11-853R-018• 1111" I edward-le�Vis - architects 0 9024 Sw 152 STREET" PALMETTO BAY, FL 33157 PH: (305) 234-6876' EDWARD LEWIS ARCHrTEcTs, AAC001678 C. EDWARD LEWIS AIR 0009567 System No. W—L-5029 F Ratings — I and 2 Hr (See Item 1) T Ratings — 1/2, 3/4, 1 and 1-3/4 Hr (See Item 3) L Rating At Ambient — 4 CFM/Sq Ft L Rating At 400 F —Less Than 1 CFM/Sq Ft FINISHED WALL FLUSH VALVE (MAX. 44- AFF FOR HANDLE OPERATION) A WATER SUPPLY SOLID RING PIPE SUPPORT (2 REQUIRED) 4 0 FINISHED WALL SURFACE 3 GRAB BAR (BY OTHERS) �D TEST TEE ACCESS COVER AND FRAME 2 M THREADED CLEANOUT PLUG V) A 9 4 n V) SECTION A-A it WATERR CLOSET 4 4 1. Wall Assembly — The 1 or 2 hr fire—rated gypsum wallboard/stud wall assembly shall be constructed of the materials and in the manner specified in the individual 0300 or U400 Series Wall and Partition Designs in the UL Fire Resistance Directory and shall include the following construction features: THE HANDLE OF THE FLUSH VALVE A. Studs — Wall framing may consist of either wood studs or steel SHALL FACE THE WIDE SIDE OF channel studs. Wood studs to consist of nom 2 by 4 in. lumber spaced THE STALL (NO EXCEPTIONS). 16 in. OC. Steel studs to be min 2-1/2 in. wide and spaced max 24 in. OC. B. Wallboard, Gypsum* — 5/8 in. thick, 4 ft Wide, with square or tapered edges. The gypsum wallboard type, thickness, number of layers, fastener type and sheet orientation shall be as specified in the individual Wall and Partition Design. Max diem of opening is 18-5/8 in. The hourly F Rating of the firestop system is equal to the hourly fire rating of the wall assembly in which it is installed. WATER CLOSET 3 WALL CLEANOl1T Z Through Penetrants — One metallic pipe, conduit or tubing to be centered No $cale No Scale within the firestop system. Poe, conduit or tubing to be rigidly supported on both sides of wall assembly. The following types and sizes of metallic pipes, conduits or tubing may be used: A. Steel Pipe — Nom 12 in diem (or smaller) Schedule 10 (or heavier) steel pipe. B. Conduit — Norn 4 in. diem (or smaller) electrical metallic tubing or steel conduit. C. Copper Tubing — Norn 6 in. diem (or smaller) Type L (or heavier) copper tubing. D. Copper Pipe — Nom 6 in. diem (or smaller) Regular (or heavier) copper PIPS 3. Pipe Covering* — Norn 1, 1-1/2 or 2 in. thick hollow cylindrical heavy density (min 3.5 pcf) glass fiber units jacketed on the outside with an all service jacket Longitudinal Pints sealed with metal fasteners or factory— applied self—sealing lop tape. Transverse Pints secured With metal fasteners or With butt tape supplied With the product. See Pipe and Equipment Covering — Materials (BRGU) category in PIPE HANGER the Building Material Directory for the names of manufacturers. Any (SEE SPECS.) pipe covering material meeting the above specifications and bearing the UL Classification Marking with a Flame Spread Index of 25 or less and a Smoke Developed Index of 50 or less may be used. The hour T Rating of the firestop system is dependent on the hourly fire rating of the wall assembly in which it is installed, the size and type of through penetrant and the pipe covering thickness, as shown in the table GALVANIZED SHEETMETAL below. PIPE SADDLE W/FLARED ENDS Wall Through Pipe Assembly Penetrant Covering Annular Space T DS Rating Max Diam Thkns Min Max Rating Hr Type+ In. In. In. In. Hr 1 A or B 4 1 0 1-1/2 1/2 1 C or D 2 1 or 1-1/2 0 1-112 1/2 '�n DIDC' 1 A or B 4 1-1/2 0 .0. INSULATED PIPE 1 A 12 2 0 1— Vl�).28 3/14 V-0, 1 C or D 6 2 0 1-7/8 1 2 A or B 4 1 0 1-1/2 1 2 C or D 4 1 or 1-1/2 0 1-1/2 1 2 C or D 6 2 0 1-7/8 1 2 A or B 4 1-1/2 0 1-1/2 1-3/4 2 A 12 2 0 1-7/8 1-1/2 2 C or D 6 2 0 1-7/8 1 +Indicates penetrant type as itemized in Item 2. 4. Fill Void or Cavity Material* — Sealant — Min 5/8 in. thickness of fill material applied within the annulus, flush with both surfaces of wall for 1 or 2 hr walls, respectively. At the point contact location between pipe covering and gypsum wallboard, a min 1/2 in, diem bead of fill material shall be applied at the pipe covering /gypsum wallboard interface on both surfaces of wall. HIL11 CONSTRUCTION CHEMICALS, DIY OF HILTI, Inc — FS—ONE Sealant *Bearing the UL Classification Marking WALL DRYWALL -PIPE/INSULATED 1/2 HR INSULATED PIPE HANGER System No. W-L-5029 No Scale INCb IN255 S. Orange Avenue Site 1600 Orlando, Fbft 32801 Phone: 407-841-9050 ENGINEERING Fax: 407-540-0234 FOR ARCHITECTURE www.tic-engineemcom 0 copyright 2010 TLC Engineering for Architecture, Inc. EB 10000015 TLC NO:11111355 Stir■twall En*w Is ri seal Do%AjRiley, P.E. Ice 1135067 35087 Rovbdm ProJect Nmiiber q. 10-036. B Date MARCH, 2011 81met PLUMBINM DETAILS Drmm bye NRK Cblm*od WE Mpg sheet Nwdw System No. W—L-5029 F Ratings — I and 2 Hr (See Item 1) T Ratings — 1/2, 3/4, 1 and 1-3/4 Hr (See Item 3) L Rating At Ambient — 4 CFM/Sq Ft L Rating At 400 F —Less Than 1 CFM/Sq Ft FINISHED WALL FLUSH VALVE (MAX. 44- AFF FOR HANDLE OPERATION) A WATER SUPPLY SOLID RING PIPE SUPPORT (2 REQUIRED) 4 0 FINISHED WALL SURFACE 3 GRAB BAR (BY OTHERS) �D TEST TEE ACCESS COVER AND FRAME 2 M THREADED CLEANOUT PLUG V) A 9 4 n V) SECTION A-A it WATERR CLOSET 4 4 1. Wall Assembly — The 1 or 2 hr fire—rated gypsum wallboard/stud wall assembly shall be constructed of the materials and in the manner specified in the individual 0300 or U400 Series Wall and Partition Designs in the UL Fire Resistance Directory and shall include the following construction features: THE HANDLE OF THE FLUSH VALVE A. Studs — Wall framing may consist of either wood studs or steel SHALL FACE THE WIDE SIDE OF channel studs. Wood studs to consist of nom 2 by 4 in. lumber spaced THE STALL (NO EXCEPTIONS). 16 in. OC. Steel studs to be min 2-1/2 in. wide and spaced max 24 in. OC. B. Wallboard, Gypsum* — 5/8 in. thick, 4 ft Wide, with square or tapered edges. The gypsum wallboard type, thickness, number of layers, fastener type and sheet orientation shall be as specified in the individual Wall and Partition Design. Max diem of opening is 18-5/8 in. The hourly F Rating of the firestop system is equal to the hourly fire rating of the wall assembly in which it is installed. WATER CLOSET 3 WALL CLEANOl1T Z Through Penetrants — One metallic pipe, conduit or tubing to be centered No $cale No Scale within the firestop system. Poe, conduit or tubing to be rigidly supported on both sides of wall assembly. The following types and sizes of metallic pipes, conduits or tubing may be used: A. Steel Pipe — Nom 12 in diem (or smaller) Schedule 10 (or heavier) steel pipe. B. Conduit — Norn 4 in. diem (or smaller) electrical metallic tubing or steel conduit. C. Copper Tubing — Norn 6 in. diem (or smaller) Type L (or heavier) copper tubing. D. Copper Pipe — Nom 6 in. diem (or smaller) Regular (or heavier) copper PIPS 3. Pipe Covering* — Norn 1, 1-1/2 or 2 in. thick hollow cylindrical heavy density (min 3.5 pcf) glass fiber units jacketed on the outside with an all service jacket Longitudinal Pints sealed with metal fasteners or factory— applied self—sealing lop tape. Transverse Pints secured With metal fasteners or With butt tape supplied With the product. See Pipe and Equipment Covering — Materials (BRGU) category in PIPE HANGER the Building Material Directory for the names of manufacturers. Any (SEE SPECS.) pipe covering material meeting the above specifications and bearing the UL Classification Marking with a Flame Spread Index of 25 or less and a Smoke Developed Index of 50 or less may be used. The hour T Rating of the firestop system is dependent on the hourly fire rating of the wall assembly in which it is installed, the size and type of through penetrant and the pipe covering thickness, as shown in the table GALVANIZED SHEETMETAL below. PIPE SADDLE W/FLARED ENDS Wall Through Pipe Assembly Penetrant Covering Annular Space T DS Rating Max Diam Thkns Min Max Rating Hr Type+ In. In. In. In. Hr 1 A or B 4 1 0 1-1/2 1/2 1 C or D 2 1 or 1-1/2 0 1-112 1/2 '�n DIDC' 1 A or B 4 1-1/2 0 .0. INSULATED PIPE 1 A 12 2 0 1— Vl�).28 3/14 V-0, 1 C or D 6 2 0 1-7/8 1 2 A or B 4 1 0 1-1/2 1 2 C or D 4 1 or 1-1/2 0 1-1/2 1 2 C or D 6 2 0 1-7/8 1 2 A or B 4 1-1/2 0 1-1/2 1-3/4 2 A 12 2 0 1-7/8 1-1/2 2 C or D 6 2 0 1-7/8 1 +Indicates penetrant type as itemized in Item 2. 4. Fill Void or Cavity Material* — Sealant — Min 5/8 in. thickness of fill material applied within the annulus, flush with both surfaces of wall for 1 or 2 hr walls, respectively. At the point contact location between pipe covering and gypsum wallboard, a min 1/2 in, diem bead of fill material shall be applied at the pipe covering /gypsum wallboard interface on both surfaces of wall. HIL11 CONSTRUCTION CHEMICALS, DIY OF HILTI, Inc — FS—ONE Sealant *Bearing the UL Classification Marking WALL DRYWALL -PIPE/INSULATED 1/2 HR INSULATED PIPE HANGER System No. W-L-5029 No Scale INCb IN255 S. Orange Avenue Site 1600 Orlando, Fbft 32801 Phone: 407-841-9050 ENGINEERING Fax: 407-540-0234 FOR ARCHITECTURE www.tic-engineemcom 0 copyright 2010 TLC Engineering for Architecture, Inc. EB 10000015 TLC NO:11111355 Stir■twall En*w Is ri seal Do%AjRiley, P.E. Ice 1135067 35087 Rovbdm ProJect Nmiiber q. 10-036. B Date MARCH, 2011 81met PLUMBINM DETAILS Drmm bye NRK Cblm*od WE Mpg sheet Nwdw