Loading...
11-215-0143/8" GALVANIZED STEEL, SELF TAPPING EYEBOLT (TOTAL OF 4) ELECTRIC CONDUIT GUIDE ROOFING �- SECURE CURB TO ROOF USING FASTENERS AT 4" O.C. BEFORE APPLYING ROOFING AND INSULATION (IF REQUIRED) REFER TO "CURB ATTACHMENT TO CONCRETE SLAB ROOF" DETAIL ON THIS SHEET. WIRING BY OTHERS DUC i ALL WELDED CONSTRUCTION 1/8" stainless steel cable w/ turnbuckle (see note #2) A PROVIDE RUBBER GASKET SEAL BETWEEN FAN AND m "R" SP GA. SMALL SUPPORT FRAME p 24 LARGE 4" U_ 22 MODEL NUMBER 365VX126 SECURE FAN TO CURB WITH U - NO. 14 S/S SCREWS, 8" O.C. va V Vy JJV ALL AROUND 0 Z w M UP -BLAST SIDE DISCHARGE 4 V V U AREA SERVED - FACTORY FABRICATED KITCHEN V VENTED ROOF CURB 8000 6400 - FLASHING AND COUNTER E.S.P. (INCHES OF WATER) 3 FLASHING INTO ROOFING V V V V V SONES SHEET METAL EXHAUST DUCT TYPICAL KITCHEN HOOD UPBLAST EXHAUST FAN N.T.S. j NOTES: 1. KITCHEN HOOD EXHAUST FAN MUST BE U.L. 762 LISTED WITH HINGED & VENTED ROOF CURB, PER NFPA 96. i 2. FANS SHALL BE SECURED WITH CROSS - CONNECTED CABLES OVER THEM, REGARDLESS OF HEIGHT. SCREWS FOR ALL CURB MOUNTED EQUIPMENT SHALL BE SIZE NO. 14 WITH GASKETED WASHERS, 3. ALL ROOF MOUNTED EQUIPMENT AND ANCHORING /STRAPPING SHALL COMPLY WITH THE WIND DESIGN DATA AS INDICATED ON FBC 2007, 1603.1.4 AND FBC MECHANICAL 2007, 301.12 (3- SECOND GUST, 146 MPH, 1.15 WIND IMPORTANCE, CATEGORY "C" EXPOSURE). SHEET METAL RUNNER TOP AND BOTTOM SINGLE VANE SCHEDULE STEELSTRENGTH "R" SP GA. SMALL 2" 1\2" 24 LARGE 4" 31/4' 22 ' SECURED TO DUCT WITH SHEET METAL SCREWS l" • I ! SHEET METAL SINGLE THICKNESS � TYPICAL FABRICATED SHEET QUARTER ROUND TURNING VANES METAL ELBOW T� SECURE FAN TO CU NO. 14 S/S SCREWS, ALL AROUND PROVIDE RUBBER C SEAL BETWEEN FAP SUPPORT FRAME FACTORY FABRICATE[ CANT STRI SECURE CURB i u nvvr vawm, FASTENERS AT 4" O.C. BEFORE APPLYING ROOFING AND INSULATION (IF REQUIRED) SUPPLY FAN DETAIL N.T.S. HING AND COUNTER HIND INTO ROOFING NOTES: 1. FANS SHALL BE SECURED WITH CROSS - CONNECTED CABLES OVER THEM, REGARDLESS OF HEIGHT. SCREWS FOR ALL CURB MOUNTED EQUIPMENT SHALL BE SIZE NO. 14 WITH GASKETED WASHERS. 2. ALL ROOF MOUNTED EQUIPMENT AND ANCHORING /STRAPPING SHALL COMPLY WITH THE WIND DESIGN DATA AS INDICATED ON FBC 2007, 1603.1.4 AND FBC MECHANICAL 2007, 301.12 (3- SECOND GUST, 146 MPH, 1.15 WIND IMPORTANCE, CATEGORY "C" EXPOSURE). 1 1/2 "x1 1/2" (MIN) ANGLE IRON FRAME INSULATION DUCT a OPERATOR/ACTUATOR BREAKAWAY POINT 1 6' SHEET METAL SINGLE THICKNESS TURNING VANES WITH FLANGED FASTENERS TOP AND BOTTOM I SHEET METAL RUNNER FASTENED TO DUCT WITH SHEET METAL SCREWS l e` VN NOTE: SINGLE THICKNESS TURNING VANES SHOWN. PROVIDE DOUBLE I THICKNESS WHERE SPECIFIED. ¢9 DUC-r TURNING VANE DETAIL i NTS i c 'I PREFABRICATED FAN CURB W /FLANGE. (SEE N, CANT STRIP (BY ROOFER) FAN SCHEDULE FOR ROOF CURB.) ROOFING GALVANIZED ROOF CURB PRESSURE TREATED WOOD BLOCKING ILI ROOF INSULATION SEALING COMPOUND d FUSIBLE ACCESS DOOR—/ 14 "X14" MIN. ZONED AS REQUIRED WALL 1/4" CLEARANCE PER FOOT ALL AROUND r SLEEVE r DUCT CAULKING NEGATOR SPRIN - 6 (MI BOTH SI TT AIR FLOW CAULKING FULL PERIMETER OF DAMPER (TYPICAL BOTH SIDES) COMBINATION FIRE /SMOKE DAMPER DETAIL_ N.T.S. NOTES: 1. DAMPER: "RUSKIN." FSD 60 WIYH 165 F FUSIBLE LINK OR APPROVED EQUIVALENT. 2. INSTALLATION OF THE DAMPER SHALL BE IN STRICT ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS AND UL555S. ROOF 8" as a !" CONCRETE ROOF SYSTEM ' 1/2" DIA. EXPANSION BOLT, WITH 2" EMBEDMENT, 4" O.C. ALL AROUND I. CURB ATTACHMENT TO I CONCRETE SLAB ROOF N.T.S. r, FLASHING TO BE MECHANICALLY FASTENED & SOLDERED TO DUCT ALL AROUND FLASHING & COUNTER FLASHING p ANCHOR TO ROOF DUCTWORK TO SYSTEM HIGH PRESSUF CONNECTION SLAB SLEEV' ACCESIE RECTANGL,.,, OR ROUND DUCT. M STAINLESS STEEL BOLT CARBON STEEL BOLT 2" x 2" x 1/4" STEEL ANGLES W /LENGTH AS REQ'D STEELSTRENGTH STEELSTRENGTH IN TENSION = 5980 LB IN TENSION = 6500 LB STEELSTRENGTH STEELSTRENGTH 2"0 STANDARD PIPE (TYP.) IN SHEAR = 4870 LB IN SHEAR = 3595 LB HILTI EXPANSION ANCHOR KWIK BOLT TZ DETAIL N.T.S. SCREWS SCREWS MAY BE OMITTED IF HANGERLOOPS STRAP HANGERS N.T.S. NOTE: REFER TO SMACNA FOR ADDITIONAL DUCT SUPPORT REQUIREMENTS. -1 1/2" x 1 1/2" x 12 GA. VITH 1/4" BOLTS a0 8" O.C. JP TO 48" DUCT DIMENSION) AND -2 " x 2" x 12 GA. WITH 1/4" ;OLT @a 6" O.C. (ABOVE 48" )UCT DIMENSION) (TYP.) " HIGH CURB COORDINATE OCATION AND DIMENSIONS. J.L. RATED FIRE DAMPER SPRING OPERATED FOR IERTICAL AIR FLOW) BLADE AWAY FROM AIR ;TREAM) NOTE: 1. INSTALL FIRE DAMPERS IN STRICT ACCORDANCE WITH UL 555 AND FBC -M 2007 SECTION 607.2/607.3. 2. FIRE DAMPER MANUFACTURER AND FIRE DAMPER INSTALLATION INSTRUCTIONS SHALL COMPLY WITH FBC -M 2007 SECTION 607.2, 607.3.1.1 AND REQUIREMENTS OF UL 555. TYPICAL CURB DUCT DETAIL HORIZONTAL FIRE DAMPER DETAIL N.T.S. N.T.S. DUCT DEPTH WELDED TO BASE PLATE I 4" x 4" x 1/2" PL. SET IN PITCH PANS. PLACE SUPPORTS SO THAT BEARING PLATES ALWAYS REST ON RIB PORTIONS OF THE ROOF & SECURE TO ROOF WITH LAG SCREWS & EXPANSIONS SHIELDS. SUPPORTS SHALL BE A MAX. OF 4' -0" ON CENTERS. DETAIL OF ROOF DUCT SUPPORT 24" MIN. N.T.S. NOTES: 1. FLASH AND COUNTER FLASH AROUND PIPE SUPPORTS. 2. ALL OUTDOOR STEEL SUPPORT COMPONENTS FOR DUCTS SHALL BE HOT DIP GALVANIZED AFTER FABRICATION. FA N S C H E D U L E DESIGNATION KEF - 1 KSF - 1 yf Vy MANUFACTURER LOREN COOK LOREN COOK Vy WEIGHT (LBS.) 684 646 4 MODEL NUMBER 365VX126 180ASP , B.H.S.F. CENTRIFUGAL ROOF SUPPLY FAN V Vy JJV TYPE y:)U V V N V w M UP -BLAST SIDE DISCHARGE 4 V V U AREA SERVED KITCHEN KITCHEN V C.F.M. 8000 6400 4 UJ E.S.P. (INCHES OF WATER) 3 1.5 V V V V V SONES 28 26 V V R.P.M. 1053 819 H. P. 7.5 5 vV� VOLT - PH - HZ 480 -3 -60 480 -3 -60 Id EE_ E 644759 DRIVE BELT BELT DETAILS AND BACKDRAFT DAMPER NO YES V REMARKS 1, 2, 3, 4 1, 2, 5, 6, 7 ') IN HOOD SWITCH KITCHEN HOOD /KEF - 1 REMARKS: 1. PROVIDE WITH BIRDSCREEN. 2. PROVIDE WITH INSULATED FACTORY CURB (1 1/2 ", 3LBS DENSITY), 13.5" HIGH, CONTINUOUSLY WELDED CORNERS, VENTED EXTENSION, HINGED SUB BASE, KEYWAY GREASE THROUGH STAINLESS HARDWARE TIE -DOWN EYELETS (4) .I,,jTy U 3. SHALL BE ALUMINUM CONSTRUCTION. - •_ ONNECTION '" ''{ 4. UPBLAST UL 762 LISTED, VENTED AND HINGED ROOF CURB, GREASE TRAP WITH DRAIN CONNECTION." SHALL CONTINUE RUNNING WHEN GREASE HOOD'S FIRE EXTINGUISHING SYSTEM ACTIVATES. 5. SHALL STOP RUNNING UPON ACTIVATION OF GREASE HOOD'S FIRE EXTINGUISHING SYSTEM. "I'R 'ULU 6. PROVIDE WITH WASHABLE ALUMINUM FILTERS. 7. FAN INTAKE SHALL BE AT 36" ABOVE FINISHED ROOF. KITCHEN HOOD AND DUCT SYSTEM NOTES 1. SUPPLY AND EXHAUST FANS ARE INTERLOCKED WITH A PILOT LIGHT IN KITCHEN AREA. 2. FIRE MODE REQUIRES THE EXHAUST FAN TO CONTINUE TO OPERATE, SUPPLY FAN STOPS AND ACTIVATES BUILDING ALARM SYSTEM. 3. HOOD EXHAUST FAN SHALL OPERATE WHENEVER THE EXTINGUISHING SYSTEM IS ACTIVATED. 4. FIXED PIPE EXTINGUISHING SYSTEM IN A SINGLE HAZARD AREA SHALL BE ARRANGED FOR SIMULTANEOUS AUTOMATIC OPERATION UPON ACTIVATION OF ANY OF THE SYSTEMS. 5. KITCHEN GREASE DUCTS AND EXHAUST EQUIPMENT SHALL CONFORM TO FBCM -2007, CHAPTER 5, SECTION 506 AND NFPA 96. 6. A SIGN SHALL BE PLACED ON ALL ACCESS PANELS STATING, "ACCESS PANEL - DO NOT OBSTRUCT ", IN A LETTER SIZE AT LEAST 1" INCH HIGH. 7. EXHAUST GREASE DUCT SHALL BE CONSTRUCTED OF BLACK STEEL 16 GA., (OR 18 GA. STAINLESS STEEL), CONTINUOUS LIQUID -TIGHT WELD MADE ON THE EXTERNAL SURFACE OF THE DUCT SYSTEM. 8. NEGATIVE PRESSURE IN COOKING AREA SHALL NOT EXCEED 0.02" W.G. 9. FIRE SUPPRESSION SYSTEM SEQUENCE OF OPERATION: UPON ACTIVATION OF THE KITCHEN HOOD FIRE SUPPRESSION SYSTEM (FIRE ALARM OR PULL STATION) THE FOLLOWING IS TO OCCUR. SOLENOID GAS MAIN SHUT -OFF VALVE CLOSES TO TURN OFF ALL GAS APPLIANCES. - ELECTRICAL APPLIANCES TURN OFF. - SEND SIGNAL TO BUILDING FIRE ALARM SYSTEM. -OUTSIDE AIR SUPPLY FAN SKF -1 TURNS OFF, THE HOOD EXHAUST FAN KEF -1 SHALL OPERATE WHENEVER THE EXTINGUISHING SYSTEM IS ACTIVATED. ?JVVV V VVU'JV UVV yf Vy V UV UV U V 4� Vy a u v U W 4 u V U U Vti V V`hv , B.H.S.F. 6200 S.W. 73 RD. street Miami, FL. 33143 V Vy JJV V V V y:)U V V N V w M . X y 4 V V U J V V U U k V J V •J 4 UJ u V V U U U V V V V V V V KEY PLAN V V V V r , U uuu LOCATION OF WORK UUV4` uUUVU vV� t 1sMEGNANIGAL. Q UA EZ, RE, Id EE_ E 644759 Sheet Title: DETAILS AND VV JF�V V HVAC J V Scale: AS NOTED VVVV V UyUVV ') U VVVM (: s SOUTH MIAN U51I N G�t� it PT. 'TUR //i.1. ;Fc-rloN s'r: LOUIS J. AGUIRRE & ASSOCIATES, P.A. Consulting Engineers 9150 South Dodeland Blvd. Suite 900 Miami @ Florida 33156 m CA 924 Telephone 305.670.0141 Facsimile 305.670.0144 www.ljoapa.com Project No.: 20046 Revised: ------ -- - a Client South Miami Hospital B.H.S.F. 6200 S.W. 73 RD. street Miami, FL. 33143 0 z H LU w M . X Cn M M LU LL_ F_ - N ■ 0 a�j Q z _0 ° M o cv 4 UJ c� Q) KEY PLAN ?rte! S.M.H. r r , LOCATION OF WORK Seal •per t 1sMEGNANIGAL. Q UA EZ, RE, Id EE_ E 644759 Sheet Title: DETAILS AND SCHEDULES HVAC Project No.. 20046 Date: 02.18.2011 Scale: AS NOTED Drawn by: J. H., F.P.,J.B. Checked by: V.A.,E.Z. Sheet Number: �ii17.00