11-435-007ABBREVIATIONS
C7 '9 CT �+ TRACK LIGHTING OUTLET W/RXTURE
POWER AND DIAGRAMS
19.
TYPE 8 INDICA .QTY & LENGTH AS SHOWN.
15A,125V,2 POLE, 3 WIRE GROUNDING
OBVIOUSLY AND REASONABLY NECESSARY TO COMPLETE THE INSTALLATION.
DOOR CH
DUPLEX RECEPTACLE, WHITE, NEMA 5 -15R
FIRE DETECTION AND ALARM SYMBOLS
CH
15A.125V,2 POLE, 3 WIRE GROUNDING
CONTROL WIRING.
NOTE. • THE FOLLOWING SUBSCRIPTS ARE USED TO
DUPLEX RECEPTACLE, WHITE, NEMA 5 -15R
F LOCATION OF SUBSCRIPT.
INDICATE VARIOUS TYPES OF SWITCHES
TOP HALF SWITCH
X
SINGLE POLE
20A, 125V, 2 POLE, 3 WIRE GROUNDING
NOTE. THE FOLLOWING SUBSCRIPTS ARE
DOUBLE POLE
DUPLEX RECEPTACLE, NEMA 5--20R
USED TO INDICATE VARIOUS TYPES
THREE WAY
THE CONTRACTOR IS REFERRED TO THE ARCHITECTURAL, STRUCTURAL AND
OF FIRE ALARM STATIONS
USE RIGID GALVANIZED STEEL CONDUIT WHERE EXPOSED OUTDOORS, OR WHERE
I TYPE DUPLEX RECEPTACLE INTERRUPTION, BUILT IN GROUND FAULT I RUPTION,
(NO SUBSCRIPT) MANUAL STATION
FOUR WAY
ABOVE COUNTER OR 48"
TE
THERMAL FOR FRACTIONAL
5MA, 15A. 125V, 3 WIRE WHITE
S SPEAKER/HORN
HORSEPOWER MOTOR
15A,125V,2 POLE, 3 WIRE GROUNDING
AND OBE LIGHT COMBINATION UNIT
PILOT LIGHT
QUAD RECEPTACLE. WHITE, NEMA 5 -15R
S STROBE LIGHT
LIGHTED HANDLE
20A. 125V, 2 POLE, 3 WIRE GROUNDING
SINGLE RECEPTACLE, WHITE, N 5
�_ SPEAKER
KEY OPERATED
-20R
CFA
MOTION SENSOR
GFI TYPE DUPLEX RECEPTACLE WITH
LOCATION OF SUBSCRIPT.
GFCI
BUILT IN GROUND FAULT INTERRUPTION,
5MA, 15A, 125V, 3 WIRE, WHITE
@X SMOKE DETECTOR
23.
FLOOR MOUNTED RECEPTACLE 15A,
NOTE: THE FOLLOWING SUBSCRIPTS ARE
USED TO INDICATE VARIOUS TYPES
CONTRACTOR SHALL SUBMIT REQUEST FOR SUBSTITUTIONS PRIOR TO BIDDING
125V, 3 WIRE, GROUNDING TYPE, WHITE,
OF SMOKE DETECTORS
N 5 -15R BY WIREMOLD 8800 SERIES.
24.
FLEXIBLE CONDUIT SHALL BE USED FOR CONNECTIONS TO VIBRATING EQUIPMENT.
CEILING MOUNTED JUNCTION BOX WITH COVER U.O.N.
(NO SUBSCRIPT) PHOTOELECTRIC
W MOUNTED JUNCTION BOX C U.O.N.
D .FOR DUCTWORK
MARRED DURING SHIPMENT OR INSTALLATION.
25.
A SINGLE STATION WrTH
8.
MOTOR SIZE AS INDICATED ON DRAWINGS
AUXILIARY CONTACT
120VAC, 9 VOLT BATTERY
FUSES SHALL BE BUSSMAN "FUSTRON" DUAL - ELEMENT, TIME DELAY, OR EQUAL,
BACK -UP
KEY PAD(DIMMING EM) DESIGNATION AS INDICATED
9.
THE CONTRACTOR SHALL BE A LICENSED MASTER ELECTRICIAN.
27.
E WITH AUXILIARY CONTACT'S FOR
10.
SPECIAL PURPOSE RECEPTACLE
ELEVATOR RECALL
PROVIDE ALL ELECTRICAL CONTROLLERS, DISCONNECT SWITCHES AND
PLUG -IN RECEPTACLE STRIP
LOCATION OF SUBSCRIPT.
i
TELEPHONE WALL OUTLET
@ X AUTOMATIC HEAT DETECTOR
THE ELECTRICAL CONTRACTOR SHALL PROVIDE TEMPORARY POWER AND LIGHT-
29.
NOTE. THE FOLLOWING SUBSCRIPTS ARE
42
DOUBLE TELEPHONE WALL OUTLET
USED TO INDICATE VARIOUS TYPES
BRANCH CIRCUITS BETWEEN THE PHASES OF THE SYSTEM REGARDLESS OF CIR-
OF HEAT DETECTORS
FLOOR MOUNTED HONE Q
(NO SUBSCRIPT) FIXED TEMPERATURE, 136 DEG.
Q
DATA /PHONE OUTLET
H FIXED TEMPERATURE, 190 DEG.
GENERAL AND MECHANICAL CONSTRUCTION. SHOULD ELECTRICAL WORK BE IN-
C COMBINATION, 136 DEG.
HVAC CONTROLS ARE TO BE FURNISHED BY MECHANICAL OR CONTROLS
SION WALL OUTLET
STALLED WHICH INTERFERES WITH THE WORK OF THE OTHER CONTRACTORS,
2
DOUBLE TELEVISION WALL OUTLET
INPUT/OUTPUT INTERFACE MODULE
SUCH WORK SHALL BE CHANGED AT NO ADDITIONAL COST TO THE OWNER.
BUSDUCT OR WIREWAY
R FAN SHUTDOWN RELAY
20 AMP CIRCUITS FROM 100 FT. TO 200 FT. ONE -WAY, USE #10 WIRE:
SAFETY SWITCH, NOT FUSED UNLESS
AT THE COMPLETION OF THE WORK, THIS CONTRACTOR SHALL REMOVE ALL
X
OTHERWISE SHOWN.
RUBBISH CAUSED BY HIS WORK AND SHALL THOROUGHLY CLEAN ALL ELECTRICAL
AMP, POLES, FUSE SIZE
CIRCUIT DESIGNATION
k
COMBINATION MAGNETIC MOTOR STARTER
BRANCH CIRCUIT HOMERUN
J
WITH FUS113LE DISCONNECT SWITCH
.-- --» (ARROWHEADS INDICATE NUMBER OF HOMERU
X
SATISFACTORILY PRIOR TO FINAL ACCEPTANCE.
CIRCUITS)
ALL WORK SHALL BE GUARANTEED FREE FROM DEFECTS FOR A PERIOD OF ONE
AMP, POLES, FUSE SIZE STARTER SIZE
�,.
YEAR FROM DATE OF FINAL ACCEPTANCE.
-° CONDUIT RISER UP
PASS AND JUNCTION BOXES ARE INSTALLED IF REQUIRED.
MISCELLANEOUS SYMBOLS
_..
34.
PROVIDE A GREEN COLOR GROUNDING CONDUCTOR SIZED PER NEC IN ALL
CONDUIT RISER DOWN
2
NOTES: REFERENCE SYMBOLS: D "SEE NOTE IV
FEEDERS AND BRACH CIRCUITS.
16.
LIGHTING
�' STUB INTO ACCESSIBLE CORRIDOR CEILING
SPACE, UNLESS OTHERWISE NOTED
REFERENCE BOLS: DENOTES uGHTnXTURE WMINAIRE TYPE
, °-° - , INDICATES CIRCUIT CONTINUATION.
Q
CEILING LIGHT OUTLET W/FIXTURE
17.
ALL ELECTRICAL EQUIPMENT SHALL BE COMMERCIAL SPECIFICATION GRADE
CONDUFT SEAL FrMNG FOR HAZARDOUS
BRACKET LIGHT OUTLET W/F1XTURE
AREAS
CEILING LIGHT OUTLET W/FIXTURE
GROUNDING CONDUCTOR
WIRING DEVICES SHALL BE SPECIFICATION GRADE. DECORATOR STYLE WHITE COLOR.
CONNECTED TO ALTERNATE SOURCE,
BRACKET LIGHT OUTLET W/FIXTURE
CONNECTED TO ALTERNATE SOURCE.
ABBREVIATIONS
C7 '9 CT �+ TRACK LIGHTING OUTLET W/RXTURE
THE CONTRACTOR SHALL FURNISH AND INSTALL ALL MINOR ITEMS WHICH ARE
19.
TYPE 8 INDICA .QTY & LENGTH AS SHOWN.
VOLTAGE
OBVIOUSLY AND REASONABLY NECESSARY TO COMPLETE THE INSTALLATION.
DOOR CH
A.F.F.
MOUNT
CH
W.P.
CONTROL WIRING.
NOTE. • THE FOLLOWING SUBSCRIPTS ARE USED TO
MTD
INDICATE VARIOUS TYPES OF SWITCHES
LINE
(NO SUBSCRIPT)
SINGLE POLE
ALL WIRING MUST BE IN CONDUIT. UNLESS SPECIFIED OTHERWISE, A PULL WIRE
2
DOUBLE POLE
GND
OR CORD SHALL BE INSTALLED IN ALL EMPTY CONDUITS.
THREE WAY
THE CONTRACTOR IS REFERRED TO THE ARCHITECTURAL, STRUCTURAL AND
21.
USE RIGID GALVANIZED STEEL CONDUIT WHERE EXPOSED OUTDOORS, OR WHERE
J.B.
4
FOUR WAY
EXPOSED IN ANY LOCATIONS SUBJECT TO MECHANICAL INJURY. EMT MAY BE
TE
THERMAL FOR FRACTIONAL
N.T.S.
USED ELSEWHERE, NO ALUMINUM CONDUIT WILL BE PERMITTED. PVC MAY BE USED
HORSEPOWER MOTOR
A.H.U.
P
PILOT LIGHT
L
LIGHTED HANDLE
EMT
K
KEY OPERATED
GR /G.F.C.I.
M
MOTION SENSOR
ALL MATERIALS SHALL BE NEW, OF TYPES AND MAKES CALLED FOR, OR AP-
M
CEILING MOUNTED MOTION SENSOR
1.
THE CONTRACTOR SHALL FURNISH AND INSTALL ALL MINOR ITEMS WHICH ARE
19.
ALL CONDUCTORS SHALL BE COPPER, UNLESS OTHERWISE NOTED, 60OV; X10 AND
VOLTAGE
OBVIOUSLY AND REASONABLY NECESSARY TO COMPLETE THE INSTALLATION.
CEILING
SMALLER, TYPE THHN/THWN; #8 AND LARGER, TYPE THWN; X12 MINIMUM EXCEPT
MOUNT
SENSOR
CONTROL WIRING.
2.
BIDDERS SHALL VISIT THE SITE AND FAMILIARIZE THEMSELVES WITH ALL CONDI-
BLACK
LINE
TIONS SURROUNDING THE WORK.
20.
ALL WIRING MUST BE IN CONDUIT. UNLESS SPECIFIED OTHERWISE, A PULL WIRE
CEILING
MOUNT
OR CORD SHALL BE INSTALLED IN ALL EMPTY CONDUITS.
3.
THE CONTRACTOR IS REFERRED TO THE ARCHITECTURAL, STRUCTURAL AND
21.
USE RIGID GALVANIZED STEEL CONDUIT WHERE EXPOSED OUTDOORS, OR WHERE
WATTAGES TO BE CONTROLLED BY A
MECHANICAL PLANS AND SPECIFICATIONS. SUCH PLANS AND SPECIFICATIONS ARE
IS 800W/10V
EXPOSED IN ANY LOCATIONS SUBJECT TO MECHANICAL INJURY. EMT MAY BE
TO BE CONSIDERED PART OF THE ELECTRICAL CONTRACT DOCUMENTS.
USED ELSEWHERE, NO ALUMINUM CONDUIT WILL BE PERMITTED. PVC MAY BE USED
4.
DRAWINGS ARE DIAGRAMMATIC AND INTENDED TO SHOW APPROXIMATE LOCA-
WHERE BURIED UNDER GRADE OR EMBEDED IN CONCRETE SLABS OR WALLS.
TIONS AND ARRANGEMENTS ONLY UNLESS OTHERWISE NOTED
22.
ENT MAY BE USED WHERE EMBEDDED IN SLABS IN ACCORDANCE
WITH NEC ART 331.
5.
ALL MATERIALS SHALL BE NEW, OF TYPES AND MAKES CALLED FOR, OR AP-
PROVED EQUAL-
23.
ALL CONDUITS THROUGH ROOF SHALL PENETRATE ROOF USING PROPER APPROVED
6.
CONTRACTOR SHALL SUBMIT REQUEST FOR SUBSTITUTIONS PRIOR TO BIDDING
ROOF FLASHING.
IN WRITING TO THE ENGINEER.
24.
FLEXIBLE CONDUIT SHALL BE USED FOR CONNECTIONS TO VIBRATING EQUIPMENT.
7.
CONTRACTOR SHALL TOUCH UP OR REFINISH THE FACTORY FINISH OF EQUIPMENT
"SEALTITE" WHERE USED OUTDOORS.
MARRED DURING SHIPMENT OR INSTALLATION.
25.
ELECTRICAL EQUIPMENT EXPOSED TO WEATHER MUST BE WEATHERPROOF.
8.
THE ELECTRICAL INSTALLATION SHALL MEET THE APPROVAL OF THE GOVERNING
26.
FUSES SHALL BE BUSSMAN "FUSTRON" DUAL - ELEMENT, TIME DELAY, OR EQUAL,
AUTHORITIES AND THE OWNER'S REPRESENTATIVES BEFORE ACCEPTANCE.
OR AS CALLED FOR ON DRAWINGS.
9.
THE CONTRACTOR SHALL BE A LICENSED MASTER ELECTRICIAN.
27.
PROVIDE TYPEWRITTEN INDEX CARDS FOR ALL PANELS.
10.
THE ENTIRE INSTALLATION SHALL BE PERFORMED IN A FIRST -CLASS WORK-
2.
PROVIDE ALL ELECTRICAL CONTROLLERS, DISCONNECT SWITCHES AND
MANLIKE MANNER.
WITH PLASTIC EMBOSSED LABELS.
11.
THE ELECTRICAL CONTRACTOR SHALL PROVIDE TEMPORARY POWER AND LIGHT-
29.
THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROPERLY BALANCING ALL
ING AS REQUIRED FOR ALL TRADES.
BRANCH CIRCUITS BETWEEN THE PHASES OF THE SYSTEM REGARDLESS OF CIR-
CUITING INDICATED.
12.
ELECTRICAL WORK SHALL NOT INTERFERE WITH CLEARANCES REQUIRED FOR
GENERAL AND MECHANICAL CONSTRUCTION. SHOULD ELECTRICAL WORK BE IN-
30.
HVAC CONTROLS ARE TO BE FURNISHED BY MECHANICAL OR CONTROLS
STALLED WHICH INTERFERES WITH THE WORK OF THE OTHER CONTRACTORS,
CONTRACTOR INCLUDING CONTROL WIRING.
SUCH WORK SHALL BE CHANGED AT NO ADDITIONAL COST TO THE OWNER.
31.
20 AMP CIRCUITS FROM 100 FT. TO 200 FT. ONE -WAY, USE #10 WIRE:
13.
AT THE COMPLETION OF THE WORK, THIS CONTRACTOR SHALL REMOVE ALL
OVER 200 FT., USE #8 WIRE.
RUBBISH CAUSED BY HIS WORK AND SHALL THOROUGHLY CLEAN ALL ELECTRICAL
EQUIPMENT.
32.
ALL EQUIPMENT AND SYSTEMS SHALL BE DEMONSTRATED TO BE FUNCTIONING
SATISFACTORILY PRIOR TO FINAL ACCEPTANCE.
14.
ALL WORK SHALL BE GUARANTEED FREE FROM DEFECTS FOR A PERIOD OF ONE
33.
MAINTAIN THE FIRE TING OF ALL PARTITIONS WALLS THROUGH WHICH CONDUIT
YEAR FROM DATE OF FINAL ACCEPTANCE.
PASS AND JUNCTION BOXES ARE INSTALLED IF REQUIRED.
15.
ALL ITEMS OF ELECTRICAL EQUIPMENT ASSOCIATED WITH THE CONTROL OF
34.
PROVIDE A GREEN COLOR GROUNDING CONDUCTOR SIZED PER NEC IN ALL
ELECTRIC APPARATUS SHALL BE IDENTIFIED.
FEEDERS AND BRACH CIRCUITS.
16.
NOMINAL MOUNTING HEIGHT OF DEVICES IN EXPOSED CONCRETE BLOCK, OR
BRICK WALLS SHALL ALL OCCUR WITHIN A STRUCTURAL COURSE. A MINIMUM
AMOUNT OF BLOCK, OR BRICK WALLS SHALL BE CUT.
17.
ALL ELECTRICAL EQUIPMENT SHALL BE COMMERCIAL SPECIFICATION GRADE
HEAVY DUTY, AND UL APPROVED UNLESS SPECIFIED OTHERWISE.
18.
WIRING DEVICES SHALL BE SPECIFICATION GRADE. DECORATOR STYLE WHITE COLOR.
BOXES FOR LINE VOLTAGE WIRING SHALL BE SQUARE.
Cu -9, CW-IC, PM OR -10
CM -9, CM -10, CM -PDT OR CM- PDT -10 WITH
SINGLE LOAD
ti Jam# __ ► � '► ►1
I IL tl ' O .
UILOING SEGO
Arcbftechre PlanNing CwstucfionM on
•
Architects a a
94 - Road Suite 200
1y, • . Gables, •
'7 i •6 3 i Fax r #• i rY •
Firm License Number.- "Ili •
- r
+• Bapfist Health,
*..
South I ,►
of •
Ir I
�- •Li#e-x r=
8900 North Kendall Drive,
Miami, Florida
r• "
ISSUE RECORD;
04/11/11 PERMIT ISSUE
WHITE
LINE
VOLTAGE
BLACK
CEILING
MOUNT
SENSOR
BLACK
H N
BLACK
LINE
VOLTAGE
BLACK
CEILING
MOUNT
SENSOR
WHITE
PLEASE NOTE THAT THE
TOTAL
WATTAGES TO BE CONTROLLED BY A
LINE VOLTAGE SENSOR
IS 800W/10V
AND I20OW FOR 277V
Cu -9, CW-IC, PM OR -10
CM -9, CM -10, CM -PDT OR CM- PDT -10 WITH
SINGLE LOAD
ti Jam# __ ► � '► ►1
I IL tl ' O .
UILOING SEGO
Arcbftechre PlanNing CwstucfionM on
•
Architects a a
94 - Road Suite 200
1y, • . Gables, •
'7 i •6 3 i Fax r #• i rY •
Firm License Number.- "Ili •
- r
+• Bapfist Health,
*..
South I ,►
of •
Ir I
�- •Li#e-x r=
8900 North Kendall Drive,
Miami, Florida
r• "
ISSUE RECORD;
04/11/11 PERMIT ISSUE