11-233-0101; SYMBOL '�I IL�I ITIII LAI L11 f v 0 FDA- L LN L1 Ay SYMBOL CWS CWR CHWS CHWR CD -_--- CR PC HWR HWS HPS MPS LPS HPR MPR LPR RL RS DESCRIPTION - CEILING DIFFUSER, ROUND NECK (CEILING DIFFUSERS ARE 4 -WAY THROW UND) -ROUND DIFFUSER CEILING RETURN CEILING EXHAUST CEILING DIFFUSER, RECTANGULAR OR SQUARE NECK (CEILING DIFFUSERS ARE 4 -WAY THROW UNO) - SUPPLY REGISTER OR GRILLE (VERTICAL MOUNT, SIDEWALL) - RETURN /EXHAUST REGISTER OR GRILLE (VERTICAL MOUNT, SIDEWALL) - REVISION REFERENCE - DETAIL REFERENCE: TOP - DETAIL #; BOTTOM - DRAWING# SHOWN ON - THERMOSTAT /TEMPERATURE SENSOR - HUMIDiSTAT /HUMIDITY SENSOR -DUCT SMOKE DETECTOR - CONNECT TO EXISTING - MOTORIZED CQNTP,OL DAMPER - TEMPERATURE SENSOR - PRESSURE SENSOR - BACKDRAFT DAMPER - NEUTRAL RELATIVE PRESSURE - POSITIVE RELATIVE PRESSURE - NEGATIVE RELATIVE PRESSURE -SHEET NOTE CALLOUT -SHEET NOTE CALLOUT -SHEET NOTE CALLOUT - CEILING MOUNTED ACCESS DOOR DESCRIPTION- - CONDENSER WATER SUPPLY - CONDENSER WATER RETURN - CHILLED WATER SUPPLY - CHILLED WATER RETURN - CONDENSATE - CONDENSATE RETURN - PUMPED CONDENSATE -HOT WATER RETURN -HOT WATER SUPPLY -HIGH PRESSURE STEAM SUPPLY - MEDIUM PRESSURE STEAM SUPPLY -LOW PRESSURE STEAM SUPPLY -HIGH PRESSURE STEAM RETURN - MEDIUM PRESSURE STEAM RETURN -LOW PRESSURE STEAM RETURN - REFRIGERANT LIQUID - REFRIGERANT SUCTION HVAC SYMBOL LEGEND SYMBOL �SC;R Ir'] Eluhv I e ..4 r_--f I � II M F - -- - 24x12 - - - -- } r-- -------- - - - - -� IvA DOWN ;'F� ,'';,;,1 i 1__. -FIRE DAMPER (WITH ACCESS PANEL) (WITH ACCESS PANEL) - EXISTING FIRE DAMPER TO REMAIN REMAIN -SOUND ATTENUATOR -MOTOR OPERATED CONTROL DAMPER (MOD) JI1 W VL SI.iRIN(, „TA]10 - MANUAL BALANCING DAMPER -DOOR GRILLE - ACCESS DOORS, VERTICAL. OR HORIZONTAL - STAINLESS STEEL DUCTWORK LAT UVA: P;J(l,' N %>l DUCTJvO(� ,. 1R`, MEN: i!TIV SiL)E SHO'1dN - EXISTING DUCTWORK TO REMAIN EXISTING DUC WORK TO BE REMOVED iii L O h�. ��'i1.�L 1V/ PRESSI,.kr_ PP[ 1 ") Di, CT EL :)O , I-XH. US -DUCT ELBOW, NFGAIIVE PRESSURE, RETURN -DUCT ELBOW UP THROUGH ROOF OR SLAB ABOVE - RECTANGULAR DUCT SECTION UP, POSITIVE PRESSURE, SUPPLY OR OUTSIDE AIR `''EC TAIGU! AR SL ,LION J!" NE,'A IVF PR' S` URE R`.TURN - R'CTAN,,U1AR DL(_" SF_TION UP, EXHAU` - ROUND DUCT SEC-!ION lJ, FLAT OVAL DUCT SECTION UP . EXHAUST DUCT UP THROUGH SLAB W/ E'AN ON ROOF ABOVE - EXHAUST FAN ON ROOF W/ DUCT DOWN THROUGH ROOF HVAC PIPING SYMBOL LEGEND SYMBOL _ DESCRIPTION -FLOW DIRECTION -GATE VALVE -BALL VALVE - CALIBRATING BALANCING VALVE - BUTTERFLY VALVE -GAS COCK - --II -UNION - STRAINER - CONTROL VALVE - SOLENOID VALVE - -D : -PSI REG. ' -CHECK VALVE -FLOW SWITCH -SLOPE DIRECTION (DOWN) -FLEX CONNECTION - O.S.&Y. GATE VALVE -STEAM TRAP n HREE -WAY CONTROL VALVE Y i - THERMOMETER -TWO -WAY CHECK VALVE - RELIEF VALVE I -O -VALVE ON RISER SyV,3t:'. ==c IL J I �X I �II1��iIl� - - .._-...1 UP Lw XXX�XXXXX�XXXZXZXXXZXXX I F �_ D a �T 3YMB0L 1 E I C - e �D D )E A NOTE: SOME SYMBOLS SHOWN ON THIS LEGEND MAY NOT PERTAIN TO THIS PROJECT DESCRIPTION TERMINAL UNIT, VARIABLE /CONSTANT AIR VOLUME - TERMINAL UNIT, VARIABLE /CONSTANT AIR VOLUME WITH ELECTRIC HEAT - TERMINAL UNIT, VARIABLE /CONSTANT AIR VOLUME, FAN POWERED - TERMINAL UNIT, VARIABLE /CONSTANT AIR VOLUME, FAN POWERED, WITH ELECTRIC HEAT - ELECTRIC DUCT HEATER (W/ PANEL CLEARANCE) - HYDRONIC REHEAT COIL - INLINE CENTRIFUGAL FAN - PACKAGED TERMINAL AIR CONDITIONER (PTAC) - CHANGE OF ELEVATION - FLEXIBLE DUCT - TRANSITION, CONCENTRIC - TRANSITION, ECCENTRIC - TRANSITION, SQUARE TO ROUND - SQUARE THROAT ELBOW W /TURNING VANES - RADIUS ELBOW - RECTANGULAR /ROUND BRANCH TAKE -OFF OR ROUND /ROUND BRANCH TAKE -OFF - SQUARE THROAT TEE - RADIUS TEE - RECTANGLE -TO - ROUND TAKE -OFF - STANDARD BRANCH TAKE -OFF - SPIN -IN TAKE -OFF DESCRIPTION - P -TRAP - MANUAL VENT - PRESSURE GAUGE -FLOW METER -WATER METER - INLINE PUMP - INLINE PUMP -CAP - CONNECTION, BOTTOM - CONNECTION, TOP - COUPLING -ELBOW, 90' - ELBOW, 45' - ELBOW, TURNED DOWN - ELBOW, TURNED UP -TEE, OUTLET DOWN -TEE, OUTLET UP -45' PIPE RISE (R) / DROP (D) -PIPE ANCHORS - CONCENTRIC REDUCER - ECCENTRIC REDUCER SYMBOL HVAC ABBREVIATIONS DESCRIPTION SYMBOL DESCRIPTION AFD - ADJUSTABLE FREQUENCY DRIVE MCA - MINIMUM CIRCUIT AMPS AFF -ABOVE FINISHED FLOOR MOCP - MAXIMUM OVER CURRENT PROTECTION AFR -ABOVE FINISHED ROOF MOD -MOTOR OPERATED CONTROL DAMPER (MOD) AHU -AIR HANDLING UNIT NC -NORMALLY CLOSED AP - ACCESS PANEL NO - NORMALLY OPEN BOP - BOTTOM OF PIPE NTS --NOT TO SCALE BHP -BRAKE HORSEPOWER OA - OUTSIDE AIR BTU - BRITISH THERMAL UNIT OAL - OUTSIDE AIR LOUVER - CENTER LINE PRV -- PRESSURE REDUCING VALVE -CFM (CUBIC FEET PER MINUTE) PRS - PRESSURE REDUCING STATION CD -- CEILING DIFFUSER PSI - POUNDS PER SQUARE INCH CT - COOLING TOWER PSIG - -PSI GAUGE CV CONSTANT AIR VOLUME PTAC - PACKAGED TERMINAL AIR CONDITIONER CFM -CUBIC FEET PER MINUTE PVC - POLYVINYL CHLORIDE PIPE CU - CONDENSING UNIT RA - RETURN AIR DDC - DIRECT DIGITAL CONTROLS RHC - REHEAT COIL DIN -DOWN RHP - ROOFTOP HEAT PUMP EAT - ENTERING AIR TEMPERATURE RPM - REVOLUTIONS PER MINUTE ESP - EXTERNAL STATIC PRESSURE RS /L - REFRIGERANT SUCTION do LIQUID LINES EWT - ENTERING WATER TEMPERATURE RTU - ROOFTOP AIR HANDLING UNIT FCU -FAN COIL UNIT SA - SUPPLY AIR FD -FIRE DAMPER SP - STATIC PRESSURE FF -FINAL FILTERS TSP -TOTAL STATIC PRESSURE FLA -FULL LOAD AMPS UNO - UNLESS NOTED OTHERWISE FPM --FEET PER MINUTE V /PH -VOLTS /PHASE GPM - GALLONS PER MINUTE VAV - VARIABLE AIR VOLUME KW - KILOWATT VFD - VARIABLE FREQUENCY DRIVE EAT - LEAVING AIR TEMPERATURE p P - CHANGE IN PRESSURE LWT - LEAVING WATER TEMPERATURE AT - CHANGE IN TEMPERATURE ED - LINEAR DIFFUSER MBH - THOUSAND BTUs PER HOUR HVAC EQUIPMENT TAGS TAG =A2 \-CFM AHU NUMBER AHU -1 -AIR DISTRIBUTION DEVICE -AIR HANDLING UNIT AHU NUMBER � �COIL NUMBER RHC -1 -1 - REHEAT COIL VARIABLE /CONSTANT AIR VOLUME TERMINAL UNITS TERMINAL UNIT TYPE AHU NUMBER VTU - VARIABLE TERMINAL UNIT CTU - CONSTANT TERMINAL UNIT TERMINAL NUMBER PTU - PARALLEL TERMINAL UNIT VTU -1 -1 STU - SERIES TERMINAL UNIT GENERAL NOTES 1. CONNECTION TO EQUIPMENT SHALL BE VERIFIED WITH MANUFACTURER'S CERTIFIED DRAWINGS. TRANSITIONS TO ALL EQUIPMENT SHALL BE VERIFIED AND PROVIDED FOR EQUIPMENT FURNISHED. 2, DIMENSIONS SHALL BE FIELD - VERIFIED AND COORDINATED PRIOR TO PROCUREMENT OR FABRICATION. COORDINATE THE WORK WITH OTHER TRADES INVOLVED. FIELD MODIFICATIONS SUCH AS OFFSETS IN PIPING OR DUCTWORK (INCLUDING DIVIDED DUCTWORK) NEEDED DUE TO OBSTRUCTIONS OR INTERFERENCES SHALL BE PROVIDED AT NO ADDITIONAL COST. FOR PROJECTS INVOLVING RENOVATION, COORDINATE NEW WORK WITH EXISTING ELEMENTS SUCH AS THE BUILDING STRUCTURE AND ARCHITECTURAL FEATURES, SPRINKLER PIPING, LIGHTS, PLUMBING, AND ELECTRICAL CONDUIT. 3. DUCT CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF THE SMACNA HVAC DUCT CONSTRUCTION STANDARD. 4. SEE SPECIFICATIONS FOR GAUGES, THICKNESS, BRACING, REQUIREMENTS, ETC., OF DUCTWORK. 5. PROVIDE AIR TURNING VANES IN ALL 90 DEGREE RECTANGULAR DUCT ELBOWS. 6. DUCT SIZES AND ALL OPENINGS THROUGH BUILDING CONSTRUCTION SHALL SUIT EQUIPMENT FURNISHED. 7. COORDINATE DIFFUSER, GRILLE AND REGISTER LOCATIONS WITH ARCHITECTURAL REFLECTED CEILING PLANS AND EQUIPMENT OF ALL TRADES. a. LOCATE THERMOSTATS, TEMPERATURE SENSORS, HUMIDISTATS, AND HUMIDITY SENSORS AT 48" ABOVE FINISHED FLOOR UNLESS NOTED OTHERWISE. COORDINATE LOCATIONS WITH OTHER EQUIPMENT, FURNITURE, AND DOOR SWINGS, 9. ALL EQUIPMENT, DUCTWORK, ETC., SHALL BE SUPPORTED AS DETAILED AND /OR SPECIFIED. PROVIDE ADDITIONAL_ SUPPORTS AS REQUIRED TO PROVIDE A VIBRATION -FREE, RIGID INSTALLATION. 10. ALL DUCT SIZES SHOWN ARE INSIDE CLEAR DIMENSIONS. 11. DAMPERS AND INSIDES OF DUCTS VISIBLE THROUGH GRILLES, REGISTERS AND DIFFUSERS SHALL BE PAINTED FLAT BLACK. 12. REFER TO TYPICAL DETAILS FOR PIPING AND INSTALLATION OF EQUIPMENT. 13. TRAPPED CONDENSATE DRAINS FROM ALL MECHANICAL EQUIPMENT SHALL BE PROVIDED FOR PROPER DRAINAGE TO SUIT EQUIPMENT FURNISHED. 14. ACCESS PANELS IN DUCTWORK AND CEILINGS SHALL BE PROVIDED WHERE REQUIRED FOR OPERATION, BALANCING OR MAINTENANCE OF ALL MECHANICAL EQUIPMENT, 15. ALL DUCTWORK AND PIPING IS SHOWN SCHEMATICALLY. PROVIDE ALL TRANSITIONS, TURNING VANES, ELBOWS, FITTINGS, ETC., TO ALLOW SMOOTH FLOWS. ALL SPLIT DUCT FITTINGS SHALL TRANSITION TO FULL SIZE OF THE SUM OF BOTH BRANCHES, UPSTREAM OF SPLIT. 16. PROVIDE CONCRETE HOUSEKEEPING PAD UNDER ALL FLOOR- MOUNTED EQUIPMENT. REFER TO SPECIFICATIONS FOR DETAILED REQUIREMENTS. 17, VERIFY FINISH WITH ARCHITECT PRIOR TO PURCHASING GRILLES, REGISTERS, DIFFUSERS, LOUVERS AND OTHER AIR DISTRIBUTION DEVICES. 18. PROVIDE FLEXIBLE DUCT CONNECTIONS ON ALL DUCTWORK CONNECTING TO EACH FAN, AIR HANDLING UNITS, AND FAN COIL UNITS. 19. PROVIDE TRANSITIONS AT DIFFUSER NECKS AS REQUIRED TO MATCH SIZES OF FLEX DUCTS TO BE CONNECTED. 20. INTERRUPTIONS TO EXISTING SERVICES SHALL BE SCHEDULED FOR TIMES OTHER THAN NORMAL OPERATING HOURS (SUCH AS NIGHTS AND WEEKENDS). SUCH INTERRUPTIONS TO SERVICES SHALL NOT BE MADE WITHOUT THE PRIOR WRITTEN CONSENT OF THE OWNER'S REPRESENTATIVE AND PROPER COORDINATION WITH OTHER TRADES. PRE WORK SHALL BE PERFORMED TO MAKE THE SHUTDOWN PERIOD AS BRIEF AS POSSIBLE. 21. ALL EQUIPMENT, DUCTWORK, ETC., TO BE REMOVED SHALL REMAIN PROPERTY OF THE OWNER OR DISPOSED OF LEGALLY, AS DIRECTED BY OWNER. 22. MAINTAIN CLEARANCE OF A MINIMUM OF 6" BETWEEN DUCTWORK, PIPING, EQUIPMENT, ETC., AND ALL FIRE RATED AND FIRE /SMOKE RATED PARTITIONS, TO ALLOW FOR INSPECTIONS OF RATED WALLS. 23. LOCATE ALL OUTSIDE AIR INTAKES A MINIMUM OF 25' -0" CLEAR FROM ALL PLUMBING VENTS AND EXHAUST AIR DISCHARGE LOCATIONS, LOWEST POINT OF EACH OUTSIDE AIR INTAKE ON ROOF SHALL BE A MINIMUM OF 36" ABOVE ROOF. 24. DUCT RUNOUTS TO DIFFUSERS SHALL MATCH THE SIZE OF THE DIFFUSER NECK. 25. WATER PRESSURE DROPS THROUGH COIL CONTROL VALVES SHALL NOT EXCEED 5 PSI. 26. UNLESS OTHERWISE NOTED, ALL EQUIPMENT AND VALVE DRAINS SHALL BE INDEPENDENTLY PIPED FULL SIZE TO THE NEAREST PLUMBING DRAIN, 27. SLEEVE AND SEAL ALL PIPING PENETRATIONS THROUGH BUILDING PARTITIONS. PROVIDE MANUAL AIR VENTS AT ALL HIGH POINTS IN CHILLED WATER AND HOT WATER PIPING, 21. PIPING, DUCTWORK, LEAK PROTECTION APPARATUS, OR OTHER EQUIPMENT FOREIGN TO ELECTRICAL SWITCHBOARDS, PANELBOARDS, DISTRIBUTION BOARDS, OR MOTOR CONTROL CENTERS SHALL NOT BE INSTALLED WITHIN THE REQUIRED SPACE FOR WORKING CLEARANCES OR DEDICATED SPACES OF THE ELECTRICAL EQUIPMENT, EXTENDING IN FRONT OF AND FROM FLOOR TO STRUCTURAL CEILING WITH A WIDTH AND DEPTH OF THE ELECTRICAL EQUIPMENT IN ACCORDANCE WITH NEC- 110.26. HVAC DRAWING INDEX SHEET DESCRIPTION M0.0 HVAC LEGEND, GENERAL NOTES do SHEET INDEX M1.0 PARTIAL 1ST FLOOR DEMO PLAN - HVAC M2.0 PARTIAL 1ST FLOOR PLAN -HVAC M3.0 DETAILS AND SCHEDULES HVAC M4.0 SPECIFICATIONS - HVAC is �1. ISSUED Yes Yes Yes Yes AI�CA Project iD - Submission no. 16� -OCl1 Issue: I 02 -18 -2011 0 C W