12-1301-004THERMAL EXPANSION DEVICE (HEAT PUMPS ONLY) DISTRIBUTOR INDOOR COIL LIQUID LINE (OPTIONAL ON STRAIGHT -COOL SYSTEMS ONLY) SLOPE LIQUID & SUCTION LINES DOWN TOWARDS OUTDOOR UNIT THERMAL EXPANSION DEVICE (HEAT PUMPS ONLY) SIGHT GLASS TX \ VALVE SYSTEM ONLY) FLITER /DRYER LIQUID LINE FLOOR MOUNTED OUTDOOR UNIT SUCTION LINE, INSULATE WITH 3 4" THICK ARMAFLEX INSULA ION. WALL SLEEVES NOTES: 1. PROVIDE OPERATION AND MAINTENANCE CLEARANCES AROUND ALL EQUIPMENT AS SPECIFIED BY THE MANUFACTURER. 2. OUTDOOR UNIT SHALL BE EQUIPPED WITH ISOLATION VALVES. 3. ALL NEW COPPER PIPING RUNNING HORIZONTALLY SHALL BE CEILING HUNG THRU HANGERS (ATTACHED TO CLG. THRU HILTI INSERTS). 4. ALL NEW COPPER PIPING RUNNING VERTICALLY ALONG WALLS SHALL BE ATTACHED TO WALLS BY USING GALV. STEEL UNISTRUT ASSEMBLIES/ HILTI BOLTS (3' -0" ON CNTRS.). REFRIGERANT PIPING ISOMETRIC NOT TO SCALE REFRIGERANT PIPING —� PIPE CLAMP, "UNISTRUT" #P2600 WITH CUSHION BETWEEN PIPE & CLAMP. SIZE TO MATCH PIPING. .ol� �� I �.00, SUPPORT CHANNEL, — UNISTRUT-1 5/8" WIDTH SERIES 01 ALL REFRIGERANT PIPING SHALL BE HARD COPPER, TYPE "K" WITH LONG RADIUS ELBOWS. O2 TRAPS (WHERE REQUIRED) SHALL BE SINGLE PIECE, WROUGHT COPPER. O3 INSULATE SUCTION LINE WITH 3/4" "ARMAFLEX" INSULATION FULL LENGTH. DO NOT SPLIT DURING INSULATION BUTT JOINTS WITH ARMAFLEX SEALANT, AND APPLY ARMAFLEX PRESERVATIVE ON ALL INSULATION ABOVE THE ROOF LINE. WHERE REFRIGERANT OR CONDENSATE PIPING RUNS THROUGH RETURN AIR PLENUMS, INSULATION SHALL BE FIRE - RATED ARMAFLEX "AP" 25/50. O ROUTING OF ALL REFRIGERANT PIPING SHALL BE PLUMB AND SHALL RUN TRUE WITH THE BUILDING LINES. HORIZONTAL RUNS OF SUCTION LINES OVER 25' SHALL BE PITCHED "ONE - HALF" BUBBLE TOWARD THE COMPRESSOR, FOR OIL RETURN. O5 SUPPORT OF ALL PIPING AT COMPRESSORS, CONDENSERS, AND AIR HANDLING UNITS SHALL BE AS SHOWN ABOVE. SUPPORT OF PIPING IN BETWEEN THE UNITS SHALL BE WITH STRAP MATERIAL, USING ARMAFLEX INSULATION AS SADDLES. NO METAL - TO - METAL CONTACT. O BRAZE REFRIGERANT PIPING WITH FLOW OF DRY NITROGEN DURING BRAZING. O7 SOLDER SHALL BE 15% SILVER "SIL - FOS" OR EQUAL. O CHANGE FILTER - DRIER CORES AFTER 30 DAYS OF OPERATION. TYPICAL REFRIGERANT PIPING SUPPOR NOT TO SCALE SEAL (ALL A� WITH 25/50 WEATHERPRO INSIDE OF 3/4" THICK, 25/50 RATED "ARMAFLEX" INSULATION. REFRIGERANT PIPE (COPPER)\ DETAIL ag S. ESCUTCHEON PLATE FOAMGLAS INSULATION SECTION BOTH SIDES OF WALL). INSIDE WALL. CONC. BLOCK WALL NOTES: 1 -) CONTRACTOR SHALL CORE -DRILL EXIST. EXTERIOR WALL SLIGHTLY LARGER THAN PIPE INSULATION AND INSTALL NEW SEC110N OF FOAMGLAS INSULATION AS SHOWN ABOVE. 2 -) NEW PIE ESCUTCHEONS SHALL BE ALL STAINLESS STEEL CONSTRUCTION. 3 -) LIQUID LINE DOES NOT REQUIRE ARMAFLEX INSULATION. TYPICAL REFRIGERANT PIPE THRU WALL DETAIL NOTTO SCALE W c� a �ck: N LL- Ck� -1, V oi-- c%iZri = :z �O �[ a o —�02 0 q 0 NCO N m �m (Ma C I-I � cl o� . �► CA v� a `' ag �C) o � o i pq N_ Q o I rn ° I 0 z 0 U U Z o U G3 it •w. � o __j W c� a �ck: �C) 0Q LL- Ck� V oi-- c%iZri = :z �O �[ a o —�02 �Zmc/i° N Q N Q H W D r Z 3 0 RM JOB NO.: 212 -1040 DATE : 10 -09 -12 PLOT SIZE: AS NOTED DESIGNED /DRAWN BY: E. F. CHECKED BY: L.L. SHEET No.: M -3