12-1301-007EXTERIOR PRECAST WALL--r--- VEW 2 -WIRE, 30A, 120V WITH 15A =USE NEMA 3R GENERAL DUTY SQUARE -D SAFETY SWITCH WALL MOUNTED. REMARKS CONTRACTOR SHALL RUN 2 #14 AWG & 1 #14 GND IN Y2"C TO INDOOR UNIT PLUS 1#14 AWG FOR CONTROLS IN J "C NEW 36" HIGH, 4 "0 — CONC. FILLED BOLLARD (TYP. OF 2). NEW FLOOR MOUNTED SPLIT DX—/ AIR COOLED CONDENSING UNIT. ACCU -1 VISITOR PARKING GARAGE ENTRANCE PARTIAL FIRST FLOOR PLAN VISITOR PARKING GARAGE ELECTRICAL & COMMUNICATION ROOM NEW WORK SCALE- 11,V-T-V IIFhl rmp CUTLER HAMMFR PRIM (EXIST.) .IA I \1 niI1 nncA \/1 f%/4 r-nA Lill VOLTAGE 120/208V, 3 PH, 4W PANEL "EQU 99 AIC 1OKAIC MOUNTING SURFACE FED FROM: 480V PANEL LOCATION VISITOR PARKING ELEC. RM, VOLT AMP POLE TRIP CON DUI WIRE REMARKS CKT. NO. CKT. NO. REMARKS WIRE CON DUI TRIP POLE VOLT AMP - 1 20 - - ELEVATOR SUMP PUMP 1 2 RECEPTACLE COMM. RM. - - 20 1 - - 1 20 - - RECEPT. MAIN ELEC. RM. 3 4 SE GATES - - 20 1 - - 1 20 - - ELEVATOR SHUNT TRIP 5 6 SE GATES - - 20 1 - - 1 20 - - FIRE ALARM BELL 7 8 RECEPTACLE PENT HOUSE - - 20 1 - - 1 20 - - GEN. BATT. CHARGER 9 10 SECURITY CAMERAS - - 20 1 - - 1 20 - - LOBBY LIGHTS 11 12 SUMP PUMP FIRE PUMP RM. - - 20 1 - - 1 20 - - OBSTRUCTION LIGHTS 13 14 16 AHU PENT HOUSE - _ 70 2 - - 1 20 - - ELEVATOR 1 CAB LIGHTS 15 - 1 20 - - ELEVATOR 2 CAB LIGHTS 17 18 CALL STATIONS ELEV. - - 20 1 - - 1 20 - - FACP 19 20 NW GATES - - 20 1 _ - 1 20 - - GATES NW 21 22 NW GATES _ _ 20 1 _ - 1 20 - - SPARE 23 24 NW GATES - - 20 1 - - 1 20 - - SPARE 25 26 BOOTH - - 20 1 - - 1 20 - - SPARE 27 28 BOOTH - - 20 1 - SPACE 29 30 SIGN - - 20 1 - SPACE 31 32 SIGN - - 20 1 - - 2 20 - - RECEPT. COMM. ROOM 33 35 34 COMMUNICATION RM. C 3il 2 I 2! 20 1 11,680 36 SPACE SPACE 37 38 SPACE SPACE 39 40 SPACE SPACE 41 42 SPACE TOTAL DEMAND LOAD: 14.4 KVA x 125% (READINGS) + 1.68 KVA(LOAD ADDED) = 19.68 KVA I = 19.68 KVA = 55A 0 208V 0.360V NOTE: 01 CONTRACTOR SHALL PROVIDE /INSTALL NEW 1 -POLE, 20A CIRCUIT BREAKER HACR TYPE AND RUN NEW CONDUIT & WIRES FROM PANEL TO ACCU -1. VISITOR PAF" GARAGE LeVIE PANEL SCHEDULE NM M SCALE We%MV AC=A BUILDING KEY PLAN. WT TO SCALE 0 W A µ CD �LL- ck� CD° C) Z� =ZZ- -�C) Q�a�` MLdmV) 05: cry , a J Q U 9 W J La 0 J C7 O W c l t �'Y Y :i � p •• Q M Q cl U •• 4L Z G > c a� a JOB NO.: 212 -1040 O m. PLOT SIZE: as �(D L� � ® AS . NOTED I �w I CHECKED BY: F.A. d� CO �L- cq. q) . CA E La 4) I 'cau v0 Gn U d0 w � o I w N_ Q I o z 0 U a i 0 rz c o U •pa ck:a W A µ CD �LL- ck� CD° C) Z� =ZZ- -�C) Q�a�` MLdmV) 05: cry , a J Q U 9 W J La 0 J C7 O W Y U �- Q M Q cl U Z N_ > c nT- JOB NO.: 212 -1040 DATE : 10 -09 -12 PLOT SIZE: AS . NOTED DESIGNED /DRAWN BY: AN. CHECKED BY: F.A. SHEET No.: E -2 SHEET 2 OF 2 00