6TH FL. FIRE PROTECTION NEW WORK
SCALE: 1/4"=l'-0"
I
EXISTING A/S ZONE AND DRAIN
VALVE W/ TAMPER AND FLOW
VALVE CONTROLLING SUITE
KEY PLAN
FRE
JUAL_L: N.
PROTECT ON �, ,
I
1. THE FIRE PROTECTION SYSTEM INSTALLATION AND MATERIALS
SHALL BE IN COMPLIANCE WITH THE 2010 EDITION OF THE FLORIDA BUILDING CODE,
NFPA 13 REQUIREMENTS.
2. SPRINKLER SYSTEM TO BE INSTALLED BY A STATE CERTIFIED
FIRE PROTECTION CONTRACTOR. CONTRACTOR SHALL PROVIDE FLOW
TEST NO LATER THAN 60 DAYS OLD, SHOP DRAWINGS AND HYDRAULIC
CALCULATIONS IF REQUIRED BY THE AHJ.
3. CONTRACTOR SHALL COORDINATE WITH STRUCTURE, CEILING GRID AND
ELEVATION, AND OTHER MECHANICAL AND ELECTRICAL SERVICES
BEFORE FABRICATING AND INSTALLING SPRINKLER PIPING.
MAKE OFFSETS IN PIPING AS REQUIRED PER FIELD CONDITIONS.
MAINTAIN 6" CLEARANCE BETWEEN PIPING AND 1 AND 2 HOUR RATED
WALLS INCLUDING CORRIDOR WALLS.
4. ALL VALVES SHALL BE OF DOMESTIC MANUFACTURER, U.L. LISTED FOR
FIRE PROTECTION SERVICE AND RATED FOR 175 PSI WORKING PRESSURE.
PROVIDE U.L. LISTED/ FM APPROVED TAMPER SWITCHES, WHERE SHOWN,
AT CONTROL VALVE LOCATIONS. 1 1
5. SPRINKLER HEADS SHALL BE U.L. LISTED AND EQUIVALENT TO TYCO TY -FRB
5.6K, 155 DEG. QUICK RESPONSE UPRIGHT /PENDANT TYPE AND RATED FQR
175 PSI WORKING PRESSURE, CONTRACTOR SHALL PROVIDE AND TURN OVER
TO THE OWNER AT LEAST (6) SIX SPARE SPRINKLER HEADS OF EACH TYPE AND
TEMPERATURE RATING BEING INSTALLED,
6. CONTRACTOR SHALL PROVIDE FLUSHING CONNECTIONS WHERE SHOWN
ON PLANS. PROVIDE A DRAIN CONNECTION FOR ALL TRAPPED
SECTION OF PIPING
7. ABOVE GROUND PIPING SHALL BE U.L. LISTED SCHEDULE 10 BLACK STEEL PIPE.
CONTRACTOR SHALL MAKE ALL NECESSARY OFFSETS PER JOB CONDITION AND
INSTALL PIPING TIGHT TO STRUCTURE WHERE POSSIBLE. PIPING MATERIAL SHALL BE
LISTED FOR 175 PSI. UNDERGROUND PIPING ALL MATERIALS SHAL BE OF DOMESTIC
MANUFACTURER AND U.L. LISTED. FITTINGS SHALL BE MALLABLE IRON AND PROVIDED
BY THE SAME MANUFACTURER.
8. PRESSURE TEST ABOVE GROUND PIPING HYDROSTATICALLY AT 200 PSI FOR 2 HOURS
IN ACCORDANCE WITH NFPA 13. FLUSH OUT ALL PIPING IN ACCORDANCE WITH
NFPA 13, PROVIDE TYPED AND COMPLETED NFPA -13 TEST CERTIFICATE FOR
ABOVEGROUND PIPING.
APPLICABLE CODES
A. STATE, COUNTY, AND CITY HEALTH AND BUILDING CODES.
B. NFPA 13, 2007 EDITION.
C. NFPA 70, 2008 EDITION,
D. NFPA 72, 2007 EDITION.
E. NFPA 90A, 2009 EDITION.
F. OTHER NFPA CODES AS REFERENCED BY STANDARD CODES.
G. FLORIDA FIRE PREVENTION CODE, 2009 EDITION
H. FLORIDA ADMINSTRATIVE CODE CHAPTER 59A -3.
I. FGI GUIDELINES FOR CONSTRUCTION OF HEALTHCARE
FACILITIES 2010 EDITION
-- I . — , , V" �;,
AF'I'�t�1 f3tvolt&
C NI TR tCl C>TL ,Ei'n�.`rMr ra`r
urr:rr rFr�
Ali Mr �� z: cclura r °� r�t� �. Oit � rit ri t. p.
; t5f'BNj [n
Rprojed RII,,R/ 1
ALL DIMENSIONS
ARE
APPROXIMATE.
CONTRACTOR TO
VERIFY
DIMENSIONS IN
FIELD.
"TYPICAL" MEANS
THAT ALL SIMILAR
ITEMS ARE TO BE
HANDLES SIMILAR
TOTHE ONE
MARKED
"TYPICAL"
n--,
W
0
I---
O
Q
W
Q
O
0
Z
Buffo q D9'kgri(Dsruc 5
ASSOdA1VES
3824E Sddr4q RoAd
o FL 53021
COQ bwbbR DATE
®99or °�,o� ERTo ��041 04/30/12
f ®xAwm B9'
[N.I�I�t9101RR \,.lCe1V° �` ��0WN TL�L
IN00 i RATIO °
®® All > KA'tEN LZWARSECK, AIA
63 �LIC�NSE AR 13228
13 BUIkDING aIAGNQSTICS
ASS �A
LcE�� 0$ AAF
00114
5 6r ®dulabEOt
5A ,,o s9°°® F-2
f--- 0-)
W W 00 �
c~n I
o �r
rn- nn
�0
�LL
W
00Q
o—
�C�
Q0 :�i
Buffo q D9'kgri(Dsruc 5
ASSOdA1VES
3824E Sddr4q RoAd
o FL 53021
COQ bwbbR DATE
®99or °�,o� ERTo ��041 04/30/12
f ®xAwm B9'
[N.I�I�t9101RR \,.lCe1V° �` ��0WN TL�L
IN00 i RATIO °
®® All > KA'tEN LZWARSECK, AIA
63 �LIC�NSE AR 13228
13 BUIkDING aIAGNQSTICS
ASS �A
LcE�� 0$ AAF
00114
5 6r ®dulabEOt
5A ,,o s9°°® F-2