12-1139-022APPUCABLE CODES A. STATE, COUNTY, AND CITY HEALTH AND BUILDING CODES, B. NFPA 51B, 2009 EDITION. C. NFPA 70, 2008 EDITION. D. NFPA 72, 2007 EDITION. E. NFPA 90A, 2009 EDITION, F. NFPA 101, LIFE SAFETY CODE, 2009 EDITION G. FLORIDA BUILDING CODE— BUILDING, 2010 EDITION H. FLORIDA BUILDING CODE— MECHANICAL, 2010 I. FLORIDA BUILDING CODE— PLUMBING, 2010 J. OTHER NFPA CODES AS REFERENCED BY STANDARD CODES. K. FGI GUIDELINES FOR DESIGN AND CONSTRUCTION OF HEALTHCARE FACILITIES 2010 EDITION L. 2009 FLORIDA FIRE PREVENTION CODE M. FLORIDA ADMINISTRATIVE CODE CHAPTER 59A -3. N. FLORIDA ADMINISTRATIVE CODE CHAPTER 69A- 3.012. 0. FLORIDA ADMINISTRATIVE CODE CHAPTER 69A -60 SECTION 633.022. TEST & BALANCE NOTES 1. PRECONSTRUCTION: PRIOR TO COMMENCEMENT OF ANY HVAC WORK AN INDEPENDENT AABC OR NEBB CERTIFIED T &B CONTRACTOR SHALL MEASURE AND DOCUMENT, IN A TYPED REPORT THE AIRFLOW QUANTITIES PROVIDED OR EXHAUSTED BY ALL EXISTING EQUIPMENT AND DUCTS TO REMAIN THAT SERVE OR ARE SERVED FROM THE RENOVATED AREA, SUBMIT DATA TO ENGINEER FOR REVIEW. THE FOLLOWING INFORMATION IS REQUIRED: — AIR FLOW �T` ALL AIR DEVICES IN RENOVATED AREAS). — AIR FLOW RAVERSE AT MAINS AND BRANCH DUC S SERVING THE RENOVATED AREA(S). AIR FLOW UNITS TRAVERSE) AT MAINS AND BRANCH DUCTS SERVING THE RENOVATED AREA(S). — SUCTION AND DISCHARGE STATIC AT UNITS SERVING THE RENOVATED AREA(S). — MEASURED FAN RPM, MOTOR AMPERAGE FOR ALL UNITS SERVING THE RENOVATED AREA(S). — PROVIDE EXISTING UNIT AND MOTOR NAME PLATE DATE. — CHILLED WATER AND HOT WATER TEMP AND FLOW TO AND FROM ALL AHU'S & FCU'S IN RENOVATED AREA(S), 2. FINAL CONSTRUCTION: UPON COMPLETION OF THE HVAC RENOVATION WORK, THE SAME CONTRACTOR SHALL REBALANCE THE NEW AND EXISTING EQUIPMENT AND DUCTS TO PROVIDE INDICATED AIR QUANTITIES TO THE RENOVATED SPACE. ANY ADDITION OF DAMPERS, ADJUSTMENTS, FAN SPEED, CHANGE OUT OF PULLEYS, ETC.) REQUIRED FOR THIS SHALL BE INCLUDED IN THIS CONTRACTORS PROPOSAL. 3, FINAL REPORT: SUBMIT FINAL TEST AND BALANCE REPORT TO ENGINEER FOR REVIEW AND ACCEPTANCE. ONE WEEK PRIOR TO FINAL AHCA INSPECTION FOR EACH PHASE. INFECTION CONTROL MEASURES 1. CONTRACTOR SHALL OBTAIN FROM THE OWNER A COPY OF THE INFECTION CONTROL RISK ASSESSMENT (ICRA) PREPARED FOR THIS PROJECT. CONTRACTOR SHALL REVIEW THE REQUIREMENTS IN THE REPORT AND PERFORM ALL WORK IN ACCORDANCE WITH THOSE REQUIREMENTS, CONTRACTOR SHALL STRICTLY ADHERE TO THE LIMITS OF THE CONSTRUCTION AREA, AND WHERE PHASING APPLIES SHALL ADHERE TO THE PHASING PLAN. ANY WORK OUTSIDE THE CONSTRUCTION AREA SHALL BE COORDINATED WITH THE OWNER AND PERFORMED IN ACCORDANCE WITH THE ICRA REPORT, UNDER THE SUPERVISION OF THE OWNER'S REPRESENTATIVE OR OTHER DESIGNATED ICRA COMMITTEE OFFICER. 2. TO THE EXTENT THAT IT IS REQUIRED BY THE ICRA, THE CONTRACTOR SHALL ENDEAVOR TO MAINTAIN EXISTING LEVELS OF INDOOR AIR QUALITY IN AREAS SURROUNDING AND ADJACENT TO THE CONSTRUCTION WORK ZONE, AND ELSEWHERE IN THE FACILITY. IT SHOULD BE ANTICIPATED THAT THE ICRA REPORT WILL REQUIRE MEASURES TO THIS EFFECT INCLUDING ERECTION OF CONSTRUCTION ZONE BARRIERS AND PROVISION OF NEGATIVE AIR PRESSURE IN THE CONSTRUCTION ZONE RELATIVE TO OTHER AREAS OF THE FACILITY. 3. IN ADDITION TO THE MEETING THE REQUIREMENTS OF THE ICRA REPORT, THE CONTRACTOR AT A MINIMUM SHALL PROVIDE EQUIPMENTAND COMPONENTS NECESSARY TO CREATE A NEGATIVE PRESSURE IN THE CONSTRUCTION WORK ZONE RELATIVE TO ADJACENT AREA. EXISTING HVAC SYSTEMS AND COMPONENTS SHALL NOT BE USED FOR THIS FUNCTION, UNLESS SPECIFICALLY APPROVED BY THE OWNER'S INFECTION CONTROL OFFICER. THE CONCEPT AND ALL ASPECTS OF THIS WORK SHALL BE DONE IN ACCORDANCE WITH THE ICRA REQUIREMENTS AND AT A MINIMUM AS FOLLOWS: VERIFY ALL EXISTING DUCTWORK WHICH PASSES THROUGH THE CONSTRUCTION ZONE, AND IS TO REMAIN, IS SEALED (CAPPED) AND PROTECTED DURING THE CONSTRUCTION DURATION. AIR REMOVED FROM THE CONSTUCTION ZONE SHALL BE FILTERED AND /OR DISCHARGED AS DIRECTED BY THE ICRA REPORT. PRESENT THE NEGATIVE AIR PRESSURE PLAN TO THE OWNER FOR APPROVAL BY THE INFECTION CONTROL COMMITTEE. PROVIDE MEANS TO MONITOR AND VERIFY NEGATIVE PRESSURE IS BEING MAINTAINED IN ACCORDANCE WITH THE ICRA REPORT, AND PROVIDE DOCUMENTATION TO THE OWNER AS REQUIRED. 4. COORDINATE IN ADVANCE ANY REQUIRED EQUIPMENT SHUTDOWN WITH THE OWNER, AND VERIFY BEFORE SHUTDOWN THAT EXISTING OR DESIRED AIR PRESSURE RELATIONSHIPS WILL NOT BE ADVERSALY AFFECTED. 5. PROVIDE LAMIFLOW #LN -102 & LP -102 FOR CONSTRUCTION SITE NEGATIVE PRESSURE MONITORING. 6. CONTRACTOR SHALL PROVIDE STICKEY MATTS AT THE CONSTRUCTION SITE ENTRANCES IN ACCORDANCE WITH THE IRCA REPORT. 7. CONTRACTOR SHALL PROVIDE SPOT COOLERS AS REQUIRED DURING CONSTRUCTION TO MAINTAIN THE CONSTRUCTION ENVIROMENT TO 75 DEGREES AS REQUIRED. L N N L Q a 0 0 U 0 rn v c m N 0 N LIP] jIM001�ZON�ITA�; project €r x Ni„ONIIYl1NOINII RING y 10110H WAL NLlCINML lLAl11NN10lNIL II •1 t1O1 TNLAiYT iNONANLNiI fIOYNIDA 4"11 �. IN.71 •IIt F.161.7$7.9 84 n iota w'�.u� ate,. ALL DIMENSIONS AR E APPROXIMATE, CONTRACTOR To VERIFY DIMENSIONS IN FIELD. "TYPICAL" MEANS THAT ALL. SIMILAR ITEMS ARE To BE HANDLES SIMILAR TOTHE ONE MARKED "TYPICAL" W 0 I W 0— Ln 0 Z Buk&mq D'0kgf mAccs Asso0kifFs 5824 SiditU q I oAd v FL 3 Y021 954. 987,0206 PmJ®CP NWIIb11 �9ATE 110q 1 0�/�0/ 12 Sckk Dim" By AS SHOWN -TQ L BEN L. WARSECK, AIA =NSE # AR 13228 LDING DIAGNOSTICS 30CIATES, PA =NSE # AAF000114 wimq NUINI 6 M -3 ~ 00 w w 0-) CK ¢ v I O — O —� ( LL ao LL O O Q Buk&mq D'0kgf mAccs Asso0kifFs 5824 SiditU q I oAd v FL 3 Y021 954. 987,0206 PmJ®CP NWIIb11 �9ATE 110q 1 0�/�0/ 12 Sckk Dim" By AS SHOWN -TQ L BEN L. WARSECK, AIA =NSE # AR 13228 LDING DIAGNOSTICS 30CIATES, PA =NSE # AAF000114 wimq NUINI 6 M -3