11-853R-002i
S
�1'
r
It
LIFE SAFETY CALCULATIONS
SMOKE COMPARTMENT SUMMARY
U—)
i
SMOKE
COMPARTMENT
PRIMARY
USE
AREA
SF
OCCUPANT
LOAD FACTOR
PER PERSON
OCCUPANT
LOAD
V)
1A
TREATMENT
14,265
240 SF
60
U-
1B
TREATMENT
15,215
240 SF
64
-
HR
1 C
ASSEMBLY
BUSINESS
SUB —TOTAL
3,758
9,209
15 SF
100 SF
250
92
12,967
342
1D
TREATMENT
STORAGE
BUSINESS
SUB —TOTAL
1,995
3,343
9,340
240 SF
300 SF
100 SF
8
11
93
14,678
112
1E
KITCHEN
DINING
SUB —TOTAL
9,503
5,707
200 SF
11 SF
48
518
15,210
566
1F
MECH. EQ.
5,330
300 SF
18
1 G
TREATMENT
8,440
240 SF
35
1H
TREATMENT
5,905
240 SF
25
11
TREATMENT
7,195
240 SF
30
ii
TREATMENT
5,585
240 SF
24
1K
TREATMENT
7,775
240 SF
33
TOTAL - FIRST LEVEL
112,565
1,309
BUILDING INFORMATION
PROJECT INFORMATION
PROJECT NAME: BAPTIST HEALTH SOUTH MIAMI HOSPITAL
LIFE SAFETY SURVEY
ADDRESS: 6200 SW 73 STREET. SOUTH MIAMI. FL 33143
PROPOSED USE: LIFE SAFETY SURVEY
OWNER– CONTACT PERSON: LUIS FERNANDEZ DE CASTRO
PHONE: 786- 6624660
APPLICABLE CODES
– BUILDING CODE: 2007 FLORIDA BUILDING CODE W/2009
SUPPLEMENTS AND AIA GUIDELINES FOR
DESIGN AND CONSTRUCTION OF HOSPITALS
AND HEALTHCARE FACILITIES -2006 EDITION
–FIRE CODE: 2006 NFPA 1.- UNIFORM FIRE CODE /
FLORIDA FIRE PREVENTION CODE 2007
–LIFE SAFETY CODE: NPFA `101 – LIFE SAFETY CODE 2006
– ACCESIBILITY CODE: 2007 FLORIDA BUILDING CODE W/2009
SUPP EMENTS – CH.11
- -STATE FIRE MARSHALL'S RULE 69A3.012 FAC:
NFPA 10 -2002. STANDARD FOR PORTABLE
FIRE EXTINGUISHERS
NFPA 13- x2002, STANDARD FOR THE
INSTALLATION OF SPRINKLER SYSTEMS
NFPA 72 -2002, NATIONAL FIRE ALARM
CODE
NFPA 80 -1999 STANDARD FOR FIRE
DOORS AND FIRE WINDOWS
NFPA 99 -2005, STANDARD FOR HEALTH--
CARE FACILITIES
NFPA 105-2003, SMOKE CONTROL DOOR
ASSEMBLIES
NFPA 221 -2006, STANDARD ON FIRE
WALLS AND FIRE BARRIER WALLS
BUILDING PLANNING
OCCUPANCY: _INSTITUTIONAL GROUP 1 (FBC 2006)
MIXED OCCUPANCY? YES / NO
REQUIRED FIRE SEPARATION: 1 HR
TYPE OF CONSTRUCTION
CONSTRUCTION TYPE: FBC TYPE IB – NFPA 220
– TYPE II (2 -2 -2) __
LIFE & SAFETY NOTES
LIFE SAFETY PLAN LEGEND
1
HR
FIRE BARRIER
1
HR
SMOKE BARRIER
1
HR
FIRE BARRIER /SHAFT WALL
2
HR
FIRE BARRIER
2
HR
FSMOKE BARRIER
2
HR
BARRIER /SHAFT WALL
4
HR
FIRE BARRIER
SMOKE
PARTITION (NON RATED)
NON
RATED
EXIT ACCESS CORRIDOR
EXIT PASSAGE
2 HOUR
SUITE OF ROOMS
PERIMETER
INSTITUTIONAL
OCCUPANCY
BUSINESS
OCCUPANCY
ASSEMBLY
OCCUPANCY
AREA UNDER
CONSTRUCTION
SMOKE
COMPARTMENT
WALL
EXIT
EXIT SIGN — HATCH
INDICATES EXIT TEXT
AND ARROW
INDICATES DIRECTION
FIRE DEPARTMENT
CONNECTION
FIRE EXTINGUISHER CABINET
FIRE EXTINGUISHER
PULL STATION
STROBE LIGHT / HORN
TOTAL TRAVEL DISTANCE
TO AN EXIT
TRAVEL DISTANCE TO
ADJACENT SMOKE ZONE
— iii —�—
ME .�•-
FDC
0
FEC
FE
FX
200' -0"
200' -0 "
1. THIS PLAN WAS PROVIDED BY BHSF. E.L.A. TAKES NO RESPONSIBILITY FOR ITS ACCURACY BEYOND THE LIMITS OF CONSTRUCTION
AS DEFINED ON SHEET A2.0 & A3.0
2. THESE DRAWINGS HAVE BEEN DEVELOPED FROM EXISTING DRAWINGS WHICH MAY NOT REFLECT ACTUAL FIELD CONDITONS. THE
CONTRACTOR SHALL VERIFY THESE DRAWINGS WITH EXISTING FIELD CONDITIONS AND IMMEDIATELY NOTIFY THE ARCHITECT IN WRITING
OF INCONSISTENCIES BETWEEN THESE DRAWINGS AND ACTUAL CONDITIONS BEFORE PROCEEDING WITH CONSTRUCTION.
3. THE GENERAL CONTRACTOR SHALL VERIFY THAT CONSTRUCTION OF EXISTING WALLS MEETS THE FIRE PROTECTION RATINGS
DESIGNATED ON THESE DRAWINGS. HE SHALL ALSO MAKE ANY REPAIRS OR MODIFICATIONS NECESSARY TO BRING EXISTING WALLS,
DOORS, DUCTS, ETC. UP TO THE PROPER INDICATED FIRE PROTECTION RATING. DOORS AND /OR FRAMES NOT MEETING RATING
REQUIREMENTS OR BEARING PROPER LABELS SHALL BE REPLACED.
4. ALL CORRIDOR WALLS SHALL BE SMOKE TIGHT. THIS WILL BE ACHIEVED WITH DRYWALL TO DECK (ONE SIDE DRYWALL MINIMUM)
OR USING ONE POUND PER SQUARE FOOT ACOUSTICAL CEILING TILES.
5. WALLS NOTED "PARTITION TIGHT TO DECK" WITH SOUND BATTS SHALL HAVE DRYWALL ON BOTH SIDES. SEE THE REFLECTED
CEILING PLANS FOR SOUND BATTS LOCATIONS.
6. CONTRACTOR SHALL VERIFY THE LOCATION OF EXIT LIGHTS WITH OTHER LIGHTING TO ASSURE THERE ARE NO CONFLICTS OF EXIT
LIGHT LOCATIONS. SEE REFLECTED CEILING PLANS.
7. WALLS DESIGNATED TO BE "ONE SIDE TO DECK" SHALL BE "TWO SIDES TO DECK" AT ROOMS WITHOUT CEILINGS.
8. CONTRACTOR SHALL STENCIL THE WALL CLASSIFICATION IN RED LETTERS ABOVE THE FINISH CEILING ON EACH SIDE OF ALL RATED
PARTITIONS: FOR EXAMPLE: "TWO HOUR FIRE /SMOKE PARTITION — PROTECT ALL OPENINGS" SHALL OCCUR AT 20 "---0" O.C. BETWEEN
OBSTRUCTION OR AS DIRECTED BY ARCHITECT.
20. LIFE AND SAFETY LEGEND, NOTES AND CALCULATIONS
SCALE,1 /16 1 O
�,.
V � v
V V V V
JU„u uuu u
(: ) PARTIAL FIRST FLOOR LIFE AND .SAFETY PLAN A &,& FIRST FLOOR LIFE AND SAFETY PLAN 3 2 - -- SCALE :1 /16" = 1' -0" SCALE :1 /32" = 1' -0"
V
V
V V'V V V
N /E /P Engineer
Structural Engineer
A > co
V
U. " C
i0 0
O O
W J
W LL
Ol E-
m co r
C] U. H J
war,
a:.
Cl)
J W O
W W i
a ti Owl
® o
CO) J 2 C,:)
9
CL 3: cD
O
Seal , T
AR000944, 7'1�l ,;,,
a f'' 7
AR
57
i
RED ARG
Revision
L1.16.12 FIELD COORDINATION
2 2.3.12 FIELD COORDINATION
3 2.21.12 FIELD COORDINATION
Project Number
10 -038B
Date „
MARCH, 2011 ,
Sheet Title''
LIFE SAFETY:
4 .
P
LAN
Q S
Drawn bye ELA ar;`
ri w
cu checked bye ELEWIS
a Sheet Number
L r
0
6'L -