Loading...
11-1216-006OVER -SIZED HOLE IN BASIC, PARTITION TYPE '5 5GREW5 MIN. TWO PER 5EGT. CUT OP6. TO WITHIN 1/4' OF PENETRATION AND SEAL WITH FIRE CAULK OVER -51ZED HOLE I BASIC PARTITION TYPE '5 5GREW5 M TWO PER SECT. r� j CENTERLINE OF 5105 5 OPENIN65 QVE 3" QIA. FOR ALL PENETRATIONS WITH 6AP5 GREATER THAN I 12 ", APPLY GYP. BD. 3" 3' PATCH (SEE PATCHING DETAIL TH15 SHEET.) 1N IN, IF MAX. GAP AROUND PENETRATION 15 I /5" OR LE55, O � APPLY 5URFAGE BEAD OF USG ACOUSTICAL SEALANT. IF 6AP AROUND PENETRATION 15 GREATER THAN I 15' BUT O_ LESS THAN 114 ", FILL GAP WITH GUT OP6, TO WITHIN I /4' FIRE CAULK. OF PENETRATION AND SEAL WITH FIRE CAULK IF GAP AROUND PENETRATION OPENING UP TQ' DIA. 15 GREATER THAN 1/4' BUT LESS THAN 112 ", FILL GAP WITH FIRE CAULK (REF: GE6 I - 25 -55) NOTE: SKIM GOAT BACK SIDE OF ALL PAT6HE5 WITH DRYWALL COMPOUND. ATTACH WITH 56REW5 AS NOTED. LEAVE ALL 5CREW5 EXPOSED. PAT6HE5 SHALL BE TYPE 'X" GYP, IN THE SAME THIGKNE55 USED FOR WALL CON5TR. DO NOT TAPE d MUD EDGES. NOTE: IF PIPE 15 TO BE INSULATED DO NOT RUN IN50LATION THROUGH THE WALL. AFTER PAGKIN6 GAP THROUGH NALL WITH EITHER DRYWALL COMPOUND OR SARNO INSULATION AS INDICATED BELOW, FLARE INSULATION ONTO FACE OF WALL AROUND PIPE ON BOTH 5IDE5 OF WALL, AND 5EAL TO FACE OF WALL WITH INSULATION MASTIC. NOTE: TH15 15 A TYPICAL ARRANGEMENT REPEAT TH15 PROCEDURE A5 NEEDED TO AC 0MOPATE ALL CONDUIT AND PIPE PENETRATIONS THROUGH THE WALLS. METAL RUNNERS ONE OR TWO LAYER DRYWALL -A5 PER FIRE FILL VOID MIN. 112" THICK OF RATING ON PARTITION FIRE CAULK. FLUSH WITH BOTH SURFACES OF WALL. AL50 PROVIDE MIN. 1/4" DIA. BEAD OF CAULK APPLIED TO GYP. BOARD/ PIPE INTERFACE AT PACK WITH 4 PGF MINERAL WOOL POINT OF CONTACT BOTH ON BATT IN50LATION WITH NO VOIDS 5IDE5 — OR 6AP5 CAULK:- 3M COMPANY "IG 15WB' OR "GP25WB +" SUPPORT PIPES AND GONDUIT5 ON EACH 51DE OF WALL IF ANY PIPES ARE TO BE INSULATED, DO NOT RUN INSULATION THROUGH A WALL. AFTER PACKING GAP AROUND PIPE THROUGH THE WALL WITH 5AFING INSULATION AND DRYWALL MUD, FLARE INSULATION ONTO FACE OF WALL AROUND PIPE ON BOTH 5IDE5 OF WALL, AND SEAL TO FACE OF WALL WITH INSULATION MASTIC, METAL 5TUD5 O O IECTION Of NZ -._....__ ............. ..._...... _ ... .__....__......_. m�u - - - - - O z m QZ tD OPENIN65 QVE 3" QIA. FOR ALL PENETRATIONS WITH 6AP5 GREATER THAN I 12 ", APPLY GYP. BD. 3" 3' PATCH (SEE PATCHING DETAIL TH15 SHEET.) 1N IN, IF MAX. GAP AROUND PENETRATION 15 I /5" OR LE55, O � APPLY 5URFAGE BEAD OF USG ACOUSTICAL SEALANT. IF 6AP AROUND PENETRATION 15 GREATER THAN I 15' BUT O_ LESS THAN 114 ", FILL GAP WITH GUT OP6, TO WITHIN I /4' FIRE CAULK. OF PENETRATION AND SEAL WITH FIRE CAULK IF GAP AROUND PENETRATION OPENING UP TQ' DIA. 15 GREATER THAN 1/4' BUT LESS THAN 112 ", FILL GAP WITH FIRE CAULK (REF: GE6 I - 25 -55) NOTE: SKIM GOAT BACK SIDE OF ALL PAT6HE5 WITH DRYWALL COMPOUND. ATTACH WITH 56REW5 AS NOTED. LEAVE ALL 5CREW5 EXPOSED. PAT6HE5 SHALL BE TYPE 'X" GYP, IN THE SAME THIGKNE55 USED FOR WALL CON5TR. DO NOT TAPE d MUD EDGES. NOTE: IF PIPE 15 TO BE INSULATED DO NOT RUN IN50LATION THROUGH THE WALL. AFTER PAGKIN6 GAP THROUGH NALL WITH EITHER DRYWALL COMPOUND OR SARNO INSULATION AS INDICATED BELOW, FLARE INSULATION ONTO FACE OF WALL AROUND PIPE ON BOTH 5IDE5 OF WALL, AND 5EAL TO FACE OF WALL WITH INSULATION MASTIC. NOTE: TH15 15 A TYPICAL ARRANGEMENT REPEAT TH15 PROCEDURE A5 NEEDED TO AC 0MOPATE ALL CONDUIT AND PIPE PENETRATIONS THROUGH THE WALLS. METAL RUNNERS ONE OR TWO LAYER DRYWALL -A5 PER FIRE FILL VOID MIN. 112" THICK OF RATING ON PARTITION FIRE CAULK. FLUSH WITH BOTH SURFACES OF WALL. AL50 PROVIDE MIN. 1/4" DIA. BEAD OF CAULK APPLIED TO GYP. BOARD/ PIPE INTERFACE AT PACK WITH 4 PGF MINERAL WOOL POINT OF CONTACT BOTH ON BATT IN50LATION WITH NO VOIDS 5IDE5 — OR 6AP5 CAULK:- 3M COMPANY "IG 15WB' OR "GP25WB +" SUPPORT PIPES AND GONDUIT5 ON EACH 51DE OF WALL IF ANY PIPES ARE TO BE INSULATED, DO NOT RUN INSULATION THROUGH A WALL. AFTER PACKING GAP AROUND PIPE THROUGH THE WALL WITH 5AFING INSULATION AND DRYWALL MUD, FLARE INSULATION ONTO FACE OF WALL AROUND PIPE ON BOTH 5IDE5 OF WALL, AND SEAL TO FACE OF WALL WITH INSULATION MASTIC, METAL 5TUD5 VERTIGAL METAL 5TUD5 ® 16" O,G. MAX. BEHIND GYP. BD. IECTION I14" MIN. GUT GYP, BD. TIGHT TO CONDUIT FIRMLY PACK WITH 2" OR PIPING (I/4" MAX. CAP) AND 4PGF MINERAL WOOL SEAL A5 REQ'D. BATT INSULATION -_ --- REGE55 PAGKIN6 MATERIAL FROM BOTH ~- --' ' 5IDE5 OF WALL Ii CONDUIT OR PIPI NG A55EMBLY 45 -I/2" MAX. EQUIVALENT TO UL 5Y5TEM TYPIGAL MULTIPLE CONDUIT OR PIPE PENETRATION THROUGH ALL WALL5 PIPE PENETRATION DETAILS SCALE: N.T.5. UL SYSTEM #CAJ2165 3 HOUR RATING PVC PIPE OR CONDUIT 5/5" DIAM, MIN. FIRE -RATED GONCRETE NUCO ING 5ELF SEAL 66 -266 FLOOR SLAB 4" MIN. THICK �. PENETRATION FIRESTOP FOR MAX. 2" DIA. PRIG PIPE /GONDUIT THROUGH A GONGRETE FLOOR UL 5Y5TEM #WL203q I HOUR RATING SHOWN -- GYP, WALL BRD. STEEL STUD 5/5" MIN. DIAMETER WR 6RAGE b GO - GONN F5P 1100 PUTTY OR F5 Ig00 SEALANT PVC PIPE OR CONDUIT 5/5" MIN. DIAMETER HR 6RAGE d GO - CONN F5P 1100 PUTTY OR F5 16100 SEALANT PENETRATION F 1 RE5TOP FOR PGV PIPE /GONDU I T THROUGH GYPSUM WALL BOARD UL SYSTEM #WL 1001 I HOUR RATING SHOWN GYP. WALL BRD. STEEL STUD 1/4" MIN. DIAMETER 3M FIRE BARRIER GP25 N/5 CAULK METALLIC PIPE OR CONDUIT 6P25 N/5 CAULK PENETRATION FIRE5TOP FOR METAL PIPE/CONDUIT THROUGH GYP5UM WALL BOARD UL SYSTEM #GAJI003 3 HOUR RATING METAL PIPE OR CONDUIT PAGKIN6 MATERIAL FIRE -RATED CONCRETE FLOOR SLAB PENETRATION DETAILS SCALE: N,T5 FILL VOID OR CAVITY SEALANT PENETRATION F I RE5TOP FOR MAX. h" DIA. METAL PIPE /GONDUIT THROUGH A GONGRETE FLOOR EQUIVALENT TO UL 5Y5TEM #(_AJ1003 3 HOUR RATING NOTE: A)FOR GONG. BLOCK WALL FILL IMMEDIATELY ADJ, AREAS WITH CONCRETE THEN APPLY THIS DETAIL B)ALL PIPES, CONDUITS, DUCTS, AT ALL FIRE WALL PENETRATION SHALL BE DONE AT qO DEGREE5 ANGLE ON BOTH 5IDE5 BOTTOM OF STRUCTURE p SEAL (TYP) v v z' FIRE BARRIER PUTTY PIPE TYP, RS TYP. BOTH SID METAL PIP VSEAL (TYP.) a DRY WALL OVER METAL ° PACK IN FILL WITH FURRING STRIPS ° FIRE 5AFIN65 a INSULATION v PIPE PENETRATION THRU GONGRETE WALL FORMING MATERIAL 2ND FLOOR SLAB OR ROOF — WHERE TH15 CONDITION OCCURS 1/4" FILL MATERIAL FLUSH W/ EACH SURFACE 3M- FB - 20W ?'a`PPf)VIED TAY: GONGRETE WALL TO SLAB 3M 6P -25WB OR GP -25 N/5 I' MIN, FILL MATERIAL FLUSH vv SURFACE 2ND FLOOR SLAB OR ROC WHERE TH15 CONDITION OC 4.0 PGF MINERAL WOOL B INSULATION FIRMLY PAGKL FIRE 5TOP DETAIL UL# HW -D -1003 PRE( A5T GONG, PANEL HORIZONTAL JOINT FIRE 5TOP DETAIL UL# FW -5 -0001 SALTS MICHELSON A R C H I T E C T S 3501 Griffin Road Ft. Lauderdale, FL 33312 (954) 266 -2700 Fx: (954) 266-2701 sma@saltzmichelson.com Charles Michelson AR0009976 ;5 U Project No.: 2011 -166 Drawn By: NH Checked By: LS Date: 09 -12 -11 Am. STRIJUC URA' IECTION ?'a`PPf)VIED TAY: GONGRETE WALL TO SLAB 3M 6P -25WB OR GP -25 N/5 I' MIN, FILL MATERIAL FLUSH vv SURFACE 2ND FLOOR SLAB OR ROC WHERE TH15 CONDITION OC 4.0 PGF MINERAL WOOL B INSULATION FIRMLY PAGKL FIRE 5TOP DETAIL UL# HW -D -1003 PRE( A5T GONG, PANEL HORIZONTAL JOINT FIRE 5TOP DETAIL UL# FW -5 -0001 SALTS MICHELSON A R C H I T E C T S 3501 Griffin Road Ft. Lauderdale, FL 33312 (954) 266 -2700 Fx: (954) 266-2701 sma@saltzmichelson.com Charles Michelson AR0009976 ;5 U Project No.: 2011 -166 Drawn By: NH Checked By: LS Date: 09 -12 -11 Am.