11-122-006P -STAIR 1
— T.
RM. 412 11 RM. 411
RM. 413
RM. 414
V
T.
T.
`,11 T.
RM. 41011 RM. 409
DUCT
CONF. ROOM MED.
PREP.
❑ 0
CORRIDOR
aD
T. F\T.
NU. OFFICE
& CONF.
PATIENT WING
CORRIDOR
T. /-I I \ T.
NURSES
RM. 40611 RM. 405
CL. CLEAN
—J� UTIL.
SOIL
UTIL.
RM. 404 II RM. 403
T- \T.
STRETCHER
ALCOVE
SITZ
TREATMENT
CART
ALCOVE
��.. .. .�!. _ - rte•— — � �_
T. / I \ T.
T.
T.
J.C.
CLO. NURSES
STATION a
RM. 402 II RM. 401
ISOL. ROOM
0
T.
ELEC. CLQ�
[77:71 7-7
NU. LOUNGE
DATA
ROOM
DATA
ROOM
E L E V
ELEV.
LOBBY
EXISTING DATA
ROOM
ELEC. CLO.
N. T� j
�IJ SUPPORT
0
SERVICES
STORAGE
NEW WORK ON TES:
1). SEE VISICU EQUIPMENT ELEVATION DETAIL FOR EXACT MOUNTING HEIGHTS OF POWER
AND DATA OUTLET. COORDINATE WIRH PROJECT MANAGER FOR EXACT LOCATION. TYPICAL.
2.) COORDINATE EXACT LOCATION OF EACH DEVICE WITH VISICU REPRESENTATIVE AND
OWNER.
3.) ALL WORK INSIDE THE PATIENT ROOM AND IN CORRIDOR SHALL BE DONE USING AIRE
GUARDIAN MOBILE CONTAINMENT CUBE CONSTRUCTION ISOLATION BY ABATEMENT
TECHNOLOGIES (CALL SUE HOFFMANN AT 1- 800 - 634 - 9091).
4.) ALL EQUIPMENT SHALL BE MOUNTED FOLLOWING MANUFACTURER RECOMMENDATIONS.
T. T.\,, T. T. T. T VRM. T. T T T NEW WALL MOUNTED " ELERT" CALL BUTTON FOR VISICU SYSTEM. ELERT
BUTTON SHALL BE MOUNTED NO HIGHER THAN 4' A.F.F. (TOP OF DEVICE).
CONTRACTOR SHALL PROVIDE /INSTALL A DEEP GANG OR OPEN ENDED
RM. 415 RM. 416 D RM. 417 RM. 418 RM. 419 RM. 420 421 RM. 422 42 RM. 424 RM. 425 RM. 426 ELECTRICAL BOX WITH A J" EMPTY CONDUIT TO CEILING SPACE FOR LOW
CJ p VOLT AGE WIRES. PATCH CABLE COMING FROM WALL NEEDS TO BE
D _ TERMINATED WITH A MALE RJ45 CONNECTOR. TYPICAL FOR ROOMS 408,
I SP S SP S Sp I 420, 423, 424 & 425.
I I NEW CEILING MOUNTED SPEAKER FOR VISICU SYSTEM.
19 19 TYPICAL FOR ROOMS 408, 420, 423, 424 & 425.
I
I NEW WALL MOUNTED MONITOR FOR VISICU SYSTEM. CONTRACTOR SHALL
V V I PROVIDE /INSTALL NEW GCX POLYMOUNT WALL CHANNEL AS HIGH AS
ryl F'yl F-",Yl 1L I V V V HEIGHT ILSHALL ARTICULATING
BE FIELD N COO DINATE )E SEE OSUPPORTXBACKG MOUNTING DETAIL IN
SHEET E -8. TYPICAL FOR ROOMS 408, 420, 423, 424 & 425.
NEW WALL MOUNTED CAMERA WITH MICROPHONE FOR VISICU SYSTEM.
NEW WALL MOUNTED AV SERVER FOR VISICU SYSTEM. CONTRACTOR SHALL PROVIDE /INSTALL PELCO WALL CAMERA MOUNT MODEL
CONTRACTOR SHALL INSTALL 1 EMPTY CONDUIT FROM #EM4400 AT A MINIMUM OF 10" FROM THE WALL MOUNTED DATA OUTLET.
AV SERVER ENCLOSURE TO CEILING SPACE FOR LOW CAMERA MOUNT MUST BE ATTACHED TO AN EXISTING WALL STUD USING
VOLTAGE WIRES. TYPICAL FOR ROOMS 408, 420, 423,
424 & 425. (2)0.281"0 SCREWS. TYPICAL FOR ROOMS 408, 420, 423, 424 & 425.
PARTIAL 4TH FLOOR PAVILION BUILDING
SYSTEMS PLAN NEW WORK
a.v. -ra
A%EAQc WOW
4TH FLOOR KEY PLAN
T.
OFFI
FA
l
0�
i U � q y ape
moa.
o0
w
0
a Q
N
z
0
0
U
0
f °
U
w
2j, o
-�
W
O
CD
Z
0
Q
Q
W
�
at
_mZ
M
W
Z
O
QZ
Q
Q
=
�
-OU
cry
m
Q
M
a-
cry
cn
0
FlLE:
Q
JOB NO.:
210
-840
DATE :
12 -01
-10
PLOT SIZE:
O
CD
Z
Q
LJi
--I
W
�
Z
_mZ
Z
O
�.
Q
�
�Q
cry
m
Q
cl -
a-
cry
cn
0
FlLE:
JOB NO.:
210
-840
DATE :
12 -01
-10
PLOT SIZE:
AS
NOTED
DESIGNED /DRAWN BY:A•V,
CHECKED BY:
F.A.
SHEET No.:
E -5
SHEET 5 OF 8