11-671-007
GENERAL ELECTRICAL SYMBOL LEGEND FIRE DETECTION AND ALARM SYMBOLS 0 l__� LOCATION OF SUBSCRIPT, X NOTE: THE FOLLOWING SUBSCRIPTS ARE USED TO INDICATE VARIOUS TYPES OF FIRE ALARM STATIONS (NO SUBSCRIPT) MANUAL STATION SPEAKER /HORN AND STROBE LIGHT COMBINATION UNIT ® STROBE LIGHT &A SPEAKER ®X /LOCATION OF SUBSCRIPT. SMOKE DETECTOR NOTE: THE FOLLOWING SUBSCRIPTS ARE USED TO INDICATE VARIOUS TYPES OF SMOKE DETECTORS (NO SUBSCRIPT) PHOTOELECTRIC D . FOR DUCTWORK A SINGLE STATION WITH AUXILIARY CONTACT 120VAC, 9 VOLT BATTERY BACK -UP E WITH AUXILIARY CONTACTS FOR ELEVATOR RECALL w� X�LOCATION OF SUBSCRIPT. UTOMATIC HEAT DETECTOR NOTE: THE FOLLOWING SUBSCRIPTS ARE USED TO INDICATE VARIOUS TYPES OF HEAT DETECTORS (NO SUBSCRIPT) FIXED TEMPERATURE, 136 DEC. H FIXED TEMPERATURE, 190 DEC. C COMBINATION, 136 DEG. 0] INPUT /OUTPUT INTERFACE MODULE ® FAN SHUTDOWN RELAY �J POWER AND DIAGRAMS W.P. 15A,125V,2 POLE, 3 WIRE GROUNDING WITH FUSIBLE DISCONNECT SWITCH DUPLEX RECEPTACLE, WHITE, NEMA 5 -15R TYPE 8 INDICATED.QTY & LENGTH AS SHOWN. 15A,125V,2 POLE, 3 WIRE GROUNDING DOOR SWITCH DUPLEX RECEPTACLE, WHITE, NEMA 5 -15R MISCELLANEOUS SYMBOLS TOP HALF SWITCH NOTE: THE FOLLOWING SUBSCRIPTS ARE USED TO 20A, 125V, 2 POLE, 3 WIRE GROUNDING INDICATE VARIOUS TYPES OF SWITCHES DUPLEX RECEPTACLE, WHITE, NEMA 5 -20R LIGHTING GFI TYPE DUPLEX RECETACLE Q BUILT N GROUND FAULT INTER UIPTION, THREE WAY ABOVE COUNTER OR 48" AFF. CEILING LIGHT OUTLET W /FIXTURE 5MA, 15A, 125V, 3 WIRE WHITE 1-0 15A,125V,2 POLE, 3 WIRE GROUNDING HORSEPOWER MOTOR QUAD RECEPTACLE, WHITE, NEMA 5 -15R 0 20A, 125V, 2 POLE, 3 WIRE GROUNDING LIGHTED HANDLE SINGLE RECEPTACLE, WHITE, NEMA 5 -20R KEY OPERATED GFI TYPE DUPLEX RECEPTACLE WITH =I BUILT IN GROUND FAULT INTERRUPTION, CEILING MOUNTED MOTION SENSOR 5MA, 15A, 125V, 3 WIRE, WHITE ® FLOOR MOUNTED RECEPTACLE 15A, RECOVERY 125V, 3 WIRE, GROUNDING TYPE, WHITE, 4. NEMA 5 -15R BY WIREMOLD 8800 SERIES. O CEILING MOUNTED JUNCTION BOX WITH COVER U.O.N. K� WALL MOUNTED JUNCTION BOX WITH COVER U.O.N. 20 MOTOR SIZE AS INDICATED ON DRAWINGS KP KEY PAD(DIMMING SYSTEM) DESIGNATION AS INDICATED 22. SPECIAL PURPOSE RECEPTACLE �� ■ -� PLUG -IN RECEPTACLE STRIP t TELEPHONE WALL OUTLET 12 DOUBLE TELEPHONE WALL OUTLET Q FLOOR MOUNTED TELEPHONE OUTLET G DATA /PHONE OUTLET Cl TELEVISION WALL OUTLET D 2 DOUBLE TELEVISION WALL OUTLET LDRP 15 BUSDUCT OR WIREWAY ❑J SAFETY SWITCH, NOT FUSED UNLESS OTHERWISE SHOWN, X 360 180 AMP, POLES, FUSE SIZE FIRE DETECTION AND ALARM SYMBOLS 0 l__� LOCATION OF SUBSCRIPT, X NOTE: THE FOLLOWING SUBSCRIPTS ARE USED TO INDICATE VARIOUS TYPES OF FIRE ALARM STATIONS (NO SUBSCRIPT) MANUAL STATION SPEAKER /HORN AND STROBE LIGHT COMBINATION UNIT ® STROBE LIGHT &A SPEAKER ®X /LOCATION OF SUBSCRIPT. SMOKE DETECTOR NOTE: THE FOLLOWING SUBSCRIPTS ARE USED TO INDICATE VARIOUS TYPES OF SMOKE DETECTORS (NO SUBSCRIPT) PHOTOELECTRIC D . FOR DUCTWORK A SINGLE STATION WITH AUXILIARY CONTACT 120VAC, 9 VOLT BATTERY BACK -UP E WITH AUXILIARY CONTACTS FOR ELEVATOR RECALL w� X�LOCATION OF SUBSCRIPT. UTOMATIC HEAT DETECTOR NOTE: THE FOLLOWING SUBSCRIPTS ARE USED TO INDICATE VARIOUS TYPES OF HEAT DETECTORS (NO SUBSCRIPT) FIXED TEMPERATURE, 136 DEC. H FIXED TEMPERATURE, 190 DEC. C COMBINATION, 136 DEG. 0] INPUT /OUTPUT INTERFACE MODULE ® FAN SHUTDOWN RELAY �J COMBINATION MAGNETIC MOTOR STARTER W.P. X WITH FUSIBLE DISCONNECT SWITCH MOUNTED TYPE 8 INDICATED.QTY & LENGTH AS SHOWN. AMP, POLES, FUSE SIZE STARTER SIZE DOOR SWITCH $ MISCELLANEOUS SYMBOLS JUNCTION BOX NOTE: THE FOLLOWING SUBSCRIPTS ARE USED TO NOTES: REFERENCE SYMBOLS: DENOTES "SEE NOTE #2" INDICATE VARIOUS TYPES OF SWITCHES (NO SUBSCRIPT) LIGHTING 2 Q REFERENCE SYMBOLS: DENOTES LIGHT FIXTURE WMINAIRE TYPE THREE WAY 0 CEILING LIGHT OUTLET W /FIXTURE TE 1-0 BRACKET LIGHT OUTLET W /FIXTURE HORSEPOWER MOTOR HQ CEILING LIGHT OUTLET W /FIXTURE -- -- - y/ LIGHTED HANDLE CONNECTED TO ALTERNATE SOURCE. KEY OPERATED 1-7 BRACKET LIGHT OUTLET W /FIXTURE W.P. CONNECTED TO ALTERNATE SOURCE. V 0 0 rn TRACK LIGHTING OUTLET W /FIXTURE �J� MOUNTED TYPE 8 INDICATED.QTY & LENGTH AS SHOWN. ® DOOR SWITCH $ SWITCH JUNCTION BOX NOTE: THE FOLLOWING SUBSCRIPTS ARE USED TO NOT TO SCALE INDICATE VARIOUS TYPES OF SWITCHES (NO SUBSCRIPT) SINGLE POLE 2 DOUBLE POLE 3 THREE WAY 4 FOUR WAY TE THERMAL ELEMENT FOR FRACTIONAL OR CORD SHALL BE INSTALLED IN ALL EMPTY CONDUITS. HORSEPOWER MOTOR P PILOT LIGHT L LIGHTED HANDLE K KEY OPERATED M MOTION SENSOR 0 CEILING MOUNTED MOTION SENSOR CIRCUIT DESIGNATION BRANCH CIRCUIT HOMERUN (ARROWHEADS INDICATE NUMBER OF HOMERUN CIRCUITS) CONDUIT RISER UP CONDUIT RISER DOWN STUB INTO ACCESSIBLE CORRIDOR CEILING SPACE, UNLESS OTHERWISE NOTED INDICATES CIRCUIT CONTINUATION, CONDUIT SEAL FITTING FOR HAZARDOUS AREAS GROUNDING CONDUCTOR ABBREVIATIONS A.F.F. ABOVE FINISHED FLOOR W.P. WEATHERPROOF EQUIPMENT MTD MOUNTED TYP. TYPICAL GND GROUND J.B. JUNCTION BOX N.T.S. NOT TO SCALE A.H.U. AIR HANDLING UNIT EMT ELECTRIC METALLIC TUBING GR /G.F.C.I. GROUND FAULT CIRCUIT INTERRUPTER GENERAL LEGEND NOTES 1. THESE ARE STANDARD SYMBOLS AND MAY NOT ALL APPEAR ON THE PROJECT DRAWINGS, HOWEVER, WHEREVER THE SYMBOL ON PROJECT DRAWINGS OCCURS, THE ITEMS SHALL BE PROVIDED AND INSTALLED UNLESS OTHERWISE NOTED. 2. REFER TO DRAWINGS SPECIFIC NOTES AND COMMENTS FOR SYMBOLS NOT INCLUDED ON THIS LIST. 3. PROVIDE MEANS FURNISH AND INSTALL. 4. REFER TO MECHANICAL DRAWINGS FOR EQUIPMENT LOCATION AND ELECTRICAL REQUIREMENTS AND CHARACTERISTICS AND PROVIDE FOR COMPLETE ELECTRICAL INSTALLATION ACCORDINGLY. 5. ALL SWITCHES SHALL BE GANGED WHERE TWO (2) OR MORE ARE INSTALLED AT THE SAME LOCATION. 6. ALL WIRING DEVICES (SWITCHES, RECEPTACLES, DIMMERS, TELEPHONE, CABLE TELEVISION, ETC.) SHALL BE HUBBELL SPECIFICATION GRADE, SUITABLE FOR THE LOCATION IN WHICH THEY ARE GOING TO BE USED. PROVIDE TAYMAC COVERS FOR OUTDOOR USE. 7. EVERY BRANCH CIRCUIT SHALL INCLUDE GROUND CONDUCTOR IN ADDITION TO THE REQUIRED NEUTRAL AND PHASE CONDUCTORS. N TYPE SQUARED NQOD MAIN RI Ic OOR A►eo ill GENERAL ELECTRICAL NOTES 1. THE CONTRACTOR SHALL FURNISH AND INSTALL ALL MINOR ITEMS WHICH ARE OBVIOUSLY AND REASONABLY NECESSARY TO COMPLETE THE 19. ALL CONDUCTORS SHALL BE COPPER, UNLESS OTHERWISE NOTED, 60OV; #10 AND (TWO 10000 AIC REMARKS PANTRY INSTALLATION. FAULT SMALLER, TYPE THHN /THWN; #8 AND LARGER, TYPE THWN; #12 MINIMUM EXCEPT NEUTRAL PANEL) MAINS CURRENT 3165 LOCATION CKT, NO. REMARKS 2 RECOVERY WIRE - 225 L.O. ELEC. CON DUIT CONTROL WIRING. 2. BIDDERS SHALL VISIT THE SITE AND FAMILIARIZE THEMSELVES WITH ALL CONDI- - _ 1 20 TIONS SURROUNDING THE WORK. 20. ALL WIRING MUST BE IN CONDUIT. UNLESS SPECIFIED OTHERWISE, A PULL WIRE 3 - - - - - - - - - - - - - - - -- - - - - - - - OR CORD SHALL BE INSTALLED IN ALL EMPTY CONDUITS. 3. THE CONTRACTOR IS REFERRED TO THE ARCHITECTURAL PLANS AND 20 20 1 1 SPECIFICATIONS. SUCH PLANS AND SPECIFICATIONS ARE TO BE CONSIDERED 21. USE RIGID GALVANIZED STEEL CONDUIT WHERE EXPOSED OUTDOORS, OR WHERE 20 PART OF THE ELECTRICAL CONTRACT DOCUMENTS. _ -- EXPOSED IN ANY LOCATIONS SUBJECT TO MECHANICAL INJURY. EMT MAY BE 5 - 6 RECOVERY USED ELSEWHERE, NO ALUMINUM CONDUIT WILL BE PERMITTED. PVC MAY BE USED 4. DRAWINGS ARE DIAGRAMMATIC AND INTENDED TO SHOW APPROXIMATE LOCA- 1 WHERE BURIED UNDER GRADE OR EMBEDED IN CONCRETE SLABS OR WALLS, - TIONS AND ARRANGEMENTS ONLY UNLESS OTHERWISE NOTED 20 -- -- SPARE 22. ALL WIRING DEVICES COVER PLATES SHALL BE ENGRAVED WITH POWER BRANCH, 5. ALL MATERIALS SHALL BE NEW, OF TYPES AND MAKES CALLED FOR, OR AP- - PANEL DESIGNATION AND CIRCUIT NUMBER. FOR EXAMPLE CRITICAL 3LA -5. 1 PROVED EQUAL. 180 1 20 -- 23. ALL CONDUITS THROUGH ROOF SHALL PENETRATE ROOF USING PROPER APPROVED 6. CONTRACTOR SHALL SUBMIT REQUEST FOR SUBSTITUTIONS PRIOR TO BIDDING LDRP 15 ROOF FLASHING, -- IN WRITING TO THE ENGINEER. 1 360 180 1 24. FLEXIBLE CONDUIT SHALL BE USED FOR CONNECTIONS TO VIBRATING EQUIPMENT. "SEALTITE" 7. CONTRACTOR SHALL TOUCH UP OR REFINISH THE FACTORY FINISH OF EQUIPMENT 11 WHERE USED OUTDOORS. LDRP 12 -15 NL MARRED DURING SHIPMENT OR INSTALLATION. -T--2 20 1 720 25. ELECTRICAL EQUIPMENT EXPOSED TO WEATHER MUST BE WEATHERPROOF. 8. THE ELECTRICAL INSTALLATION SHALL MEET THE APPROVAL OF THE GOVERNING -- LDRP 1 HEADWALL 13 AUTHORITIES AND THE OWNER'S REPRESENTATIVES BEFORE ACCEPTANCE. 26. FUSES SHALL BE BUSSMAN W, ON" DUAL - ELEMENT, TIME DELAY, OR EQUAL, -- 20 1 OR AS CALLED FOR ON DRAWINGSINGS. 9. THE CONTRACTOR SHALL BE A LICENSED MASTER ELECTRICIAN. 20 -- - LDRP 1 HEADWALL 27. PROVIDE TYPEWRITTEN INDEX CARDS FOR ALL PANELS, 10. THE ENTIRE INSTALLATION SHALL BE PERFORMED IN A FIRST -CLASS WORK- MANLIKE MANNER. 28. PROVIDE ALL ELECTRICAL CONTROLLERS, DISCONNECT SWITCHES AND 1 360 360 WITH PLASTIC EMBOSSED LABELS, 11. THE ELECTRICAL CONTRACTOR SHALL PROVIDE TEMPORARY POWER AND LIGHT- ING AS REQUIRED FOR ALL TRADES. 29. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROPERLY BALANCING ALL 17 18 RECOVERY BRANCH CIRCUITS BETWEEN THE PHASES OF THE SYSTEM REGARDLESS OF CIR- 12. ELECTRICAL WORK SHALL NOT INTERFERE WITH CLEARANCES REQUIRED FOR 1 CUITING INDICATED. 180 GENERAL AND MECHANICAL CONSTRUCTION. SHOULD ELECTRICAL WORK BE IN- STALLED WHICH INTERFERES WITH THE 30, HVAC CONTROLS ARE TO BE FURNISHED BY MECHANICAL OR CONTROLS -- WORK OF THE OTHER CONTRACTORS, SUCH WORK SHALL BE CHANGED AT NO ADDITIONAL COST TO THE OWNER. 19 CONTRACTOR INCLUDING CONTROL WIRING. 13. AT THE COMPLETION OF THE WORK, THIS CONTRACTOR SHALL REMOVE ALL 31, 20 AMP CIRCUITS FROM 100 FT. TO 200 FT. ONE -WAY, USE #10 WIRE: OVER 200 FT., USE #8 WIRE. 1 RUBBISH CAUSED BY HIS WORK AND SHALL THOROUGHLY CLEAN ALL ELECTRICAL 180 1 20 EQUIPMENT, 32. ALL EQUIPMENT AND SYSTEMS SHALL BE DEMONSTRATED TO BE FUNCTIONING 21 22 RECOVERY SATISFACTORILY PRIOR TO FINAL ACCEPTANCE. 14. ALL WORK SHALL BE GUARANTEED FREE FROM DEFECTS FOR A PERIOD OF ONE 180 360 YEAR FROM DATE OF FINAL ACCEPTANCE. 33. MAINTAIN THE FIRE RATING OF ALL PARTITIONS WALLS THROUGH WHICH CONDUIT -- LDRP 3 HEADWALL 23 PASS AND JUNCTION BOXES ARE INSTALLED IF REQUIRED. 15. ALL ITEMS OF ELECTRICAL EQUIPMENT ASSOCIATED WITH THE CONTROL OF 20 1 ELECTRICAL APPARATUS SHALL BE IDENTIFIED. 34. PROVIDE A GREEN COLOR GROUNDING CONDUCTOR SIZED PER NEC IN ALL 20 -- -- FEEDERS AND BRACH CIRCUITS. 16. NOMINAL MOUNTING HEIGHT OF DEVICES IN EXPOSED CONCRETE BLOCK, OR BRICK WALLS SHALL ALL OCCUR WITHIN A STRUCTURAL COURSE. A 35. ALL WORK AND MATERIALS SHALL BE IN FULL ACCORDANCE WITH THE FOLLOWING -- MINIMUM AMOUNT OF BLOCK, OR BRICK WALLS SHALL BE CUT. 1 APPLICABLE CODES: 180 1 20 - NFPA 70 (NEC) 2008 17. ALL ELECTRICAL EQUIPMENT SHALL BE COMMERCIAL SPECIFICATION GRADE 27 - NFPA 72 2002 RECOVERY HEAVY DUTY, AND UL APPROVED UNLESS SPECIFIED OTHERWISE. -- - NFPA 99 2005 1 180 360 - NFPA 101 2006 18. WIRING DEVICES SHALL BE HOSPITAL GRADE. DECORATOR STYLE WHITE COLOR. -- - FBC 2007 WITH 2009 SUPPLEMENTS. 29 USE RED FOR EMERGENCY POWER CIRCUITS. BOXES FOR LINE VOLTAGE RECOVERY - GUIDELINES FOR DESING AND CONSTRUCTION OF HEALTH CARE FACILITIES. -- WIRING ,SHALL BE SQUARE. 1 AIA GUIDELINES 2006. TYPE SQUARED NQOD MAIN RI Ic OOR A►eo ill 1Q NEW CIRCUIT ON EXISTING SPARE BREAKER. It TYPE SQUARE D NQOD MAIN RIIC1nn AMID ('II btNVIUL ,WH, 4w YAIVtL 1C:L7L-3 "" NEUTRAL 100 AMP CU VOLTAGE 120/208V (TWO SECTION PANEL) MAINS L.O. MOUNTING FLUSH KAIC LOCATION MECH. ROOM 2nd. FLR, VOLTAGE MOUNTING VOLT AMP 360 OLE 1 120/208V FLUSH TRIP 20 CON DUIT -- WIRE - (TWO 10000 AIC REMARKS PANTRY SECTION - CKT. NO. 1 FAULT CKT. N0, NEUTRAL PANEL) MAINS CURRENT 3165 LOCATION CKT, NO. REMARKS 2 RECOVERY WIRE - 225 L.O. ELEC. CON DUIT AMP ROOM TRIP CU 3rd. POLE FLR. VOLT AMP - _ 1 20 -- -- SPARE 3 - - - - - - - - - - - - - - - -- - - - - - - - 4 RECOVERY -- -- -- 20 20 1 1 360 180 - 1 20 -- _ -- SPARE 5 - 6 RECOVERY - -- 20 1 180 - 1 20 -- -- SPARE 7 8 _ LDRP 14 - - 20 1 360 180 1 20 -- -- NURSE STATION 9 10 LDRP 15 -- -- 20 1 360 180 1 20 -- -- NURSE STATION 11 12 LDRP 12 -15 NL -- -T--2 20 1 720 180 1 20 -- -- LDRP 1 HEADWALL 13 14 RECOVERY -- -- 20 1 180 180 1 20 -- - LDRP 1 HEADWALL 15 16 RECOVERY - -- 20 1 360 360 1 20 -- -- LDRP 1 HEADWALL 17 18 RECOVERY -- -- 20 1 1$0 180 1 20 - -- LDRP 3 HEADWALL 19 20 RECOVERY -_ __ 20 1 180 180 1 20 - -- LDRP 3 HEADWALL 21 22 RECOVERY - -- 20 1 180 360 1 20 -- -- LDRP 3 HEADWALL 23 24 CO REVERY -- -- 20 1 360 180 1 20 -- -- LDRP 2 HEADWALL_ 25 26 RECOVERY -- -- 20 1 360 180 1 20 - -- LDRP 2 HEADWALL 27 28 RECOVERY -- -- 20 1 180 360 1 20 -- -- LDRP 2 HEADWALL 29 30 RECOVERY -- -- 20 1 180 180 1 20 -- -- LDRP 4 HEADWALL 31 32 RECOVERY -- -- 20 1 180 1 180 1 20 -- -- LDRP 4 HEADWALL 33 34 RECOVERY CCTC MONITORS -- 20 1_ 360 360 1 20 -- -- LDRP 4 HEADWALL 35 - 36 RECOVERY - -- 20 1 180 1000 180 1 20 -- -- LDRP _5 HEADWALL 37 38 RECOVERY -- -- 20 1 180 1 180 1 20 -- -- LDRP 5 HEADWALL 39 40 RECOVERY -- -- 20 1 180 20 360 1 20 -- -- LDRP 5 HEADWALL 41 42 RECOVERY -- -- 20 1 360 -- 360 1 20 -- -- COMM. CLOSET 43 44 LDRP 12 -- -- 30 1 360 -- _COPIER 360 1 20 -- -- COMM. CLOSET 45 46 LDRP -13 -- -- 30 1 360 360 1 20 -- -- TREATMENT 47 48 SPARE 360 1 20 1 -- 360 1 20 -- -- I K R 49 50 LDRP- 6 HEADWALL -- -- 20 1 180 400 1 20 -- -- C_TC NCTC 51 52 LDRP- 6 HEADWALL - -- 20 1 180 400 1 20 -- -- NCTC 53 54 LDRP- 6 HEADWALL - -- 20 1 360 180 1 20 -- -- LDRP 7 HEADWALL 55 56 LDRP- 8 HEADWALL -- -- 20 1 180 180 1 20 -- -- LDRP 7 HEADWALL 57 58 LDRP- 8 HEADWALL 1 -- 20 1 180 360 1 20 -- - LDRP 7 HEADWALL 59 60 62 LDRP- 8 HEADWALL LDRP- 9 HEADWALL -- -- -- -- 20 20 1 1 360 180 180 1 20 -- -- LDRP 12 HEADWALL 61 180 1 20 - - -- LDRP 12 HEADWALL 63 64 LDRP- 9 HEADWALL -- -- 20 1 180 360 1 20 - -- LDRP 12 HEADWALL 65 66 68 LDRP- 9 HEADWALL LDRP- 10 HEADWALL -- _ -- 20 1 360 180 1 20 -- -- LDRP 13 HEADWALL 67 180 1 20 -- -- LDRP 13 HEADWALL 69 - - - -- -- - - - -- - - -- - - - - 1 - - -- 30 1 180 70 LDRP- 10 HEADWALL 68 -- 30 1 180 360 1 20 -- -- LDRP 13 HEADWALL 71 72 LDRP- 10 HEADWALL -- -- 20 1 360 180 1 20 1 -- LDRP 14 HEADWALL 73 74 LDRP- 11 HEADWALL - -- 20 1 180 180_ 1 20 -- -- LDRP 14 HEADWALL 75 76 LDRP- 11 HEADWALL -- -- 20 1 180 360 1 20 - -- LDRP 14 HEADWALL 77 78 LDRP- 11 HEADWALL -- -- 20 1 360 180 1 20 -- -- LDRP 15 HEADWALL 79 80 LDRP 6 -11 NL - -- 20 1 720 180 1 20 -- -- LDRP 15 HEADWALL 81 82 LDRP 11 - -_ -- 20 1 360 360 360 1 1 20 20 -- -- -- -- LDRP 15 HEADWALL NURSE STATION 83 85 84 86 LDRP 10 LDRP 9 - -- -- -- 20 20 1 1 360 360 360 1 20 -- -- MED PREP. 87 88 LDRP 8 -- -- 20 1 360 > 360 1 20 -- -- PNEUMATIC TUBE SYST. 89 90 LDRP 7 -- -- 20 1 _ 360 300 1 20 - -- TIME CLOCK LDRP. 91 - 92 LDRP 6 -- -- 20 1 360 1 20 -- -- SPARE 93 94 LDRP 5 -- -- 20 1 360 360 1 20 -- -- _ ELEC. RM. 95 96 LDRP 4 -- -- 20 1 360 360 1 20 -- -- NS TRIAGE 97 - 98 LDRP 3 -- -- 30 1 360 - 1 20 -- -- SPARE 99 100 LDRP 2 -- -- 30 1 360 - 1 OO -- -- SPARE 101 102 LDRP 1 -- -- 20 1 360 360 1 20 -- - PYAXIS OMNICELL 103 104 LDRP 1 -5 -- -- 20 1 720 360 1 20 -- -- LDR 1 -2 FOOTWALL 105 106 LDRP 9 -10 FOOTWALL -- -- 20 1 360 360 1 20 - -- LDR 3 -4 FOOTWALL 107 108 LDRP 11 -12 FOOTWALL -- - 20 1 360 360 1 20 -- -- LDR 5 -6 FOOTWALL 109 110 LDRP 13 -14 FOOTWALL -- -- 20 1 360 360 1 20 -- --- LDR 7 -8 FOOTWALL 111 - 112 OMNICELL N CORR -- -- 20 1 400 - 1 20 -- -- SPACE 113 114 OMNICELL N CORR - -- -- 20 20 1 1 400 400 - 1 20 -- -- SPACE 115 - - (IL= 116 OMNICELL N CORR -- 1 20 -- - SPACE 117 - 118 OMNICELL N CORR -- -- 20 1 400 _ - 1 20 -- SPACE 119 120 SPACE -- -- 20 1 - 9360 23420 1 TOTAL 20 TOTAL - -- PANEL. CONNECTED "CL3NA" LOAD 41760 121 122 BLOOD BANK REC. -- -- 20 1 180 123 124 SPACE -- -- 20 1 - 125 --- VA 126 SPACE 116 AMP) -- _ -- 20 TOTAL 1 18340 1Q NEW CIRCUIT ON EXISTING SPARE BREAKER. It TYPE SQUARE D NQOD MAIN RIIC1nn AMID ('II btNVIUL ,WH, 4w YAIVtL 1C:L7L-3 "" NEUTRAL 100 AMP CU VOLTAGE 120/208V (TWO SECTION PANEL) MAINS L.O. MOUNTING FLUSH KAIC LOCATION MECH. ROOM 2nd. FLR, VOLT AMP OLE TRIP CON DUIT WIRE REMARKS CKT. NO tY CKT. N0, REMARKS WIRE CON DUIT TRIP POLE VOLT AMP 500 1 20 -- -- PREP. 21 -22 BED 1 - - - - - -4 - - - 2 VISICUE -- -- 20 1 360 360 1 20 -- -- VISICUE 3 PACS -- -- 20 1 720 360 1 20 -- -- VISICUE _ 5 6 PACS - - 20 1 720 360 1 20 -- -- VISICUE 7_ 8 DMS WORKROOM MAN - -- 20 1 720 600 1 20 -- -- NCT 9 10 MANAGER ASS. MGR. -- -- 20 1 540 720 1 20 -- -- SCHED. /FILES FILM 11 - 12 NURSE STATION -- -- 20 1 360 1000 1 20 -- -- NURSE STATION 13 14 NURSE STATION -- -- 20 1 720 1000 1 20 -- -- NURSE STATION 15 16 NURSE STATION -- -- 20 1 720 500 1 20 -- -- MED PREP. PYXIS 17 18 NURSE STATION -- -- 20 1 720 500 1 20 -- -- MED PREP. PYXIS 19 20 NURSE STATION - - -_ 20 1 720 500 1 20 -- -- MED PREP. PYXIS 21 22 NURSE STATION -- -- 20 1 720 400 1 20 -- - MED PREP. UC REF. 23 24 26 NOURISH - ICEMAKER -- -- 20 1 800 600 1 20 -- -- OMNICELL 25 600 1 20 -- -- OMNICELL 27 - - J�_4o - - - - - NOURISH REF. - -- 20 1 800 2$ STOR /REPORT RM. -- -- 20 1 720 600 1 20 -- -- OMNICELL 29 30 MGR. /ASS. MGR. -- -- 20 1 500 1 20 -- -- DEFRIBRILLATOR 31 32 CCTC MONITORS -- -- 20 1 1000 1 20 -- - XRAY RECEPTACLE 33 34 CCTC MONITORS - -- 20 1 5 1000 1 20 -- -- XRAY RECEPTACLE 35 36 PREP. #11 -12 BED -- -- 20 1 1000 1 20 -- -- XRAY RECEPTACLE 37 38 PREP. #13 -14 BED -- -- 20 1 720 1 20 -- -- PNEUMATIC TUBE 39 PREP. #16 -20 BED - -- 20 1 500 - 1 20 -- -- SPARE 41 42 ROOF - -- 20 1 180 1000 1 20 -- -- _COPIER PRINTER 43 44 VISICUE -- - 30 1 360 360 1 20 -- -- VISICUE 45 46 ISICUE - -- 30 1 360 360 1 20 - -- VISICUE 47 48 50 ISICUE -- -- 20 1 360 360 1 20 -- -- VISICUE 49 360 - 1 20 -- -- VISICUE 51 - - - - - NURSE STATION COPIE -- -- 20 1 1000 52 SHUTTER OPERATORS -- -- 20 1 500 400 1 20 - -- CAR READER 53 54 SHUTTER OPERATORS -- -- 20 1 500 - 1 20 -- -- SPARE 55 56 SPARE_ _ __ 20 1 - - 1 20 -- -- SPARE 57 58 SPARE -- -- 20 1 - 360 1 20 -- -- NURSE STATION 59 60 SPARE -- -- 20 1 _ - 1 20 - -- SPARE 61 62 SPARE - -- 20 1 - - 1 20 -- -- SPARE 6-3 64 SPARE - -- 20 1 _ - 1 20 -- -- SPARE 65 66 SPARE - -- 20 1 - - 1 20 -- -- SPARE 67 - 68 SPARE _ -- -- 30 1 - - 1 20 -- ' SPARE 69 70 SPARE -- -- 30 1 - - 1 20 -- -- SPARE _ 71 72 SPARE - -- 20 1 - - 1 20 -- -- SPARE 73 - 74 76 SPARE - -- 20 1 - - 1 20 -- -- SPARE - 1 20 -- -- SPARE 75 77 - -- SPARE __ _- 20 1 - 78 SPARE -- -- 20 1 - - 1 20 - -- SPARE 79 80 SPARE -- 20 1 - - 1 20 -- -- SPARE _ 81 82 SPARE -- -- 20 1 _ - 16020 1 TOTAL 20 TOTAL -- -- SPARE CONNECTED LOAD 31840 83 VA - (IL - 84 SPARE =88 AMP) -- -- 20 TOTAL 1 - 15820 1Q CONNECT TO EXISTING CIRCUIT. I AIA, Inc. #AA0003360 Architecture Planning Construction Administration BC Architects AIA, Inc. 4942 LeJeune Road Suite 200 Coral Gables, FL 33146 Tel. 305.663.8182 Fax 305.663.8882 Firm License Number: AA0003360 1 BC ARCHITECTS 2011 QQ ALL RIGHTS RESERVED SIGNED BY: LAWRENCE S. CO FLORIDA ARCHITECT y �r� i t oaf ,.... . Labor & Delivery Pneumatic Tube Station SOUTH MIAMI HOSPITAL 2nd AND 3rd FLOORS 6200 SW 73 STREET SOUTH MIAMI, FLORIDA 33143 OWNER: BAPTIST HEALTH SOUTH FLORIDA, INC. 8900 North Kendall Drive, Miami, Florida 33176 I NO. I DATE I REVISIONS ISSUE RECORD: 06/28/11 PERMIT ISSUE B.C. Comm. No. 1101.02 Scale: 1/8" = 1' -0" Drawn: VJ Checked: LC CADD File: 1101.02_A2.01 SHEET TITLE GENERAL ELECTRICAL NOTES, SYMBOL LEGEN AND SCHEDULES. SHEET No. E0.01 r� 0 tY � i n iI I AIA, Inc. #AA0003360 Architecture Planning Construction Administration BC Architects AIA, Inc. 4942 LeJeune Road Suite 200 Coral Gables, FL 33146 Tel. 305.663.8182 Fax 305.663.8882 Firm License Number: AA0003360 1 BC ARCHITECTS 2011 QQ ALL RIGHTS RESERVED SIGNED BY: LAWRENCE S. CO FLORIDA ARCHITECT y �r� i t oaf ,.... . Labor & Delivery Pneumatic Tube Station SOUTH MIAMI HOSPITAL 2nd AND 3rd FLOORS 6200 SW 73 STREET SOUTH MIAMI, FLORIDA 33143 OWNER: BAPTIST HEALTH SOUTH FLORIDA, INC. 8900 North Kendall Drive, Miami, Florida 33176 I NO. I DATE I REVISIONS ISSUE RECORD: 06/28/11 PERMIT ISSUE B.C. Comm. No. 1101.02 Scale: 1/8" = 1' -0" Drawn: VJ Checked: LC CADD File: 1101.02_A2.01 SHEET TITLE GENERAL ELECTRICAL NOTES, SYMBOL LEGEN AND SCHEDULES. SHEET No. E0.01