Loading...
11-520-006BUTYL, SELF - ADHERED FLASHING MEMBRANE — 22 GA ST. 316 STL. COPING - PROVIDE JOINT END CLEATS @ 8'4" O.C. INSULATION THICKNESS VARY ALONG PARAPET WALL SILICONE SEALANT #10 ST. STL. SCREWS W/ METAL BACK NEOPRENE WASHERS @ 12" O.C. TYP. SEAL OVER ALL SCREW HEADS, TYP. 22 GA ST. STL. COUNTERFLASHING SIBS MB ENERGY CAP MEMBRANE SBS MB MEMBRANE PLY SHEET 2" WIDE ST. STL. CLIP @24" O.C. - SELF ADHERING BASE SHEET 1/4" ROOF BOARD 7 1/4" I FT 22 GA ST. STL. CLIP CONT. 2 X PRESSURE TREATED WOOD NAILER SEALANT EXISTING STUCCO FINISH TO REMAIN. REHABILITATE PER CONTRACT DOCUMENTS MASONRY DIVIDER WALL DET. SCALE: 1 -1/2" = V -0" CUT AND PATCH EIFS SYSTEM TO ALLOW FOR I SEALANT I EXP. JOINT INSTALLATION #10 ST. STL SCREWS W/ MATCH EXIST. FINISH AND METAL BACK NEOPRENE COORDINATE WORK WITH SEALANT ARCHITECT d OVER ALL SCREW HEADS FILLET SEAL WITH BOND i TYPICAL BREAKER CORNER TAPE 22 GA ST. STL. METALASTIC EXPANSION COUNTER - COVER CONTINUOUS FLASHING - 2 X P.T. CURB ASSEMBLY VERIFY EXIST. CONDITIONS M.B. ENERGY CAP BASE FLASHING 22 GA - 316 ST. STL. COPING - PROVIDE JOINT END CLEATS @ 8' -0" O.C. #10 STAINLESS STEEL SCREWS W/ METAL BACK NEOPRENE WASHERS @ 8" O.C. TYP. (SEAL) EXIST. STUCCO. CUT AND PATCH DAMAGED MATERIAL 20 GA ST. STL. CLIP CONTINUOUS 2 X PRESSURE TREATED 1/4" / FT WOOD NAILER TOP OF PARAPET EL: +39 -6" SEALANT SEALANT 22 GA. ST. STEEL. �— SCUPPER - REFER TO SCUPPER SCHEDULE SET SCUPPER INVERT 2" ABOVE ROOF DRAIN ROOF SLAB EL: +35 -6" TYP. EXT. WALL SCUPPER DET. SCALE: 1 -1/2" = V -0" ENERGY CAP FLASHING MEMBRANE SBS MB ENERGY CAP SBS MB MEMBRANE PLY SHEET SELF ADHERING BASE SHEET 1/4" ROOF BOARD O RATE ATION BOARD INSULATION j //l L_ DUAL SEALANT APPLICATION ROOF SECTION AT EXPANSION JOINT SCALE: 1 -1/2" = V -0" 22 GA. 316 ST. STL. FLASHING. FASTEN W/ ST. STL. STORM CLEATS @ 30" O.C. - 1 @ EA JOINT METALASTIC EXPANSION COVER CONTINUOUS BITUMINOUS BASE FLASHING 1/4" PRIMED, FIBER - REINFORCED GYP. ROOF BOARD 3" POLYISOCYANURATE INSULATION EXISTING CONCRETE DECK TO REMAIN 2 X 10 P.T. CURB -CANT ASSEMBLY CONT. 10 MIL. VAPOR BARRIER TO ENCAPSULATE COMPRESSIBLE INSULATION DUAL SEALANT APPLICATION: DOW 790 SILICONE SEALANT OVER BACKER ROD, OVER MICRO -CELL FOAM SEALANT SBS MODIFIED BITUMEN ENERGY CAP - SBS MODIFIED BITUMEN MEMBRANE PLY SHEET SELF ADHERING BASE SHEET - -- ROOF SECTION AT ELEVATOR CHASE SCALE: 1 -1/2" = V -0" EXIST- CONCRETE DECK EXISTING ALUMINUM LOUVERS TO REMAIN ELEVATOR CHASE CONCRETE ROOF DECK ENERGY CAP FLASHING MEMBRANE 1/4" X 5" MIN. ST. STL. SELF TAPPING'TAPCON' FASTENERS @ 12" O.C. W/ 1" ST. STL.FLAT WASHER -TYP. 2X6 PRESSURE TREATED WOOD BLOCKING 22 GA - 316 ST. STL. EDGE PROVIDE JOINT END CLEATS @ 8' -0" O.C. 20 GA ST. STL. CLIP CONTINUOUS 22 GA - 316 ST- STL, CLOSURE PIECE AT UNDERSIDE OF WOOD BLOCKING SILICONE SEALANT EXISTING MASONRY WALL - PRESSURE CLEAN AND REPAINT SBS MB ENERGY CAP SBS MB MEMBRANE PLY SHEET SELF ADHERING BASE SHEET 1/4" ROOF BOARD POLYISOCYANURATE TAPERED INSULATION 611/2" II Y II � II I II I II I II I II I II I ii jl I II I II I II I II I II I II I II I I 22 GA - 316 ST. STL, COPING 20 GA ST. STL. CLIP - PROVIDE JOINT END CONTINUOUS CLEATS @ 8' -0" O.C. 2 X PRESSURE TREATED #10 STAINLESS STEEL 1/4" / FT WOOD NAILER SCREWS W/ METAL BACK F ---- NEOPRENE WASHERS @ 8" O.C. TYP. (SEAL) SEALANT SBS M.B. ENERGY CAP ROOF MEMBRANE SEALANT SBS MODIFIED BITUMEN 22 GA. ST. STL. MEMBRANE PLY SHEET SCUPPER SCHEDULED SCUPPER - REFER T SELF ADHERING BASE SHEET L TAPERED INSULATION 22 GA. 8" D X 12" W X 14" D ST. STL. CONDUCTOR HEAD 22 GA. ST. STL- 4" DIA- - - -- DOWNSPOUT - 14 GA. ST. STL. DOWNSPOUT HANGER 8 STAIR SCUPPER DET. SCALE: 1 -1/2" = V -0" BUTYL, SELF - ADHERED FLASHING MEMBRANE 22 GA ST. 316 STL. COPII PROVIDE JOINT END CLI @ 8' -0" O.C. EXIST. STUCCO FINISH 1 REMAIN. SOUND WALLA TEST FOR DELAMINATIC WATERPROOF COATING OVER EXPOSED CURB SURFACES EXISTING PLANTER CURB TO REMAIN SEALANT #10 ST. STL. SCREWS W/ METAL BACK NEOPRENE WASHERS @ 12" O.C. SEAL OVER ALL SCREW HEADS - TYPICAL 22 GA ST. STEEL COUNTER - FLASHING N 20 GA ST. STL CLIP CONT- 2 X PRESSURE TREATED WOOD NAILER' SEALANT WATERPROOF COATING OVER EXPOSED CURB SURFACES EXISTING PLANTER CURB TO REMAIN DECD D TO C SCUPPER DET. SCALE: 1 -1/2" = V -0" 22 GA 316 ST. STL. COPING - PROVIDE JOINT END CLEATS @ 8' -0" O.C. AND SOLDER ALL JOINTS 3/4" EXTERIOR PLYWOOD. SEALANT DUAL SEALANT APPLICATION: DOW 795 SILICONE — SEALANT OVER BACKER ROD, OVER MICRO -CELL FOAM SEALANT SEALANT 410 ST. STL. SCREWS W /NEOPRENE WASHERS @ 8" O.C. TYP. --� 22 GA ST. STL. COUNTER- FLASHING SEALANT AROUND SCUPPERIFRAME 5 "x13" ST. STL. 22 GA SCUPPERi EXTENSION -FULLY SOLDERED - I - I _ SET SCUPPER INVERT 2"1 ABOVE LOW POINT OF ROOF OVERFLOW SCUPPER EXTENSION AT PLANTER SCALE: 1 -1/2" = V -0" THOROSEAL PLASTE'� F1t113H COAT - PAINTED FIBER REINFORCED SCRATCH ANI) BROWN COAT STUCCO EXISTING CONCRETE COLUMN STUB TO REMAIN - PRESSURE CLEAN AND REPAINT SILICONE SEALANT #10 ST. STL. SCREWS W/ METAL BACK NEOPRENE WASHERS @ 8" O.C. TYP, SEAL OVER ALL SCREW HEADS, TYP. 22 GA ST. STL. COUNTERFLASHING 2" WIDE ST. STL. CLIP @24" O.C. SBS MB ENERGY CAP MEMBRANE CONC. COLUMN TOPPING —TYP. SCALE: 1 -1/2" = V -0" BUTYL, SELF - ADHERED i I I SEALANT I SEALANT #10 ST. STL SCREWS W/ i METAL BACK NEOPRENE 20 GA ST. STL. CLIP CONT. WASHERS @ 12" O.C. SEAL d OVER ALL SCREW HEADS 22 GA ST. STL. i TYPICAL COUNTERFLASHING i I I "' I 4" i I I 22 GA. ST. STL. NAILER I SCUPPER - REFER TO ,I SCUPPER SCHEDULE LIQUID FLASHING OVER FLASHING FABRIC AT SEALANT SCUPPER PLANTER TYP. SEAL OVER ALL PENETRATIONS, TYP. DECD D TO C SCUPPER DET. SCALE: 1 -1/2" = V -0" 22 GA 316 ST. STL. COPING - PROVIDE JOINT END CLEATS @ 8' -0" O.C. AND SOLDER ALL JOINTS 3/4" EXTERIOR PLYWOOD. SEALANT DUAL SEALANT APPLICATION: DOW 795 SILICONE — SEALANT OVER BACKER ROD, OVER MICRO -CELL FOAM SEALANT SEALANT 410 ST. STL. SCREWS W /NEOPRENE WASHERS @ 8" O.C. TYP. --� 22 GA ST. STL. COUNTER- FLASHING SEALANT AROUND SCUPPERIFRAME 5 "x13" ST. STL. 22 GA SCUPPERi EXTENSION -FULLY SOLDERED - I - I _ SET SCUPPER INVERT 2"1 ABOVE LOW POINT OF ROOF OVERFLOW SCUPPER EXTENSION AT PLANTER SCALE: 1 -1/2" = V -0" THOROSEAL PLASTE'� F1t113H COAT - PAINTED FIBER REINFORCED SCRATCH ANI) BROWN COAT STUCCO EXISTING CONCRETE COLUMN STUB TO REMAIN - PRESSURE CLEAN AND REPAINT SILICONE SEALANT #10 ST. STL. SCREWS W/ METAL BACK NEOPRENE WASHERS @ 8" O.C. TYP, SEAL OVER ALL SCREW HEADS, TYP. 22 GA ST. STL. COUNTERFLASHING 2" WIDE ST. STL. CLIP @24" O.C. SBS MB ENERGY CAP MEMBRANE CONC. COLUMN TOPPING —TYP. SCALE: 1 -1/2" = V -0" BUTYL, SELF - ADHERED FLASHING MEMBRANE BUTYL, SELF- ADHERED FLASHING MEMBRANE VARY ALONG PARAPET WALL 22 GA ST. 316 STL. COPING - 20 GA ST. STL. CLIP CONT. PROVIDE JOINT END CLEATS @ 22 GA ST. STL. 8' -0" O.C. SILICONE SEALANT 1/4" I FT CLIP CONT- ---- - - - - -- 2 X PRESSURE TREATED WOOD r-- ----- -- - - --- 2 X PRESSURE NAILER - TREATED WOOD NAILER SEALANT WASHERS @ 12" O -C. SEALANT BLDG. EXP. JOINT AT COLUMN SCALE: 1 -1/2" = V -0" TYP. PARAPET WALL DET. SCALE: 1 -1/2" = V -0" SBS MODIFIED BITUMEN ENERGY CAP FLASHING ENERGY CAP (TYPICAL ROOF EDGE NOTE MEMBRANE SBS MODIFIED BITUMEN MEMBRANE PLY SHEET ENERGY CAP FLASHING 1/4" X 5" MIN. ST. STL. SELF SELF ADHERING TAPPING'TAPCON' BASE SHEET MEMBRANE FASTENERS @ 12" U.C. W/ V 1/4" X 5" MIN. ST. STL. SELF ST. STL.FLAT WASHER TAPPING'TAPCON' 2X6 PRESSURE TREATED FASTENERS @ 12" O.C. W/ 1" ST. STL.FLAT WASHER WOOD BLOCKING 22 GA - 316 ST. STL. EDGE 2X6 PRESSURE TREATED PROVIDE JOINT END WOOD BLOCKING CLEATS @ 8' -0" O.C. ___-__ - -_ 22 GA - 316 ST. STL. EDGE 2 - 2 X 6 P.T. EDGE NAILERS I - - ----- ----- -- - -- -- - -� PROVIDE JOINT END ' - -- - -- j CLEATS @ 8' -0" O.C. -- — 4 X 4 22 GA ST. STEEL GUTTER 20 GA ST. STL. CLIP Cn Cn CONTINUOUS CONCRETE SLAB EXTENSION 22 GA - 316 ST- STL - 4' g 1/ CLOSURE PIECE AT 3 1/2" X 4 1/2" 20 GA ST. STEEL DOWNSPOUT 6 1/2" UNDERSIDE OF WOOD BLOCKING SILICONE SEALANT EXIST. CONCRETE DECK I I EXISTING GALVANIZED STEEL HOODS - REMOVE TEMPORARILY DURING ROOFING PROCEDURES, CONCRETE SLAB EXTENSIOI` PRESSURE CLEAN, AND REINSTALL WITH NEW EXISTING ALUMINUM LOUVERS TO REMAIN STAINLESS STEEL FASTENERS TO MATCH EXISTING. I - EXISTING MASONRY WALL I � TO BE REPAINTED I ELEVATOR CHASE C yy°!!Q 1 r'y or 9� INS'T'ALL NEW DOME, CLAMP COLLAR, GASKETS, SBS MODIFIED BITUMEN HARDWARE, TO COMPLE E N ROOFF DRAIN INSTALLATION REQUIRED, TO SBS MODIFIED BITUMEN i ?_ v#2C Tiop, MEMBRANE PLY SHEET SELF ADHERING BASE SHEET I .L S.aF;an.r 4 EXISTING 4" ROOF DRAIN TO REMAIN' EXISTING CONCRETE ROOF DECK TO REMAIN U z w _._ Io U) 0 W Y qv Z' Q �l za- J U) Z W � f (n W r � co co U) U) Q W Y m � CD dlobh Lo 2 Q � LL Z U) cfl Q M Q O Q n M C) ° -X M W Q CO O W 11 <O °° JZ om JU)<( m w WWU) z0 ED 0 :D 00Q Lo a � L O U cn L Ch u c6 u- cz)E V Z CD Q O rn O co _ co m n,/ C � LL uj J � i _0 U O o Lm a) CL W m o 4:� -- :3 0 12 Q LU U) w U) Ch 1. ° a)uj M H LL +J a O O w z m o W Z l i Manuel Reyes - Otalora, R.A. AR -7319 MARK DATE DESCRIPTION PS 5.5.2011 PERMIT SET W J Q O U) O I- O Z W Q U) 0 PROJ. NO: BHSF 2009 -57 Z CAD FILE: DESIGN BY: Q 2 DRAWN BY: 0 O LL CHECKED BY: m M x d' N SHEETTITLE O F- W Z_ a A 501 1- H 2i SHEET OF uJ 0_ EXISTING STUCCO INSULATION THICKNESS FINISH TO REMAIN. VARY ALONG PARAPET WALL FEATHER OUT AROUND SCUPPER SILICONE SEALANT TO RECEIVE NEW STUCCO #10 ST. STL. SCREWS W/ METAL BACK NEOPRENE WASHERS @ 12" O -C. TYP. SEAL OVER ALL SCREW HEADS, TYP. 22 GA ST- STL_ COUNTERFLASHING SBS MB ENERGY CAP MEMBRANE GROUT -FILL EXIST. SCUPPER OPENING SBS MB MEMBRANE PLY - EXISTING STUCCO FINISH SHEET TO REMAIN. FEATHER OU 2" WIDE ST. STL. CLIP @24" O.C. AROUND PREVIOUS SCUPPER OPENING TO SELF ADHERING BASE SHEET \ RECEIVE NEW STUCCO ' II BOARD \1 J TYP. PARAPET WALL DET. SCALE: 1 -1/2" = V -0" SBS MODIFIED BITUMEN ENERGY CAP FLASHING ENERGY CAP (TYPICAL ROOF EDGE NOTE MEMBRANE SBS MODIFIED BITUMEN MEMBRANE PLY SHEET ENERGY CAP FLASHING 1/4" X 5" MIN. ST. STL. SELF SELF ADHERING TAPPING'TAPCON' BASE SHEET MEMBRANE FASTENERS @ 12" U.C. W/ V 1/4" X 5" MIN. ST. STL. SELF ST. STL.FLAT WASHER TAPPING'TAPCON' 2X6 PRESSURE TREATED FASTENERS @ 12" O.C. W/ 1" ST. STL.FLAT WASHER WOOD BLOCKING 22 GA - 316 ST. STL. EDGE 2X6 PRESSURE TREATED PROVIDE JOINT END WOOD BLOCKING CLEATS @ 8' -0" O.C. ___-__ - -_ 22 GA - 316 ST. STL. EDGE 2 - 2 X 6 P.T. EDGE NAILERS I - - ----- ----- -- - -- -- - -� PROVIDE JOINT END ' - -- - -- j CLEATS @ 8' -0" O.C. -- — 4 X 4 22 GA ST. STEEL GUTTER 20 GA ST. STL. CLIP Cn Cn CONTINUOUS CONCRETE SLAB EXTENSION 22 GA - 316 ST- STL - 4' g 1/ CLOSURE PIECE AT 3 1/2" X 4 1/2" 20 GA ST. STEEL DOWNSPOUT 6 1/2" UNDERSIDE OF WOOD BLOCKING SILICONE SEALANT EXIST. CONCRETE DECK I I EXISTING GALVANIZED STEEL HOODS - REMOVE TEMPORARILY DURING ROOFING PROCEDURES, CONCRETE SLAB EXTENSIOI` PRESSURE CLEAN, AND REINSTALL WITH NEW EXISTING ALUMINUM LOUVERS TO REMAIN STAINLESS STEEL FASTENERS TO MATCH EXISTING. I - EXISTING MASONRY WALL I � TO BE REPAINTED I ELEVATOR CHASE C yy°!!Q 1 r'y or 9� INS'T'ALL NEW DOME, CLAMP COLLAR, GASKETS, SBS MODIFIED BITUMEN HARDWARE, TO COMPLE E N ROOFF DRAIN INSTALLATION REQUIRED, TO SBS MODIFIED BITUMEN i ?_ v#2C Tiop, MEMBRANE PLY SHEET SELF ADHERING BASE SHEET I .L S.aF;an.r 4 EXISTING 4" ROOF DRAIN TO REMAIN' EXISTING CONCRETE ROOF DECK TO REMAIN U z w _._ Io U) 0 W Y qv Z' Q �l za- J U) Z W � f (n W r � co co U) U) Q W Y m � CD dlobh Lo 2 Q � LL Z U) cfl Q M Q O Q n M C) ° -X M W Q CO O W 11 <O °° JZ om JU)<( m w WWU) z0 ED 0 :D 00Q Lo a � L O U cn L Ch u c6 u- cz)E V Z CD Q O rn O co _ co m n,/ C � LL uj J � i _0 U O o Lm a) CL W m o 4:� -- :3 0 12 Q LU U) w U) Ch 1. ° a)uj M H LL +J a O O w z m o W Z l i Manuel Reyes - Otalora, R.A. AR -7319 MARK DATE DESCRIPTION PS 5.5.2011 PERMIT SET W J Q O U) O I- O Z W Q U) 0 PROJ. NO: BHSF 2009 -57 Z CAD FILE: DESIGN BY: Q 2 DRAWN BY: 0 O LL CHECKED BY: m M x d' N SHEETTITLE O F- W Z_ a A 501 1- H 2i SHEET OF uJ 0_