER TRADES. F CONTRACTOR SHALL PROVIDE ALL REQUIRED INSURANCE FOR PROTECTION AGAINST PUBLIC LIABILITY FOR THE DURATION OF THE WORK. G. CONTRACTOR SHALL PAY FOR THE PERMITS, FEES & INSPECTIONS. H. CONTRACTOR SHALL NOT DISRUPT SERVICE TO ELECTRICAL APPURTENANCES TO REMAIN. I. ALL CIRCUITS SHOWN ARE FOR REFERENCE PURPOSES ONLY. CONTRACTOR SHALL VERIFY ALL CIRCUITS TO BE REMOVED PRIOR TO COMMENCEMENT OF WORK. J. THE CONTRACT DOCUMENTS DO NOT PROPOSE TO SHOW ALL EXISTING SYSTEMS, MATERIAL OR EQUIPMENT. IT IS THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO OBTAIN DATA RELATED TO EXISTING CONDITIONS FROM EXISTING DOCUMENTS, NOTATIONS, PHOTOGRAPHS, SURVEYS AND OTHER OBSERVATIONS AT THE SITE. K. REMOVE EXISTING WIRE, CONDUIT, EQUIPMENT, FIXTURES AND OTHER ITEMS TO PROVIDE ACCESS FOR WORK IN EXISTING FACILITIES. REINSTALL AND REFINISH ITEMS REMOVED, OR OTHERWISE DAMAGED, TO MATCH EXISTING AT NO ADDITIONAL COST TO OWNER. L WHERE EXISTING FUNCTIONS TO REMAIN IN USE ARE DISRUPTED, THEY SHALL BE FULLY RESTORED AFTER DISRUPTION, IN FULL COMPLIANCE WITH APPLICABLE CODES AND STANDARDS. M. MODIFY , REMOVE, OR RELOCATE MATERIALS AND ITEMS INDICATED ON THE DRAWINGS OR REQUIRED DUE TO THE DEMOLITION WORK. N. WORK JOINTLY WITH THE ARCHITECT, ESTABLISH AND MARK SALVAGE AND DEMOLITION ITEMS BEFORE COMMENCING WORK; REPORT ITEMS SCHEDULE FOR RELOCATION, REINSTALLATION OR REUSE, WHICH ARE FOUND TO BE IN DAMAGED CONDITION; AWAIT FURTHER INSTRUCTIONS FROM THE ARCHITECT BEFORE COMMENCING WITH WORK. 0. DEMOU11ON EQUIPMENT, DEVICES AND MATERIAL SHALL BE REMOVED FROM THE SITE AND DISPOSED OF BY THE CONTRACTOR. SALVAGED EQUIPMENT AND DEVICES SHALL BE THE PROPERTY OF THE OWNER UNLESS NOTED OTHERWISE. P. MAKE RELOCATION NECESSITATED BY THE CONDITIONS AT THE SITE OR AS DIRECTED BY THE ARCHITECT, WITHOUT ADDITIONAL COST TO THE OWNER. REPAIR, REPLACE AND /OR RESTORE TO GOOD FUNCTIONAL CONDITION, EQUIPMENT, MATERIAL AND ITEMS SCHEDULE FOR RELOCATION, WHICH ARE DAMAGED DURING DISMANTLING OR REASSEMBLE OPERATIONS. PROVIDE NEW MATERIALS, FITTINGS AND APPURTENANCES REQUIRED TO COMPLETE THE RELOCATION AND TO RESTORE TO GOOD OPERATING ORDER. PERFORM THE RELOCATION WORK IN ACCORDANCE TO APPLICABLE CODES ASD STANDARDS, USING SKILLED WORKERS. Q. RELOCATING DEVICES: REMOVE AND REINSTALL IN LOCATIONS DESIGNATED BY THE ARCHITECT, TEMPERATURE CONTROL SYSTEM DEVICES, RELAYS, WIRE CONDUIT, FIXTURES, EQUIPMENT AND OTHER DEVICES REQUIRED FOR THE OPERATION OF THE VARIOUS SYSTEMS THAT ARE INSTALLED IN EXISTING TO BE REMOVED CONSTRUCTION. R. CONTRACTOR SHALL KEEP A CLEAN SET OF DRAWINGS ON THE JOB, NOTING DAILY, ALL CHANGES MADE IN THESE DRAWINGS IN CONNECTION WITH THE DEMOLITION PHASE, INCLUDING EXACT DIMENSIONED LOCATIONS OF ALL UNCOVERED EXISTING UTILITIES AND SHALL, WITH THIS, REQUEST FOR FINAL PAYMENT. TURN OVER A CLEAN, NEATLY MARKED SET OF REPRODUCIBLE MYLARS SHOWING 'EXISTING CONDITIONS' WORK TO THE ARCHITECT FOR SUBSEQUENT REVIEW AND TRANSMITTAL TO THE OWNER. CONTRACTOR SHALL NOTE ALL CONSTRUCTION CHANGES, DATE EACH AND LABEL 'AS- BUILTS' IN THE REVISION BLOCK ON THE DRAWINGS. CONTRACTOR SHALL ALSO FURNISH ONE SET OF 'AS- BUILTS' BLUEPRINTS. S. DEVICES SHOWN IN SOLID LIGHT LINES ARE EXISTING TO REMAIN. T. CONTRACTOR SHALL UPDATE ALL ELECTRICAL PANEL SCHEDULES AFFECTED BY THIS DEMOLITION. HAND WRITTEN SCHEDULES ARE NOT ACCEPTED. SCHEDULES SHALL BE TYPED OR COMPUTER GENERATED. NOTES: FLOOR A. CONTRACTOR SHALL PROVIDE AND INSTALL AN IDENTIFICATION NAMEPLATE FOR EACH ELECTRICAL EQUIPMENT /APPURTENANCES DEPICTING THE DESIGNATION INDICATED ON THE DRAWINGS. B. ALL EMPTY CONDUITS SYSTEMS SHALL CONTAIN A PULL WIRE FOR FUTURE PULLING OF CONDUCTORS. C. CONTRACTOR SHALL COORDINATE ALL REQUIRED ENERGY MANAGEMENT SYSTEM POINTS AND CONTACTS CONNECTIONS TO ENSURE THE COMPLETE AND PROPER OPERATION OF ALL SYSTEMS. D. THE CONTRACOTR SHALL COORDINATE WITH OTHER TRADES ALL NECESSARY WIRING AND CONNECTIONS REQUIRDE PRIOR TO PULLING CONDUCTOIRS INTO NEW CONDUITS. E. CONTRACTOR SHALL PROVIDE ALL EQUIPMENT AND MATERIAL NECESSARY FOR A COMPLETE AND OPERATIONAL INSTALLATION. F. CONTRACTOR SHALL NOT DISRUPT SERVICE TO ELECTRICAL APPURTENANCES TO REMAIN. G. CONTRACTOR SHALL CONNECT ALL NEW FIRE ALARM DEVICES, AS INDICATED ON DRAWINGS, TO EXISTING SYSTEM. CONTRACTOR SHALL PROVIDE NEW EXPANDABLE MODULES, CARDS, ETC. AS REQUIRED TO EXISTING SYSTEM, IN ORDER TO ACCOMODATE NEW DEVICES. H. IT IS THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO PROVIDE POWER AND CONNECT ALL NEW FIRE /SMOKE DAMPERS AND /OR MOTORIZE DAMPERS TO THE EXISTING FIRE ALARM SYSTEM. CONTRACTOR SHALL PROVIDE ALL EQUIPMENT AND MATERIAL NECESSARY FOR A COMPLETE AND OPERATIONAL INSTALLATION. REFER TO MECHANICAL DRAWINGS FOR EXACT LOCATION OF FIRE /SMOKE DAMPERS AND /OR MOTORIZE DAMPERS. I. ALL RECEPTACLES AND SWITCH PLATES SHALL HAVE ENGRAVED COVER PLATES TO INDICATE THE PANEL BOARD AND CIRCUIT NUMBERS POWERING THE DEVICE. J. ALL EMERGENCY RECEPTACLES AND LIGHT SWITCHES FACE PLATES SHALL BE RED. K. THE ELECTRICAL CONTRACTOR SHALL VERIFY THAT THE AIC RATING OF ALL EXISTING CIRCUIT BREAKERS IN PANELS AFFECTED BY THIS PROJECT ARE ABOVE THE FAULT CURRENT VALUES PROVIDED IN THE SHORT CIRCUIT CALCULATIONS. IF THE AIC RATINGS ARE BELOW THE FAULT CURRENT VALUES, THE ELECTRICAL CONTRACTOR SHALL REPLACE ALL BREAKERS WITH NEW BREAKERS WITH AIC RATINGS ABOVE THE FAULT CURRENT VALUES. L CONTRACTOR SHALL UPDATE ALL ELECTRICAL PANEL SCHEDULES AFFECTED BY THIS PROJECT. HAND WRITTEN SCHEDULES ARE NOT ACCEPTED. SCHEDULES SHALL BE TYPED OR COMPUTER GENERATED. M. ALL NEW INSTALLATION SHALL COMPLY WITH NEC 210.4(B). CONTRACTOR SHALL PROVIDE A DEDICATED NEUTRAL FOR EACH CIRCUIT. N. WITHIN 30 DAYS AFTER DATE OF SYSTEM ACCEPTANCE, CONTRACTOR SHALL SUBMIT ASBUILT RECORD DRAWINGS OF THE ACTUAL INSTALLATIONS TO THE OWNER AND DESIGN TEAM INCLUDING ANY APPLICABLE MARKUPS TO THE RISER DIAGRAM. REFER TO SPECIFICATIONS FOR FURTHER REQUIREMENTS. 0. OPERATING MANUAL AND MAINTENANCE MANUAL SHALL BE PROVIDED TO THE BUILDING OWNER PRIOR TO OCCUPANCY, INCLUDING SUBMITTAL DATA STATING EQUIPMENT RATING AND SELECTED OPTIONS FOR EACH PIECE OF EQUIPMENT REQUIRING MAINTENANCE WITH CLEARLY IDENTIFIED REQUIRED ROUTINE MAINTENANCE ACTIONS, AND NAMES AND ADDRESSES OF AT LEAST ONE QUALIFIED SERVICE AGENCY. P. PROVIDE NO. 10 AWG CONDUCTORS FOR HOME RUNS ON 120 -VOLT, 20- AMPERE BRANCH CIRCUITS, WHERE THE CONDUCTOR LENGTH EXCEEDS 100 LINEAL FEET FROM PANELBOARD TO THE FIRST OUTLET. ELECTRICAL SHEET LIST DWG No. DRAWING TITLE ALE EO.00 GENERAL INFORMATION — ELECTRICAL NTS E1.00 PARTIAL FIRST FLOOR PLAN — ELECTRICAL 1/4' = 1' -0' E200 ELECTRICAL ONE —UNE, SCHEDULES NTS E3.00 ELECTRICAL SPECIFICATIONS NTS o _ 1 _ m, on N fn N c 111 __l rT 0) M - - N - - u- tD tD • • -- ---- - ----- -- o L m M° E Ln O_ M O L � = U N y tL0 CO • 00 NtnU 0. 420 0 xm CD ',so a o O W � � cn '� • N _ x: 1 _ it 0 •> N 2 �QZ REVISIONS MARK: REMARKS: Im HUH >w � 3: 2 cl) 0 Z W � _ m W � cl) G IS No. Lu /�(I 1� I I11 4 2012 KEYPLAN Job No: 412480.000 Date: 11 -05 -2012 Sheet TltIc GENERAL INFORMATION ELECTRICAL Sheet No: EO.00