HVAC SYMBOL LEGEND
HVAC ABBREVIATIONS
GENERAL NOTES
SYMBOL
DESCRIPTION
SYMBOL
DESCRIPTION
SYMBOL
DESCRIPTION
SYMBOL
DESCRIPTION
SYMBOL DESCRIPTION
1. CONNECTION TO EQUIPMENT SHALL. BE VERIFIED WITH MANUFACTURER'S CERTIFIED DRAWINGS.
LIL
r
- CElUNG DIFFUSER, ROUND NECK
—
FIRE DAMPER
•
•
,
•
- TETtMINAI UNIT, VARIABLE /CONSTANT AIR VOLUME
qFp
AFF
- ADJUSTABLE FREQUENCY DRIVE
-ABOVE FINISHED FLOOR
MCA
MOCP
- MINIMUM CIRCUIT AMPS
- MAXIMUM OVER CURRENT PROTECTION
TRANSITIONS TO ALL EQUIPMENT SHALL BE VERIFIED AND PROVIDED FOR EQUIPMENT
FURNISHED.
(CEILING DIFFUSERS ARE 4-WAY THROW UNa)
(WITH ACCESS PANEL)
- TERMINAL UNIT, VARIABLE /CANSTANi AIR VOLUME
AFR
—ABOVE FINISHED ROOF
MOD
—MOTOR OPERATED CONTROL DAMPER (MOD)
2. DIMENSIONS
SHALL. BE FIELD-VERIFIED AND COORDINATED PRIOR TO PROCUREMENT OR
•
CL
WITH ELECTRIC HEAT
1-04
FABRICATION.
COORDINATE THE WORK WITH OTHER TRADES INVOLVED. FIELD MODIFlCAl10NS
-ROUND DIFFUSER
-FIRE do SMOKE DAMPER
AHU
—AIR HANDLING UNIT
NC
— NORMALLY CLOSED
SUCH AS OFFSETS IN PIPING OR DUCTWORK (INCLUDING DIVIDED DUCTWORK) NEEDED DUE
(WITH ACCESS PANEL)
I I
AP
— ACCESS PANEL
TO OBSTRUCTIONS OR INTERFERENCES SFW1. BE PROVIDED AT NO ADDITIONAL COST. FOR
- CEILING RETURN
I i
L J
BOP
— BOTTOM OF PIPE
NO
— NORMALLY OPEN
TO SCALE
PROJECTS INVOLVING RENOVATION, COORDINATE NEW WORK WiTH EXISTING ELEMENTS SUCH
AS THE BUILDING STRUCTURE AND ARCHITECTURAL FEATURES, SPRINKLER PIPING, LIGHTS,
- EXISTING FiRE DAMPER TO REMAIN
�
BHP
—BRAKE HORSEPOWER
�
—NOT
PLUMBING, AND ELECTRICAL CONDUIT.
OA
— OUTSIDE AIR
® ---�`
- CEILING EXHAUST
- TERMINAL UNR, YARUIBIE /CONSTANT AIR VOLUME,
BTU
— BRITISH THERMAL UNIT
DAL
— OUTSIDE AIR LOUVER
3. DUCT
CONSTRUCTION SHALL BE IN ACCORDANCE WiTH THE LATEST EDfTiON OF THE
-EXISTING FiRE dt SMOKE DAMPER TO REMAIN
FAN POWERED
�
— CENTER LINE
SMACNA HVAG DUCT CONSTRUCTION STANDARD.
<< �
- CEILING DIFFUSER, RECTANGULAR OR
—CFM (CUBIC FEET PER MINUTE)
PRV
— PRESSURE REDUCING VALVE
4. SEE SPECIFICATIONS FOR GAUGES, THICKNESS, BRACING, REQUIREMENTS, ETC., OF DUCTWORK.
SQUARE NECK (CE]UNG DIFFUSERS
ORS
—PRESSURE REDUCING STATION
ARE 4-WAY THROW uNO)
SA-1
-SOUND ATfENUATOR
- TERMINAL UNIT, vARU1ELE /caNSTANT AIR VOLUME,
CD
— CEILING DIFFUSER
p�
— POUNDS PER SQUARE INCH
5, PROVIDE AIR TURNING VANES iN ALL 90 DEGREE RECTANGULAR DUCT ELBOWS.
FAN POWERED, WiTH ELECTRIC HEAT
�
- COOLING TOWER
I
- SUPPLY REGISTER OR GRILLE
(VERTICAL MOUNT, SIDEWALL)
_MOTOR OPERATED CONTROL DAMPER (MOD)
- ELECTRIC DUCT HEATER (W/ PANEL CLEARANCE)
T,y
- CONSTANT AIR VOLUME
PSIG
-PSI GAUGE
6. DUCT SIZES AND ALL OPENINGS THROUGH BUILDING CONSTRUCTION SHALL SUIT EQUIPMENT
FURNISHED.
PTAC
- PACKAGED TERMINAL AIR CONDITIONER
- --�•t-
-RETURN/EXHAUST REGISTER OR GRIME
CFM
-CUBIC FEET PER MINUTE
PVC
- POLYVINYL CHLORIDE PIPE
7. COORDINATE DIFFUSER, GRILLE AND REGISTER LOCATIONS WiTH ARCHITECTURAL REFLECTED
(VERTICAL MOUNT, SIDEI'YALL)
-AIR FLOW MEASURING STATION
i i
CU
- CONDENSING UNiT
RA
- RETURN AIR
CEILING PLANS AND EQUIPMENT OF ALL TRADES.
t r
L J
- REVISION REFERENCE
°
DDC
- DIRECT DIGITAL CONTROLS
RHG
— REHEAT COIL
8. LOCATE THERMOSTATS TEMPERATURE SENSORS HUMIDISTATS AND HUMIDITY SENSORS AT
L IS
- MANUAL BALANCING DAMPER
- HYDRONIC REHEAT COIL
DN
-DOWN
RHP
- ROOFTOP HEAT PUMP
'1B" ABOVE FINISHED FLOOR UNLESS NOTED OTHERWISE, COORDINATE LOCATIONS WiTH
t
° DETAIL REFERENCE: TOP - DETAIL,
EAT
- ENTERING AIR TEMPERATURE
OTHER
EQUIPMENT, FURNITURE. AND DOOR SWINGS.
M-t
BOTTOM - DRAWING# SHOWN ON
-DOOR GRILLE
RPM
- REVOLUTIONS PER MINUTE
g, /�
EQUIPMENT, DUCTWORK, ETC., SFiAtI BE SUPPORTED AS DETAILED AND /OR SPECIFIED.
(j
- THERMOSTAT/TEMPERATURE SENSOR
-INUNE CENTRIFUGAL FAN
ESP
— EXTERNAL STATIC PRESSURE
RS /L
— REFRIGERANT SUCTION dt LIQUID LINES
PROVIDE ADDITIONAL SUPPORTS AS REQUIRED TO PROVIDE A VIBRATION -FREE} RIGID
EWT
— ENTERING WATER TEMPERATURE
�
_ROOFTOP AIR HANDLING UNIT
INSTALLATION.
(�
- HUMIDISTAT /HUMIDITY SENSOR
vt=u
- UNDERCUT DaOR
- PACKAGED TERMINaL AlR CONDITIONER (PTAC)
FCU
—FAN COIL UNIT
SA
— SUPPLY AIR
10. ALL DUCT SIZES SHOWN ARE INSIDE CLEAR DIMENSIONS.
-DUCT SMOKE DETECTOR
FD
—FIRE DAMPER
SP
— STATIC PRESSURE
11. DAMPERS AND INSIDES OF DUCTS VISIBLE THROUGH GRILLES, REGISTERS AND DIFFUSERS
�----
- CONNECT TO EXISTING
i�
.
- ACCESS DOORS, VERTICAL OR HORIZONTAL
ti-
- CHANGE OF ELEVATION
�
—FINAL FILTERS
TSP
—TOTAL STATIC PRESSURE
SHALL BE PAINTED FIAT BLACK.
r
FLA
—FULL LOAD AMPS
UNa
- UNLESS NOTED OTHERWISE
12, REFER TO TYPICAL DETAILS FOR PIPING AND INSTALLATION OF EQUIPMENT.
�j--
-DEMOLISH TO POINT INDICATED
- STAINLESS STEEL DUCTWORK
- FLEXIBLE DUCT
FPM
-FEET PER MINUTE
Y /PH
- VOLTS/PHASE
13. TRAPPED CONDENSATE DRAINS FROM ALL MECHANICAL EQUIPMENT SHALL BE PROVIDED FOR
d—
- MOTORIZED CONTROL DAMPER
- FIEXiBLE CONNECTION
- TRANSITION, CONCENTRIC
GPM
- GALLONS PER MINUTE
VAY
- VARIABLE AIR VOLUME
PROPER DRAINAGE TO SUiT EQUIPMENT FURNISHED.
�—
TEMPERATURE SENSOR
KW
- KILOWATT
14. ACCESS PANELS IN DUCTWORK AND CEILINGS SHALL BE PROVIDED WHERE REQUIRED FOR
-
12x8 .e.
_FIAT OPAL DUCT
-TRANSITION, ECCENTRIC
VFD
- VARIABLE FREQUENCY DRIVE
OPERATION, BALANCING OR MAINTENANCE OF ALL. MECHANICAL EQUIPMENT.
[}—
- PRESSURE SENSOR
24x12 �
-NEW DUCTWORK, FIRST DIMENSION IS SIDE SHOWN
10x8
-TRANSITION, SQUARE TO ROUND
LAT
LWT
- LEAVING AIR TEMPERATURE
- LEAVING WATER TEMPERATURE
e p
- CHANGE IN PRESSURE
15. ALL DUCTWORK AND PIPING IS SHOWN SCHEMATICALLY. PROVIDE ALL TRANSITIONS, TURNING
AT
- CHANGE IN TEMPERATURE
VANES,
ELBOWS, FITTINGS, ETC., TO ALLOW SMOOTH FLOWS. All SPOT DUCT FITTINGS SHALL
��
- BACKDRAFT DAMPER
U)
-LINEAR DIFFUSER
TRANSITION TO FULL SIZE OF THE SUM OF BOTH BRANCHES, UPSTREAM OF SPLIT.
- NEUTRAL RELATIVE PRESSURE
24x12
-EXISTING DUCTWORK TO REMAIN
- SQUARE THROAT ELBOW
W/TURNING VANES
MBH
- THOUSAND BTUs PER HOUR
16. PROVIDE CONCRETE HOUSEKEEPING PAD UNDER ALL FLOOR-MOUNTED EQUIPMENT. REFER TO
�+
-POSITIVE RELATIVE PRESSURE
� 24x12 I
- EXISTING DUCTWORK TO BE REMOVED
SPECIFICATIONS FOR DETAILED REQUIREMENTS.
r_.,
Q
- NEGATIVE RELATIVE PRESSURE
-DUCT ELBOW, POSiTNE PRESSURE (SUPPLY)
"�I� ELBOW
17. VERIFY
LOUVERS
FINISH WITH ARCHITECT PRIOR TO PURCHASING GRILLES, REGISTERS, DIFFUSERS,
AND OTHER AIR DISTRIBUTION DEVICES.
�..
-SHEET NOTE CALLOUT
pOYVN UP W /IN FLOOR
18. PROVIDE
FLEXIBLE DUCT CONNECTIONS ON ALL DUCTWORK CONNECTING TO EACH FAN,
�j ----
-SHEET NOTE CALLOUT
-DUCT ELBOW, IXHAUST
RECTANGULAR/ROUND BRANCH TAKE-OFF
OR ROUND /ROUND BRANCH TAKE-OFF
AIR HANDLING UNITS, AND FAN COIL UNITS.
19, PROVIDE TRANSITIONS AT DIFFUSER NECKS AS REQUIRED T4 MATCH SIZES OF FLEX DUCTS
�---
-SHEET NOTE CALLOUT
-DUCT ELBOW, NEGATIVE PRESSURE, RETURN
TO
BE CONNECTED.
20. INTERRUPTIONS
TO EXISTING SERVICES SHALL BE SCHEDULED FOR TIMES OTHER THAN
®
- CEILING MOUNTED ACCESS DOOR
-DUCT ELBOW UP THROUGH ROOF OR SLAB ABOVE
.,� -r
`
- SQUARE THROAT TEE
NORMAL OPERATING HOURS (SUCH AS NIGHTS AND WEEKENDS). SUCH INTERRUPTIONS TO
HVAG EQUIPMENT
TAGS
SERVICES SHALL NOT BE MADE WITHOUT THE PRIOR WRITTEN CONSENT OF THE OWNER'S
REPRESENTATIVE AND PROPER COORDINATION WiTH OTHER TRADES, PRE-WORK SHALL BE
®
- RECTANGULAR DUCT SECTION UP, POSITIVE PRESSURE,
PERFORMED
TO MAKE THE SHUTDOWN PERIOD AS BRIEF AS POSSIBLE.
SUPPLY OR OUTSIDE AIR
®
- RECTANGULAR DUCT SECTION UP,
NEGATIVE PRESSURE, RETURN
12x8
- RADIUS TEE
TAG
21. ALL EQUIPMENT, DUCTWORK, ETC., TO BE REMOVED SHALL. REMAIN PROPERTY OF THE OWNER
OR DISPOSED OF LEGALLY, AS DIRECTED BY OWNER,
®
- RECTANGULAR DUCT SECTION UP, EXHAUST
A ZOO
-AIR DISTRIBUTION DEVICE
22. MAINTAIN CLEARANCE OF A MINIMUM OF 6" BETWEEN DUCTWORK, PIPING, EQUIPMENT, ETC.,
�CFM
AND ALL FIRE RATED AND FiRE /SMOKE RATED PARTTTiONS, TO AVOW FOR INSPECTIONS OF
-ROUND DUCT SECTION UP
�� Wes'•
-FIAT OVAL DUCT SECTION UP
- RECTANGLE TO -ROUND TAKEOFF
23. LOCATE All OUTSIDE AIR INTAKES A MINIMUM OF 25' -0" CLEAR FROM All PLUMBING VENTS
-°-1
�AHU NUMBER
AND EXHAUST AIR DISCHARGE LOCATIONS. LOWEST POINT OF EACH OUTSIDE AIR INTAKE ON
ROOF SHALL BE A MINIMUM OF 36" ABOVE ROOF.
i ®}
%
-EXHAUST DUCT UP THROUGH STAB W/
FAN ON ROOF ABOVE
- STANDARD BRANCH TAKEOFF
AHU-1
-AIR HANDLING UNiT
24. DUCT RUNOUTS TO DIFFUSERS SHALL MATCH THE SIZE OF THE DIFFUSER NECK.
-EXHAUST FAN ON ROOF W/ DUCT DOWN THROUGH ROOF
- SPIN -IN TAKEOFF
25. WATER PRESSURE DROPS THROUGH COIL CONTROL VALVES SHALL NOT EXCEED 5 PSI.
�,.•/
26. UNLESS OTHERWISE NOTED, ALL EQUIPMENT AND VALVE DRAINS SHALL BE INDEPENDENTLY
AHU NUMBER � /-COIL
NUMBER
PIPED FULL SIZE TO THE NEAREST PLUMBING DRAIN.
HVAG PIPING SYMBOL LEGEND
RHC -1-1
- REHEAT COIL
27. SLEEVE AND SEAL ALL PIPING PENETRATIONS THROUGH BUIIDiNG PARTITIONS. PROVIDE MANUAL
AIR VENTS AT ALL HIGH POINTS IN CHILLED WATER AND HOT WATER PIPING.
28. PIPING, DUCTWORK, LEAK PROTECTION APPARATUS, OR OTHER EQUIPMENT' FOREIGN TO
ELECTRICAL SWITCHBOARDS, PANELBOARDS, DISTRIBUTION BOARDS, OR MOTOR CONTROL
CENTERS SHALL NOT BE INSTALLED WITHIN THE REQUIRED SPACE FOR WORKING CLEARANCES
SYMBOL DESCRIPTION
SYMBOL DESCRIPTION
SYMBOL DESCRIPTION
VARIABLE /CONSTANT AIR VOLUME TERMINAL UNITS
CWS - CONDENSER WATER SUPPLY
-FLOW DIRECTION
CWR
CHWS
- CONDENSER WATER RETURN
-CHILLED WATER SUPPLY
—�
-�� V�-�
-BALL. VALVE
W
�
p_�yp
-SUN- VENT
TERMINAL UNiT TYPE
VTU - VARIABLE TERMINAL. UNIT
CTU - CONSTANT TERMINAL. UNIT
AHU NUMBER
Z':�: TERMINAL NUMBER
OR DEDICATED SPACES OF THE ELECTRICAL EQUIPMENT, EXTENDING IN FRONT OF AND FROM
FLOOR TO STRUCTURAL CEILING WiTH A WIDTH AND DEPTH OF THE ELECTRICAL EQUIPMENT IN
ACCORDANCE WITH NEC-110.26.
C
-CHILLED WATER RETURN
_ CALIBRATING BALANCING VALVE
PTU - PARALLEL TERMINAL UNiT V'i'u_1
_'
STU -SERIES TERMINAL UNIT
CD
-CONDENSATE
- BUTTERFLY VALVE
�
- PRESSURE GAUGE
CR
- CONDENSATE RETURN
'L
-GAS COCK
_ Fb1
-FLOW METER
PG
-PUMPED CONDENSATE
-UNION
M
_WAS M,�
HVAG DRAWING INDEX
HWR
-HOT WATER RETURN
-STRAINER
-INUNE PUMP
�
SHEET
DESCRIPTION
ISSUED
HWS
-HOT WATER SUPPLY
-CONTROL VALVE
-INUNE PUMP
HPS
-NIGH PRESSURE STEAM SUPPLY
�
- SOLENOID VALVE
_gyp
M -1
HVAG LEGEND, GENERAL NOTES, do SHEET INDEX
Yes
M -2
FIRST FLOOR DEMOLITION PLAN - DUCTWORK
Yes
MPS
-MEDIUM PRESSURE STEAM SUPPLY
-PSI REG.
- CONNECTION, BOTTOM
M -3
FIRST FLOOR PLAN - DUCTWORK
Yes
lPS
-LOW PRESSURE STEAM SUPPLY
-CHECK VALVE
- CONNECTION. TOP
HVAG DESIGN REQUIRES:
YES NO
M -4
SCHEDULES AND DETAILS -HVAG
Yes
HPR
-HIGH PRESSURE STEAM RETURN
Q
-FLOW SWITCH
DUCT SMOKE DETECTORS
.�
M -5
SPECIFICATIONS -HVAG
Yes
- COUPLING
MPR
- MEDIUM PRESSURE STEAM RETURN
-SLOPE DIRECTION (DOWN)
- ELBOW, 90'
FIRE DAMPER(S)
lPR
-LOW PRESSURE STEAM RETURN
-FLEX CONNECTION
ELBOW, 45
SMOKE DAMPER(S)
RL
- REFRIGERANT LIQUID
�
- O,S.dcY, GATE VALVE
�— � ®
- ELBOW, TURNED DOWN
FIRE RATED ENCLOSURE
•�
RS ---- --
- REFRIGERANT SUCTION
-� TRAP
a— �
-ELBOW, TURNED UP
FIRE RATED ROOF/FLOOR
-THREE-WAY CONTROL VALVE
CEILING ASSEMBLY
-1T�E, OUTLET DOWN
FIRE STOPPING
- THERMOMETER
�— �
-TEE, OUTLET UP
SMOKE CONTROL
-TWO -WAY CHECK VALVE
-45 PIPE RISE (R) /DROP (D)
-RELIEF VALVE
-PIPE ANCHORS
- CONCENTRIC REDUCER
-VALVE ON RISER
- ECCENTRIC REDUCER
NOTE: SOME SYMBOLS SHOWN ON THIS LEGEND MAY NOT PERTAIN TO THIS PROJECT
edward lewis
architects
9024 SW 152 STREET
PALMETTO BAY, FL 33157
PH: (305} 234-0576
EDWARD LEWIS ARCHITECTS, INC.
AAC001678
C. EDWARD LEWIS AR 0009567
255 S. Orange Avenue
Suite 1000
ftndo Fbmk 328M
IN r
Phone: 407- 841 -9050
ENGINEERING
Fax 407 -540 -0234
FOR ARCHITECTURE WWW.tic- engineers.conl
® Copyright 2010 TLC Engineering for Architec Lure, Ina,
EB JMM15 TLC NO:111355
Structural E"llnew
MTA
•� `1.: !•
N •C:• $qz
• 35067 •
• r
,m) OF r
ice S'^ o R t O•Q°•;;`�``,41
Revision ' * -*1411111111111% NA
Protect Nanbw
10 -038B
Date
MARCH, 2011
Shoot TIM
HVAG LEGEND
& SHEET INDEX
Dram bye ATT
Chocked bye DCB
Shoot: Nkunbw
i
i
R
LIL
r
•
•
•
,
•
W
LL
u
r
•
CL
1-04
r
r
i�
•
MTA
•� `1.: !•
N •C:• $qz
• 35067 •
• r
,m) OF r
ice S'^ o R t O•Q°•;;`�``,41
Revision ' * -*1411111111111% NA
Protect Nanbw
10 -038B
Date
MARCH, 2011
Shoot TIM
HVAG LEGEND
& SHEET INDEX
Dram bye ATT
Chocked bye DCB
Shoot: Nkunbw