Loading...
11-249-001L.NSURE TIC New Hds. AddE N FIRE SPRINKLER PLAN SCALE: 3/16"=l'-O" SYMBOLS LEGEND EXISTING PIPE - - - -- NEW PIPE NEW HANGER PIPE TO BE DEMO. NEW. SEMI - RECESSED SPKR. HEAD. N Q• EXISTING 1" OUT. E • EXISTING PD. HEAD TO REMAIN E 1S" LVINMA GENERAL NOTES EXISTING MEDICAL / OFFICE AREA WITH BAR JOIST CONSTRUCTION CEILING FULLY SPRINKLERED SIMPLEXGRINNELL TO ADD NEW FIRE SPRINKLERS ACCORDING TO NEW LAYOUT. NEW LAYOUT TO BE DESIGNED AS LIGHT HAZARD. WITH A MAXIMUM COVERAGE OF: 225 SQ.FT. PER FIRE SPRINKLER. ALL ARMOVERS TO BE XL- ALLIED PIPE WITH CAST IRON FITTINGS. ALL WORK SHALL BE IN ACCORDANCE WITH NFPA -13 (2002). HANGER LUCATION DETAIL APPROVALS ❑ OUT X IN ❑ OUT IN ❑ OUT IN ❑ OUT IN PIPE SIZE A LIN HYDRAULIC DESIGN DATA DESIGN DENSITY DESIGN DES. AREA INSIDE OUTSIDE # OF TOTAL SYSTEM REQUIREMENTS AREA HAZARD CLASSIFICATION GPM/SQFT AREA LENGTH HOSE HOSE SPRINIQERS SQ. FT. FACTOR ALLOW. ALLOW. FLOWING GPM PSI AT NODE C 1' 3' -0' MAX. 12' -0' MAX, 3' MIN. lid' 4' -0' MAX. 12' -0' MAX. 3' MIN, W -8' 5' -0' MAX. 15' -0' MAX. 3' MIN. A BN HANGER STEEL PIPE SPRINKLER HEAD C N MAXIMUM HANGER SPACING FEW THREADED LIGHTWALL STEEL PIPE IS 12' -0' F17R ALL PIPE SIZES I HANGER LOCATION DETAIL FP -1 2 Q 3 O � ** ARMOVERS GREATER THAN 24- IN LENGTH SHALL BE SUPPORTED BY A HANGER OR STRAP. SCHEDULE 1. EXISTING BRANCHUNE. 2. 1- ARMOVER.* 3. 1- DROP 4. NEW FIRE SPRINKLER HAD. 3 FIRE SPRINKLER DETAIL FP -1 SCOPE OF WORK - REPLACE EXISTING O-D MODEL SPRINKLER DUE TO MISSING ESCUTCHEON IN EXITING CLOSET. - ADD A NEW SPRINKLER HEAD IN EXISTING CLOSET. - ADD TWO NEW SPRINKLER HEADS IN FILING ROOM. - WORK ONLY TO BE DONE IN THE AREAS MENTIONED ABOVE EXISTING REMAIN I NGMEDICAL OFFICE FULLY SPRINKLERED NOT IN CONTRACT. CW 7')nA C4 / C.. a n_ KEY PLAN N.T.S. RESPONSIBILITY APPROVALS ❑ OUT X IN ❑ OUT IN ❑ OUT IN ❑ OUT IN SYSTEM INFO SYS. #. SYS. TYPE VA DIA rn. SPK SYS. AREA SYMBOLS *13" PIPE¢TO BOTTOM OFDECK 12-4 PIPE TO FINISHED FLOOR � WATER FLOW SWITCH ❑T TAMPER SWITCH �p HYDRAULIC REFERENCE POINT #1 BRANCHLINE /MAIN LABEL A4 WELDED PIPE LABEL -D CAP (THRDORGRVD) ® SYSTEM RISER -6- COUPLING (THRD OR GRVD) -+- FLANGED CONNECTION - - 2 -WAY EARTHQUAKE BRACE + 4WAY EARTHQUAKE BRACE PIPE HANGER IMPORTANT NOTICE TO USER BY ACCEPTING OR USING THIS DRAWING AND /OR THE INFORMATION CONTAINED HEREIN, THE USER AGREES TO THE FOLLOWING TERMS AND CONDITIONS: THE ELECTRONIC INFORMATION IN THE DRAWING MAY BE SUBJECT TO INTENTIONAL OR UNINTENTIONAL ALTERATION. ANY USE, REUSE, COPYING MODIFICATION OR ALTERATION OF THE INFORMATION CONTAINED HEREIN SHALL BE AT THE SOLE RISK OF THE USER. THIS INFORMATION MAY NOT BE SOLD OR TRANSFERRED TO ANY THIRD PARTY, USED ON OTHER PROJECTS OR ADDITIONS TO THE PROJECT FOR WHICH IT WAS PREPARED, OR USED FOR COMPLETION OF THIS PROJECT BY ANY THIRD PARTY. SIMPLEXGRINNELL DISCLAIMS ALL LIABILITY FOR THE USE OR REUSE OF ALTERED FILES BY THE USER OR ANY THIRD PARTY AND SUCH USE WILL BE A USER'S SOLE RISK USER SHALL, TO THE FULLEST EXTENT PERMITTED BY LAW, DEFEND, INDEMNIFY, AND HOLD SIMPLEXGRINNELL HARMLESS FROM ANY AND ALL CLAIMS FOR LOSS, DAMAGE OR INJURY ARISING DIRECTLY OR INDIRECTLY THEREFROM. IN LOCALITIES SUBJECT TO FREEZING CONDITIONS, THE OWNER MUST MAINTAIN HEAT THROUGHOUT WET PIPE SPRINKLER SYSTEMS AREAS, AND IN ENCLOSURES WHERE DRY PIPE, DELUGE OR OTHER VALVES CONTROLLING WATER SUPPLIES TO SPRINKLER SYSTEMS ARE LOCATED. ©2009 SIMPLEXGRINNELL LP -ALL RIGHTS RESERVED HYDRAULIC DESIGN DATA DESIGN DENSITY DESIGN DES. AREA INSIDE OUTSIDE # OF TOTAL SYSTEM REQUIREMENTS AREA HAZARD CLASSIFICATION GPM/SQFT AREA LENGTH HOSE HOSE SPRINIQERS SQ. FT. FACTOR ALLOW. ALLOW. FLOWING GPM PSI AT NODE SPRINKLERS / NOZZLES SYM. QTY. ORIENTATION SPK FINISH TEMP. K -FACT NPT SIN MANUFACT. MODEL # RESPONSE • • O 4 Pendent Chrome 155 5.6 1/2 -3251 Tyco TY -B Standard WORKS SG DESCRIPTION OF WORK Adding & Relocating Fire S kF. HdS. REVISIONS NO. DATE BY REVISION DESCRIPTION 0 02 -18 -11 FOR AHJ APPROVAL ❑ I WATER SUPPLY INFO: STATIC PRESSURE PSI - RESIDUAL PRESSURE: PSI WITH GPM FLOWING TEST LOCATION: - BY: TEST DATE: 4 TOTAL SPRINKLERS / NOZZLES THIS SHEET ✓5/ V D SARN!Ir/ g4.YP . HANGER DETAIL 'r© O a FIRE SPRINKLER DETAIL FP -1 SW 72nd St. / Sunset Dr. Semi - Recessed All( SCALE: AS NOTED DRAWN BY: JAR CHECKED BY: B.GL CONTRACT WITH: South Miami Hoop. CONTRACT NO: 000000000 DATE: REV. #: 02 -18 -11 COMPONENTS I. TOP BEAM aAP 2 GALV. HANGER RNG 3. 3/e' AYR FOR PIPE 1' -4'. 1/2' ATR FOR PIPE C -B'. SCHEDULE 1. NEW MECH. TEE. 2. EXISTING BRANCH LINE. 3. NEW 1 *x0 -2- NIP 4. NEW 1- ARMOVER. 5. NEW 1- DROP. 6. NEW FIRE SPRINKLER HEAD. MIA ARPROVED MI -DADE COUNTY FIRE DEPARTMENT BLDG. PERMIT FIRE ALARM FIRE SUPPRESSION :7' WATER MAIN EXT. DATE: S/3/2011 4 a �1 ri- } A Simp/exGrinneM BE SAFE. A Tyco International Company LOCAL OFFICE: 10550 Commerce Parkway Miramar, FL 33025 JOB NAME AND LOCATION: South Miami Hospital BLDG. 6250 - 2nd. FL. 6200 SW 73rd St. t7V SHEET DESCRIPTION: Miami, FI. 43 LATEST REV. DESCRIPTION: DRAWING NO. FP -1 of 1 K` R6 1 • ree� sill�k'f~ ate'