12-1139-024N r Q Q 0 4 U N 0 c 0 a m N O N Z KEY PLAN SCALE: N.T.S. DEMOLITION REMOVE EXISTING RECEPTACLES, TELEPHONE, SWITCHES, AND ANY ELECTRICAL DEVICES IN WALLS TO BE DEMOLISHED. RELOCATE ANY OF THESE DEVICES AS INDICATED OR REQUIRED BY THE DRAWINGS. PROVIDE ARCHITECT WITH AS —BUILT DRAWINGS OF FINAL INSTALLATION FOR RECORD PURPOSES. CONTRACTOR IS NOTIFIED THAT NOT ALL EXISTING DEVICES MAY HAVE BEEN INDICATED ON THE DRAWINGS AND THAT SOME EXISTING ELECTRICAL DEVICES MAY NOT HAVE BEEN SHOWN IN THEIR ACTUAL LOCATION. CONTRACTOR IS REQUIRED TO VISIT SITE AND BECOME FAMILIAR WITH THE EXISTING CONDITIONS PRIOR TO DETERMINING THE WORK THAT NEEDS TO BE ACCOMPLISHED AS PART OF HIS /HER BID, THE WORK SHALL INCLUDE THE FURNISHING OF ALL MATERIALS, CUTTING, EXTENDING, CONNECTING, REPAIRING, ADAPTING, AND OTHER WORK COINCIDENTAL HERETO, TOGETHER WITH SUCH TEMPORARY INSTALLATIONS AS MAY BE NECESSARY TO SATISFY THE DEMOLITION PROGRAM. APPROVAL SHALL BE SECURED FROM THE OWNER /ARCHITECT PRIOR TO CUTTING /DRILLING ANY STRUCTURAL SUPPORT. ALL BUILDING CONSTRUCTION AFFECTED BY THE REMOVAL, RELOCATION, INSTALLATION OF ANY PIECE OF EQUIPMENT SHALL BE REPAIRED AND FINISHED AS REQUIRED TO MATCH EXISTING CONDITIONS OR AS DIRECTED BY THE ARCHITECTURAL DRAWINGS, SPECIFICATIONS, OR OWNER'S REPRESENTATIVE. WHEN ELECTRICAL DEVICES ARE INSTALLED IN PARTITIONS OR CEILINGS TO BE REMOVED, THE ELECTRICAL CONTRACTOR SHALL DISCONNECT THEM UP TO THE NEXT OUTLET TO REMAIN OR BACK TO THE PANELBOARD. IF EXISTING TO REMAIN OUTLETS ARE FED THROUGH DEMOLISHED PARTITIONS OR CEILINGS, THE CIRCUIT SHALL BE REARRANGED TO MAINTAIN CIRCUIT CONTINUITY. WIRE SHALL BE REMOVED BACK TO SOURCE FROM INACCESSIBLE RACEWAYS NOT REUSED. INSTALL BLANK PLATES ON FLUSH OUTLETS NOT REUSED, PLATE COLOR SHALL MATCH ADJACENT SURFACE AS NEAR AS POSSIBLE IN FINISHED AREAS, ALL ELECTRICAL EQUIPMENT SHALL BE REMOVED FROM STRUCTURE TO BE REMOVED, ACCESSIBLE RACEWAYS, WIRES, BOXES, SWITCHES, AND OTHER ELECTRICAL ITEMS ASSOCIATED WITH THIS WORK SHALL BE REMOVED IF NOT REQUIRED FOR NEW EQUIPMENT TO CONTINUE IN SERVICE. ALL MATERIAL REMOVED SHALL BE DISPOSED OF AS DIRECTED BY OWNER. DURING THE EXECUTION OF THE WORK, ALL REQUIRED LOCATION, REROUTING, ETC., OF EXISTING EQUIPMENT AND SYSTEMS IN THE EXISTING BUILDING AREAS WHERE THE WORK IS REQUIRED, SHALL BE PERFORMED BY THE CONTRACTOR, AS INDICATED ON THE DRAWINGS, OR AS REQUIRED BY JOB CONDITIONS AND AS DETERMINED BY THE ARCHITECT IN THE FIELD, TO FACILITATE THE INSTALLATION OF THE NEW SYSTEMS. THE OWNER SHALL REQUIRE CONTINUOUS OPERATION OF THE EXISTING SYSTEMS, WHILE DEMOLITION, RELOCATION WORK OR NEW TIE —INS ARE PERFORMED. PRIOR TO ANY DEACTIVATION AND RELOCATION OF DEMOLITION WORK, ARRANGE A CONFERENCE WITH THE ARCHITECT AND THE OWNER'S REPRESENTATIVE IN THE FIELD TO INSPECT EACH OF THE ITEMS TO BE DEACTIVATED, REMOVED OR RELOCATED, CARE SHALL BE TAKEN TO PROTECT ALL EQUIPMENT DESIGNATED TO BE RELOCATED AND REUSED OR TO REMAIN IN OPERATION AND BE INTEGRATED WITH THE NEW SYSTEMS, ALL DEACTIVATION, RELOCATION, AND TEMPORARY TIE —INS SHALL BE PROVIDED BY THE CONTRACTOR. ALL DEMOLITION, REMOVAL AND THE LEGAL DISPOSAL OF DEMOLISHED MATERIALS OF SYSTEM DESIGNATED TO BE DEMOLISHED SHALL BE PROVIDED BY THE CONTRACTOR. THE OWNER RESERVES THE RIGHT TO INSPECT THE MATERIAL SCHEDULED FOR REMOVAL AND SALVAGE ANY ITEMS THEY DEEM USABLE AS SPARE PARTS. THE CONTRACTOR SHALL PERFORM ALL WORK IN PHASES AS DIRECTED BY THE ARCHITECT TO SUIT THE PROJECT PROGRESS SCHEDULE, AS WELL AS THE COMPLETION DATE OF THE PROJECT. LIMIT OF DEMOLITION DISCONNECT AND REMOVE ALL EXISTING ELECTRICAL FIXTURES, POWER AND SYSTEMS DEVICES, ETC. AND CONNECTIONS TO ALL EXISTING ELECTRICAL EQUIPMENT IN SCOPE OF WORK AREAS UNLESS OTHERWISE NOTED HERE OR ON OTHER DRAWINGS. REFER TO ELECTRICAL SPECIFICATION SECTION 26000 FOR OTHER REQUIREMENTS. ALL EXISTING RACEWAYS PASSING THROUGH THIS AREA FEEDING OTHER AREAS SHALL REMAIN INTACT AND OPERATIONAL. PROVIDE SUPPORTS FOR ALL EXISTING RACEWAYS IF THEY ARE NOT PROPERLY SUPPORTED AND OPERATIONAL. ALL OTHER RACEWAYS SHALL BE REMOVED. „ 6TH FL. EXISTING /DEMOLITION ELECTRICAL LAYOUT SCALE: 114`--V-0" project CA N 0i0p000W0 loop 0ii0100 mmavmm OLf10110L1AL Kim 1000 EAST SONN8E KV%$01TE /1 fO0T1,A00EN0ALE.fL0N10A0it0w i� 60•fi st0�00� �i�w.71l.00t� p dBdB '° ERTS. �010fE0 MO,. •• °•••, �08 00011 ►O�t/AE0 h (° �� °. • X63 ®A0 011 ALL DIMENSIONS ARE APPROXIMATE. CONTRACTOR TO VERILY DIMENSIONS IN FIELD. "TYPICAL" MEANS THAT ALL SIMILAR ITFMS ARE TO BE HANDLES SIMILAR TOTHE ONE MARKED "TYPICAL" _W IO I _ I V l LLJ U) lJ J O Z BukdNq ®u grins ks ASSOCOAVES 5824E SuuRUw,, RoAd Ho&/wood, IFIL $ $0211 954E - 9874206 PuKge u NumbER ODATE 11041 04/3012 DROM By AS SHOWN VN W A_AREN L. WARSECK, AIA LI ENSE # AR 13228 BI�LDING DIAGNOSTICS A9,43OCIATES, PA U ®ENSE # AAF000114 s NYumbu E­2 W W 00 � r > Oil D � 0 � O O LL_ W U) F O O N < F (_0 Q BukdNq ®u grins ks ASSOCOAVES 5824E SuuRUw,, RoAd Ho&/wood, IFIL $ $0211 954E - 9874206 PuKge u NumbER ODATE 11041 04/3012 DROM By AS SHOWN VN W A_AREN L. WARSECK, AIA LI ENSE # AR 13228 BI�LDING DIAGNOSTICS A9,43OCIATES, PA U ®ENSE # AAF000114 s NYumbu E­2