11-382-039IL tr X C ❑ W J T LL t z w U_ Ili 0 J PLUMBING FIXTURE SCHEDULE DESIG DESCRIPTION WASTE SINK INTEGRAL WITH COUNTER AS SPECIFIED ON ARCHITECTURAL DRAWINGS, CHICAGO HYTRONIC 116.103.4.1 SENSOR ACTIVATED GOOSENECK S -1 SINK FAUCET WITH UNDERCOUNTER THERMOSTATIC MIXING VALVE, AC TO DC TRANSFORMER k 1.5 GPM ANTIBACTERIAL COMPOUND COATED REMARKS LAMINAR FLOW CONTROL; ELKAY LK -1N STAINLESS STEEL GRID STRAINER AND TAILPIECE; McGUIRE # 8912 CAST BRASS P -TRAP; McGUIRE # HOT H171LK SUPPLIES THIRD FLOOR PLAN — PLUMBING SINK INTEGRAL WITH COUNTER AS SPECIFIED ON ARCHITECTURAL DRAWINGS; CHICAGO HYTRONIC 116.103.AB.1 SENSOR ACTIVATED GOOSENECK S -2 SINK FAUCET WITH UNDERCOUNIER THERMOSTATIC MIXING VALVE, AC TO DC TRANSFORMER k 1.5 GPM ANTIBACTERIAL COMPOUND COATED 1 /a" = 1s —ON LAMINAR FLOW CONTROL; ELKAY LX-181 STAINLESS STEEL GRID STRAINER AND TAILPIECE; McGUIRE # 8912 CAST BRASS P -TRAP; McGUIRE # PLUMBING RISERS H171LK SUPPLIES SINK NOTES: 1. VERIFY ALL MOUNTING HEIGHTS WITH ARCHITECTURAL DRAWINGS. 2" 2. ALL P -TRAPS SHALL HAVE INTEGRAL CLEANOUT PLUGS. PLUMBING FIXTURE CONNECTION SCHEDULE MARK TYPE OF FIXTURE WASTE VENT TRAP WATER REMARKS C OLD HOT P2.30 THIRD FLOOR PLAN — PLUMBING 1 /8" = 1' -0" P3.30 THIRD FLOOR PLAN — MEDICAL GAS 1 /a" = 1s —ON P4.01 PLUMBING RISERS S SINK 2" 2" 1 1/2" 1/2" 1/20 RECESSED BOX WALL HYDRANT X X X EXISTING PIPING TO BE REMOVED PIPING TO BE ELECTRICALLY HEAT TRACED YARD HYDRANT # # # SS — CODES 1. FLORIDA BUILDING CODE 2007 EDITION W/ 2008 AND 2009 REVISIONS 2. FLORIDA MECHANICAL CODE, 2007 EDIT10N W/ 2008 AND 2009 REVISIONS 3. FLORIDA PLUMBING CODE, 2007 EDITION W/ 2008 AND 2009 REVISIONS 4. GUIDELINES FOR DESIGN AND CONSTRUCTION OF HOSPITAL AND HEALTH CARE FACILITIES (GUIDELINES 2006 EDITION) 5. NFPA 101 (2006) 6. FLORIDA ADMINISTRATIVE CODE 59A -3, (MARCH 2003) 7. NFPA 99 (2005) 8. STATE FIRE PROVENTION CODE 060 (2001) 9.` AIA GUIDELINES (2006) 10. NFPA 13 (2002) GENERAL NOTES A. LOCATION OF EXISTING SYSTEMS AND APPURTENANCES HAVE BEEN TAKEN FROM "AS- BUILT' DOCUMENTS. THE CONTRACTOR SHALL FIELD VERIFY EXACT LOCATION OF ALL EXISTING PLUMBING EQUIPMENT AND APPURTENANCES THAT WILL REQUIRE SOME ME OF MODIFICATION DUE TO THE RENOVATION AND /OR NEW CONSTRUCTION OF THIS CONTRACT PRIOR TO PRICING AND COMMENCEMENT OF WORK. B. REMOVE EXISTING PIPING, WHERE NOTED OR REQUIRED, TO BEYOND FINISHED SURFACES AND CAP AS REQUIRED OR INDICATED ON PLANS. VERIFY EXACT LOCATION OF EXISTING PLUMBING AT SITE. C. ANY EXISTING PLUMBING RISER LOCATED IN WALLS /CHASES INDICATED TO BE DEMOLISHED MUST BE RELOCATED TO A CONVENIENT LOCATION. D. CONTRACTOR TO COORDINATE WITH ALL DISCIPLINES AND ALL EXISTING SYSTEMS PIPING ROUTING BEFORE INSTALLATION. IF NECESSARY, REROUTE EXISTING SYSTEMS TO ACCOMMODATE NEW PIPING. E. REFER TO THE ARCHITECTURAL PHASING PLAN FOR THE PHASING OF CONSTRUCTION. WORK SHALL BE SCHEDULED AND PERFORMED IN SEQUENCE NTH THE ARCHITECTURAL PHASING PLAN. F. PROVISIONS SHALL BE MADE BY THE CONTRACTOR TO PREVENT DISRUPTING ADJACENT AREAS OF THE PHASE IN WHICH WORK IS BEING PERFORMED. G. PROVIDE ADDITIONAL VALVES, TAPS, TEMPORARY PIPING, ETC. AS NECESSARY TO PROVIDE UNINTERRUP10 SERVICE TO AREAS OUTSIDE OF THE PHASE IN WHICH WORK IS BEING PERFORMED. H. ALL WORK SHALL BE PERFORMED IN STRICT COORDINATION WITH FACILITY SCHEDULES AND OCCUPANCIES. CONTRACTOR SHALL COORDINATE NTH FACILITY REPRESENTATIVE. I. COORDINATE WITH OTHER TRADES THE LOCATION AND ROUTING OF ALL PLUMBING, MEDICAL GAS k FIRE PROTECTION SYSTEMS. J. ALL PIPING SHALL RUN IN WALLS /CHASES /ABOVE CEILING. WERE EXPOSED PIPING HAS TO BE INSTALLED PROVIDE CHROME PLATTED PIPING. OBTAIN ARCHITECT'S APPROVAL PRIOR TO INSTALLATION OF ANY EXPOSED PIPING. K. VALVES NOT LOCATED IN ZONE BOXES SHOULD BE LOCKING ME. MEDICAL GAS SYSTEM TO BE NFPA 99 COMPLIANT. L WORK IN THE NON RENOVATED AREAS TO BE PERFORMED AFTER HOURS OR ON NON WORKING DAYS. PLUMBING SHEET LIST DWG No. DRAWING TITLE 52LE 80.00 GENERAL INFORMA11ON — PLUMBING NTS PD2.30 THIRD FLOOR DEMOLITION !'LAN — PLUMBING 1 /a" = 1' -0" P2.30 THIRD FLOOR PLAN — PLUMBING 1 /8" = 1' -0" P3.30 THIRD FLOOR PLAN — MEDICAL GAS 1 /a" = 1s —ON P4.01 PLUMBING RISERS NTS COLD OR HOT REDUCED PRESSURE PRINCIPLE BACKFLOW PREVENTER R.P.P.B.P.} - HOSE BIBB (H.B.) OR WALL HYDRANT (WH) — EX EXISTING PIPING TO REMAIN — • • U Y • • • • • • • • • U • • • • • • • • • • • ►•U • • LC♦ Y • • • • • •••iY i U i Y W Y i • • i • • • • r ••• • •• • AMA • W W • we •r 12121 Ponce de Leon Blvd., Suite 350 I <S Coral Gables, FL 3313' ". "' W `0 • • W phone: 305.569.1692 ; • • • • ► r OWNS Frofessionol Consulting Engineers • • • f • Y Y • • • • - • `DAPTI;y r riEALTH SOUTH FLORIDA ax: 305.569.1693 Austin Dallas • Denver • Houston • Nashville 6865 RED ROAD Miami Phoenix Richmond - Washington D.C. CORAL GABLES, FLORIDA 33146 ccrd project number: 410393.000 ARCHITECT EB00007658 FL AA F000119 HKS ARCHITECTS, INC. 1221 BRICKELL AVENUE, SUITE 1220 MIAMI, FL 33131 M.E.F. ENGINEERS CCRD PARTNERS 2121 PONCE DE LEON BOULEVARD SUITE 350 CORAL GABLES, FL 33134 INTERIORS IN.DESIGN, INC. 2080 NVV BOCA RATON BOULEVARD SUITE 3 BOCA RATON, FL 33146 PLUMBING SYMBOLS ALL SYMBOLS SHOWN MAY NOT APPEAR IN ALL DRAWINGS. SYMBOLS ARE SHOWN SCHEMATICALLY AND MAY NOT BE TO SCALE. SYMBOL DESCRIPTION SYMBOL DESCRIPTION - DOMESTIC COLD WATER GAUGE COCK — -- — DOMESTIC HOT WATER (1207 UNLESS OTHERWISE NOTED) PRESSURE GAUGE -WITH GAUGE COCK DOMESTIC HOT WATER RETURN (1207 UNLESS OTHERWISE NOTED) n THERMOMETER WITH SHUT -OFF COCK � COLD OR HOT REDUCED PRESSURE PRINCIPLE BACKFLOW PREVENTER R.P.P.B.P.} - HOSE BIBB (H.B.) OR WALL HYDRANT (WH) — EX EXISTING PIPING TO REMAIN — RECESSED BOX WALL HYDRANT X X X EXISTING PIPING TO BE REMOVED PIPING TO BE ELECTRICALLY HEAT TRACED YARD HYDRANT # # # SS — SANITARY SEWER PIPING (SOIL OR WASTE) -L` T SLEEVE THRU WALL SANITARY VENT PIPING EXPANSION LOOP SSD SUB -SOIL DRAIN PIPING, FOOTING DRAIN PIPING — ANCHOR AW ---• ACID WASTE PIPING -- AV — ACID VENT PIPING --® GCS FLOOR CLEANOUT OR GRADE CLEANOUT I.W. INDIRECT WASTE i WC! WALL CLEANOUT - ■ —SED -- SEWAGE EJECTOR DISCHARGE PIPING (PUMPED SANITARY) CO CO CLEANOUT PLUG — CD -�--- CONDENSATE DRAIN PIPING ar sF-� OS & Y VALVE SUPERVISED (HORIZ. POSITION /VERT. POSITION) --- --DPD— DRIP PAN DRAIN PIPING INDICATING BUTTERFLY VALVE SUPERVISED (HORIZ. POSITION /VERT. POSITION) 0 CONNECT NEW TO EXISTING` SD --- STORM DRAIN PIPING (SD) FGA SPRINKLER SYSTEM FLOOR CONTROL ASSEMBLY --- OD — STORM OVERFLOW DRAIN PIPING (OD) DOUBLE CHECK VALVE ASSEMBLY (D.C.V.A.) WITH OS jc Y VALVES SUPERVISED SPD SUMP PUMP DISCHARGE PIPING (PUMPED STORM WATER) FLOW SWITCH — G NATURAL GAS PIPING � � FIRE HOSE VALVE — CA -•-� -- COMPRESSED AIR PIPING rrrrrrm FIRE HOSE CABINET (SURFACE MOUNTED) --- V VACUUM PIPING —ATV— ATMOSPHERIC VENT PIPING (STEAM OR HOT VAPOR) _'_01111= FIRE HOSE CABINET (RECESSED) — F — FIRE PROTECTION (STANDPIPE, SPRINKLER, SERVICE) G-0 2 -WAY SIAMESE FIRE DEPARTMENT CONNECTION — DFS — DRY FIRE STANDPIPE PIPING DIRECTION OF SLOPE — SP -- SPRINKLER PIPING (SPRK.) — DIRECTION OF FLOW --- SDR— SPRINKLER DRAIN RISER PIPING 3 CAP OUTLET OR PLUGGED OUTLET —DSP— DRY SPRINKLER PIPING — UNION —PASP— PRE - ACTION SPRINKLER PIPING 4 --10 4 GATE VALVE — OX — MEDICAL OXYGEN PIPING F�— BUTTERFLY VALVE — MA — MEDICAL AIR PIPING ---- BALL VALVE — MV — MEDICAL VACUUM PIPING -�� GLOBE VALVE —WAG— WASTE ANESTHETIC GAS EVACUATION ~ TEMPERATURE AND PRESSURE RELIEF VALVE N MEDICAL NITROGEN PIPING T GAS COCK / PLUG VALVE —N20— MEDICAL NITROUS OXIDE PIPING SOLENOID VALVE 1P— MASTER ALARM SENSOR PRESSURE REGULA11ON VALVE (PRV) If LOCAL ALARM SENSOR IN -LINE CIRCULATING r-h MEDICAL GAS PIPING DROPS IN WALL FULL SIZE AIR CHAMBER PLUMBING ABBREVIATIONS AFF ABOVE FINISH FLOOR INV INVERT AFG ABOVE FINISH GRADE I.E. INVERT ELEVATION A/C ABOVE HUNG CEILING LT LAUNDRY TRAY AP ACCESS PANEL OR DOOR L -LAV. LAVATORY AC AIR CHAMBER NPW NON POTABLE WATER AD AREA DRAIN MS MOP SINK BASIN BT BATHTUB PD PLANTER DRAIN BFF BELOW FINISH FLOOR PRV PRESSURE REDUCING VALVE B/F BELOW FLOOR RD ROOF DRAIN B/G BELOW GRADE SS SERVICE SINK OR SLOP SINK CSS CLINICAL SERVICE SINK SH SHOWER DS DOWNSPOUT SD SHOWER DRAIN DF DRINKING FOUNTAIN S. -SK. SINK EWC ELECTRIC WATER COOLER UR URINAL FD FLOOR DRAIN VTR VENT THROUGH ROOF FS FLOOR SINK WS WASH SINK FRS FLUSH RIM SINK WH WALL HYDRANT GC GENERAL CONTRACTOR WC WATER CLOSET GCO GRADE CLEANOUT YCO YARD CLEANOUT --� AQUASTAT �I— CHECK VALVE �t CHECK VALVE WITH AUTOMATIC BALL DRIP BACK WATER VALVE CoF D VALVE IN VERTICAL S GAS PRESSURE REGULATOR VALVE BALANCING VALVE STRAINER WITH BLOW -OFF VALVE - - STRAINER HYDRAULIC SHOCK ARRESTOR (SA) VACCUUM BREAKER (VI) —:0 FLOOR DRAIN W/ P -TRAP D• HUB DRAIN (ALL TYPES) (SPECIFY) ® 0 FLOOR DRAIN (ALL TYPES) (SPECIFY) DOUBLE CLEANOUT, 2 -WAY CLEANOUT (GRADE) (D.C.O.) © 2011 HKS, INC. W KE` �.... 064 W LLI u S 0 R "�, / d 1 " i A 1. ` F' , REVISION HKS PROJECT NUMBER 14262.000 DATE 04.11.2011 ISSUE BIDDING & PERMITTING SET SHEET TITLE GENERAL INFORMATION - PLUMBING SHEET NO. QM � M • �^ Imo/ � 0 r/1 oo Poo u u � M a W KE` �.... 064 W LLI u S 0 R "�, / d 1 " i A 1. ` F' , REVISION HKS PROJECT NUMBER 14262.000 DATE 04.11.2011 ISSUE BIDDING & PERMITTING SET SHEET TITLE GENERAL INFORMATION - PLUMBING SHEET NO.