11-293-015PLUMBING NOTES 1. CONTRACTOR SHALL VISIT THE SITE AND THOROUGHLY FAMILIARIZE HIMSELF WITH AND VERIFY ALL EXISTING CONDITIONS AND REPORT ANY DISCREPANCIES TO THE ARCHITECT/ ENGINEER PRIOR COMMENCING WORK. 2. THE CONTRACTOR SHALL COORDINATE THE WORK OF THIS TRADE WITH ALL OTHER TRADES TO AVOID INTERFERENCE WITH THE PROGRESS OF CONSTRUCTION AND REPORT ANY DISCREPANCIES TO THE ARCHITECT/ ENGINEER. 3. REQUIRED INSURANCE SHALL BE PROVIDED BY THIS CONTRACTOR FOR PROTECTION AGAINST PUBLIC LIABILITY AND PROPERTY DAMAGE FOR THE DURATION OF WORK. 4. ALL PERMITS, FEES, INSPECTIONS AND TESTS SHALL BE THE RESPONSIBILITY OF THE PLUMBING CONTRACTOR. 5. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS WITH THE ARCHITECTURAL PLANS. 6. ALL MATERIALS SHALL BE NEW AND OF AN AMERICAN MANUFACTURER, FREE FROM DEFECTS, INDELIBLY MARKED WITH NAME OF MANUFACTURER, WEIGHT AND/ OR CLASS. 7. ALL WORK SHALL BE PERFORMED BY A LICENSED PLUMBING CONTRACTOR IN A FIRST CLASS WORKMANLIKE MANNER. THE COMPLETE SYSTEM SHALL BE FULLY OPERATIVE. 8. VERIFY LOCATION, SIZE AND ELEVATION OF ALL UTILITIES PRIOR TO BEGINNING CONSTRUCTION. ADVISE ARCHITECT/ ENGINEER OF ANY DISCREPANCIES. 9. DRAWINGS ARE DIAGRAMMATIC. DO NOT SCALE DRAWINGS FOR THE EXACT LOCATION OF FIXTURES AND PIPING. 10. FIRESTOPS SHALL BE PROVIDED AT ALL PLUMBING FIXTURES. 11. PROVIDE DIELECTRIC UNIONS WHERE DISSIMILAR METALS ARE JOINED. 12. ESCUTCHEONS SHALL BE CHROME PLATED BRASS WITH LOCKING SCREWS WHERE PIPES PASS THROUGH FINISHED WALLS. 13. ALL 3" OR BIGGER HORIZONTAL BRANCHES, SEWER AND DRAIN LINES SHALL BE SLOPED A MINIMUM OF 1/8 IN /FT. AND 2" OR SMALLER SHALL BE SLOPPED AT 1/4 IN /FT. UNLESS OTHERWISE INDICATED ON PLANS. 18. CONTRACTOR SHALL GUARANTEE ALL WORK FREE FROM DEFECTS OF WORKMANSHIP AND/ OR MATERIALS FOR A PERIOD OF ONE YEAR FROM DATE OF ACCEPTANCE. 19. ALL HOT WATER PIPES SHALL BE INSULATED. WITH 1" THICK GLASS FIBER MOLDED INSULATION. WITH PRE -SIZED FACTORY APPLIED FRJ JACKET OF GLASS CLOTH WITH LONGITUDINAL LAP AND BUTT JOINT STRIPS WITH SELF SEALING ADHESIVE. 20. ALL A/C CONDENSATE DRAIN LINES SHALL BE INSULATED WITH 1/2' ARMAFLEX PIPE INSULATION.SEAL ALL SEAMS WITH INSULATION MANUFACTURER'S SOLVENT. NO TAPES ARE ALLOWED. 21. INSULATE ALL HANDICAPPED LAVATORIES, EXPOSED DRAINS AND WATER PIPING TO PROTECT AGAINST BURNING AND OR CUSHION IMPACT. PIPING AS UNDER LAVATORIES PER FPC 404.6.4 USE HANDI LAV- GUARD' INSULATION KIT OR APPROVED EQUAL COORDINATE COLOR WITH ARCHITECT. 22. ALL PLUMBING WORK SHALL BE DONE IN ACCORDANCE WITH THE FLORIDA BUILDING CODE PLUMBING 2007. 23. PIPING MATERIALS SANITARY, GREASE /OIL WASTE, STORM AND CONDENSATE DRAINAGE: PVC: PVC, SCHEDULE 40 SWEAT PROOFING: SWEAT PROOF HORIZONTAL STORM DRAINAGE PIPING BETWEEN DRAIN AND VERTICAL LEADER RUNNING IN CONDITIONED AIR SPACE OR PLENUMS WITH 1/2" THICK GLASS FIBER SECTIONAL PIPE COVERING WITH FLAME RETARDANT VAPOR BARRIER JACKET. COPPER TUBING: (2' AND SMALLER) TYPE "K" OR" L': SEAMLESS HARD DRAWN OR ANNEALED, ASTM B88. TYPE DWV: SEAMLESS HARD DRAWN, ASTM 8306. DOMESTIC WATER SUPPLY PIPING: A. ABOVE GROUND: COPPER TUBING TYPE "L" WITH BRONZE OR WROUGHT COPPER SOLDER JOINT FITTINGS WITH 95/5 SOLDER. 14. EVERY FIXTURE CONNECTED TO THE DRAINAGE SYSTEM SHALL BE 24. PROVIDE WATER HAMMER ARRESTORS FOR QUICK CLOSING VALVES AS PER FPC 604.9 EQUIPPED WITH A WATER SEAL TRAP. 25. PROVIDE PIPE LABELING SYSTEM FOR ALL UNDERGROUND PIPES UNDER SLAB 15. ALL EXPOSED PIPING WITHIN TOILET ROOMS SHALL BE CHROME - PLATED. 16. PLUMBING FIXTURES SHALL COMPLY WITH WATER CONSUMPTION CONTRACTOR TABLE 604.4 CONNECT D WASTE TO EQUIPME REQUIRED FURNISHED BY OTHERS AS FOR COMPLETE OPERATI01 PLUMBING LEGEND SYMBOL DESCRIPTION - --- SANITARY WASTE PIPE (SAN) SANITARY VENT PIPE SYM. DOMESTIC COLD WATER HOT WATER •• REMARKS HOT WATER FD FLOOR DRAIN W/ 1/2' TRAP RESEAL -191 FCO FLOOR CLEAN OUT -- it WCO WALL CLEAN OUT 1r-- am- 'P" TRAP 3+ HB HOSE BIBB W/VAC. BREAKER F.U. FIXTURE UNIT C==IWH -# INSTANT WATER HEATER # X TP TRAP PRIMER Y.T.R. VENT THROUGH ROOF A.F.F. ABOVE FINISHED FLOOR AG ABOVE GROUND UG UNDERGROUND FD FLOOR DRAIN FIXTURE CONNECTION SCHEDULE SANITARY SYM. FIX CW HW REMARKS WASTE HLAY HANDICAP 2" 1/2' _ VITREOUS CHINA WALL MOUNTED, ONE HOLE. 0.5 GPM FLOW CONTROL AERATOR, INFRA -RED SENSOR LAVATORY ACTIVATED FAUCET. BASICS OF DESIGN: TOTO LT307 WITH TEL3GSIO #CP FAUCET. HANDICAP VITREOUS CHINA, ELONGATED BOWL, SEAT LESS OPEN, 1.6GPF, WALL MOUNTED, ADA COMPLIANT. BATTERY HWC WATER 4" in - POWERED. BASIS OF DESIGN: AMERICAN STANDARD AFWALL 3351.160 WITH SLOAN OPTIMA 111 FLUSH CLOSET VALVE. FD FLOOR DRAIN 2" - - FLOOR DRAIN WITH 1/2" GRAVITY TRAP PRIMER CONNECTION. HB HOSE BIBBS - 1 3/4' - CHICAGO FAUCET MODEL 1387 -RCF VANDAL RESISTANT ;. 1. ALL PLUMBING FIXTURES FURNISHED ANPINSTALLED BY : t O• red de' ,.,.rchitecture interiors planning CONSULTANTz A &B I .• Consulting MEP g 7205 NW 19th Street, Suite 501 Florida Sae-. Fatemian CA !W • • ZOILA MORALES, P.E. #64981 ELECTRICAL • RAUL S. MASTRAPA, P.E. #40182 MECHANICAL Sheet Information Date 03-18-11 •a 08024/1574-02 Scale ASSHOWN M1