Loading...
11-853-014-0 `o E ev LO 0 co M T a_ Q) _C Cn I-, CL Li 0 0 Q) Ctf Q) Q) Q) >1 2 Q_ E UJ V) I 0 0 11f, U 0 MR NOTE: SOME SYMBOLS SHOWN ON THIS LEGEND MAY NOT PERTAIN TO THIS PROJECT 00 � 9024 SW 152 STREET PALMETTO BAY, FL 33157 PH: (305) 234-0576 EDWARD LEWIS ARCHITECTS, INC. AAC001678 C. EDWARD LEWIS AR 0009567 m/c/p L"moor IN255 S. Orange Avenue swte 1600 Orlando, Florida 32801 Phone: 407-841-9050 ENGINEERING Fax: 407-540-0234 FOR ARCHITECTURE www.tic- engineers.com a Copyright 2010 TLC Engineering for Architecture, Inc, EB #0000015 TLC NO:111403 Structural (Engineer PLUMBING SPECIFICATIONS PLUMBING FIXTURE SCHEDULE PLUMBING SYMBOL LEGEND PLUMBING ABBREVIATIONS z GENERAL NOTES._- M 0 SYMBOL DESCRIPTION SYMBOL DESCRIPTION 0- 1.00 - GENERAL PROVISIONS .J CA - COMPRESSED AIR CA - COMPRESSED AIR 0 FLOOR MOUNTED ACCESSIBLE WATER CLOSET 1. REFERENCE THE SPECIFICATIONS FOR MATERIAL AND EQUIPMENT INSTALLATION STANDARDS. 1.1 PROVIDE ALL LABOR, MATERIAL AND EQUIPMENT FOR A COMPLETE AND PROPERLY J LL rs 0 AFF - ABOVE FINISH FLOOR LL OPERATING PLUMBING SYSTEM. VITREOUS CHINA, 1.6 GALLON FLOOR MOUNTED, DIRECT-FED SIPHON JET, ELONGATED AV - - ® ® -- - ACID VENT AW - ACID WASTE 2. THE PLUMBING INSTALLATION SHALL COMPLY WITH ALL STATE AND LOCAL CODES. 1.2 CODES AND STANDARDS: ALL PLUMBING WORK SHALL COMPLY WITH THE REQUIREMENTS OF THE CLOSET BOWL WITH 1-1/2* TOP SPUD, FULLY GLAZED TRAPWAY, BOLT CAPS WITH RIM OF AW - ACID WASTE AV - ACID VENT 3. UTILITIES AND SERVICES INDICATED ARE TAKEN FROM VARIOUS OLD AND NEW J AMERICANS WITH DISABILITIES ACT (ADA) AND SHALL BE IN STRICT COMPLIANCE WITH • FIXTURE 17' A.F.F. AW---- - BELOW GROUND ACID WASTE CB - CATCH BASIN SURVEYS, AS-BUILT RECORDS AND FIELD INVESTIGATIONS. UNFORESEEN CONDITIONS THE FLORIDA BUILDING CODE (FBC): FBC PLUMBING CODE, 2007 ED. WITH 2009 REVISIONS, AND 1.6/1.1 GALLON DUAL-FLUSH CHROME PLATED FLUSH VALVE (EXPOSED), METAL CD - ABOVE GROUND CONDENSATE DRAIN CD - CONDENSATE DRAIN PROBABLY EXIST AND NEW WORK MAY NOT BE FIELD LOCATED EXACTLY AS SHOWN ON ALL LOCAL CODES HAVING JURISDICTION. DRAWINGS. COOPERATION WITH OTHER TRADES IN ROUTING AND BURIAL DEPTHS, AS STATE AND NATIONAL CODE REQUIREMENTS: CONFORM IN STRICT COMPLIANCE TO THE LATEST OSCILLATING NON-HOLD OPEN HANDLE, 1-INCH I.P.S. SCREW DRIVER ANGLE STOP WITH CD---- - BELOW GROUND CONDENSATE DRAIN CFH - CUBIC FEET PER HOUR DETERMINED DURING CONSTRUCTION, WILL BE NECESSARY. ENFORCED EDITION OF THE THE HANDICAP ACCESSIBILITY CODE, FLORIDA STATUTE, CHAPTER 553, PROTECTIVE CAP, ADJUSTABLE TAILPIECE, VACUUM BREAKER FLUSH CONNECTION AND CO - CLEANOUT PART V, 1990 REVISION; AND THE EDITIONS OF THE NFPA CODES AS FOLLOWS: SPUD COUPLING FOR 1-1/2' TOP SPUD, WALL AND SPUD FLANGES, SOLID RING PIPE DA - DENTAL AIR CONT - CONTINUATION 4. FIELD VERIFY EXISTING INSTALLATIONS. MODIFY EXISTING PLUMBING SYSTEMS, A. NFPA-13, STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS, 2002 SUPPORT, AND 2" OFFSET TO AVOID GRAB BAR, MOUNT FLUSH VALVE HANDLE MAX. 44* D1 - DEIONIZED WATER CW WHICH ARE TO REMAIN ACTIVE, TO FACILITATE RECONNECTION AND EXTENSION OF EDITION A.F.F.. - DOMESTIC COLD WATER THE NEW WORK. B. NFPA-70, NATIONAL ELECTRICAL CODE, 2005 EDITION DV - DENTAL VACUUM DI - DOONIZED WATER C. NFPA-90A, STANDARD FOR THE INSTALLATION OF AIR CONDITIONING AND CONTOURED SEAT SHALL BE EXTRA HEAVY SOLID PLASTIC W/ OPEN FRONT LESS COVER, - DOMESTIC COLD WATER DN - DOWN 5. NOTIFY OWNER AT LEAST 24 HOURS PRIOR TO INTERRUPTING EXISTING SERVICE. VENTILATION SYSTEMS, 2002 EDITION SEAT SHALL INCLUDE STAINLESS STEEL SELF SUSTAINING CHECK HINGE FEATURE. DS - DOWNSPOUT SCHEDULE DISCONNECTION AND TIE-INS TO MINIMIZE DISRUPTION OF SERVICES. D. NFPA-101, LIFE SAFETY CODE, 2006 EDITION - DOMESTIC HOT WATER SERVICES ARE NOT TO BE LEFT DISRUPTED DURING NON-NORMAL CONTRACTOR WORKING E. NFPA-99, 2005 EDITION BASIS OF DESIGN DWG - DRAWING HOURS. --- - DOMESTIC HOT WATER RECIRCULATING EXIST - EXISTING 1.3 ALL PLUMBING WORK SHALL BE DONE IN A NEAT AND WORKMANLIKE MANNER. CHINA - AMERICAN STANDARD - 3043.102 FOF - FUEL OIL FILL 'F - DEGREE FAHRENHEIT 6. PLANS ARE NOT COMPLETELY TO SCALE. PIPE ROUTING SHOWN IS SCHEMATIC AND IS FLUSH VALVE - SLOAN UPPERCUT - WES-115-1.6/1.1-YK-0 FCO - FLOOR CLEANOUT NOT INTENDED TO INDICATE EXACT ROUTING. CONTRACTOR SHALL PROVIDE ANY 1.4 CONTRACTOR SHALL SECURE AND PAY FOR ALL PERMITS AND FEES, ETC., REQUIRED SEAT - BEMIS - 1655-SS/C FOG -FUEL OIL GAGE ADDITIONAL OFFSETS AND FITTINGS REQUIRED FOR PROPER INSTALLATION AND TO MAINTAIN FOR THE EXECUTION OF THIS WORK. FOR - FUEL OIL RETURN FD - FLOOR DRAIN CLEARANCES. VERIFY STRUCTURAL, MECHANICAL AND ELECTRICAL INSTALLATIONS AND FOF - FUEL OIL FILL OTHER POTENTIAL OBSTRUCTIONS AND ROUTE PIPING TO AVOID INTERFERENCES. 1.5 CONTRACTOR SHALL COORDINATE HIS WORK WITH ALL OTHER TRADES BEFORE FOS - FUEL OIL SUPPLY FOG - FUEL OIL GAGE FABRICATION OR INSTALLATION. OFFSETS MD/OR TRANSITIONS REQUIRED SHALL BE E ACCESSIBLE WALL HUNG LAVATORY FOR 7. PROVIDE ALL OFFSETS AND FITTINGS AND MAKE CONNECTION TO SITE UTILITIES. PROVIDED WITHOUT ADDITIONAL COST. CONTRACTOR SHALL COORDINATE AND INSTALL FOV -FUEL OIL VENT -FUEL OIL RETURN HIS WORK IN A TIMELY MANNER TO PREVENT DELAYS IN THE CONSTRUCTION. VITREOUS CHINA LAVATORY, 20" X 18m, WITH FRONT OVERFLOW, SELF DRAINING DECK G - GAS FOS - FUEL OIL SUPPLY 8. CONCEAL PIPING ABOVE CEILINGS, WITHIN WALLS OR CHASES EXCEPT IN MECHANICAL AREA & CONTOURED BACK W/ SIDE SPLASH PANELS, PROVIDE FIXTURE PUNCHED FOR FOV - FUEL OIL VENT ROOMS OR AS SPECIFICALLY NOTED. 1.6 CONTRACTOR SHALL BE RESPONSIBLE TO REPAIR OR REPLACE DAMAGED EQUIPMENT COMBINATION FITTING ON 8-INCH CENTERS AND CONCEALED ARM CARRIER SUPPORT. GR - KITCHEN WASTE (GREASE) FS - FLOOR SINK AND/OR MATERIAL. A - MEDICAL COMPRESSED AIR G 9. PROVIDE ACCESS PANELS FOR ALL VALVES CONCEALED IN WALLS OR ABOVE 8" WIDESPREAD COMBINATION CHROME PLATED BRASS FAUCET, W/ RIGID GOOSENECK _GAS NON-ACCESSIBLE CEILINGS. 1.7 PROVIDE ALL MATERIALS REQUIRED TO PROPERLY SUPPORT ALL PIPING AND NOZZLE AND 1.4 GPM LAMINAR REGULATOR, VANDAL RESISTANT 4 INCH WRIST BLADE V - MEDICAL VACUUM GPH - GALLONS PER HOUR EQUIPMENT. PIPE HANGERS SHALL BE ADJUSTABLE TYPE AND BE SPACED IN HANDLES WITH COLOR CODED INDEXES AND RENEWABLE SEATS IN MONEL, OUTLET OF N - NITROGEN GPM - GALLONS PER MINUTE 10. SLEEVE AND/OR FIRESTOP ALL PENETRATIONS THROUGH RATED WALLS, CEILINGS, AND ACCORDANCE WITH THE STANDARD PLUMBING CODE. PROVIDED PLASTIC COATED RING SPOUT SHALL BE MINIMUM 5 INCHES ABOVE RIM OF FIXTURE. GR - KITCHEN WASTE (GREASE) FLOORS WITH U/L LISTED ASSEMBLIES. FIRESTOP ASSEMBLIES SHALL BE EQUAL TO OR ON HANGERS FOR COPPER PIPING TO PROVIDE DIELECTRIC ISOLATION. N20- - NITROUS OXIDE EXCEED THE RATING OF THE WALL, CEILING OR FLOOR. SEE ARCHITECTURAL DRAWINGS CHROME PLATED CAST BRASS GRID STRAINER WITH 1-1/4- O.D. OFFSET TAILPIECE, HB - HOSE BIBB FOR FINAL FINISHES. 1.8 PROVIDE DIELECTRIC UNIONS OR FLANGES BETWEEN COPPER AND STEEL PIPING AND CHROME PLATED 17 GAUGE 1-1/4- X 1-1/2- BRASS P-TRAP W/ C.O. PLUG AND SLIP P NP - - BL R NONPOTAE WRIER HD - HUB DRAIN BETWEEN BRASSWARE AND STEEL DO NOT USE STEEL AND COPPER PIPING IN THE NUTS. PROVIDE P-TRAP & TAILPIECE WITH PREWRAPPED SEAMLESS MOLDED CLOSED CELL 0 - OXYGEN HW - DOMESTIC HOT WATER 11. WHEN BEAM SLEEVE PENETRATIONS ARE NECESSARY, COORDINATE PENETRATIONS WITH SAME SYSTEM WITHOUT SUCH ISOLATION. VINYL INSULATION WITH FLEXIBLE COLLARS TO ALLOW PIPE CONNECTION. PRE-WRAPPED HWR - DOMESTIC HOT WATER RECIRCULATING ALL TRADES, THE ARCHITECT AND THE STRUCTURAL ENGINEER. DRAIN INSULATION KIT SHALL INCLUDE HOT AND COLD ANGLE STOP AND WATER SUPPLY S - ABOVE GROUND SANITARY IE - INVERT ELEVATION 1.9 PROVIDE REDUCING FITTINGS (REDUCING BUSHINGS SHALL NOT BE USED) WHERE COVERS OF SAME MATERIAL 12, PROVIDE FOUNDATION PAD PENETRATION SLEEVES. ALLOW 1' MINIMUM CLEARANCE CHANGES IN PIPE SIZES OCCUR. ____S__ - BELOW GROUND SANITARY 1W - INDIRECT WASTE BETWEEN SLEEVE INSIDE SURFACE AND PIPE EXTERIOR. 3/8- I.P.S. CHROME PLATED ANGLE SUPPLY, LOOSE KEY STOP, REDUCER, WROUGHT ®!- - - -_!!!! °- - SANITARY VENT KW - KILOWATT 1.10 THIS CONTRACTOR SHALL SUPPLY AND INSTALL ALL SERVICES THROUGHOUT THE BRASS DEEP BELL FLANGE ESCUTCHEON AND 1/2' CHROME PLATED COPPER EXTENSION LBS - POUNDS 13. SEE ARCHITECTURAL DRAWINGS FOR FIXTURE LOCATIONS AND MOUNTING HEIGHTS. BUILDING AND MAKE CONNECTION TO SITE UTILITIES APPROXIMATELY 5' -0* OUTSIDE THE TUBE. ST - ABOVE GROUND STORM BUILDING. CONTRACTOR SHALL SUPPLY AND INSTALL FIXTURES, FITTINGS, VAI.VING AND ST - BELOW GROUND STORM A - MEDICAL AIR 14. ALL EXPOSED PIPE AND FITTINGS IN FINISHED AREAS SHALL BE CHROME PLATED. TRIM AND MAKE READY FOR USE ALL FIXTURES, EQUIPMENT, ETC. CONCEALED ARMS FLOOR MOUNTED CARRIER: COATED STEEL UPRIGHTS WITH WELDED FEET, V - MEDICAL VACUUM CAST IRON ADJUSTABLE HEADERS, STEEL SLEEVES, ALIGNMENT TRUSS AND FASTENERS STO - OVERFLOW STORM DRAIN MH - MANHOLE 15. PROVIDE CLEANOUTS IN ACCORDANCE WITH ALL STATE AND LOCAL CODES. INSTALL 1.11 SEE ARCHITECTURAL DRAWINGS FOR FIXTURE LOCATIONS AND MOUNTING HEIGHTS. STO - BELOW GROUND OVERFLOW STORM N - NITROGEN CLEANOUT WITH COVER FLUSH TO FINISH SURFACE. 2.00 - BASIC MATERIALS AND METHODS BASIS OF DESIGN BASIS SW - SOFT COLD WATER N20 - NITROUS OXIDE 16. COORDINATE PIPING WITH ALL ELECTRICAL EQUIPMENT (PANELS, TRANSFORMERS, ETC.) CHINA -AMERICAN STANDARD - 0356.015 VA - VACUUM (AIR) NC - NORMALLY CLOSED PRIOR TO ANY INSTALLATION. DO NOT ROUTE ANY PIPING OVER ANY ELECTRICAL 2.1 ABOVEGROUND WATER PIPE AND FITTINGS - TYPE I" COPPER. FAUCET - T&S BRASS MODEL B-2866-05- U`08-QT WITH B-LT NIC - NOT IN CONTRACT PANELS UNDER ANY CIRCUMSTANCES. ANY PIPING RUN OVER PANELS SHALL BE STRAINER/TRAP - MCGUIRE -155WC/PW 2150 WC VC - VACUUM CLEANING NO - NORMALLY OPEN RE-ROUTED AT NO ADDITIONAL COST. 2.2 PROVIDE UNIONS OR FLANGES IN ALL DOMESTIC WATER SERVICE LINES AT EACH PIECE SUPPLIES - MCGUIRE - H170LK OF EQUIPMENT, SPECIALTY VALVES OR AT OTHER LOCATIONS REQUIRED FOR READY CARRIER - JOSAM 17100-67 WO - WASTE OIL NP - NON-POTABLE WATER 17. ALL WALL MOUNTED LAVATORIES SHALL BE ATTACHED TO FLOOR MOUNTED CARRIER DISCONNECT. WOV - WASTE OIL VENT NTS - NOT TO SCALE DESIGNED TO WITHSTAND A VERTICAL LOAD OF 250 POUNDS ON THE FRONT OF THE 0 - OXYGEN FIXTURE. 2.3 WATER HAMMER ARRESTORS SHALL BE INSTALLED AT THE LOCATIONS ON THE PLANS - WATER METER OD AND IN ACCORDANCE WITH PDI STANDARD WH-201. PRODUCTS SHALL BE EQUAL TO E SMALL HAND WASH SINK HC - OUTSIDE DIAMETER 18. PROVIDE SANITARY WASTE, VENT, DOMESTIC WATER, ETC. ROUGH-IN AND MAKE FINAL THOSE MANUFACTURED BY PRECISION PLUMBING PRODUCTS OR SIOUX CHIEF. -HOSE BIBS OR WALL HYDRANT PRV - PRESSURE REDUCING VALVE CONNECTIONS (TO INCLUDE PROVIDING ALL NECESSARY RELATED STOPS, VALVES, TRAPS, SINGLE COMPARTMENT SELF RIMMING SINK CONSTRUCTED OF TYPE 302 18-8 STAINLESS co H - CLEAN OUT PLUG PSI - POUNDS PER SQUARE INCH ETC. AND MAKE READY FOR USE) TO ALL EQUIPMENT, WHETHER FURNISHED BY THIS 2.4 VALVES: PROVIDE VALVES TO ISOLATE EACH RISER, BRANCH LINE AND PIECE OF STEEL, 17' X 15" X 7-1/2' DEEP. INTERIOR AND TOP SURFACES SHALL BE POLISHED PVC - POLYVINYL CHLORIDE PIPE CONTRACTOR OR FURNISHED BY OTHERS. EQUIPMENT. TO A HIGH LUSTER FINISH. PROVIDE SINK WITH STAINLESS STEEL CRUMB CUP STRAINER. CO 1 co - WALL CLEANOUT PROVIDE FIXTURE PUNCHED FOR 3-HOLE FAUCET INSTALLATION ON 4-INCH CENTERS. -FLOOR CLEAN OUT RD - ROOF DRAIN 19. PROVIDE CERTIFIED COPY OF MEDICAL GAS TEST REPORT AT FINAL A.H.C.A, INSPECTION. 2.5 CAST IRON SOIL PIPE, SERVICE WEIGHT WITH NO-HUB COUPLINGS. NO-HUB COUPLINGS RPBP - REDUCED PRESSURE BACKFLOW PREVENTOR SHALL MEET FACTORY MUTUAL RESEARCH CORPORATION (FRMC) STANDARD 1680-89. 8-INCH WIDESPREAD COMBINATION CHROME PLATED BRASS FAUCET, WITH RIGID GOOSENECK FD 0:- FD SC- - FLOOR DRAIN SAN - SANITARY (5-3/8- WIDE) SPOUT AND 1.4 GPM LAMINAR FLOW REGULATOR, VANDAL. RESISTANT 4-INCH - ROOF DRAIN SD - STORM DRAIN 3.00 - PLUMBING FIMRES AND TRIM WRIST BLADE HANDLES WITH COLOR CODED INDEXES AND RENEWABLE SEATS IN MODEL, OUTLET OF SPOUT TO BE MINIMUM OF 5- INCHES ABOVE RIM OF FIXTURE. FS - FLOOR SINK SF - SQUARE FEET 3.1 ALL PLUMBING FIXTURES SHALL BE "FIRST QUALITY" AS DEFINED AND SET FORTH IN SH - SHEET COMMERCIAL STANDARD CS77-28 AS PROMULGATED BY THE U.S. DEPARTMENT OF 3/8 INCH I.P.S. CHROME PLATED ANGLE SUPPLY, LOOSE KEY STOP, REDUCER, WROUGHT VC 0 - VACUUM CLEANING OUTLET (FLOOR) ST - STORM COMMERCE. BRASS DEEP BELL FLANGE ESCUTCHEON AND 1/2- CHROME PLATED COPPER EXTENSION Y_Q Ille - VACUUM CLEANING OUTLET (WALL) STO - OVERFLOW STORM DRAIN TUBE WITH SWEAT CONNECTION. 3.2 ALL FIXTURES ARE TO BE WHITE VITREOUS CHINA UNLESS OTHERWISE SPECIFICALLY - SHUT-OF VALVE IN VALVE BOX SW - SOFT COLD WATER NOTED. CHROME PLATED 17 GAUGE 1-1/2' X 1-1/2* P-TRAP WITH CLEANOUT. - SHUTOFF VALVE V - VENT VAC - VACUUM 3.3 FIXTURES AND FITTINGS PROPOSED SHALL BE FROM ONE MANUFACTURER AND OF BASIS OF DESIGN 01 - BALL VALVE VC - VACUUM CLEANING SIMILAR CHARACTER IN ANY ROOM OR LOCATION. ESCUTCHEONS, HANDLES, ETC., ON - CALIBRATED BALANCING VALVE VTR THE DIFFERENT FIXTURES SHALL BE OF THE SAME DESIGN. SINK - ELKAY BLR-1517/LK-99 -VENT THRU ROOF FAUCET - T&S BRASS MODEL B-2866-05-LFO8 -QT WITH B-LT - CHECK VALVE (SWING) WCO - WALL CLEANOUT PLUMBING 3.4 PROVIDE FIXTURE CARRIERS AS RECOMMENDED BY FIXTURE MANUFACTURER AND/OR SUPPLIES - MCGUIRE - H170LX WTR - WATER DRAWING INDEX CONSTRUCTION METHOD. TRAP - MCGUIRE - 8912 - PRESSURE REDUCING VALVE SHEET DESCRIPTION ISSUED - SOLENOID OPERATED VALVE 3.5 PROVIDE ACCESS PANELS TO ALL VALVES WITHIN CHASES OR ABOVE NON-ACCESSIBLE CEILINGS. REFER TO ARCHITECTURAL DRAWINGS FOR CEILING TYPES. - REDUCED PRESSURE BACKFLOW PREVENTER P-1 LEGEND, NOTES - PLUMBING YES 3.6 ALL CONCEALED TRAPS, PRIMERS, VALVES, CLEANOUTS, ETC. LOCATED IN TILED AREAS - RELIEF OR SAFETY VALVE P-2 FIRST FLOOR PLAN - GRAVITY PIPING YES SHALL BE PROVIDED WITH AN ACCESS PANEL. - GAS COCK P-3 FIRST FLOOR PLAN - PRESSURE PIPING YES 4.00 - INSULATION - GAS PRESSURE REGULATOR P -4 FIRST FLOOR PLAN - MEDICAL GAS PIPING YES 4.1 ABOVE GROUND HOT WATER AND HOT WATER RETURN - FIBERGLASS, 1* THICKNESS, ASJ JACKET, oc - SHUTOFF VALVE ON RISER P-5 PLUMBING DETAILS YES DOUBLE SEALING LAP JOINT, 0.24 K AT 75T. INSULATION AND ADHESIVES INSTALLED IN RETURN rG - GAS COCK ON RISER AIR PLENUMS SHALL HAVE A MAXIMUM FLAME SPREAD RATING OF 25 AND A MAXIMUM SMOKE DEVELOPED RATING OF 50. - CONNECTION, TOP - CONNECTION, BOTTOM 5.00 - VALVES AND COCKS G - ELBOW, TURNED DOWN 5.1 VALVES 2" AND SMALLER SHALL BE BALL VALVES, 150 PSI SWP, 400 PSI WOG. STANDARD 0 - ELBOW, TURNED UP PORT BALL, BRONZE TRIM, CAST BRONZE BODY, CHROMIUM-PLATED BRASS BALL, 0 - TEE, TURNED UP BRONZE NON-BLOWOUT STEM, TEFLON SEAT, DOUBLE O -RING STEM SEALS, ZINC-COATED STEEL HANDLE WITH PLASTIC COATED HAND GRIP, 90 DEGREE OPERATION FROM FULL 9 -TEE, TURNED DOWN OPEN TO TIGHT SHUT-OFF - STOCKHAM S214-BR-T-T, STOCKHAM S216 -BR -TS OR EQUAL. G A - C'. D no - DIRECTION OF FLOW 6.00 - STERILIZATION im AP­XX -ALARM PANEL 6.1 DOMESTIC WATER PIPING SHALL BE THOROUGHLY FLUSHED OUT AND STERILIZED IN im MAP-XX - MASTER ALARM PANEL ACCORDANCE WITH THE FBC PLUMBING CODE. MGO-X - MEDICAL GAS OUTLET MGV-XX - MEDICAL GAS VALVE BOX - CONNECT TO EXISTING qw - DEMOLISH TO POINT INDICATED - REVISION REFERENCE DETAIL REFERENCE: TOP­DETAJL#, G BOTTOM-DRAWING# SHOWN ON NOTE: SOME SYMBOLS SHOWN ON THIS LEGEND MAY NOT PERTAIN TO THIS PROJECT 00 � 9024 SW 152 STREET PALMETTO BAY, FL 33157 PH: (305) 234-0576 EDWARD LEWIS ARCHITECTS, INC. AAC001678 C. EDWARD LEWIS AR 0009567 m/c/p L"moor IN255 S. Orange Avenue swte 1600 Orlando, Florida 32801 Phone: 407-841-9050 ENGINEERING Fax: 407-540-0234 FOR ARCHITECTURE www.tic- engineers.com a Copyright 2010 TLC Engineering for Architecture, Inc, EB #0000015 TLC NO:111403 Structural (Engineer Don C. Bailey, P.E. orioa License #35067 RevIslon a6vzpr'-�io m lw',W Project Number 10-036B Date MARCH, 2011 Sheet intie LEGEND, NOTES PLUMBING Drawn bye NRK Chocked bys UPS Shoot Number P -1 z 0 z :3 M 0 5; 0- 4 0 .J • UJ 0 0. • J JJJ J LL rs 0 M LL z O.J F_ CO) 2 J • w X UJ IL w >_ C, 0 CL W Don C. Bailey, P.E. orioa License #35067 RevIslon a6vzpr'-�io m lw',W Project Number 10-036B Date MARCH, 2011 Sheet intie LEGEND, NOTES PLUMBING Drawn bye NRK Chocked bys UPS Shoot Number P -1