11-831-011a 5ECTION A SCALE: 11411 =1' -0" Rl pff% SNORING x 1 -6" 00 (OR EQ.) )RES AT 100% %S SHOWN ON I AS REQ'D. BY ,u SECTION e SCALE= 1/4 " =I' -0" Ri NOTE: RESHORE CONDITIONS AND EQUIPMENT VARY. READ ALL THE NOTES CAREFULLY. ME SHORMG ;S -611 ,00 (OR EQ ) )RES AT 100% �S SHOWN ON l AS REQ'D. BY V NOTE: WHERE PRIMARY SHORE POSTS LAND WITHIN 12" OF EACH OTHEF THE CONTR. MAY USE (1) RESHOF POST LOCATED BETWEEN THE TI SEE SNORING PLAN BY OTHERS - rr R SECTION c WALE- 114"=V-0" t t t I MY SHORING THEIRS i +29' -6" 20 -500 (OR EQJ SHORES AT 100% PT AS SHOWN ON "LAN w 0 20 -500 (OR EQ) SHORES AT 1009 :PT AS SHOWN ON "LAN ILLS AS REQ'D. BY R. I i i� i i i I t i i F P HIGH ROOF POUR RESHORE CHECK: 150 PCF X 916'1' + 1315 PSF (CONC. DL) + 50 PSF (CONSTR. LL) + 10 PSF (FORMS) 1915 PSF (TOTAL) POUR DAY LOAD + (2) SLA5SS CONE LVL OF RESHORE) 98.15 PSF / FLOOR (PER ACI 341) >90 PSF (LL + SOL) ALLOWED - RESHORE TO GROUND - SEE RESHORE ANALYSIS ASSUMPTION NOTE 04. THIS SHORE / RESHORE DRAWING IS BASED ON STRUCTURAL DRAWINGS DATED 12 -3-10 IT IS THE CONTRACTORS RESPONSIBILITY TO REVIEW THIS DRAWING WITH THE FINAL C4)NST?CTI0N DOCUMENTS AND CONTACT DARSCO ENGINEERING, LLC. IF DISCREPANCIES ARE FOUND PRIOR TO COMMENCEMENT OF WORK Q SAMUEL A. GREENBERS, P.E. 034245 4 D, IRWIN J. BENSON, P.E. 049156 ,°yyy4 6n Q ANiDRE,U D. HAROLD, P.E. X06 -t15 RESHORING ANALYSIS ASSUMPTION NOTES 3: 1) THE STRUCTURAL FLOOR SLAB BELOW THE FLOOR BEING PLACED MI'PT -PE ALL.OK-D- TO- DEFLECTAN ---- � ORDER TO SUPPORT IT'S OMAN DEAD WEIGHT. THEREFORE, THE FLC7R BELOW THE POC7 MUr? BE - � ,► STRIPPED AND RESHORED PRIOR TO SUBSEQUENT SLAB POURS. ENGINEERING, LLC P.O. BOX 3400 - APOLLO BEACH - FLORIDA - 33512 2) FORMWORK MUST BE STRIPPED IN LARGE AREAS (SEVERAL BAYS A" - — IME) ^TO- iLl�.(4 THE FMM4 PHONE - (813) 645 0166 PAX - (813) 645 9698 SLABS AND BEAMS TO DEFLECT EQUALLY AND SUPPORT THEIR OWN DEAD WEIGHT CA 25948 3) RESHORES TRANSMIT NO SIGNIFICANT LOADS BETWEEN FLOORS PRIOR TO CONCRETE POUR. rnl Tiff$ DRAW= AND DESIGNS AM THE XW PROPERTY OF DW= DMOM L1.0 M THE V CUNT ON THIS PRUCT. ANY REPRODUCTION OR tNAUM OFM USE IS PRONBTED. - 1011 4) THE LIVE LOAD CAPACITY OF EACH FLOOR IS NOT UTILIZED WHEN RESHORED TO THE GROUND. THE ` RESHORES ARE ASSUMED TO TRANSMIT ALL LOADS DIRECTLY TO THE GROUND. co 5) EACH FLOOR IS STRUCTURALLY CAPABLE OF TRANSMITTING POINT LOADS ( RESHORES) TO THE SCALE NOTED SUPPORTING BEAMS AND COLUMNS. DRAWN PER 6) THE PRIMARY (ACTIVE) SHORING SYSTEM IS PARTIALLY RESTRAINED BY PREVIOUSLY PLACED AND DATE 1 -15 -11 MIAMI, FL. STRIPPED STRUCTURAL COLUMNS AND /OR WALLS _ � 4.1l.iE �` R ft / 7) THIS RESHORING IS DESIGNED TO CARRY: THE DEAD LOAD OF THE WET CONCRETE, °, PLUS 50 PSF CONSTRUCTION LIVE LOAD (ON THE WET DECK ONLY) AND 10 PSF FORMWORK DEAD LOAD, F t AND WTHIWG ELSE INCLUDING THE STOCKING OF MATERIAL ON ANY SLAB 310604 -R3 ENGAGED BY THE SHORING, U.N.O. GENERAL NOTES 1) RESHORE CUPS OR PLYWOOD SPRINGBOARDS, OR LACING SHALL BE USED ON ALL POST RESHORES ABOVE GROUND LEVEL TO PREVENT LOOSENING FROM CHANGING CONSTRUCTION LOADS ABOVE. 2) DURING THE STRIPPING PROCESS, SLABS AND BEAMS SHALL NOT BE LEFT UNRESHORED OVERNIGHT. 3) NO AREA IS TO BE POURED UNTIL ALL RESHORES ARE IN PLACE DIRECTLY BELOW THE AREA. 4) POST RESHORES ABOVE GROUND LEVEL ALONG THE PERIMETER OF THE BUILDING ARE TO BE LACED TO ADJACENT RESHORES (1 ROW PARALLEL TO SLAB EDGE — MINIMUM) TO PREVENT THEIR FALLING OUT OF THE BUILDING FROM INADVERTENT CONTACT OR CHANGING LOADS ABOVE. 5) CONTRACTOR MALL UTILIZE STEEL OR ALUMINUM POST SHORES THAT CAN SUPPORT 7,500 LBS. AT THE REVD. EXTENSION UNDER STEEL SHORE FRAMES AND 12,000 LOS. AT THE REO'D. EXTENSION UNDER TRUSS TABLE LEGS (WHERE APPLICABLE) ACC( RIMNG TO THE MANUFACTURERS SPECIFICATIONS. 6) ALL WOOD SHALL BE #2 SO. YELLOW PINE OR BETTER MATH AN Fb OF AT LEAST 1450 PSI. LUMBER SHALL BE IN GOOD CONDITION WITH NO LOOSE KNOTS AND HAVE AT LEAST 85% OF ITS NET CROSS SECTION AT ANY POINT ALONG THE MEMBER. SHAKES, CHECKS, AND SPLITS SHALL CONFORM TO VISUAL GRADING REQUIREMENTS OF THE SOUTHERN PINE INSPECTION BUREAU GRADING R I F , SECTION 300, 2002 EDITION. 7) MUDSILL DESIGN BY OTHERS U.N.O. MUDSILLS ARE NOT REQUIRED IF SLAB ON GRADE HAS BEEN PLACED PRIOR TO ERECTING THE RESHORES. 8) ALL RESHORE EQUIPMENT MUST BE IN GOOD CONDITION, FREE OF DELETERIOUS RUST, DENTS. BROKEN WELDS, OR OTHER MAJOR DEFECTS. 9) CONTRACTOR TO VERIFY THAT SHORE FRAMES CAN SUPPORT A MINIMUM OF 10,000 LEIS PER LEG. 10) CONTRACTOR TO VERIFY ALL DIMENSIONS IN THE FIELD. 11) POST SHORES MUST BE VISIBLY PLUMB. " 12) THIS SHORING IS DESIGNED FOR USE MATH PER[ FORMWORK INC. EQUIPMENT. THE CONTRACTOR IS RESPONSIBLE FOR FOLLOWING SUPPLIERS' RECOMMENDATIONS FOR SAFETY, ERECTION, AND STRIPPING OF THEIR SHORING EQUIPMENT AND FOR VERIFYING THE EQUIPMENT LOAD CAPACITIES. 13) THE CONTRACTOR SHALL CONSULT DANSCO ENGINEERING, LLC PRIOR TO USING MOTORIZED FORM HANDLING OR FINISHING EQUIPMENT SUCH AS FORKLIFTS AND RIDING TROWELS. 14) SHORING LEFT IN PLACE AS RESHORES MUST HAVE ALL THE TOP SCREWS OR JACKS RELEASED. THEN, AFTER RELEASING ALL THE TOP SCREWS AND JACKS, RE— TIGHTEN ALL THE SHORING TO . THE SLAB OR BEAM SOFFITS PRIOR TO PLACING THE LEVEL ABOVE. 15) THE CONTRACTOR SHALL CHECK THE SPECIFICATIONS AND VERIFY THAT KQ LIVE LOAD REDUCTIONS HAVE BEEN TAKEN PRIOR TO USING THIS RESHORING AS DESIGNED. 16) THE CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLIANCE WITH OSHA REQUIREMENTS REGARDING FALL PROTECTION DURING ERECTION, USE. AND DISMANTLING OF THE SHORING EQUIPMENT AND FORMWORK SHOWN IN THESE DRAWINGS. HIGH ROOF POUR RESHORE CHECK: 150 PCF X 916'1' + 1315 PSF (CONC. DL) + 50 PSF (CONSTR. LL) + 10 PSF (FORMS) 1915 PSF (TOTAL) POUR DAY LOAD + (2) SLA5SS CONE LVL OF RESHORE) 98.15 PSF / FLOOR (PER ACI 341) >90 PSF (LL + SOL) ALLOWED - RESHORE TO GROUND - SEE RESHORE ANALYSIS ASSUMPTION NOTE 04. THIS SHORE / RESHORE DRAWING IS BASED ON STRUCTURAL DRAWINGS DATED 12 -3-10 IT IS THE CONTRACTORS RESPONSIBILITY TO REVIEW THIS DRAWING WITH THE FINAL C4)NST?CTI0N DOCUMENTS AND CONTACT DARSCO ENGINEERING, LLC. IF DISCREPANCIES ARE FOUND PRIOR TO COMMENCEMENT OF WORK +k; % 'T► s Q SAMUEL A. GREENBERS, P.E. 034245 4 D, IRWIN J. BENSON, P.E. 049156 ,°yyy4 6n Q ANiDRE,U D. HAROLD, P.E. X06 -t15 THUY HUYN-I, P.E. %0122 D ANSCO ENGINEERING, LLC P.O. BOX 3400 - APOLLO BEACH - FLORIDA - 33512 PHONE - (813) 645 0166 PAX - (813) 645 9698 CA 25948 rnl Tiff$ DRAW= AND DESIGNS AM THE XW PROPERTY OF DW= DMOM L1.0 M THE V CUNT ON THIS PRUCT. ANY REPRODUCTION OR tNAUM OFM USE IS PRONBTED. - 1011 ` SOUTH MIAMI HOSPITAL EXPANSION co SCALE NOTED DRAWN PER .•L� DATE 1 -15 -11 MIAMI, FL. � 4.1l.iE �` R ft / RESHORE SECTIONS °, F t BUILDECON 310604 -R3 +k; % 'T► s 4 ,°yyy4 6n +k; % 'T► s