Loading...
11-233-005REELECTED CEILING PLAN A -3.0 J I SCALE: 1/4" = 1' -0" M04, [A FLOOR PLAN LEGEND GENERAL NOTES (RCP) RELOCATED 2 X 4 FLUORESCENT TEMPORARY CONSTRUCTION PER ICRA CLASS III SEAL ENTIRE PERIMETER PHYSICAL THERAPY DEPARTMENT SHALL NOT BE IN USE DURING RELOCATED 2 X 4 y:........ ;..<..° 1 O R FLUORESCENT FIXTURE. R FIXTURE ON EMERGENCY, REFER TO WITH DUCT TAPE. CONSTRUCTION. ELECTRICAL DRAWINGS. O G.C. SHALL PROVIDE A TEMPORARY CONSTRUCTION WALL AND DOOR 10 MATERIAL AR OUTSIDE SERVE AS R OF THIS STAGGING AREA SHALL FOR G.C. O GC TO BE EXISTING 2 X 4 FLUORESCENT (AS SHOWN IN PLANS) DURING THE ENTIRE DEMOLITION AND CONSTRUCTION OF NEW CORRIDOR (REFER TO DETAILS FOR TYPICAL RESPONSIBLE FOR PROTECTING THE EXISTING CEILING AND GRID AT E FIXTURE. NEW FIRE SPRINKLER HEAD. DUST -PROOF PARTITION ON SHEET A -1.0 ). ALL TIMES. ANY DAMAGED CEILING TILES OR GRIDS SHALL BE REPLACED BY THE GC AS PART OF HIS SCOPE. NEW 2 X 2 LAY -IN TYPE FLUORESCENT FIXTURE NEW EMERGENCY RECESSED FLUORESCENT LIGHT FIXTURE. NEW SUPPLY AIR DIFFUSER NEW RETURN AIR 2 X 2 CEILING MOUNTED SMOKE DETECTOR. NEW 2 X 2 LAY -IN NOTE: ALL SUSPENDED CEILING SHALL BE INSTALLED ACOUSTICAL CEILING AS PER SRC CHAPTER 29 AND ASTM C635 AND C636. W /GRID, REFER TO FINSHES AND COLOR CEILING HEIGHT TO MATCH ADJACENT PHYSICAL THERAPY DEPARTMENT SELECTIONS ON SHEET UNLESS NOTED OTHERWISE. A -4.0 NEW LIGHT FIXTURES SHALL BE 2'x2' LAY -IN TYPE WITH HANGERS ON ALL FOUR CORNERS. OTEMPORARY CONSTRUCTION SITE DOOR 1 -3/4" THICK SOLID CORE WOOD PAINT GRADE - 3/4 HOUR FIRE RATED WITH SELF CLOSER AND LATCHING HARDWARE. THIS DOOR TO REMAIN CLOSED AND LOCKED AT ALL TIMES TO ELIMINATE THE POSSIBILITY OF ALLOWING PATIENTS TO ACCIDENTALLY ACCESS " AREAS OF CONSTRUCTION ". (4) ANY AND ALL EXISTING EQUIPMENT THAT IS TO BE REMOVED TO MAKE WAY FOR NEW CONSTRUCTION SHALL BE REMOVED CAREFULLY AND RETURNED TO OWNER. OIN THE AREA WHERE DEMOLITION IS BEING PERFORMED AND THE EXISTING WALL IS A SMOKE WALL, ITS INTEGRITY TO DETOUR SMOKE ABOVE THE CEILING SHALL BE MAINTAINED AT ALL TIMES. OG.C. SHALL BE RESPONSIBLE FOR REPLACING ANY CEILING TILES AND GRIDS THAT ARE DAMAGED THROUGHOUT THE COURSE OF CONSTRUCTION. O7 NEW 2'X 2' CEILING GRID AND TILES ( ACT) ( REFER TO SHEET A-4.0). NEW 2' X 2' FLUURESCENT FIXTURE TO MATCHADJACENT " RELOCATED" 2' X 4' FLOORESCENT FIXTURES. 11 NEW CORRIDOR "FINISH CEILING HEIGHT" TO MATCH THE FINISH CEILING HEIGHT OF THE ADJACENT PHYSICAL THERAPY DEPARTMENT'S CEILING. 12 FOR INFORMATION ON EXISTING FIRE SPRINKLER LOCATIONS, REFER TO SHEET FP -1.0. 13 FOR INFORMATION ON EXISTING HVAC LAYOUT, REFER TO SHEET M2.0. 14 LOCATION OF RELOCATED HVAC DIFFUSER, REFER TO MECHANICAL DWG's.. 15 NEW HVAC DIFFUSER, REFER TO MECHANICAL DWG'S., 16 CEILING MOUNTED SMOKE DETECTOR, REFER TO SHEET E2.0 FOR ADDITIONAL LIFE SAFETY EQUIPMENT INFORMATION AND LOCATIONS. I `I Y ^-q "k��, KEY PLAN AHCA Project ID - Submission no. 164 -001 Heery International Inc. 811 Ponce De Leon Blvd. Coral Gables, FL 33134 TEL: (305) 441 -1556 FAX (305) 445 -2374 http://wwvv.s-garchitects.com http: / /www.Heery.cow AA 000223 EM 0005176 Project Number 1022801 L c� Ln Lc c Ca CV c_0 < C-o co CO —1 CY3 J LC ti CD u7 U) L ,7 LL crS ED-) - uJ t- Ci • I ^� •' ccam,. W �A 'Q • a 0 F� Revisions A\ AHCA COMMENTS Seal: r 00 C7 C'7 J IL 2 Q I— O U) W Q 0 Z N Cfl Uj ti U z 0 1z W Z O O U) Date 2/23/11 ROMERTO SEQUEIRA REGISTRATION NO. AR- 0009035 Checked My: E.G. Drawn By: A.A. Date: 12 -08 -2010 Issue: 02 -18 -2011 Sheet Index: REFLECTED CEILING PLAN AND NOTES Sheet Number: A-3.0 U O �E W� oQ q 0 N r p � O n o� W T C O � N N wN r w N U EO Llr� o ZS O o J o_ U rU C w r � J 2 (6 U) �U) Q- w� �U _U) ;C)- �m WQ y r wU o C] w LU zZ>