Loading...
12-1301-005AIR HANDLING UNIT SCHEDULE UNIT DESIGNATION AHU -1 QUANTITY REQUIRED 1 LOCATION C 0 I AT AV RM. p STATUS NEW ELECTRICAL SERVICE (VOLTS- PHASE - HERTZ) 115 -1 -60 QZo UNIT TYPE WALL HUNG =ZEN° WEIGHT (LBS.) 23.0 ELECTRICAL SERVICE (VOLTS- PHASE - HERTZ) TOTAL AIR (CFM) 261 (RECIRC.) SEASONAL ENERGY EFFICIENCY RATIO (S.E.E.R) 13.0 OUTSIDE AIR (CFM) NONE READ. RATED CAPACITY (BTU /HR) 12,500 EXTERNAL /TOTAL STATIC PRESSURE (INCHES, W.G.) --- / - -- � NUMBER. OF FANS zz FAN MOTOR HP - -- w �` NUMBER OF FANS 1 z FAN HP /WATTS - - - / - -- FAN SPEED (RPM) - -- FAN DRIVE TYPE DIRECT FAN MOTOR FLA /LRA .95/ - -- CONDENSER FAN FLA (AMPS) - -- STARTER TYPE /FURNISHED BY - -- REFRIGERANT TYPE R -41 OA a AMBIENT AIR TEMP. ('F) 95. ENT. COIL AIR TEMP., DB /WB ('F) 80/67 z FACE AREA (sq. ft.) o LVG. COIL AIR TEMP., DB /WB ('F) 55/54 o ROWS /F.P.I. v ROWS /FINS PER FOOT - - - / - -- 0°ac 00,vd z FACE AREA (SQ. FT.) - -- LIQUID CONNECTION (INCHES) 00 FACE VELOCITY (FPM) - -- SUCTION CONNECTION (INCHES) U GROSS TOTAL COOLING CAPACITY (BTUH) 9,500 � o NO. OF COMPRESSORS 1 GROSS SENSIBLE COOLING CAPACITY (BTUH) - -- AIR PRESSURE DROP (INCHES, W.G.) - -- con HORSEPOWER - -- q FILTER MEDIA TYPE - -- W F- Q o °' Cl J w No. /SIZES - -- 115-1-60 �` = 0 DEPTH (INCHES) - -- w a a°, PRESSURE DROP IN W.G. (DIRTY) - -- 0 MOTOR (RPM) c FILTER MEDIA TYPE - -- REFRIGERANT R -41 OA Z 0 J w No. /SIZES (LxWxH) - - - / - -- MODEL NUMBER 0 j' a W DEPTH (INCHES) 1 NOTES: 1.) UNIT SHALL COME FULLY FACTORY WIRED & READY TO OPERATE IN CONJUCTION WITH IT'S RESPECTIVE AIR HANDLING UNIT. CONTRACTOR SHALL PROVIDE /INSTALL A DEDICATED ELECTRICAL CONDUIT FOR CONTROL WIRING "ONLY ". M a PRESSURE DROP IN W.G. (DIRTY) .10 MANUFACTURER MITSUBISHI MODEL NO. MS -A09WA NOTES: 1.) UNIT SHALL COME FULLY FACTORY WIRED & READY TO OPERATE IN CONJUCTION WITH IT'S RESPECTIVE AIR COOLED CONDENSING UNIT. 2.) UNIT SHALL BE WALL HUNG AS PER MANUFACTURER'S INSTALLATION INSTRUCTIONS. 3.) UNIT SHALL COME FROM FACTORY WITH AN ADDITIONAL FILTER WHICH SHALL BE TURNED OVER TO OWNER. AIR COOLED CONDENSING UNIT SCHEDULE ; UNIT DESIGNATION ACCU -1 QUANTITY REQUIRED 1 LOCATION FLOOR MOUNTED p •• ,I NEAR ELECT. ROOM STATUS NEW QZo INTERLOCKED WITH AHU -1 =ZEN° WEIGHT (LBS.) 78.0 ELECTRICAL SERVICE (VOLTS- PHASE - HERTZ) 115-1-60 SEASONAL ENERGY EFFICIENCY RATIO (S.E.E.R) 13.0 RATED CAPACITY (BTU /HR) 12,500 ` A � NUMBER. OF FANS 1 w z FAN HP /WATTS - - - / - -- FAN DRIVE TYPE DIRECT a� CONDENSER FAN FLA (AMPS) - -- a AMBIENT AIR TEMP. ('F) 95. ka 02 oA o z FACE AREA (sq. ft.) - -- CIO CD il cq � 'a ccq* ' o ROWS /F.P.I. - - - / - -- 0°ac 00,vd 0 U O O U .0 LIQUID CONNECTION (INCHES) - -- N SUCTION CONNECTION (INCHES) - -- � o NO. OF COMPRESSORS 1 I w N_ con HORSEPOWER - -- U) W F- Q o °' Cl a ELECTRICAL SERVICE (VOLTS- PHASE - HERTZ) 115-1-60 M COMPRESSOR RLA /LRA 9.3/47.0 0 0 MOTOR (RPM) - -- REFRIGERANT R -41 OA Z 0 DESIGN MANUFACTURER MITSUBISHI MODEL NUMBER MU -A09WA NOTES: 1.) UNIT SHALL COME FULLY FACTORY WIRED & READY TO OPERATE IN CONJUCTION WITH IT'S RESPECTIVE AIR HANDLING UNIT. CONTRACTOR SHALL PROVIDE /INSTALL A DEDICATED ELECTRICAL CONDUIT FOR CONTROL WIRING "ONLY ". 2.) UNIT SHALL BE FLOOR MOUNTED. UNIT SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDED INSTALLATION PRACTICES. W O O Q V OF-NZ p •• ,I QZo O =ZEN° ON 0> Q ` A � a� q o 0 too ka 02 oA o V, I w cq CIO CD il cq � 'a ccq* ' .. 0°ac 00,vd 0 U O O U .0 v rn 0, N � o I w N_ W F- Q o °' Cl 0 Z 0 U Z 0 � FL °w V U o o W O O Q V OF-NZ QZo O =ZEN° ON 0> Q V) W J W NU 2 a P-lu FILE: JOB NO.: 212 -1040 DATE : 10 -09 -12 PLOT SIZE: AS NOTED DESIGNED /DRAWN BY: E. F. CHECKED BY: L.L. SHEET No.: M -4 SHEET 4 OF 4 .T 1, r