11-313-006
LEGEND HOSPITAL GRADE DUPLEX RECEPT - CRITICAL POWER 20 AMP NEMA 5 -20R (18" A.F.F.). HOSPITAL GRADE QUAD RECEPTACLE - CRITICAL POWER 20 AMP NEMA 5 -20R (18" A.F.F.) 0 TELEPHONE & DATA OUTLET, ONE VOICE AND ON DATA DROPS (4 "X 4 "X 2 1/2" OUTLET BOX) (18" A.F.F.) PROVIDE 3/4" STUB OUT CONDUIT 6" ABOVE CEILING. EXISTING DUPLEX RECEPTACLE - CRITICAL POWER 20A. NEMA 5 -20R (18" A.F.F.). EXISTING QUAD RECEPTACLE - CRITICAL POWER 20 AMP NEMA 5 -20R (18" A.F.F.) LOW VOLTAGE PANELBOARD 120/208V. BRANCH CIRCUIT OR FEEDER WIRING IN CONDUIT. NO TICKS INDICATES 2 # 12 CONDUCTORS & 1 # 12 GROUND IN 3/4" CONDUIT. SHORT TICK MARKS WHEN SHOWN, INDICATES IkH� NUMBER OF * 12 CONDUCTORS. LONG TICK MARKS INDICATES NUMBER OF NEUTRAL (ONE PER CIRCUIT). LONG TICK WITH A DOT INDICATES GROUND. CONDUIT LARGER THAN 3/4" & CONDUCTOR LARGER THAN # 12 SHALL BE AS INDICATED. HOME RUN TO PANEL "A"= PANEL DESIGNATION, A -1,3,5 1,3,5 = CIRCUIT NUMBERS. U.O.N. MINIMUM SIZE fOF 3/4 "C. ONE NEUTRAL PER CIRCUIT REQUIRED. DRAWINGS. HOWEVER MINOR DEVIATIONS MAY BECOME EVIDENT AS THE JOB PROGRESSES. NO ADVANTAGE IS TO BETAKEN BY THE CONTRACTOR BECAUSE THESE MINOR DIFFERENCES. 10. ALL FLOORS, WALLS, AND ROOF PENETRATIONS SHALL BE PROPERLY SEALED -OFF. IF FIRE RATED, AN APPROVED FIRE RETARDANT SEALANT SHALL BE USED. 11. THESE DRAWINGS ARE A GUIDE FOR THE INSTALLATION OF THE RACEWAY SYSTEM AND EQUIPMENT. THEY ARE INTENDED TO SHOW THE GENERAL ARRANGEMENT. DESIGN AND EXTENT OF TNF WORK ANn PARTS v nlu(rRAKARAATfr` TUM r+nKrr©Af --rn© 10 ' •!Y • try _ - - V V W V u W • Y •Y•• W y V I Y W • • • y PROJECT SPECIFICATION •w•. .•. y,•Y wY.• Y • y :woo W • y " :900 • J• •• V Y Y V• Y V 1. SITE INVESTIGATION: PRIOR TO BIDDING THE CONTRACTOR SHALL VISIT THE JOBSITE AND BECOME ACQUAINTED WITH ALL OF THE EXISTING CONDITIONS WHICH WILL AFFECT HIS WORK. FAILURE TO DO SO WILL NOT BE ACCEPTED AS A REASON FOR REQUESTING EXTRA L OU LOUIS J. AGUIRRE &ASSOCIATES, P.A. PAY WHERE THE EXISTING CONDITION RESULTS IN EXTRA MATERIAL OR LABOR, THE CONTRACTOR SHALL SUBMIT IN HIS BID AN AMOUNT THAT WOULD BE SET ASIDE FOR UNIDENTIFIED ITEMS. C 0 n S U I t 1 n g E n g 1 B e e r S 2. THE CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS AND EQUIPMENT NECESSARY FOR THE COMPLETE INSTALLATION OF 9150 South. Dadeland Blvd. * Suite 900 Miami * Florida 33156 * CA 924 THE ELECTRICAL SYSTEMS, ALL IN ACCORDANCE WITH THESE CONSTRUCTION DOCUMENTS. ALL WORK PERFORMED UNDER Telephone 305.670.0141 THIS CONTRACT SHALL COMPLY WITH THE FLORIDA BUILDING CODE 2007 EDITION WITH 2009 REVISIONS AND ALL THE STANDARDS Facsimile 305.670.0144 OF CONSTRUCTION ESTABLISHED BY THE BHSF HOSPITAL INCLUDING, BUT NOT LIMITED TO THE FOLLOWING PUBLICATIONS: A) www.l'aa ax rn CHAPTER 59A -3 FLORIDA ADMINISTRATIVE CODE 2002, B) NFPA 70 -2008, NFPA 72 -2002, NFPA 99 -2005, NFPA 110 -2005, NFPA Project No.: 21002 101 -2006, NFPA 780 -2004 AND C) AIA 2006 AND D) OSHA. 3, MINIMUM STANDARDS: THE MATERIAL, EQUIPMENT, INSTALLATIONS, AND WORKMANSHIP FURNISHED UNDER THIS SECTION SHALL CONFORM AT LEAST TO THE REQUIREMENTS OF THE REGULATING AGENCIES AS LISTED IN ITEM (2) ABOVE. ALL MATERIALS AND EQUIPMENT USED SHALL BE LISTED OR BEAR THE U.L. APPROVAL FOR THEIR INTENDED USE. 4. RESPONSIBILITIES: CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING A COMPLETE INSTALLATION OF THE RACEWAY SYSTEM, EQUIPMENT AND WIRING IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. 5. GUARANTEE: THE CONTRACTOR /SUB- CONTRACTOR SHALL FURNISH A WRITTEN GUARANTEE THAT ALL WORK EXECUTED UNDER THIS CONTRACT SHALL BE FREE FROM DEFECTS OF WORKMANSHIP AND MATERIALS FOR A PERIOD OF ONE YEAR FROM THE DATE OF FINAL ACCEPTANCE AND THAT HE WILL AT HIS OWN EXPENSE, REPAIR OR REPLACE ALL WORK WHICH BECOMES DEFECTIVE DURING THE TIME OF THE GUARANTEE. 6. ALL EQUIPMENT, SYSTEM AND SYSTEM COMPONENTS SHALL BE FROM THE SAME MANUFACTURER AND SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS AND SPECIFICATIONS. 7. RACEWAYS AND FITTINGS: CONDUIT RUNS SHALL BE CONCEALED IN CEILING SPACES, AND WALL PARTITIONS; NO RACEWAY SHALL BE EXPOSED IN INTERIOR SPACES SUCH AS RESIDENT ROOMS. CONCEALED CONDUITS MAY BE EMT. THE MINIMUM Revised: CONDUIT SIZE IS TO BE 3/4" FOR HOME RUN. ALL CONDUITS AND RACEWAYS SHALL BE METAL. _ A-- S. CONDUCTOR: ALL CONDUCTOR WIRE AND CABLE SHALL CONSIST OF 99% CONDUCTIVITY COPPER. ALL CABLES SHALL BE SINGLE CONDUCTOR, 600VOLT, THERMOPLASTIC INSULATION. SUITABLE FOR CONTINUOUS OPERATION AT 75 DEGREES C. CONDUCTOR TEMPERATURE IN BOTH WET AND DRY LOCATIONS. THESE CABLES SHALL BE N.E.G. INSULATION CLASSIFICATION TYPE THWN/THHN. MINIMUM SIZE SHALL BE #12. ALL CONDUCTOR INSTALLATION SHALL BE COLOR CODED MAINTAINING THE INTEGRITY OF THE EXISTING INSTALLATION. COLORED INSULATION SHALL BE USED FOR AWG SIZES X10 AND SMALLER AND APPROVED COLOR TAPES SHALL BE USED FOR AWG SIZES #8 AND LARGER ALL POWER AND CONTROL CIRCUITS SHALL CARRY EQUIPMENT GROUNDING CONDUCTOR SIZED PER NEC 250 -95. 9. THE NATURE OF THIS TYPE OF CONSTRUCTION POSES SPECIAL PROBLEMS FOR THE DESIGN ENGINEERS AS WELL AS THE CONTRACTOR. EVERY EFFORT HAS BEEN MADE BY THE ENGINEERS TO SHOW AND VERIFY WHERE POSSIBLE. THE LOCATION OF THE EXISTING ELECTRICAL SYSTEMS. THE MAJOR PORTION OF THE ELECTRICAL SYSTEMS ARE AS SHOWN ON THE Client DRAWINGS. HOWEVER MINOR DEVIATIONS MAY BECOME EVIDENT AS THE JOB PROGRESSES. NO ADVANTAGE IS TO BETAKEN BY THE CONTRACTOR BECAUSE THESE MINOR DIFFERENCES. 10. ALL FLOORS, WALLS, AND ROOF PENETRATIONS SHALL BE PROPERLY SEALED -OFF. IF FIRE RATED, AN APPROVED FIRE RETARDANT SEALANT SHALL BE USED. 11. THESE DRAWINGS ARE A GUIDE FOR THE INSTALLATION OF THE RACEWAY SYSTEM AND EQUIPMENT. THEY ARE INTENDED TO SHOW THE GENERAL ARRANGEMENT. DESIGN AND EXTENT OF TNF WORK ANn PARTS v nlu(rRAKARAATfr` TUM r+nKrr©Af --rn© 10