12-1139-023N N L Q d a 0 �U O a N U f, N rn 0 0 v 07 N 0 N LE ELECTRICAL SYMBOLS LEGEND NOT ALL SYMBOLS SHOWN ARE FOR THIS PROJECT A FIXTURE TYPE 2X4 FLUORESCENT RECESSED FIXTURE LP24 a-+*— SWITCH POLE TYPE — PANEL /CIRCUIT NUMBER 2X4 FLUORESCENT RECESSED FIXTURE DIAGONAL HALF SHADE INDICATES CRITCAL BRANCH Q WALL MOUNTED FIXTURE ® UNDER CABINET LIGHT FIXTURE L 2X2 FLUORESCENT RECESSED FIXTURE -2X4 FLUORESCENT RECESSED FIXTURE FULL SHADE INDICATES LIFESAFETY BRANCH Nfr PENDANT MOUNTED LIGHT FIXTURE CEILING OR WALL MOUNTED EXIT SIGNS WITH BATTERY BACKUP. ®OR� CHEVRONS & SHADED AREA DETERMINES THE DIRECTION S LIGHT SWITCH DM = DIMMER 3 = 3 -WAY E = EMERGENCY RED SWITCH (CRITICAL LIGHTING) ELECTRICAL SYMBOLS LEGEND: POWER DUPLEX RECEPTACLE qp ABOVE COUNTER RECEPTACLE q) SIMPLEX RECEPTACLE All QUADRAPLEX RECEPTACLE �-� DUCT HEATER ELECTRICAL SYMBOLS LEGEND: SYSTEMS V VOICE /DATA OUTLET. VOICE JACKS AT TOP, (1) DATA JACKS, TYPICAL AT BOTTOM, BLANK CENTER SPACE, MOUNT AT 18" AFF TO CENTER, UON. PROVIDE & INSTALL 3/4" EMPTY CONDUIT W /PULLSTRING EMPTY CONDUITS, BACKBOXES & OUTLETS SHALL BE FURNISHED AND INSTALLED IN ACCORDANCE WITH INFORMATION TECHNOLOGY DEPT. REQUIREMENTS. CONDUITS SHALL TERMINATE ABOVE NEAREST ACCESSIBLE CEILING, Y THERMOSTAT; REFER TO MECHANICAL DWGS. FLOOR OR WALL MOUNTED TV OUTLET ❑S CEILING SPEAKER P = PAGING AV = AUDIO /VISUAL FA = FIRE ALARM CAMERA SYSTEM PAN /TILT /ZOOM SECURITY CAMERA D = DOME CEILING MOUNTED �p MOTOR KVA MOTOR WITH DISCONNECT E].I MOTOR WITH DISCONNECT O WALL MOUNTED THERMOSTAT LZR REFER TO MECHANICAL DRAWINGS MCB WALL MOUNTED JUNCTION BOX QOR Y CEILING (W /HARD CONNECTION) OR CD = CANDELA WALL MTD. JUNCTION BOX DUPLEX RECEPTACLE qp ABOVE COUNTER RECEPTACLE q) SIMPLEX RECEPTACLE All QUADRAPLEX RECEPTACLE �-� DUCT HEATER ELECTRICAL SYMBOLS LEGEND: SYSTEMS V VOICE /DATA OUTLET. VOICE JACKS AT TOP, (1) DATA JACKS, TYPICAL AT BOTTOM, BLANK CENTER SPACE, MOUNT AT 18" AFF TO CENTER, UON. PROVIDE & INSTALL 3/4" EMPTY CONDUIT W /PULLSTRING EMPTY CONDUITS, BACKBOXES & OUTLETS SHALL BE FURNISHED AND INSTALLED IN ACCORDANCE WITH INFORMATION TECHNOLOGY DEPT. REQUIREMENTS. CONDUITS SHALL TERMINATE ABOVE NEAREST ACCESSIBLE CEILING, Y THERMOSTAT; REFER TO MECHANICAL DWGS. FLOOR OR WALL MOUNTED TV OUTLET ❑S CEILING SPEAKER P = PAGING AV = AUDIO /VISUAL FA = FIRE ALARM CAMERA SYSTEM PAN /TILT /ZOOM SECURITY CAMERA D = DOME CEILING MOUNTED �p PUSH BUTTON KVA DR = DOOR RELEASE KVAR A = PANIC ALARM ELECTRICAL SYMBOLS LEGEND: FIRE � DCEILING MOUNTED SMOKE DETECTOR LZR WALL MOUNTED STROBE ONLY MCB L = LIGHT MCC WALL MOUNTED HORN /STROBE MISC CD = CANDELA FS CEILING MOUNTED HORN /STROBE NC CD = CANDELA NCPS WALL MOUNTED PULL STATION F(V_ FIRE ALARM CONTROL PANEL FAA FIRE ALARM ANNUNCIATOR PANEL FS FLOW SWITCH FT S-1 TAMPER SWITCH FM-D-1 MOTION DETECTOR FOR AUTOMATIC DOOR ML_ _@ `� JUNCTION BOX FOR MAGNETC LOCKS ®J RELAY CR CARD READER 4 DOOR MANUAL PUSH BUTTON NOTES: PNEUMATIC TUBE SYSTEM DIVERTER CONN. 1. EMPTY CONDUITS AND BACKBOXES SHALL BE FURNISHED AND INSTALLED IN ACCORDANCE WITH NURSE CALL VENDOR REQUIREMENTS. CONDUITS SHALL TERMINATE ABOVE NEAREST ACCESSIBLE CEILING. REF REFRIGERATOR SYMBOL LIST SECURITY SYSTEM SCR SHORT CIRCUIT INTERRUPTING RATING MOUNTING HEIGHTS SHALL BE AS INDICATED SURGICAL LIGHT Sc GAS SERVICE COLUMN UNLESS SHOWN OTHERWISE ON ELECTRICAL SCRUB SINK STE STERILIZER DRAWINGS OR ARCHITECTURAL ELEVATIONS SPARE GENERAL NOTES 1, CONTRACTOR SHALL REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT LOCATION OF LIGHT FIXTURES AND ALL CEILING MOUNTED DEVICES. 2. CONTRACTOR SHALL PROVIDE AND INSTALL AN IDENTIFICATION NAMEPLATE FOR EACH ELECTRICAL EQUIPMENT /APPURTENANCES DEPICTING THE DESIGNATION INDICATED ON THE DRAWINGS. 3. ALL EMPTY CONDUITS SYSTEMS SHALL CONTAIN A PULL WRE FOR FUTURE PULLING OF CONDUCTORS. 4. CONTRACTOR SHALL COORDINATE ALL REQUIRED ENERGY MANAGEMENT SYSTEM POINTS AND CONTACTS CONNECTIONS TO ENSURE THE COMPLETE AND PROPER OPERATION OF ALL SYSTEMS. 5. CONTRACTOR SHALL PROVIDE AND INSTALL A 1" CONDUIT W /PULL WRE FROM EACH WALL MOUNTED TELEPHONE AND /OR DATA OUTLET STUB UP 6- ABOVE FINISHED CEILING, 6. THE CONTRACTOR SHALL COORDINATE WITH OTHER TRADES ALL NECESSARY WRING AND CONNECTIONS REQUIRDE PRIOR TO PULLING CONDUCTOIRS INTO NEW CONDUITS. 7. CONTRACTOR SHALL PROVIDE ALL EQUIPMENT AND MATERIAL NECESSARY FOR A COMPLETE AND OPERATIONAL INSTALLATION. 8. CONTRACTOR SHALL CONNECT ALL NEW FIRE ALARM DEVICES, AS INDICATED ON DRAWINGS+ TO EXISTING SYSTEM, CONTRACTOR SHALL PROVIDE NEW EXPANDABLE MODULES, CARDS, ETC, 'AS REQUIRED, IN ORDER TO ACCOMODATE NEW DEVICES. 9. ALL RECEPTACLES AND SWITCH PLATES SHALL HAVE ENGRAVED COVER PLATES TO INDICATE THE PANEL BOARD AND CIRCUIT NUMBERS POWERING THE DEVICE. 10. AIC RATING OF CIRCUIT BREAKERS SHALL MATCH PANEL IN WHICH INSTALLED. 11. CONTRACTOR SHALL UPDATE ALL ELECTRICAL PANEL SCHEDULES AFFECTED BY THIS PROJECT. HAND WRITTEN SCHEDULES ARE NOT ACCEPTED. SCHEDULES SHALL BE TYPED OR COMPUTER GENERATED. 12, IT IS THE RESPONSIBILITY OF MECHANICAL, ELECTRICAL, PLUMBING AND FIRE PROTECTION CONTRACTORS TO VISIT THE SITE AND EXAMINE IN DETAIL THE SCOPE OF WORK OF THIS PROJECT AND SHALL NOTIFY THE ARCHITECT AND /OR ENGINEER IF A CONDITION EXISTS WHICH PREVENTS HIM /HER FROM ACCOMPLISHING THE WORK INDICATED AND INTENDED BY THESE DRAWNGS, SO NO ADDITIONAL COST IS INCURRED BY THE OWNER. AFTER CONTRACT IS AWARDED IT WILL BE ASSUMED THAT THE SITE WAS VISITED AND EXAMINED AND ALL PARTIES ARE IN AGREEME T WITH THE SCOPE OF THE WORK. 13. IT IS THE RESPONSIBILITY OF THE ELECTRICAL, MECHANICAL, PLUMBING, AND FIRE PROTECTION CONTRACTORS TO COORDINATE THE INSTALLATION OF ALL EQUIPMENT, DEVICES, ETC WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO: SPRINKLER HEADS, HVAC DIFFUSERS, LIGHT FIXTURES, SMOKE DETECTORS, ETC. 14, THE ARCHITECTURAL, MECHANICAL, PLUMBING AND FIRE PROTECTION DRAWINGS ARE INHERENTLY PART OF THESE COMPLETE SET OF CONTRACT DOCUMENTS. 15. LIGHT SWITCHES SHALL BE MOUNTED 48 INCHES ABOVE FINISHED FLOOR TO CENTER LINE OF DEVICE, UNLESS OTHERWISE NOTED, 16. RECEPTACLES SHALL BE LOCATED 18 INCHES ABOVE FINISHED FLOOR TO CENTER LINE OF DEVICE, UNLESS OTHERWISE NOTED. ABOVE COUNTER RECEPTACLES SHALL BE MOUNTED 6 °ABOVE BACK SPLASH TO CENTERLINE OF DEVICE. 17. THE EQUIPMENT GROUNDING TERMINAL BARS OF THE NORMAL AND ESSENTIAL ELECTRICAL SYSTEM PANELBOARDS SERVING THE SAME PATIENT VICINITY SHALL BE BONDED TOGETHER, WITH AN INSULATED, CONTINUOUS, COPPER CONDUCTOR NOT SMALLER THAN NUMBER 10, 18. EQUIPMENT SHALL BE OF MATERIALS SUITABLE FOR AND RATED FOR THE ENVIRONMENT IN WHICH THEY ARE TO BE INSTALLED, 19. WORKING CLEARANCES FOR ELECTRICAL EQUIPMENT SHALL BE IN COMPLIANCE WITH NEC 110. 20. PATIENT CARE AREAS SHALL BE INSTALLED & PROVIDED WITH GROUNDING IN ACCORDANCE WITH NEC 517.2 & 517.13(A) & 517.13(B). 21. WHEN ELECTRICAL BOXES ARE LOCATED IN VERTICAL FIRE RESISTIVE ASSEMBLIES, (CLASSIFIED AS FIRE /SMOKE AND SMOKE PARTITIONS), THEY SHALL BE INSTALLED WITHOUT AFFECTING THE FIRE CLASSIFICATION. ALL OF THE FOLLOWING CONDITIONS SHALL BE MET: A. ALL ELECTRICAL BOXES SHALL BE METALLIC. B, BOX OPENING SHALL OCCUR ONLY ON ONE SIDE OF FRAMING SPACE. C. BOX OPENING SHALL NOT EXCEED 16 SQUARE INCHES. D. ALL CLEARANCES BETWEEN OUTLET BOX AND GYPSUM BOARD SHALL BE COMPLETELY FILLED WITH JOINT COMPOUND (OR OTHER APPROVED MATERIAL). E. PROVIDE A WALL AROUND OUTLETS LARGER THAN 16 SQUARE INCHES. THE INTEGRITY OF THE WALL RATING SHALL BE MAINTAINED. F. THE TOTAL AGGREGATE SURFACE AREA OF THE BOXES SHALL NOT EXCEED 100 SQUARE INCHES PER 100 SQUARE FEET. G. OUTLET BOXES LOCATED ON OPPOSITE SIDES OF FIRE RESISTIVE ASSEMBLIES SHALL BE SEPARATED BY A MINIMUM HORIZONTAL DISTANCE OF 24 INCHES. H. OUTLET BOXES SHALL BE SECURELY FASTENED TO WALL FRAMING MEMBERS I. THE OPENING IN THE GYPSUM BOARD FACING SHALL BE CUT NOT TO EXCEED 1/8 INCH BETWEEN THE EDGES OF THE OUTLET BOX AND THE EDGES OF THE OPENING. 22. NON- METALLIC RACEWAYS SHALL NOT BE USED TO SERVE ANY PATIENT CARE SPACE. ALL WRING SHALL BE MECHANICALLY PROTECTED BY INSTALLATION IN METALLIC RACEWAYS, 23. ALL DEVICES SHALL BE MOUNTED VERTICAL, UNLESS OTHERWISE NOTED. 24, ALL RECEPTACLES SHALL BE MOUNTED SUCH THAT THE GROUND PIN IS MOUNTED UP. 25, THE NUMBER OF ARROWHEADS ON THE HOMERUNS DENOTES THE NUMBER OF CIRCUITS. ABBREVIATIONS A AMPERES AF AMPERE FRAME (CIRCUIT BREAKER RATING) AFF ABOVE FINISHED FLOOR AFG ABOVE FINISHED GRADE AIC AMPERE INTERRUPTING CAPACITY AL ALUMINUM ARCH ARCHITECT AT AMPERE TRIP (CIRCUIT BREAKER RATING) ATS AUTOMATIC TRANSFER SWITCH. AUD AUDIOMETER BOX CONNECTION AWG AMERICAN WIRE GAUGE BIN X -RAY FILM BIN BLDG BUILDING C CONDUIT C. B. CIRCUIT BREAKER C. T. CURRENT TRANSFORMER CAB CABINET, WARMING CAM CAMERA CAT CATALOG CIR CIRCUIT CLM COLUMN CU COPPER LL DELTA DWG DRAWING EM WIRED ON EMERGENCY CIRCUIT EC EMPTY CONDUIT EX EXISTING TO BE REMOVED EWC ELECTRIC WATER COOLER ERL EXISTING RELOCATED FA FIRE ALARM FH FUME HOOD F.O. FIBER OPTIC CONNECTION FV FILM VIEWER FT FEET G GROUND KCMIL ONE THOUSAND CIRCULAR MILS KVA KILOVOLT - AMPERES KVAR KILOVOLT - AMPERES REACTIVE KW KILOWATTS LZR LASER MCB MAIN CIRCUIT BREAKER MCC MOTOR CONTROL CENTER MISC MISCELLANEOUS MLO MAIN LUGS ONLY NC NORMALLY CLOSED NCPS NURSE CALL POWER SUPPLY NEC NATIONAL ELECTRICAL CODE NL NIGHT LIGHT NO NORMALLY OPEN NITS NOT TO SCALE 0 PHASE P POLE PACS PACS SYSTEM PFA PATIENT FIRE ALARM ANNUNCIATOR PANEL P.T. POTENTIAL TRANSFORMER PTD PNEUMATIC TUBE SYSTEM DIVERTER CONN. PTS PNEUMATIC TUBE SYSTEM CONNECTION PVC POLYVINYL CHLORIDE R RECESSED REF REFRIGERATOR S SECURITY SYSTEM SCR SHORT CIRCUIT INTERRUPTING RATING SL SURGICAL LIGHT Sc GAS SERVICE COLUMN SS SCRUB SINK STE STERILIZER SP SPARE SW SWITCH TBL TABLE T/D TEL /DATA CONNECTION TEL TELEPHONE UG UNDERGROUND V VOLT VSE VIDEO SUPPORT EQUIPMENT Y WYE W WATT WP WEATHERPROOF XFMR TRANSFORMER XFP X -RAY FILM PROCESSOR XRY X -RAY ELECTRICAL DRAWING INDEX _I SHEET DESCRIPTION ISSUED E -1 ELECTRICAL LEGEND & NOTES Yes E -2 PARTIAL 6TH FLOOR PLAN - DEMOLITION - ELECTRICAL Yes E -3 PARTIAL 6TH FLOOR PLAN - NEW WORK - POWER & SYSTEMS Yes E -4 PARTIAL 6TH FLOOR PLAN - EXISTING - LIGHTING & FIRE Yes E -5 ELECTRICAL PANEL SCHEDULES Yes E -6 ELECTRICAL SPECIFICATIONS Yes ALL DIMENSIONS ARE APPROXIMATE. CON-rRACOR TO VERIFY DIMENSIONS IN FIELD. "TYPICAL" MEANS THAT ALL SIMILAR ITEMS ARE TO BE HANDLES SIMILAR TOTHE ONE MARKED "TYPICAL" i' 10 I I �J l Q W W r0— V I 0 LLJ ~ M w W � ASSOdAYES 5624E SARIIINC RoAd L � ug Cr- 9541,987 ,0206 O —I LL ,,,d�D/AyrAr� BERT �0 O O OQ Q0 l / J C9 :5 MUM ®okgm(mli a ASSOdAYES 5624E SARIIINC RoAd v EE 3 $021 9541,987 ,0206 PRc iem NumbeR ®ATE ,,,d�D/AyrAr� BERT 11041 -1 04- /30 /1L r VNW OINEERI %� ��e/�f'j E,4, ° project �h'',' y,�CORPQAATED r�� RESPONSIVE ENOINEERINO -� ' -- MECHANICAL ELECTFOCAL Pum FM`il7F arm y °; EAST VEN L. WARSECK, AIA L C'�NSE # AR 13228 1948 SUNRISE 0LVD,8UITE#I 4 FO FIT LAUDERDALE,FLORIDA08804 o '� P. 06 ra 14,000E F.944.707.Y0>t4 Q m '� ■rM. ro�oteaom 4 / � '. � BU�.DING DIAGNOSTICS A OCIATES, PA LI NSE # AAF000114 A