11-233-018j, 811 Ponce De Leon Blvd. / i i / l http: / /www.s- garchitects corn i http:F/www. Heery.com �y E13 0005176 GENERAL SYSTEMS PLAN NOTES 1. REFER TO ARCHITECTURAL ELEVATIONS FOR FINAL MOUNTING HEIGHTS OF ALL DEVICES. UNLESS NOTED OTHERWISE, ARCHITECTURAL ELEVATIONS SHALL DICTATE MOUNTING HEIGHTS OF ALL FIXTURES. 2. VERIFY AND COORDINATE EXACT ELECTRICAL REQUIREMENTS OF ALL EQUIPMENT WITH MANUFACTURER'S RECOMMENDATIONS PRIOR TO INSTALLATION OF EQUIPMENT. 3. FIRE ALARM CONTRACTOR SHALL FULLY TEST ALL INITIATING DEVICES WITHIN THE SMOKE COMPARTMENT TO ENSURE THAT ALL DEVICES ARE CORRECTLY ANNUNCIATING THE CORRECT SMOKE COMPARTMENT IDENTIFICATION, AS SHOWN ON THE LIFE SAFETY PLAN, CONTRACTOR SHALL CORRECT ANY AND ALL DISCREPANCIES FOUND DURING SAID TESTING PROCEDURE. 4. CONTRACTOR SHALL PROVIDE LOCAL DISCONNECTING MEANS (I.E. TOGGLE SWITCH, KEY SWITCH) FOR ALL HARDWIRED CONNECTIONS, INCLUDING JUNCTION BOX CONNECTIONS, REGARDLESS IF IT IS SHOWN ON THE PLANS OR NOT. 1 NL2 -2 2 I 2 2 I 811 Ponce De Leon Blvd. it i FAX: (305) 445 -2374 I POWER PLAN NOTES OCONTRACTOR SHALL DISCONNECT EXISTING DEVICE AT LOCATION AS SHOWN ON THE DEMOLITION PLANS AND RELOCATE TO NEW LOCATION SHOWN ON THIS PLAN. EXTEND CONDUIT AND WIRE FROM EXISTING LOCATION TO NEW LOCATION, PROVIDE NEW COVERPLATE FOR EACH OUTLET AND REVISE PANEL SCHEDULES TO SHOW NEW LOCATION. O EXISTING FIRE ALARM DEVICES TO BE RELOCATED. ONEW FIRE ALARM DEVICE, CONDTRACTOR SHALL PROVIDE NEW FIRE ALARM DEVICE AND NEW CONDUIT AND WIRING FROM EXISTING NAC CIRCUIT. PARTIAL FIRST FLOOR PLAN - POWER AND SYSTEMS A -1.0 SCALE: 1/4" = V -0" a� � r � KEY PLAN � AHCA► Project ID - Submission no. 164 -C101 f' Heery International Inc. 811 Ponce De Leon Blvd. Coral Gables, PL 33134 TEL: (305) 441 -1556 FAX: (305) 445 -2374 http: / /www.s- garchitects corn http:F/www. Heery.com �y E13 0005176 s Project Number 1022801 I � C T - d l co CN '�.. cf) LO CU CU ` V CD 'I N C Z: , CP CC{ Q 00 CD c O O Ci Cp C, F- CA'�"� ono a c: o LO O NC% ° U G � POWER PLAN NOTES OCONTRACTOR SHALL DISCONNECT EXISTING DEVICE AT LOCATION AS SHOWN ON THE DEMOLITION PLANS AND RELOCATE TO NEW LOCATION SHOWN ON THIS PLAN. EXTEND CONDUIT AND WIRE FROM EXISTING LOCATION TO NEW LOCATION, PROVIDE NEW COVERPLATE FOR EACH OUTLET AND REVISE PANEL SCHEDULES TO SHOW NEW LOCATION. O EXISTING FIRE ALARM DEVICES TO BE RELOCATED. ONEW FIRE ALARM DEVICE, CONDTRACTOR SHALL PROVIDE NEW FIRE ALARM DEVICE AND NEW CONDUIT AND WIRING FROM EXISTING NAC CIRCUIT. PARTIAL FIRST FLOOR PLAN - POWER AND SYSTEMS A -1.0 SCALE: 1/4" = V -0" a� � r � KEY PLAN � AHCA► Project ID - Submission no. 164 -C101 f' Heery International Inc. 811 Ponce De Leon Blvd. Coral Gables, PL 33134 TEL: (305) 441 -1556 FAX: (305) 445 -2374 http: / /www.s- garchitects corn http:F/www. Heery.com AA 0002293 E13 0005176 s Project Number 1022801 I � C T - d l co CN '�.. cf) LO CU CU ` V CD 'I N C Z: , CP CC{ Q 00 CD c O O Ci Cp C, F- CA'�"� ono a c: o LO O NC% ° U G � O 117 `' 37 hod CD CD O m wI LLJ (o r co co J C� G cQ C O W Q D C\1 dal 1� l � CD • Z 0 0 _ _ Q N' LL1 2 I m z r iD O Revisions _ Date DAHCA Comments 2/23/11 i Seal: James Ferris, P.E. Florida License #65156 f ' Seal Checked By TLC Drawn My TLC Date: 02. -18 -2011 Issue: 02 -18 -2011 Sheet Index: PARTIAL 1ST FLOOR PLAN POWER & SYSTEMS Sheet Number: 82.0 i J u f r r