ELECTRICAL SYMBOLS LEGEND
NOT ALL SYMBOLS SHOWN ARE FOR THIS PROJECT
A FIXTURE TYPE
2X4 FLUORESCENT RECESSED FIXTURE
LP24 a-+*— SWITCH POLE TYPE
— PANEL /CIRCUIT NUMBER
2X4 FLUORESCENT RECESSED FIXTURE
DIAGONAL HALF SHADE INDICATES CRITCAL BRANCH
Q WALL MOUNTED FIXTURE
® UNDER CABINET LIGHT FIXTURE
L 2X2 FLUORESCENT RECESSED FIXTURE
-2X4 FLUORESCENT RECESSED FIXTURE
FULL SHADE INDICATES LIFESAFETY BRANCH
Nfr PENDANT MOUNTED LIGHT FIXTURE
CEILING OR WALL MOUNTED EXIT SIGNS WITH BATTERY BACKUP.
®OR� CHEVRONS & SHADED AREA DETERMINES THE DIRECTION
S LIGHT SWITCH
DM = DIMMER
3 = 3 -WAY
E = EMERGENCY RED SWITCH (CRITICAL LIGHTING)
ELECTRICAL SYMBOLS LEGEND: POWER
DUPLEX RECEPTACLE
qp ABOVE COUNTER RECEPTACLE
q) SIMPLEX RECEPTACLE
All
QUADRAPLEX RECEPTACLE
�-� DUCT HEATER
ELECTRICAL SYMBOLS LEGEND: SYSTEMS
V VOICE /DATA OUTLET.
VOICE JACKS AT TOP, (1) DATA JACKS, TYPICAL AT
BOTTOM, BLANK CENTER SPACE, MOUNT AT
18" AFF TO CENTER, UON.
PROVIDE & INSTALL 3/4" EMPTY CONDUIT
W /PULLSTRING
EMPTY CONDUITS, BACKBOXES & OUTLETS SHALL BE FURNISHED AND
INSTALLED IN ACCORDANCE WITH INFORMATION TECHNOLOGY DEPT.
REQUIREMENTS. CONDUITS SHALL TERMINATE ABOVE NEAREST
ACCESSIBLE CEILING,
Y THERMOSTAT; REFER TO MECHANICAL DWGS.
FLOOR OR WALL MOUNTED TV OUTLET
❑S CEILING SPEAKER
P = PAGING
AV = AUDIO /VISUAL
FA = FIRE ALARM
CAMERA SYSTEM
PAN /TILT /ZOOM SECURITY CAMERA
D = DOME CEILING MOUNTED
�p
MOTOR
KVA
MOTOR WITH DISCONNECT
E].I
MOTOR WITH DISCONNECT
O
WALL MOUNTED THERMOSTAT
LZR
REFER TO MECHANICAL DRAWINGS
MCB
WALL MOUNTED JUNCTION BOX
QOR
Y
CEILING (W /HARD CONNECTION) OR
CD = CANDELA
WALL MTD. JUNCTION BOX
DUPLEX RECEPTACLE
qp ABOVE COUNTER RECEPTACLE
q) SIMPLEX RECEPTACLE
All
QUADRAPLEX RECEPTACLE
�-� DUCT HEATER
ELECTRICAL SYMBOLS LEGEND: SYSTEMS
V VOICE /DATA OUTLET.
VOICE JACKS AT TOP, (1) DATA JACKS, TYPICAL AT
BOTTOM, BLANK CENTER SPACE, MOUNT AT
18" AFF TO CENTER, UON.
PROVIDE & INSTALL 3/4" EMPTY CONDUIT
W /PULLSTRING
EMPTY CONDUITS, BACKBOXES & OUTLETS SHALL BE FURNISHED AND
INSTALLED IN ACCORDANCE WITH INFORMATION TECHNOLOGY DEPT.
REQUIREMENTS. CONDUITS SHALL TERMINATE ABOVE NEAREST
ACCESSIBLE CEILING,
Y THERMOSTAT; REFER TO MECHANICAL DWGS.
FLOOR OR WALL MOUNTED TV OUTLET
❑S CEILING SPEAKER
P = PAGING
AV = AUDIO /VISUAL
FA = FIRE ALARM
CAMERA SYSTEM
PAN /TILT /ZOOM SECURITY CAMERA
D = DOME CEILING MOUNTED
�p
PUSH BUTTON
KVA
DR = DOOR RELEASE
KVAR
A = PANIC ALARM
ELECTRICAL SYMBOLS LEGEND: FIRE
� DCEILING MOUNTED SMOKE DETECTOR
LZR
WALL MOUNTED STROBE ONLY
MCB
L = LIGHT
MCC
WALL MOUNTED HORN /STROBE
MISC
CD = CANDELA
FS
CEILING MOUNTED HORN /STROBE
NC
CD = CANDELA
NCPS
WALL MOUNTED PULL STATION
F(V_
FIRE ALARM CONTROL PANEL
FAA
FIRE ALARM ANNUNCIATOR PANEL
FS
FLOW SWITCH
FT S-1
TAMPER SWITCH
FM-D-1
MOTION DETECTOR FOR AUTOMATIC DOOR
ML_ _@
`�
JUNCTION BOX FOR MAGNETC LOCKS
®J
RELAY
CR
CARD READER
4
DOOR MANUAL PUSH BUTTON
NOTES:
PNEUMATIC TUBE SYSTEM DIVERTER CONN.
1. EMPTY CONDUITS
AND BACKBOXES SHALL BE FURNISHED AND
INSTALLED
IN ACCORDANCE WITH NURSE CALL VENDOR
REQUIREMENTS. CONDUITS SHALL TERMINATE ABOVE NEAREST
ACCESSIBLE CEILING.
REF
REFRIGERATOR
SYMBOL LIST
SECURITY SYSTEM
SCR
SHORT CIRCUIT INTERRUPTING RATING
MOUNTING HEIGHTS SHALL BE AS INDICATED
SURGICAL LIGHT
Sc
GAS SERVICE COLUMN
UNLESS SHOWN OTHERWISE ON ELECTRICAL
SCRUB SINK
STE
STERILIZER
DRAWINGS OR ARCHITECTURAL ELEVATIONS
SPARE
GENERAL NOTES
1, CONTRACTOR SHALL REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT LOCATION OF
LIGHT FIXTURES AND ALL CEILING MOUNTED DEVICES.
2. CONTRACTOR SHALL PROVIDE AND INSTALL AN IDENTIFICATION NAMEPLATE FOR EACH ELECTRICAL
EQUIPMENT /APPURTENANCES DEPICTING THE DESIGNATION INDICATED ON THE DRAWINGS.
3. ALL EMPTY CONDUITS SYSTEMS SHALL CONTAIN A PULL WRE FOR FUTURE PULLING OF
CONDUCTORS.
4. CONTRACTOR SHALL COORDINATE ALL REQUIRED ENERGY MANAGEMENT SYSTEM POINTS AND
CONTACTS CONNECTIONS TO ENSURE THE COMPLETE AND PROPER OPERATION OF ALL SYSTEMS.
5. CONTRACTOR SHALL PROVIDE AND INSTALL A 1" CONDUIT W /PULL WRE FROM EACH WALL MOUNTED
TELEPHONE AND /OR DATA OUTLET STUB UP 6- ABOVE FINISHED CEILING,
6. THE CONTRACTOR SHALL COORDINATE WITH OTHER TRADES ALL NECESSARY WRING AND
CONNECTIONS REQUIRDE PRIOR TO PULLING CONDUCTOIRS INTO NEW CONDUITS.
7. CONTRACTOR SHALL PROVIDE ALL EQUIPMENT AND MATERIAL NECESSARY FOR A COMPLETE AND
OPERATIONAL INSTALLATION.
8. CONTRACTOR SHALL CONNECT ALL NEW FIRE ALARM DEVICES, AS INDICATED ON DRAWINGS+ TO
EXISTING SYSTEM, CONTRACTOR SHALL PROVIDE NEW EXPANDABLE MODULES, CARDS, ETC, 'AS
REQUIRED, IN ORDER TO ACCOMODATE NEW DEVICES.
9. ALL RECEPTACLES AND SWITCH PLATES SHALL HAVE ENGRAVED COVER PLATES TO INDICATE THE
PANEL BOARD AND CIRCUIT NUMBERS POWERING THE DEVICE.
10. AIC RATING OF CIRCUIT BREAKERS SHALL MATCH PANEL IN WHICH INSTALLED.
11. CONTRACTOR SHALL UPDATE ALL ELECTRICAL PANEL SCHEDULES AFFECTED BY THIS PROJECT.
HAND WRITTEN SCHEDULES ARE NOT ACCEPTED. SCHEDULES SHALL BE TYPED OR COMPUTER
GENERATED.
12, IT IS THE RESPONSIBILITY OF MECHANICAL, ELECTRICAL, PLUMBING AND FIRE PROTECTION
CONTRACTORS TO VISIT THE SITE AND EXAMINE IN DETAIL THE SCOPE OF WORK OF THIS PROJECT
AND SHALL NOTIFY THE ARCHITECT AND /OR ENGINEER IF A CONDITION EXISTS WHICH PREVENTS
HIM /HER FROM ACCOMPLISHING THE WORK INDICATED AND INTENDED BY THESE DRAWNGS, SO
NO ADDITIONAL COST IS INCURRED BY THE OWNER. AFTER CONTRACT IS AWARDED IT WILL BE
ASSUMED THAT THE SITE WAS VISITED AND EXAMINED AND ALL PARTIES ARE IN AGREEME T WITH
THE SCOPE OF THE WORK.
13. IT IS THE RESPONSIBILITY OF THE ELECTRICAL, MECHANICAL, PLUMBING, AND FIRE PROTECTION
CONTRACTORS TO COORDINATE THE INSTALLATION OF ALL EQUIPMENT, DEVICES, ETC WITH OTHER
TRADES, INCLUDING BUT NOT LIMITED TO: SPRINKLER HEADS, HVAC DIFFUSERS, LIGHT FIXTURES,
SMOKE DETECTORS, ETC.
14, THE ARCHITECTURAL, MECHANICAL, PLUMBING AND FIRE PROTECTION DRAWINGS ARE INHERENTLY
PART OF THESE COMPLETE SET OF CONTRACT DOCUMENTS.
15. LIGHT SWITCHES SHALL BE MOUNTED 48 INCHES ABOVE FINISHED FLOOR
TO CENTER LINE OF DEVICE, UNLESS OTHERWISE NOTED,
16. RECEPTACLES SHALL BE LOCATED 18 INCHES ABOVE FINISHED FLOOR TO
CENTER LINE OF DEVICE, UNLESS OTHERWISE NOTED. ABOVE COUNTER RECEPTACLES
SHALL BE MOUNTED 6 °ABOVE BACK SPLASH TO CENTERLINE OF DEVICE.
17. THE EQUIPMENT GROUNDING TERMINAL BARS OF THE NORMAL AND ESSENTIAL ELECTRICAL
SYSTEM PANELBOARDS SERVING THE SAME PATIENT VICINITY SHALL BE BONDED TOGETHER,
WITH AN INSULATED, CONTINUOUS, COPPER CONDUCTOR NOT SMALLER THAN NUMBER 10,
18. EQUIPMENT SHALL BE OF MATERIALS SUITABLE FOR AND RATED FOR THE ENVIRONMENT
IN WHICH THEY ARE TO BE INSTALLED,
19. WORKING CLEARANCES FOR ELECTRICAL EQUIPMENT SHALL BE IN COMPLIANCE WITH
NEC 110.
20. PATIENT CARE AREAS SHALL BE INSTALLED & PROVIDED WITH GROUNDING IN ACCORDANCE
WITH NEC 517.2 & 517.13(A) & 517.13(B).
21. WHEN ELECTRICAL BOXES ARE LOCATED IN VERTICAL FIRE RESISTIVE ASSEMBLIES,
(CLASSIFIED AS FIRE /SMOKE AND SMOKE PARTITIONS), THEY SHALL BE INSTALLED
WITHOUT AFFECTING THE FIRE CLASSIFICATION. ALL OF THE FOLLOWING CONDITIONS
SHALL BE MET:
A. ALL ELECTRICAL BOXES SHALL BE METALLIC.
B, BOX OPENING SHALL OCCUR ONLY ON ONE SIDE OF FRAMING SPACE.
C. BOX OPENING SHALL NOT EXCEED 16 SQUARE INCHES.
D. ALL CLEARANCES BETWEEN OUTLET BOX AND GYPSUM BOARD SHALL BE COMPLETELY
FILLED WITH JOINT COMPOUND (OR OTHER APPROVED MATERIAL).
E. PROVIDE A WALL AROUND OUTLETS LARGER THAN 16 SQUARE INCHES. THE INTEGRITY
OF THE WALL RATING SHALL BE MAINTAINED.
F. THE TOTAL AGGREGATE SURFACE AREA OF THE BOXES SHALL NOT EXCEED 100 SQUARE
INCHES PER 100 SQUARE FEET.
G. OUTLET BOXES LOCATED ON OPPOSITE SIDES OF FIRE RESISTIVE ASSEMBLIES SHALL
BE SEPARATED BY A MINIMUM HORIZONTAL DISTANCE OF 24 INCHES.
H. OUTLET BOXES SHALL BE SECURELY FASTENED TO WALL FRAMING MEMBERS
I. THE OPENING IN THE GYPSUM BOARD FACING SHALL BE CUT NOT TO EXCEED 1/8 INCH
BETWEEN THE EDGES OF THE OUTLET BOX AND THE EDGES OF THE OPENING.
22. NON- METALLIC RACEWAYS SHALL NOT BE USED TO SERVE ANY PATIENT CARE SPACE. ALL
WRING SHALL BE MECHANICALLY PROTECTED BY INSTALLATION IN METALLIC RACEWAYS,
23. ALL DEVICES SHALL BE MOUNTED VERTICAL, UNLESS OTHERWISE NOTED.
24, ALL RECEPTACLES SHALL BE MOUNTED SUCH THAT THE GROUND PIN IS MOUNTED UP.
25, THE NUMBER OF ARROWHEADS ON THE HOMERUNS DENOTES THE NUMBER OF CIRCUITS.
ABBREVIATIONS
A AMPERES
AF AMPERE FRAME (CIRCUIT BREAKER RATING)
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AIC AMPERE INTERRUPTING CAPACITY
AL ALUMINUM
ARCH ARCHITECT
AT AMPERE TRIP (CIRCUIT BREAKER RATING)
ATS AUTOMATIC TRANSFER SWITCH.
AUD AUDIOMETER BOX CONNECTION
AWG AMERICAN WIRE GAUGE
BIN X -RAY FILM BIN
BLDG BUILDING
C CONDUIT
C. B. CIRCUIT BREAKER
C. T. CURRENT TRANSFORMER
CAB CABINET, WARMING
CAM CAMERA
CAT CATALOG
CIR CIRCUIT
CLM COLUMN
CU COPPER
LL DELTA
DWG DRAWING
EM WIRED ON EMERGENCY CIRCUIT
EC EMPTY CONDUIT
EX EXISTING TO BE REMOVED
EWC ELECTRIC WATER COOLER
ERL EXISTING RELOCATED
FA FIRE ALARM
FH FUME HOOD
F.O. FIBER OPTIC CONNECTION
FV FILM VIEWER
FT FEET
G GROUND
KCMIL
ONE THOUSAND CIRCULAR MILS
KVA
KILOVOLT - AMPERES
KVAR
KILOVOLT - AMPERES REACTIVE
KW
KILOWATTS
LZR
LASER
MCB
MAIN CIRCUIT BREAKER
MCC
MOTOR CONTROL CENTER
MISC
MISCELLANEOUS
MLO
MAIN LUGS ONLY
NC
NORMALLY CLOSED
NCPS
NURSE CALL POWER SUPPLY
NEC
NATIONAL ELECTRICAL CODE
NL
NIGHT LIGHT
NO
NORMALLY OPEN
NITS
NOT TO SCALE
0
PHASE
P
POLE
PACS
PACS SYSTEM
PFA
PATIENT FIRE ALARM ANNUNCIATOR PANEL
P.T.
POTENTIAL TRANSFORMER
PTD
PNEUMATIC TUBE SYSTEM DIVERTER CONN.
PTS
PNEUMATIC TUBE SYSTEM CONNECTION
PVC
POLYVINYL CHLORIDE
R
RECESSED
REF
REFRIGERATOR
S
SECURITY SYSTEM
SCR
SHORT CIRCUIT INTERRUPTING RATING
SL
SURGICAL LIGHT
Sc
GAS SERVICE COLUMN
SS
SCRUB SINK
STE
STERILIZER
SP
SPARE
SW
SWITCH
TBL
TABLE
T/D
TEL /DATA CONNECTION
TEL
TELEPHONE
UG
UNDERGROUND
V
VOLT
VSE
VIDEO SUPPORT EQUIPMENT
Y
WYE
W
WATT
WP
WEATHERPROOF
XFMR
TRANSFORMER
XFP
X -RAY FILM PROCESSOR
XRY X -RAY
ELECTRICAL DRAWING INDEX _I
SHEET
DESCRIPTION
ISSUED
E -1
ELECTRICAL LEGEND & NOTES
Yes
E -2
PARTIAL 6TH FLOOR PLAN - DEMOLITION - ELECTRICAL
Yes
E -3
PARTIAL 6TH FLOOR PLAN - NEW WORK - POWER & SYSTEMS
Yes
E -4
PARTIAL 6TH FLOOR PLAN - EXISTING - LIGHTING & FIRE
Yes
E -5
ELECTRICAL PANEL SCHEDULES
Yes
E -6
ELECTRICAL SPECIFICATIONS
Yes
ALL DIMENSIONS
ARE
APPROXIMATE.
CON-rRACOR TO
VERIFY
DIMENSIONS IN
FIELD.
"TYPICAL" MEANS
THAT ALL SIMILAR
ITEMS ARE TO BE
HANDLES SIMILAR
TOTHE ONE
MARKED
"TYPICAL"
i'
10
I
I
�J l
Q
W
W
r0—
V I
0
LLJ ~ M
w
W �
ASSOdAYES
5624E SARIIINC RoAd
L �
ug
Cr-
9541,987 ,0206
O
—I
LL
,,,d�D/AyrAr�
BERT
�0
O O
OQ
Q0 l / J
C9 :5
MUM ®okgm(mli a
ASSOdAYES
5624E SARIIINC RoAd
v EE 3 $021
9541,987 ,0206
PRc iem NumbeR
®ATE
,,,d�D/AyrAr�
BERT
11041 -1
04- /30 /1L
r VNW
OINEERI %�
��e/�f'j
E,4,
°
project �h'','
y,�CORPQAATED
r��
RESPONSIVE ENOINEERINO -� ' --
MECHANICAL ELECTFOCAL Pum FM`il7F arm y °;
EAST
VEN L. WARSECK, AIA
L C'�NSE # AR 13228
1948 SUNRISE 0LVD,8UITE#I 4
FO FIT LAUDERDALE,FLORIDA08804 o '�
P. 06 ra 14,000E F.944.707.Y0>t4 Q m '�
■rM. ro�oteaom 4 /
� '. �
BU�.DING DIAGNOSTICS
A OCIATES, PA
LI NSE # AAF000114
A