Loading...
11-1216-009I Ln 00 r� d N N cD 0 z CL CK CD 0 w 0 z N 0 N W V) w w w 00 0 0 0 r-D CD i m a i Npw i ° milm Irr CTI IR rj---� PARTIAL SECOND FLOOR PLAN �,EWV 5cAL1<: I/8" = I'-O' PARTIAL SECOND FLOOR PLAN !.01 5GALE. 118" = P -0' I V OEXISTING SURFACE MOUNTED VISICUE SERVER TO BE WALL RECESSED IN PLACE. CONTRACTOR SHALL: 1- PROVIDE NEW RECESSED 14W"X28'H LEVITON STRUCTURED MEDIA ENCLOSURE (280 SERIES) WITH PREMIUM HINGED DOOR. 2- COORDINATE FOR POSSIBLE RELOCATION OF ANY EXISTING CONDUITS INSIDE PARTITION IN CONFLICT WITH THE NEW RECESSED BOX. 3- RELOCATE EXISTING DATA AND POWER RECEPTACLE OUTLETS INSIDE OF THE NEW RECESSED BOX. 4- RECONNECT ALL SYSTEMS IN NEW LOCATION AND TEST THE ENTIRE SYSTEM FOR PROPER FUNCTIONING. (D PROPOSED NEW SINGLE RECEPTACLE FOR NEW ICU MONITOR FLAT PANEL RECEPTACLE SHALL BE CONNECTED TO EXISTING CRITICAL CIRCUIT DEDICATED Fl EXISTING VISICUE SYSTEM SERVERS. NEW MONITOR SHOULD BE HORIZONTALLY ALIGNED WITH EXISTING TV IN THE ROOM. COORDINATE EXACT LOCATION WITH THE OWNER (TYPICAL. (3) PROVIDE ALLOWANCE TO RELOCATE EXISTING WIRED DIGITAL CLOCK,TV AND TV N POWER /CATV OUTLETS UP TO 5 FT TO ACCOMMODATE THE NEW MONITOR AS CLOSE AS POSSIBLE TO THE EXISTING ASICUE SYSTEM CAMERA. FLOOR PLANS SHOW PROPOSED LOCATIONS ONLY, EXACT LOCATION SHALL BE DETERMINED IN COORDINATION WITH THE OWNER AND HOSPITAL IT DEPARTMENT ONEW LCD MONITOR LOCATED ADJACENT TO EXISTING CAMERA ELECTRICAL KEY NOTES - ALTERNATE BID: 0 ( 1 1 RELOCATE EXISTING SURFACE MOUNTED VISICUE SYSTEM SERVER TO A NEW �`.. // WALL RECESSED LOCATION INSIDE THE ICU ROOM WITHIN 10' AWAY (IN ANY DIRECTION) OF THE EXISTING LOCATION SHOWN IN THE BASE BID PLANS. CONTRACTOR SHALL 1— PROVIDE NEW RECESSED 14W'X28"H LEVITON STRUCTURED MEDIA ENCLOSURE (280 SERIES) WITH PREMIUM HINGED DOOR. 2— PROVIDE NEW CAT 5e CABLE HOMERUN TO EXISTING IT CLOSET ALONG WITH NEW SYSTEM CABLING BETWEEN VISICUE SERVER AND EXISTING CAMERA, SPEAKER, MICROPHONE AND EALERT BUTTON. DATA CABLE SHALL NOT BE SPLICED. 3— RELOCATE EXISTING RECEPTACLE AND CIRCUIT FEEDING THE EXISTING EQUIPMENT. 4— RECONNECT ALL SYSTEMS IN NEW LOCATION AND TEST THE ENTIRE SYSTEM FOR PROPER FUNCTIONING. COORDINATE EXACT LOCATION IN EACH ROOM WITH OWNER REPRESENTATIVE AND VISICUE SYSTEM MANUFACTURER. (NOT SHOWN ON PLANS) OPROPOSED NEW SINGLE RECEPTACLE FOR NEW ICU MONITOR FLAT PANEL RECEPTACLE SHALL BE CONNECTED TO EXISTING CIRCUIT DEDICATED FOR �NED WITH EXISMA SYSTEM IS ROOM. COORDINATE SHOULD BE LOC�,ATION WITH THE OWNER (TYPICAL. 3 PROVIDE ALLOWANCE TO RELOCATE EXISTING TV AND TV POWER /CATV OUTLETS UP TO 5 FT TO ACCOMMODATE THE NEW MONITOR AS CLOSE AS POSSIBLE TO THE EXISTING VISICUE SYSTEM CAMERA. FLOOR PLANS SHOW PROPOSED LOCATIONS ONLY, EXACT LOCATION SHALL BE DETERMINED 6 PROVIDE ALTERNATE DEDUCT PRICE FOR THE WORK ASSOCIATED WITH THE INSTALLATION OF THE DATA CABLE AND DATA OUTLET. INSTEAD THE THE CONTRACTOR WILL RE —USE EXISTING INACTIVE DATA PORT CURRENTLY INTERCONNECTING CAMERA AND VISICUE SERVER TO INTERCONNECT NEW MONITOR AND VISICUE SERVER. R211-6 (2) 0 c DUPLEX RECEPTACLE NAMEPLATE WITH PANEL AND CIRCUIT DESIGNATION TOGGLE SWITCH NAMEPLATE WITH PANEL AND CIRCI DESIGNATION PROPOSED NEW SINGLE RECEPTACLE FOR NEW ICU MONITOR FLAT PANEL (NEW MONITOR SHOULD BE HORIZONTALLY ALIGNED WITH EXISTING TV IN THE ROOM (COORDINATE EXACT THE OWNER) (TYPICAL) CTION WITH 12B -37 STING CRITICAL POWER MERLIN TO CRITICAL PANEL 'PICAL) * APPLIES TO ALL DEVICES, ALL AREAS ** RECEPTACLES CONNECTED TO THE CRITICAL BRANCH OF THE EMERGENCY SYSTEM SHALL BE PROVIDED WITH A RED FACEPLATE. 1 ) TYPICAL ELECTRICAL DEVICE ENGRAVING DETAIL- N.T.S. DOUBLE STUD ® SIDES )F OPENINGS 40TCH AT VERTICAL' STUDS, TYP. i" X 18 GA BACKING )TUD ATTACHED TO STUDS W/ (3) #12 -14 -.H.S.D.S. ?0 GA MTL STUDS TYP., U.O.N. 2) HEAVY DUTY BACKING DETAIL ►-' 1. USE #12 SELF TAPPING SHEET METAL SCREWS WHEN ATTACHING ITEMS TO BLOCKING PLATE. 2. WALL STUD FLANGES ARE CONTINUOUS AT BACKING STUD OR PLATE. \. 3ard, Rao + Athanas Consulting Engineers, LLC 2600 Douglas Road :3uite 301 Coral Gables, FL 33134 tel 205.529.1515 fax 305.529.1112 www.brplusa.corn r SALTS MICHELSON A R C H I T E C T S 3501 Griffin Road Ft. Lauderdale, FL 33312 (954) 266 -2700 Fx: (954) 266 -2701 stztaC saltztzticlzelson.eotn NN OF Nguyen Perez PE72149