11-382-044
(:d IL w w X w w J_ .. U_ w _ t Z w J LL w 0 O J d FIRE PROTECTION NOTES 1. PROVIDE WORKING DRAWINGS FROM THE ENGINEERED CONTRACT DRAWINGS AND SPECIFICATIONS. THE DRAWINGS SHALL MEET ALL OF THE REQUIREMENTS FOR WORKING DRAWINGS PER NFPA 13. PROVIDE SPRINKLERS AND PIPING IN LOCATIONS AND CONFIGURATION INDICATED; HOWEVER, THE CONTRACTOR SHALL COORDINATE THE LOCATION AND ELEVATION OF ALL SPRINKLERS AND PIPING WITH ALL BUILDING COMPONENTS AND SYSTEMS. PIPE SIZES SHALL NOT BE LESS THAN INDICATED ON THE DRAWINGS. 2. OBTAIN A PERMIT FOR THE WORKING DRAWINGS IN ACCORDANCE WITH LOCAL DRAWINGS AND STATE REQUIREMENTS. 3. PROVIDE WET —PIPE SPRINKLER SYSTEMS IN ACCORDANCE WITH 2007 FLORIDA BUILDING CODE, 2007 FLORIDA FIRE PREVENTION CODE, 2002 NFPA 13, AND LOCAL REQUIREMENTS. ALL PIPING, SPRINKLERS, AND COMPONENTS TO BE UL LISTED AND FM APPROVED FOR AUTOMATIC SPRINKLER SYSTEMS. 4. STORAGE ROOMS, EQUIPMENT ROOMS, AND SIMILAR AREAS ARE ORDINARY HAZARD, GROUP 1; AND EXAM ROOM, PATIENT ROOMS, LOBBY AREAS AND RESTROOMS ARE LIGHT HAZARD. THE SYSTEM IS DESIGNED IN ACCORDANCE WITH NFPA 13. THE SYSTEM ARE DESIGNED TO PROVIDE 0.10 AND 0.15 GPM /SQ. FT. FOR LIGHT AND ORDINARY GROUP 1 AREAS, RESPECTIVELY. 5. THE SPRINKLER SPACING SHALL BE AS INDICATED ON THE DRAWINGS BUT SHALL NOT EXCEED 225 SQ. FT AND 130 SQ. FT. FOR LIGHT AND ORDINARY HAZARD, RESPECTIVELY, EXCEPT WHERE EXTENDED COVERAGE SPRINKLERS ARE SHOWN. G. COORDINATE ROUTING OF PIPING, ETC. WITH PLUMBING AND MECHANICAL (HVAC) ROUTING. PIPING SHALL NOT BE LOCATED ABOVE ELECTRICAL PANELS, ETC. PER NFPA 70. 7. ALL TEST/DRAIN LINES (MORE THAN 5 GALLONS) SHALL DISCHARGE DIRECTLY TO THE EXTERIOR WITH THE APPROPRIATE SPLASH PROTECTION. AUXILIARY DRAINS MAY DISCHARGE INTO MECHANICAL ROOM FLOOR DRAINS. DRAINS SHALL BE SIZED IN ACCORDANCE WITH NFPA 13 AND NFPA 14. WORKING DRAWINGS SHALL INDICATE THE LOCATION OF ALL TEST/DRAIN VALVES AND DISCHARGE POINTS. & ALL PIPES SERVING A SINGLE SPRINKLER ARE 1 INCH MINIMUM. PROVIDE ASTM A 53 SCHEDULE 40 STEEL PIPE FOR WELDED, THREADED, AND GROOVED FITTINGS ONLY. PROVIDE ASTM A135 OR A795 SCHEDULE 10 STEEL PIPE FOR WELDED OR ROLLED — GROOVE FITTINGS ONLY. 9. PROVIDE 1/2 —INCH RECESSED PENDENT OR CONCEALED SPRINKLERS (ORDINARY TEMPERATURE) IN INTERIOR SPACES WITH FINISHED CEILINGS, AS INDICATED ON THE DRAWINGS. SPRINKLERS SHALL BE CENTERED IN CEILING TILE (BOTH DIRECTIONS). SPRINKLERS IN GYPSUM BOARD CEILINGS SHALL BE INSTALLED UNIFORMLY AND CENTERED WITH RESPECT TO LIGHTS, ETC. SPRINKLERS IN AREAS WITHOUT CEILINGS SHALL BE PENDENT OR UPRIGHTS IN ACCORDANCE WITH NFPA 13. PROVIDE OTHER SPRINKLERS AS INDICATED ON THE DRAWINGS. COORDINATE THE LOCA11ON AND ELEVATION OF SPRINKLERS WITH RESPECT TO STRUCTURAL MEMBERS AND OTHER OBSTRUCTIONS IN ACCORDANCE WITH NFPA 13. 10. PROVIDE HANGERS IN ACCORDANCE WITH NFPA 13. HANGERS TYPES AND LOCATIONS IN THE CONCRETE MEMBERS MUST BE SUBMITTED TO AND APPROVED BY THE STRUCTURAL ENGINEER. CODES 1. FLORIDA BUILDING CODE 2007 EDITION W/ 2008 AND 2009 REVISIONS 2. FLORIDA MECHANICAL CODE, 2007 EDITION W/ 2008 AND 2009 REVISIONS 3. FLORIDA PLUMBING CODE, 2007 EDITION W/ 2008 AND 2009 REVISIONS 4. GUIDELINES FOR DESIGN AND CONSTRUCTION OF HOSPITAL AND HEALTH CARE FACILITIES (GUIDELINES 2006 EDITION) 5. NFPA 101 (2006) 6. FLORIDA ADMINISTRATIVE CODE 59A -3, (MARCH 2003) 7. NFPA 99 (2005) E. STATE FIRE PROVEN11ON CODE 4A60 (2001) 9. AIA GUIDELINES (2006) 10. NFPA 13 (2002) FIRE PROTECTION SYMBOLS ALL SYMIIOLS SHOWN MAY NOT APPEAR IN ALL DRAWINGS. SYMBOLS ARE SHOWN SCHEMATIC AND MAY NOT BE TO SCALE. SYMBOL DESCRIPTION — EX — EXISTING PIPING TO REMAIN X —X—>(— X EXISTING PIPING TO BE REMOVED O CONNECT NEW TO EXISTING — F FIRE PROTECTION (STANDPIPE, SPRINKLER, SERVICE) —DFS— DRY FIRE STANDPIPE PIPING — SP — SPRINKLER PIPING (SPRK.) —SDR— SPRINKLER DRAIN RISER PIPING —DSP— DRY SPRINKLER PIPING — PAP PRE- ACTION SPRINKLER PIPING �- GATE VALVE GLOBE VALVE T PRESSURE REGULATION VALVE (PRV) --- CHECK VALVE WITH AUTOMATIC BALL DRIP D VALVE IN VERTICAL —14;- L OS & Y VALVE SUPERVISED (HORIZ. POSITION /VERY. POSITION) O INDICATING BUTTERFLY VALVE SUPERVISED (HORIZ. POSITION /VERT. POSITION) FCA SPRINKLER SYSTEM FLOOR CONTROL ASSEMBLY DOUBLE CHECK VALVE ASSEMBLY (D.C.V.A.) WITH OS jc Y VALVES SUPERVISED A T FLOW SWITCH 0-i�-3 FIRE HOSE VALVE rrrrrrm FIRE HOSE CABINET (SURFACE MOUNTED) -73M31= FIRE HOSE CABINET (RECESSED) Qn 2 —WAY SIAMESE FIRE DEPARTMENT CONNECTION T DIRECTION OF SLOPE � DIRECTION OF FLOW o CAP OUTLET OR PLUGGED OUTLET Ilk — UNION � QUICK RESPONSE CONCEALED SPRINKLER d QUICK RESPONSE RECESSED PENDENT SPRINKLER 0 QUICK RESPONSE UPRIGHT SPRINKLER ► QUICK RESPONSE SIDEWALL SPRINKLER ABBREVIATIONS AFF ABOVE FINISH FLOOR AFG ABOVE FINISH GRADE A/C ABOVE HUNG CEILING AP ACCESS PANEL OR DOOR BFF BELOW FINISH FLOOR I/F BELOW FLOOR I/G BELOW GRADE GC GENERAL CONTRACTOR INV INVERT I.E. INVERT ELEVATION MH MANHOLE PRV PRESSURE REDUCING VALVE FIRE PROTECTION SHEET LIST DWG No. DRAWING TITLE XM FO.00 GENERAL INFORMATION — FIRE PROTECTION NTS F2.30 THIRD FLOOR PLAN — FIRE PROTECTION ON = 1'—ON r— i I a4•a i!• f • !•G*• Y•• f • • Y f Y Y f a a i +J • • ! - • f • • • & " s 6600 a ! • r • • • • s r a • a • • , • J• ea• • at • Ago I<S J a it •a r2121 Ponce de Leon Blvd., Suite 350 Coral Gables, FL 33134 • �' •. s ° "'' V a 1692 569. • • Professional Consulting Engineers phone: 305. a . OWNER • r � • fax: 305.569.1693 r * • a • u a • • • R.EAPTIS'v ti- ALTH SOUTH FLORIDA Austin Dallas • Denver • Houston • Nashville 6865 RED ROAD Miami Phoenix Richmond - Washington D.C. CORAL GABLES, FLORIDA 33146 cord project number: 410393.000 ARCHITECT EB00007658 FL AA F000119 HKS ARCHITECTS, INC. 1221 BRICKELL AVENUE, SUITE 1220 MIAMI, FL 33131 M.E.P. ENGINEERS CCRD PARTNERS 2121 PONCE DE LEON BOULEVARD SUITE 350 CORAL GABLES, FL 33134 INTERIORS IN.DESIGN, INC. 2080 NW BOCA RCTON BOULEVARD SUITE 3 BOCA RATON, FL 33146 KEY PLAN W �U�1t��liiNrrr r•• Cr iv REVISION - ----- -------- ----. f i)AD {.. (.) it �! HKS PROJECT NUMBER 14262.000 DATE 04.11.2011 ISSUE BIDDING & PERMITTING SET SHEET TITLE GENERAL INFORMATION FIRE PROTECTION SHEET NO. © 2011 HKS, INC. IF 10 E 10 0 I� W M M M iPOO O qu Qn � o aci r�•O�� V1 � a KEY PLAN W �U�1t��liiNrrr r•• Cr iv REVISION - ----- -------- ----. f i)AD {.. (.) it �! HKS PROJECT NUMBER 14262.000 DATE 04.11.2011 ISSUE BIDDING & PERMITTING SET SHEET TITLE GENERAL INFORMATION FIRE PROTECTION SHEET NO. © 2011 HKS, INC. IF 10 E 10 0